Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Angular oversampling with temporally offset layers on multilayer detectors in computed tomography

Purpose: Today’s computed tomography (CT) scanners operate at an increasingly high rotation speed in order to reduce motion artifacts and to fulfill the requirements of dynamic acquisition, e.g., perfusion and cardiac imaging, with lower angular sampling rate as a consequence. In this paper, a simple method for obtaining angular oversampling when using multilayer detectors in continuous rotation CT is presented. Methods: By introducing temporal offsets between the measurement periods of the different layers on a multilayer detector, the angular sampling rate can be increased by a factor equal to the number of layers on the detector. The increased angular sampling rate reduces the risk of producing aliasing artifacts in the image. A simulation of a detector with two layers is performed to prove the concept. Results: The simulation study shows that aliasing artifacts from insufficient angular sampling are reduced by the proposed method. Specifically, when imaging a single point blurred by a 2D Gaussian kernel, the method is shown to reduce the strength of the aliasing artifacts by approximately an order of magnitude. Conclusions: The presented oversampling method is easy to implement in today’s multilayer detectors and has the potential to reduce aliasing artifacts in the reconstructed images.

60 APPLIED LIFE SCIENCES↗

SU-F-T-410: Investigation of Treatment Planning Accuracy with the Presence of Magnetic Injection Port (breast Tissue Expander)

Purpose: Mastectomy patients with breast reconstruction usually have a magnetic injection port inside the breast during radiation treatments. The magnet has a very high CT number and produces severe streaking artifact across the entire breast in CT images. Our routine strategy is to replace the artifact volumes with uniform water, and it is necessary to validate that the planned dose, with such an artifact correction, is sufficiently accurate. Methods: A phantom was made with a gelatine-filled container sitting on a Matrixx detector, and the magnetic port was inserted into gelatine with specific depths and orientations. The phantom was scanned on a CT simulator and imported into Eclipse for treatment planning. The dose distribution at the Matrixx detector plane was calculated for raw CT images and artifact-corrected images. The treatment beams were then delivered to the phantom and the dose distributions were acquired by the Matrixx detector. Gamma index was calculated to compare the planned dose and the measurement. Results: Three field sizes (10×10, 15×15 and 20×20) and two depths (50mm and 20mm) were investigated. With the 2%/2mm or 3%/3mm criteria, several points (6–10) failed in the plan for raw CT images, and the number of failure was reduced close to zero for the corrected CT images. An assignment of 10,000 HU to the magnet further reduced the dose error directly under the magnet. Conclusion: It is validated that our routine strategy of artifact correction can effectively reduce the number of failures in the detector plane. It is also recommended to set the magnet with a CT number of 10,000HU, which could potentially improve the dose calculation at the points right behind the magnet.

60 APPLIED LIFE SCIENCES↗

SU-F-T-443: Quantification of Dosimetric Effects of Dental Metallic Implant On VMAT Plans

Purpose: To evaluate the dosimetric impact of metallic implant that correlates with the size of targets and metallic implants and distance in between on volumetric-modulated arc therapy (VMAT) plans for head and neck (H&N) cancer patients with dental metallic implant. Methods: CT images of H&N cancer patients with dental metallic implant were used. Target volumes with different sizes and locations were contoured. Metal artifact regions excluding surrounding critical organs were outlined and assigned with CT numbers close to water (0HU). VMAT plans with half-arc, one-full-arc and two-full-arcs were constructed and same plans were applied to structure sets with and without CT number assignment of metal artifact regions and compared. D95% was utilized to investigate PTV dose coverage and SNC Patient− Software was used for the analysis of dose distribution difference slice by slice. Results: For different targets sizes, variation of PTV dose coverage (Delta-D95%) with and without CT number replacement reduced with larger target volume for all half-arc, one-arc and two-arc VMAT plans even though there were no clinically significant differences. Additionally, there were no significant variations of the maximum percent difference (max.%diff) of dose distribution. With regard to the target location, Delta-D95% and max. %diff dropped with increasing distance between target and metallic implant. Furthermore, half-arc plans showed greater impact than one-arc plans, and two-arc plans had smallest influence for PTV dose coverage and dose distribution. Conclusion: The target size has less correlation of doseimetric impact than the target location relative to metallic implants. Plans with more arcs alleviate the dosimetric effect of metal artifact because of less contribution to the target dose from beams going through the regions with metallic artifacts. Incorrect CT number causes inaccurate dose distribution, therefore appropriately overwriting metallic artifact regions with reasonable CT numbers is recommended. More patient data are collected and under further analysis.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-09: MRI Evaluation of a Direction-Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer On 3T

