IDC Re-Engineering Phase 2 Iteration E3 Use Cases (Version 1.0)
This document contains 31 use cases generated from the model contained in Rational Software Architect.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This document contains 31 use cases generated from the model contained in Rational Software Architect.
This document contains 21 use cases generated from the model contained in Rational Software Architect.
Due to natural heterogeneity in rock specimens, classifying rock characteristics can present difficulties. 3D printing geo-architectured rock specimens has the potential to reduce the heterogeneity and help evaluate characteristics with reproducible microstructures, bedding, and strength to advance mechanical interpretations. This testing focused on 3D printing effects on strength and rock behavior by varying amount of binder, printing direction, and atmospheric conditions. A powder-based Gypsum 3D printer was used to create 1.5-inch diameter cylindrical samples. Unconfined compressive strength (UCS) testing was completed on these samples to gather failure plots and peak strength. Multiple batches of cylindrical samples were printed with varying printing direction, binder amount, and atmospheric conditions. UCS results show that the strongest samples were those that were printed perpendicular to the loading direction compared to those printed parallel or 45 degrees. Due to reactions of the printing material with water, those at dry conditions were the strongest. Samples with the most binder amount proved to also be stronger than those with less. 3D printing of rock samples has to the potential to reduce heterogeneity rock presents, however additional factors introduced by the printing process can affect overall rock strength and behavior. Test results of the 3D printed geo-architected rock specimens demonstrated reasonable reproducibility and appear to be a promising path towards increasing the ability to characterize natural rock.
The end of Moore’s Law and Dennard Scaling has produced a renaissance in the field of computer architecture. Unable to continue leveraging silicon-level processor improvements to further enhance performance and scalability, system architects have been forced to explore other options. In this new era of heterogeneous architectures and hardware/software codesign, a new class of devices known as “accelerators” has emerged. Independently designed for optimized execution of distinct workloads, these devices have proven critical to the continued advancement of application performance. SmartNICs, accelerator devices integrated with a network controller, have conventionally been utilized to offload low-level networking functionality. However, newer SmartNIC variants, which incorporate a system-on-chip (SoC) with traditional designs, are challenging this precedent. Leveraging significantly augmented resources, these new devices offer increased versatility and the potential to more effectively complement a given architecture’s CPU. In this talk, we introduce the motivation underlying acceleration, explore the fundamentals of SmartNICs, and discuss traditional use cases. We also detail our initial efforts to investigate the feasibility and benefits of SmartNICs as general-purpose accelerators. We present the OpenSNAPI project created to define a uniform application programming interface (API) for this emerging class of devices. Finally, we provide a brief tutorial regarding development of SmartNIC-accelerated applications on Los Alamos National Laboratory’s SmartNIC-enabled platforms.
Building energy modeling (BEM) is a multipurpose tool for building energy efficiency (EE). The U.S. Department of Energy Building Technologies Office (BTO) seeks to expand the use and effectiveness of BEM in the design and operation of commercial and residential buildings with the goal of achieving lasting reductions in total and peak energy use. This report identifies gaps and outlines recommended initiatives to achieve this goal, based on a combination of technical analysis and stakeholder input. In addition to BTO, this report can benefit BEM professionals (architects, mechanical engineers, energy consultants, building auditors, equipment manufacturers, and BEM software vendors) and BEM clients (building owners and operators, EE program administrators, EE service providers, policymakers, and policy and code jurisdictions such as states and cities). This report was developed in two phases. In the first, BTO worked with a team from Navigant Consulting (now Guidehouse) to characterize objectives, opportunities, and current activities; identify gaps and barriers; and define initiatives. To collect input, Navigant conducted telephone interviews and workshops with industry experts. The initial phase produced a draft report, which was released for public review in 2016 and yielded over 400 comments. Based on these comments, BTO compiled a second draft report that addressed many of those comments while acknowledging changes that had occurred both at BTO and in the industry. Unlike the first draft report, the second focused much more heavily on BTO’s own role, portfolio, and activities. BTO is a direct player in the BEM field - it funds the development of several significant software packages that are embedded in commercial products - and transparency about its goals and future plans is requisite. BTO recognizes that a great number of other public and private organizations contribute to the BEM enterprise. With the second draft report, BTO did not attempt to produce a blueprint for the industry as a whole, but rather a working document BTO can use to iteratively solicit stakeholder input and synthesize it into a program. BTO released the second draft report for public review in 2019. The second round of review generated 83 pages of feedback and comments - almost exactly the length of the draft report itself - a significant portion of which was collected and synthesized by IBPSA-USA Advocacy Committee. This final report incorporates this feedback. This report does not address the use of BEM in support of building-based grid services, a recent BTO initiative called Grid-interactive Efficient Buildings (GEB). In 2019, BTO published a report that specifically addresses the role of BEM - and other “integration” technologies - in GEB.
