Aperture-coupled thin-membrane microstrip array antenna for beam scanning application

A microstrip array using aperture-slot-coupling technique with very thin membranes has been developed at the L-band frequency for beam scanning application. This technology-demonstration array with 4 x 2 elements achieved a relatively wide bandwidth of 100 MHz (8%) and +/-45(deg) beam scan. Very narrow coupling slots were used with each having an aspect ratio of 160 (conventional slot aspect ratio is between 10 to 30) for coupling through very thin membrane (0.05mm thickness). This thin-membrane aperture-coupling technique allows the array antenna elements to be more easily integrated with transmit/receive amplifier (T/R) and phase shifter modules. This paper addresses only the radiator portion of the array. The array and active components will be presented in a separate pape.

array antenna↗

Initial Technology Assessment for the Large-Aperture UV-Optical-Infrared (LUVOIR) Mission Concept Study

The NASA Astrophysics Division's 30-Year Roadmap prioritized a future large-aperture space telescope operating in the ultra-violet/optical/infrared wavelength regime. The Association of Universities for Research in Astronomy envisioned a similar observatory, the High Definition Space Telescope. And a multi-institution group also studied the Advanced Technology Large Aperture Space Telescope. In all three cases, a broad science case is outlined, combining general astrophysics with the search for biosignatures via direct-imaging and spectroscopic characterization of habitable exoplanets. We present an initial technology assessment that enables such an observatory that is currently being studied for the 2020 Decadal Survey by the Large UV/Optical/Infrared (LUVOIR) surveyor Science and Technology Definition Team. We present here the technology prioritization for the 2016 technology cycle and define the required technology capabilities and current state-of-the-art performance. Current, planned, and recommended technology development efforts are also reported.

technology development↗

VLTI-AMBER Velocity-Resolved Aperture-Synthesis Imaging of Eta Carinae with a Spectral Resolution of 12 000: Studies of the Primary Star Wind and Innermost Wind-Wind Collision Zone

The mass loss from massive stars is not understood well. Eta Carinae is a unique object for studying the massive stellar wind during the luminous blue variable phase. It is also an eccentric binary with a period of 5.54 yr. The nature of both stars is uncertain, although we know from X-ray studies that there is a wind-wind collision whose properties change with orbital phase. Aims. We want to investigate the structure and kinematics of Car's primary star wind and wind-wind collision zone with a high spatial resolution of approx.6 mas (approx.14 au) and high spectral resolution of R = 12 000. Methods. Observations of Car were carried out with the ESO Very Large Telescope Interferometer (VLTI) and the AMBER instrument between approximately five and seven months before the August 2014 periastron passage. Velocity-resolved aperture-synthesis images were reconstructed from the spectrally dispersed interferograms. Interferometric studies can provide information on the binary orbit, the primary wind, and the wind collision. Results. We present velocity-resolved aperture-synthesis images reconstructed in more than 100 di erent spectral channels distributed across the Br(gamma) 2.166 micron emission line. The intensity distribution of the images strongly depends on wavelength. At wavelengths corresponding to radial velocities of approximately -140 to -376 km/s measured relative to line center, the intensity distribution has a fan-shaped structure. At the velocity of -277 km/s, the position angle of the symmetry axis of the fan is 126. The fan-shaped structure extends approximately 8.0 mas (approx.18:8 au) to the southeast and 5.8 mas (approx.13:6 au) to the northwest, measured along the symmetry axis at the 16% intensity contour. The shape of the intensity distributions suggests that the obtained images are the first direct images of the innermost wind-wind collision zone. Therefore, the observations provide velocity-dependent image structures that can be used to test three-dimensional hydrodynamical, radiative transfer models of the massive interacting winds of Eta Car.