Purpose: To assess image quality and artifact extent of a novel direction modulated brachytherapy (DMBT) tandem applicator on a 3T MRI using various clinical imaging sequences. Methods: The tandem applicator is composed of a tungsten alloy with 6 peripheral grooves covered with a PEEK tip. An MR-compatible phantom with similar dimensions to the female pelvis was manufactured. To visually assess the spatial shift of the applicator’s tip, a mountable radial-fiducial with 4 plastic rods, each of 3mm diameter, was designed to tightly fit on the applicator. The rods are separated by 16 mm and mounted at 90-degree relative to one another. The pelvis phantom was filled with a solution of MnCl2 to mimic T2 relaxation time of the cervix (60-80 ms at 3T).Imaging was performed on a 3T Philips Achieva using a 16-channel Torso coil array. Four MR sequences were tested: T2-weighted fast spin-echo (T2w-FSE), proton density weighted FSE (PDw-FSE), T1-weighted FSE (T1w-FSE) and T1 weighted spoiled gradient echo (T1w-GE). The spatial resolution was kept the same between all sequences: 0.6 × 0.6 × 3 mm{sup 3} with no slice gaps. Para-sagittal images were acquired with the applicator fixed at a 30-degree angle anterior to the B0- field to mimic clinical settings. Results: Minimal artifacts were observed on T2w-FSE, PDw-FSE and T1-FSE, while significant artifacts were seen on T1w-GE images. Artifacts induced in all 3 FSE sequences did not hinder accurate localisation of the tip and the applicator boundaries. The drift of the applicator’s centreline from the radial fiducials was measured and found to be < 1 mm for the 3 FSE sequences. Conclusion: The tungsten–based DMBT applicator can be potentially used on 3T with various clinical sequences without inducing significant artifacts. Further validation on patients as well as the evaluation of relative SNR among the different sequences is required.

60 APPLIED LIFE SCIENCES↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Primer on Use of Multi-Spectral and Infra Red Imaging for On-Site Inspections

