Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Long mean free paths of room-temperature THz acoustic phonons in a high thermal conductivity material

We report measurements of room-temperature mean free paths of long-lived THz acoustic phonons in wurtzite GaN. Longitudinal phonon wave packets are excited and probed by femtosecond laser pulses in two InGaN-GaN multiple quantum well structures separated by a GaN layer. By measuring the temperature dependence of the phonon attenuation in the range 80–300 K we isolate the intrinsic phonon mean free path at 300 K which is found to be 5.3 and 3.5 μm at 1.06 and 1.43 THz, respectively. The measurements are found to be in good agreement with ab initio calculations which show that the main channel of the acoustic phonon decay is a three-phonon scattering process involving the acoustic phonon and two high-frequency optical phonons. Here, our results indicate that the contribution of low-THz acoustic phonons to thermal transport in GaN is relatively smaller than in Si; thus finite size effects are expected to be less important in GaN.

36 MATERIALS SCIENCE↗

Strong enhancement of surface diffusion by nonlinear surface acoustic waves

The phenomenon of acoustic activation of surface diffusion is investigated in a combined computational and experimental study. The ability of pulsed laser-generated surface acoustic waves (SAWs) to enhance the mobility of small atomic clusters is demonstrated by directly tracking, with fluorescence microscopy, individual Au 8 clusters moving on a (111) silicon substrate. In this work, a 19-fold increase in the effective diffusion coefficient is measured in room temperature experiments in the presence of SAWs generated by nanosecond pulse laser irradiation at a 100 Hz repetition rate. A strong enhancement of cluster mobility by SAWs is also observed in large-scale molecular dynamics simulations of surface diffusion of small atomic clusters. The analysis of the computational results demonstrates that the nonlinear sharpening of SAWs and the corresponding enrichment of the SAW spectra by high frequency harmonics which are capable of dynamic coupling to the cluster vibrations are responsible for the efficient acoustic activation of surface mobility in the simulations. The increase in the effective diffusion coefficient is proportional to the number of the SAW pulses passing through the diffusion region per unit time and a dramatic 4500-fold diffusion enhancement (corresponds to an equivalent temperature increase by ~10 3 K ) is predicted in the simulations for 15 GHz SAWs. The ability of SAWs to affect atomic-level surface processes has far-reaching implications for the design of new techniques where the acoustic energy serves as an effective substitution for thermal activation in applications where heating must be avoided or rapid switching of surface conditions is required.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Testing H 0 in Acoustic Dark Energy with Planck and ACT Polarization

The canonical acoustic dark energy model (cADE), which is based on a scalar field with a canonical kinetic term that rapidly converts potential to kinetic energy around matter radiation equality, alleviates the Hubble tension found in ΛCDM. Here, we show that it successfully passes new consistency tests in the CMB damping tail provided by the ACT data, while being increasingly constrained and distinguished from alternate mechanisms by the improved CMB acoustic polarization data from Planck. The best fit cADE model to a suite of cosmological observations, including the SH0ES H 0 measurement, has H 0 = 70.25 compared with 68.23 (km s –1 Mpc –1 ) in ΛCDM and a finite cADE component is preferred at the 2.8σ level. The ability to raise H0 is now mainly constrained by the improved Planck acoustic polarization data, which also plays a crucial role in distinguishing cADE from the wider class of early dark energy models. ACT and Planck TE polarization data are currently mildly discrepant in normalization and drive correspondingly different preferences in parameters. Improved constraints on intermediate scale polarization approaching the cosmic variance limit will be an incisive test of the acoustic dynamics of these models and their alternatives.