Velocity-resolved aperture-synthesis images↗

Design and performance analysis of a PIAACMC coronagraph on a segmented aperture

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) offers high throughput and small inner working angle (IWA) for direct imaging of exoplanets. PIAACMC is also compatible with segmented apertures, which is important for the success of future large telescopes, such as the Large UV / Optical/ Infrared (LUVOIR) concept currently under way to inform NASA's2020 decadal survey. We present a design of PIAACMC for one of the segmented apertures considered for LUVOIR and simulate its performance with wavefront control, in monochromatic as well as broadband light. We characterize its performance in terms of throughput, inner working angle, contrast, area of the dark zone, and sensitivity to low order aberrations, in particular tip/tilt. In addition, we study the resilience to large stellar angular sizes and polarization. Finally, we compute the "performance map", which is a recently introduced figure of merit for coronagraphs

Exoplanets↗

P-band Antenna Array for NASA's Space Exploration Synthetic Aperture Radar (SESAR) Instrument

A dual-polarized, wideband, lightweight P-band (435 MHz) antenna element and array for spaceborne radar applications has been developed for NASA’s SESAR (Space Exploration Synthetic Aperture Radar) instrument for planetary synthetic aperture radar (SAR) applications. The antenna array is based on lightweight, low-profile antenna elements that form the building blocks of configurable “array panels” that can in turn be used to build larger arrays consisting of multiple panels. The element design combines a novel, mostly planar conductor antenna element geometry with a robust lightweight composite material construction.

Synthetic Aperture Radar↗

Evaluating the dynamic aperture evaluation for the new RHIC 250 GeV polarized proton lattice

To increase luminosity in the Relativistic Heavy Ion Collider's (RHIC's) polarized proton 250 GeV operations, we are considering reducing {beta}* to 0.65 m at the interaction points (IPs), and increasing bunch intensity. The new working point near the 2/3 integer will used on the ramp to preserve polarization. In addition, we plan to adjust the betatron-phase advances between IP6 and IP8 to (k+1/2)*{pi} so to lower the dynamic beta-beat from the beam-beam interaction. The effects of all these changes will impact the dynamic aperture, and hence, it must be evaluated carefully. In this article, we present the results of tracking the dynamic aperture with the proposed lattices.

43 PARTICLE ACCELERATORS↗

Results from the Coded Aperture Neutron Imaging System (CANIS).

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging- a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the coded aperture neutron imaging system.

Because of their penetrating power, energetic neutrons and gamma rays ({approx}1 MeV) offer the best possibility of detecting highly shielded or distant special nuclear material (SNM). Of these, fast neutrons offer the greatest advantage due to their very low and well understood natural background. We are investigating a new approach to fast-neutron imaging - a coded aperture neutron imaging system (CANIS). Coded aperture neutron imaging should offer a highly efficient solution for improved detection speed, range, and sensitivity. We have demonstrated fast neutron and gamma ray imaging with several different configurations of coded masks patterns and detectors including an 'active' mask that is composed of neutron detectors. Here we describe our prototype detector and present some initial results from laboratory tests and demonstrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Aperture center energy showcase

Sandia and Forest City have established a Cooperative Research and Development Agreement (CRADA), and the partnership provides a unique opportunity to take technology research and development from demonstration to application in a sustainable community. A project under that CRADA, Aperture Center Energy Showcase, offers a means to develop exhibits and demonstrations that present feedback to community members, Sandia customers, and visitors. The technologies included in the showcase focus on renewable energy and its efficiency, and resilience. These technologies are generally scalable, and provide secure, efficient solutions to energy production, delivery, and usage. In addition to establishing an Energy Showcase, support offices and conference capabilities that facilitate research, collaboration, and demonstration were created. The Aperture Center project focuses on establishing a location that provides outreach, awareness, and demonstration of research findings, emerging technologies, and project developments to Sandia customers, visitors, and Mesa del Sol community members.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Beam's-Eye-View Dosimetrics-Guided Inverse Planning for Aperture-Modulated Arc Therapy