The purpose of an On-Site Inspection (OSI) is to determine whether a nuclear explosion has occurred in violation of the Comprehensive Nuclear Test Ban Treaty (CTBT), and to gather information which might assist in identifying the violator (CTBT, Article IV, Paragraph 35) Multi-Spectral and Infra Red Imaging (MSIR) is allowed by the treaty to detect observables which might help reduce the search area and thus expedite an OSI and make it more effective. MSIR is permitted from airborne measurements, and at and below the surface to search for anomalies and artifacts (CTBT, Protocol, Part II, Paragraph 69b). The three broad types of anomalies and artifacts MSIR is expected to be capable of observing are surface disturbances (disturbed earth, plant stress or anomalous surface materials), human artifacts (man-made roads, buildings and features), and thermal anomalies. The purpose of this Primer is to provide technical information on MSIR relevant to its use for OSI. It is expected that this information may be used for general background information, to inform decisions about the selection and testing of MSIR equipment, to develop operational guidance for MSIR use during an OSI, and to support the development of a training program for OSI Inspectors. References are provided so readers can pursue a topic in more detail than the summary information provided here. The following chapters will provide more information on how MSIR can support an OSI (Section 2), a short summary what Multi-Spectral Imaging and Infra Red Imaging is (Section 3), guidance from the CTBT regarding the use of MSIR (Section 4), and a description of several nuclear explosion scenarios (Section 5) and consequent observables (Section 6). The remaining sections focus on practical aspects of using MSIR for an OSI, such as specification and selection of MSIR equipment, operational considerations for deployment of MISR equipment from an aircraft, and the conduct of field exercises to mature MSIR for an OSI. Finally, an appendix provides detail describing the magnitude and spatial extent of the surface shock expected from an underground nuclear explosion. If there is a seismic event or other data to suggest there has been a nuclear explosion in violation of the CTBT, an OSI may be conducted to determine whether a nuclear explosion has occurred and to gather information which may be useful in identifying the party responsible for conducting the explosion. The OSI must be conducted in the area where the event that triggered the inspection request occurred, and the inspected area must not exceed 1,000 square kilometers, or be more than 50 km on aside (CTBT Protocol, Part II, Paragraphs 2 and 3). One of the guiding principles for an inspection is that it be effective, minimally intrusive, timely, and cost-effective [Hawkins, Feb 1998]. In that context, MSIR is one of several technologies that can be used during an aircraft overflight to identify ground regions of high interest in a timely and cost-effective manner. This allows for an optimized inspection on the ground. The primary purpose for MSIR is to identify artifacts and anomalies that might be associated with a nuclear explosion, and to use the location of those artifacts and anomalies to reduce the search area that must be inspected from the ground. The MSIR measurements can have additional utility. The multi-spectral measurements of the ground can be used for terrain classification, which can aid in geological characterization of the Inspected Area. In conditions of where light smoke or haze is present, long-wave infrared imaging can provide better imaging of the ground than is possible with standard visible imagery.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Testing the LSST Difference Image Analysis Pipeline Using Synthetic Source Injection Analysis

Abstract We evaluate the performance of the Legacy Survey of Space and Time Science Pipelines Difference Image Analysis (DIA) on simulated images. By adding synthetic sources to galaxies on images, we trace the recovery of injected synthetic sources to evaluate the pipeline on images from the Dark Energy Science Collaboration Data Challenge 2. The pipeline performs well, with efficiency and flux accuracy consistent with the signal-to-noise ratio of the input images. We explore different spatial degrees of freedom for the Alard–Lupton polynomial-Gaussian image subtraction kernel and analyze for trade-offs in efficiency versus artifact rate. Increasing the kernel spatial degrees of freedom reduces the artifact rate without loss of efficiency. The flux measurements with different kernel spatial degrees of freedom are consistent. We also here provide a set of DIA flags that substantially filter out artifacts from the DIA source table. We explore the morphology and possible origins of the observed remaining subtraction artifacts and suggest that given the complexity of these artifact origins, a convolution kernel with a set of flexible bases with spatial variation may be needed to yield further improvements.

Liu, S. (ORCID:0000000244612143)↗

Fourier method for 3-dimensional data fusion of X-ray Computed Tomography and ultrasound

X-ray Computed Tomography (CT) is essential for nondestructive inspection of many manufactured components but is susceptible to various forms of artifacts and noise. In particular, multi-detector row cone-beam CT systems can suffer from so called “cone-beam” artifacts and partial volume effects, particularly on planar edges at the periphery of the field of view in the cone angle dimension. Uni-directional ultrasonic testing methods generally have extremely accurate in-plane depth resolution but poorer lateral resolution due to physical and geometric constraints. This paper presents a novel technique called Computed Tomographic Fusion (CT-F) which uses three-dimensional Fourier filtering to combine x-ray cone-beam CT reconstructions and ultrasound data in the frequency space. The result is a single image with improved accuracy and quality. CT-F mitigates artifacts while allowing for rapid, accurate characterization of large three-dimensional CT volumes. Finally, using simulations and experiments, we demonstrate artifact reduction and edge contrast improvement in volumetric reconstructions.