The strategic and economic impacts of high performance computing (HPC) systems, over the last several decades, have enabled dramatic improvements in manufacturing, design, development, and research, across almost every sector of the U.S. economy, including genetic analysis for agriculture and medicine, oil exploration, electronics, aircraft, and automotive design, and of course national defense technologies. HPC has repeatedly compounded reductions in time-to-solution and time-to-market in each of these areas. In recognition of these strategic and economic impacts, the Department of Energy (DOE) created the Exascale Computing Project (ECP) as a broad-based technology project focusing on simultaneously co-evolving high-performance computing architecture, system software, and application software. While many details of the exascale architectures are undefined, communicating the form and direction of this co-evolution of advances, in each of these three components, across the project, presents a need for a common language through which these advances can be shared. In this document we present a series of abstract representations designed to allow application developers to focus on the aspects of the machine that are important or relevant to performance and code structure. These abstract machine models (AMMs) describe the proposed architectures at the component and system level and are intended as communication aids between application developers and hardware architects during the co-design process. In addition to providing a common language for communication, the constraints of protecting the intellectual property of ECP’s vendor partners requires that the architectural advances be presented in an abstract sense, rather than exposing the specifics of an individual vendor’s designs, while still providing enough detail such that application developers will be able to reason about the performance trade-offs in the design space of their applications.
This guide was developed with partners throughout the United States to demonstrate how implementing district-scale high-performance strategies can be successful and scalable approaches to achieving deep energy savings that increase affordability, improve resilience, reduce emissions, and foster economic development. This document serves as a framework for districts, campuses, and communities, illustrating an iterative process of building support for, planning, and implementing high-performance districts by engaging stakeholders, setting aggressive energy goals, completing technical and financial planning, and implementing a high-performance energy master plan. The information in this guide is based on a 3-year U.S. Department of Energy Zero Energy District Accelerator and a range of real-world examples of emerging high-performance districts. It is particularly useful for architects, planners, engineers, local government agencies, and real estate developers in the early phases of planning a district with high-performance or other deep energy goals. For the purposes of this guide, a high-performance district is a multibuilding development that achieves aggressive energy and related goals such as zero energy, carbon neutrality, sustainability, ultra-efficiency, etc. High-performance districts optimize energy efficiency to reduce energy loads and use renewable energy resources to meet the remaining loads whenever possible. The Energy Independence and Security Act of 2007 defines a high-performance building as “a building that integrates and optimizes on a life cycle basis all major high-performance attributes, including energy conservation, environment, safety, security, durability, accessibility, cost-benefit, productivity, sustainability, functionality, and operational considerations.” High-performance districts are collections of such buildings that take advantage of the synergies available when energy consumption and production are considered at a district level rather than one building at a time.
This document contains 21 use cases generated from the model contained in Rational Software Architect.
This document contains 10 use cases generated from the model contained in Rational Software Architect.
This document contains 4 use case realizations generated from the model contained in Rational Software Architect.
This document contains 6 use cases generated from the model contained in Rational Software Architect.
This document contains 1 use case generated from the model contained in Rational Software Architect.
This document contains 1 use cases generated from the model contained in Rational Software Architect.
This document contains 10 use cases generated from the model contained in Rational Software Architect.
This document contains 10 use cases generated from the rnodel contained in Rational Software Architect.
This document contains 4 use case realizations generated from the model contained in Rational Software Architect.
The assurance of Safeguards Information is crucial to meet IAEA obligations. Information can be potentially at risk for alteration when it is generated, stored, transmitted, or manipulated (such as in a calculation). Where, when, and how information is assured can vary depending on where in the information lifecycle it exists. Often, information protection measures are not considered until after a system is architected and built or are only applied to a portion of the information system. This typically limits the effectiveness of information assurance, can increase the cost of assuring the information, and can reduce the trust in the information received. Designing information assurance into the architecture of a system can significantly reduce information vulnerability at an affordable cost while improving the trust of the information. This paper discusses safeguards information assurance by design and architectural approaches from a lifecycle perspective including potential tools that can be utilized to help define information assurance requirements and help validate the effectiveness of these requirements as the system transitions through the lifecycle. The tools discussed include risk management tools, architectural approaches, modeling approaches, and red teaming benefits.
In this position paper we will address challenges and opportunities relating to the design and codesign of application specific circuits. Given our background as computational scientists, our perspective is from the viewpoint of a highly motivated application developer as opposed to career computer architects