Purpose: To use angular beam's-eye-view dosimetrics (BEVD) information to improve the computational efficiency and plan quality of inverse planning of aperture-modulated arc therapy (AMAT). Methods and Materials: In BEVD-guided inverse planning, the angular space spanned by a rotational arc is represented by a large number of fixed-gantry beams with angular spacing of approx2.5 degrees. Each beam is assigned with an initial aperture shape determined by the beam's-eye-view (BEV) projection of the planning target volume (PTV) and an initial weight. Instead of setting the beam weights arbitrarily, which slows down the subsequent optimization process and may result in a suboptimal solution, a priori knowledge about the quality of the beam directions derived from a BEVD is adopted to initialize the weights. In the BEVD calculation, a higher score is assigned to directions that allow more dose to be delivered to the PTV without exceeding the dose tolerances of the organs at risk (OARs) and vice versa. Simulated annealing is then used to optimize the segment shapes and weights. The BEVD-guided inverse planning is demonstrated by using two clinical cases, and the results are compared with those of a conventional approach without BEVD guidance. Results: An a priori knowledge-guided inverse planning scheme for AMAT is established. The inclusion of BEVD guidance significantly improves the convergence behavior of AMAT inverse planning and results in much better OAR sparing as compared with the conventional approach. Conclusions: BEVD-guidance facilitates AMAT treatment planning and provides a comprehensive tool to maximally use the technical capacity of the new arc therapeutic modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High‐resolution experiments on chemical oxidation of DNAPL in variable‐aperture fractures

Abstract Chemical oxidation of dense nonaqueous‐phase liquids (DNAPLs) by permanganate has emerged as an effective remediation strategy in fractured rock. We present high‐resolution experimental investigations in transparent analog variable‐aperture fractures to improve understanding of chemical oxidation of residual entrapped trichloroethylene (TCE) in fractures. Four experiments were performed with different permanganate concentrations, flow rates, and initial TCE phase geometry. The initial aperture field and evolving entrapped‐phase geometry were quantified for each experiment. The integrated mass transfer rate from the TCE phase for all experiments exhibited three time regimes: an early‐time regime with slower mass transfer rates limited by low specific interfacial area; an intermediate‐time regime with higher mass transfer rates resulting from breakup of large TCE blobs, which greatly increases specific interfacial area; and a late‐time regime with low mass transfer rates due to the deposition of MnO 2 precipitates. In two experiments, mass balance analyses suggested that TCE mass removal rates exceeded the maximum upper bound mass removal rates derived by assuming that oxidation and dissolution are the only mechanisms for TCE mass removal. We propose incomplete oxidation by permanganate and TCE solubility enhancement by intermediate reaction products as potential mechanisms to explain this behavior. We also speculate that some intermediate reaction products with surfactant‐like properties may play a role in lowering the TCE‐water interfacial tension, thus causing breakup of large TCE blobs. Our quantitative experimental measurements will be useful in the context of developing accurate computational models for chemical oxidation of TCE in fractures.

Arshadi, Masoud↗

Method of Green’s Potentials for Elliptic PDEs in Domains with Random Apertures

Problems with topological uncertainties appear in many fields ranging from nano-device engineering to the design of bridges. In many of such problems, a part of the domains boundaries is subjected to random perturbations making inefficient conventional schemes that rely on discretization of the whole domain. Here, we study elliptic PDEs in domains with boundaries comprised of a deterministic part and random apertures, and apply the method of modified potentials with Green’s kernels defined on the deterministic part of the domain. This approach allows to reduce the dimension of the original differential problem by reformulating it as a boundary integral equation posed on the random apertures only. The multilevel Monte Carlo method is then applied to this modified integral equation and its optimal ϵ -2 asymptotical complexity is shown. Finally, we provide the qualitative analysis of the proposed technique and support it with numerical results.

97 MATHEMATICS AND COMPUTING↗

Relating Hydro–Mechanical and Elastodynamic Properties of Dynamically Stressed Tensile–Fractured Rock in Relation to Applied Normal Stress, Fracture Aperture, and Contact Area

We exploit nonlinear elastodynamic properties of fractured rock to probe the micro-scale mechanics of fractures and understand the relation between fluid transport and fracture aperture under dynamic stressing. Experiments were conducted on rough, tensile-fractured Westerly granite subject to triaxial stresses. We measure fracture permeability for steady-state fluid flow with deionized water. Pore pressure oscillations are applied at amplitudes ranging from 0.2 to 1 MPa at 1 Hz frequency. During dynamic stressing we transmit ultrasonic signals through the fracture using an array of piezoelectric transducers (PZTs) to monitor evolution of interface properties. We examine the influence of fracture aperture and contact area by conducting measurements at effective normal stresses of 10–20 MPa. Additionally, the evolution of contact area with stress is characterized using pressure sensitive film. These experiments are conducted separately with the same fracture and map contact area at stresses from 9 to 21 MPa. The measurements are a proxy for “true” contact area for the fracture surface and we relate them to elastic properties using the calculated PZT sensor footprints via numerical modeling of Fresnel zones. We compare the elastodynamic response of the fracture using the stress-induced changes in ultrasonic wave velocities for transmitter-receiver pairs to image spatial variations in contact properties. We show that nonlinear elasticity and permeability enhancement decrease with increasing normal stress. Additionally, post-oscillation wave velocity and permeability exhibit quick recoveries toward pre-oscillation values. Estimates of fracture contact area (global and local) demonstrate that the elastodynamic and permeability responses are dominated by fracture topology.