42 ENGINEERING↗

Orthopedic metallic hardware in routine abdomino-pelvic CT scans: occurrence and clinical significance

Purpose: To study the occurrence of orthopedic metallic hardware in routine abdomen/pelvic computed tomography (CT) scans and their impact on image quality (IQ) and diagnostic evaluation. Material and methods: In this retrospective single institution study, we analyzed 3500 consecutive abdomen/pelvis CT scans for occurrence of orthopedic metallic hardware. In the cohort of patients with metallic hardware detected on CT scans, subjective and objective IQ analysis was performed to estimate diagnostic acceptability (DA, 4-point scale), subjective noise (SN, 3-point scale), presence of artifacts (PA, 4-point scale) and objective noise. The clinical significance of metallic hardware was determined by evaluating the impact of artifacts on radiological diagnosis according to the clinical indication and disease type. Results: Orthopedic metallic hardware was encountered in 4.97% of abdomino-pelvic CT scans (n = 174/3500), and artifacts related to the hardware in the region of clinical interest were identified in 82% (n = 144/174) of scans. The overall mean DA was 2.66 (n = 174), and it was severely limited (score < 2) in 32% of cases particularly affecting patients with bilateral hip implants (92.6%, n = 25/27). The artifacts due to hardware significantly limited diagnostic evaluation in 58.6% of cases (PA score ≥ 3), and the image noise was unacceptable in 71% of cases (SN score > 2) in the region of clinical interest. Conclusion: Orthopedic metallic hardware is encountered in nearly 5% of abdomino-pelvic CT scans and causes significant image degradation limiting diagnostic evaluation in the region of clinical interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Novel Amplitude/Phase Binning Algorithm on Commercial Four-Dimensional Computed Tomography Quality

Purpose: Respiratory motion is a significant source of anatomic uncertainty in radiotherapy planning and can result in errors of portal size and the subsequent radiation dose. Although four-dimensional computed tomography allows for more accurate analysis of the respiratory cycle, breathing irregularities during data acquisition can cause considerable image distortions. The aim of this study was to examine the effect of respiratory irregularities on four-dimensional computed tomography, and to evaluate a novel image reconstruction algorithm using percentile-based tagging of the respiratory cycle. Methods and Materials: Respiratory-correlated helical computed tomography scans were acquired for 11 consecutive patients. The inspiration and expiration data sets were reconstructed using the default phase-based method, as well as a novel respiration percentile-based method with patient-specific metrics to define the ranges of the reconstruction. The image output was analyzed in a blinded fashion for the phase- and percentile-based reconstructions to determine the prevalence and severity of the image artifacts. Results: The percentile-based algorithm resulted in a significant reduction in artifact severity compared with the phase-based algorithm, although the overall artifact prevalence did not differ between the two algorithms. The magnitude of differences in respiratory tag placement between the phase- and percentile-based algorithms correlated with the presence of image artifacts. Conclusion: The results of our study have indicated that our novel four-dimensional computed tomography reconstruction method could be useful in detecting clinically relevant image distortions that might otherwise go unnoticed and to reduce the image distortion associated with some respiratory irregularities. Additional work is necessary to assess the clinical impact on areas of possible irregular breathing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microscopic Gold Particle-Based Fiducial Markers for Proton Therapy of Prostate Cancer

Purpose: We examined the feasibility of using fiducial markers composed of microscopic gold particles and human-compatible polymers as a means to overcome current problems with conventional macroscopic gold fiducial markers, such as dose reduction and artifact generation, in proton therapy for prostate cancer. Methods and Materials: We examined two types of gold particle fiducial marker interactions: that with diagnostic X-rays and with a therapeutic proton beam. That is, we qualitatively and quantitatively compared the radiographic visibility of conventional gold and gold particle fiducial markers and the CT artifacts and dose reduction associated with their use. Results: The gold particle fiducials could be easily distinguished from high-density structures, such as the pelvic bone, in diagnostic X-rays but were nearly transparent to a proton beam. The proton dose distribution was distorted <5% by the gold particle fiducials with a 4.9% normalized gold density; this was the case even in the worst configuration (i.e., parallel alignment with a single-direction proton beam). In addition, CT artifacts were dramatically reduced for the gold particle mixture. Conclusion: Mixtures of microscopic gold particles and human-compatible polymers have excellent potential as fiducial markers for proton therapy for prostate cancer. These include good radiographic visibility, low distortion of the depth-dose distribution, and few CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervix Motion in 50 Cervical Cancer Patients Assessed by Daily Cone Beam Computed Tomographic Imaging of a New Type of Marker

Purpose: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. Methods and Materials: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss. In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. Results: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and −3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and −1.3/4.5/3.6 mm. Conclusions: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of exit beam phase aberrations on parallel beam coherent x-ray reconstructions

Diffraction artifacts from imperfect x-ray windows near the sample are an important consideration in the design of coherent x-ray diffraction measurements. In this study, we used simulated and experimental diffraction patterns in two and three dimensions to explore the effect of phase imperfections in a beryllium window (such as a void or inclusion) on the convergence behavior of phasing algorithms and on the ultimate reconstruction. A predictive relationship between beam wavelength, sample size, and window position was derived to explain the dependence of reconstruction quality on beryllium defect size. Defects corresponding to this prediction cause the most damage to the sample exit wave and induce signature error oscillations during phasing that can be used as a fingerprint of experimental x-ray window artifacts. The relationship between x-ray window imperfection size and coherent x-ray diffractive imaging reconstruction quality explored in this work can play an important role in designing high-resolution in situ coherent imaging instrumentation and will help interpret the phasing behavior of coherent diffraction measured in these in situ environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image segmentation of nanoscale Zernike phase contrast X-ray computed tomography images

Zernike phase contrast is a useful technique for nanoscale X-ray computed tomography (CT) imaging of materials with a low X-ray absorption coefficient. It enhances the image contrast by phase shifting X-ray waves to create changes in amplitude. However, it creates artifacts that hinder the use of traditional image segmentation techniques. We propose an image restoration method that models the X-ray phase contrast optics and the three-dimensional image reconstruction method. We generate artifact-free images through an optimization problem that inverts this model. Though similar approaches have been used for Zernike phase contrast in visible light microscopy, this optimization employs an effective edge detection method tailored to handle Zernike phase contrast artifacts. We characterize this optics-based restoration method by removing the artifacts in and thresholding multiple Zernike phase contrast X-ray CT images to produce segmented results that are consistent with the physical specimens. We quantitatively evaluate and compare our method to other segmentation techniques to demonstrate its high accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A promising limited angular computed tomography reconstruction via segmentation based regional enhancement and total variation minimization

X-ray computed tomography (CT) is a powerful and common inspection technique used for the industrial non-destructive testing. However, large-sized and heavily absorbing objects cause the formation of artifacts because of either the lack of specimen penetration in specific directions or the acquisition of data from only a limited angular range of views. Although the sparse optimization-based methods, such as the total variation (TV) minimization method, can suppress artifacts to some extent, reconstructing the images such that they converge to accurate values remains difficult because of the deficiency in continuous angular data and inconsistency in the projections. To address this problem, we use the idea of regional enhancement of the true values and suppression of the illusory artifacts outside the region to develop an efficient iterative algorithm. This algorithm is based on the combination of regional enhancement of the true values and TV minimization for the limited angular reconstruction. In this algorithm, the segmentation approach is introduced to distinguish the regions of different image knowledge and generate the support mask of the image. A new regularization term, which contains the support knowledge to enhance the true values of the image, is incorporated into the objective function. Then, the proposed optimization model is solved by variable splitting and the alternating direction method efficiently. A compensation approach is also designed to extract useful information from the initial projections and thus reduce false segmentation result and correct the segmentation support and the segmented image. The results obtained from comparing both simulation studies and real CT data set reconstructions indicate that the proposed algorithm generates a more accurate image than do the other reconstruction methods. The experimental results show that this algorithm can produce high-quality reconstructed images for the limited angular reconstruction and suppress the illusory artifacts caused by the deficiency in valid data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AUTOMATED TRANSIENT IDENTIFICATION IN THE DARK ENERGY SURVEY

We describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0% of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm’s performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility. An implementation of the algorithm and the training data used in this paper are available at at http://portal.nersc.gov/project/dessn/autoscan.

79 ASTRONOMY AND ASTROPHYSICS↗