58 GEOSCIENCES↗

Complex Electrical Conductivity of a Single‐Fractured Rock: Fracture‐and‐Matrix Coupling Mechanism and Aperture Size Predictions

Fractured rocks play a crucial role in myriad natural and engineered systems, including Earth's critical zone, oil/gas/geothermal reservoirs, and geological CO 2 /H 2 /waste storage systems. While complex electrical conductivity is extensively used to estimate the pore and grain sizes of conventional porous rocks and soils, it is rarely used to predict the aperture size of fractured rocks and this remains poorly understood. Here, integrating theory, simulations, and experiments, we show that under external fields, fractured rocks follow the fracture-and-matrix coupling to make the bulk complex conductivity non-linear with respect to water conductivity. We find that the relaxation time and quadrature conductivity for porous media do not apply to fractured rocks, but, instead, reasonably accurate predictions of aperture size can be made based on the true formation factor. This study unravels the fundamental mechanism governing conduction and polarization of fractured rocks and paves the way for the non-invasive investigation of global fractured rocks.

58 GEOSCIENCES↗

Beam optics in a MeV-class multi-aperture multi-grid accelerator for the ITER neutral beam injector

In a multi-aperture multi-grid accelerator of the ITER neutral beam injector, the beamlets are deflected due to space charge repulsion between beamlets and beam groups, and also due to magnetic field. Moreover, the beamlet deflection is influenced by electric field distortion generated by grid support structure. Such complicated beamlet deflections and the compensations have been examined utilizing a three-dimensional beam analysis. The space charge repulsion and the influence by the grid support structure were studied in a 1/4 model of the accelerator including 320 beamlets. Beamlet deflection due to the magnetic field was studied by a single beamlet model. As the results, compensation methods of the beamlet deflection were designed, so as to utilize a metal bar (so-called field shaping plate) of 1 mm thick beneath the electron suppression grid (ESG), and an aperture offset of 1 mm in the ESG.

43 PARTICLE ACCELERATORS↗

A new aperture for neutron and x-ray imaging of inertial confinement fusion experiments

Recent neutron imaging of experiments at the National Ignition Facility has provided useful information about the hotspot shape and cold-fuel distribution and has also given insight into avenues for improvement. Neutron image reconstruction depends on accurate pointing information because the point-spread function of the neutron aperture is not shift invariant. Current pointing techniques are limited in their accuracy and rely upon detailed information about the as-built structure of the array, which is difficult to determine. We present a technique for extracting high-precision pointing information from both neutron and x-ray images, and a new aperture design with features to facilitate this technique, and allow future co-registration of neutron and x-ray images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aperture-based antihydrogen gravity experiment: Parallel plate geometry

An analytical model and a Monte Carlo simulation are presented of an experiment that could be used to determine the direction of the acceleration of antihydrogen due to gravity. The experiment would rely on methods developed by existing antihydrogen research collaborations. The configuration consists of two circular, parallel plates that have an axis of symmetry directed away from the center of the earth. The plates are separated by a small vertical distance, and include one or more pairs of circular barriers that protrude from the upper and lower plates, thereby forming an aperture between the plates. Antihydrogen annihilations that occur just beyond each barrier, within a “shadow” region, are asymmetric on the upper plate relative to the lower plate. The probability for such annihilations is determined for a point, line and spheroidal source of antihydrogen. The production of 100,000 antiatoms is predicted to be necessary for the aperture-based experiment to indicate the direction of free fall acceleration of antimatter, provided that antihydrogen is produced within a sufficiently small antiproton plasma at a temperature of 4 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras

A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30–40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.