79 ASTRONOMY AND ASTROPHYSICS↗

Acoustic metric of the compressible draining bathtub

The draining bathtub flow, a cornerstone in the theory of acoustic black holes, is here extended to the case of exact solutions for compressible nonviscous flows characterized by a polytropic equation of state. Investigating the analytical configurations obtained for selected values of the polytropic index, it is found that each of them becomes nonphysical at the so called limiting circle. By studying the null geodesics structure of the corresponding acoustic line elements, it is shown that such a geometrical locus coincides with the acoustic event horizon. This region is characterized also by an infinite value of space-time curvature, so the acoustic analogy breaks down there. Possible applications for artificial and natural vortices are finally discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hardware-Efficient Quantum Random Access Memory with Hybrid Quantum Acoustic Systems

Hybrid quantum systems in which acoustic resonators couple to superconducting qubits are promising quantum information platforms. High quality factors and small mode volumes make acoustic modes ideal quantum memories, while the qubit-phonon coupling enables the initialization and manipulation of quantum states. In this paper, we present a scheme for quantum computing with multimode quantum acoustic systems, and based on this scheme, propose a hardware-efficient implementation of a quantum random access memory (QRAM). Quantum information is stored in high-$\textit{Q}$ phonon modes, and couplings between modes are engineered by applying off-resonant drives to a transmon qubit. In comparison to existing proposals that involve directly exciting the qubit, this scheme can offer a substantial improvement in gate fidelity for long-lived acoustic modes. We show how these engineered phonon-phonon couplings can be used to access data in superposition according to the state of designated address modes—implementing a QRAM on a single chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗

Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography

Purpose: An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. Methods: Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. Results: By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. Conclusions: The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-14: A Comparative Study Between Forward and Inverse Planning in Gamma Knife Radiosurgery for Acoustic Neuroma Tumours

Purpose: To evaluate forward and inverse planning methods for acoustic neuroma cases treated in Gamma Knife Perfexion. Methods: Five patients with acoustic neuroma tumour abutting brainstem were planned twice in LGP TPS (Version 10.1) using TMR10 algorithm. First plan was entirely based on forward planning (FP) in which each shot was chosen manually. Second plan was generated using inverse planning (IP) for which planning parameters like coverage, selectivity, gradient index (GI) and beam-on time threshold were set. Number of shots in IP was automatically selected by objective function using iterative process. In both planning methods MRI MPRAGE sequence images were used for tumour localization and planning. A planning dose of 12Gy at 50% isodose level was chosen. Results and Discussion: Number of shots used in FP was greater than IP and beam-on time in FP was in average 1.4 times more than IP. One advantage of FP was that the brainstem volume subjected to 6Gy dose (25% isodose) was less in FP than IP. Our results showed use of more number of shots as in FP results in GI less than or equal to 2.55 which is close to its lower limit. Dose homogeneity index (DHI) analysis of FP and IP showed average values of 0.59 and 0.67 respectively. General trend in GK for planning in acoustic neuroma cases is to use small collimator shots to avoid dose to adjacent critical structures. More number of shots and prolonged treatment time causes inconvenience to the patients. Similarly overuse of automatic shot shaping as in IP results in increased scatter dose. A compromise is required in shot selection for these cases. Conclusion: IP method could be used in acoustic neuroma cases to decrease treatment time provided the source sector openings near brainstem are shielded or adjusted appropriately to reduce brainstem dose.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-01: Acoustic Range Verification of Proton Beams: Simulation of Heterogeneity and Clinical Proton Pulses

Purpose: Through simulation, to assess acoustic-based range verification of proton beams (protoacoustics) under clinical conditions. Methods: Pressure waves generated by the energy deposition of a 150 MeV, 8 mm FWHM pulsed pencil proton beam were numerically simulated through two Methods: 1) For a homogeneous water medium, an analytical wave-equation solution was used to calculate the time-dependent pressure measured at detector points surrounding the proton Bragg peak. 2) For heterogeneity studies, a CT tissue image was used to calculate the proton dose deposition and define the acoustic properties of the voxels through which numerical pressure wave propagation was simulated with the k-Wave matlab toolbox. The simulations were used to assess the dependence of the acoustic amplitude and range-verification accuracy on proton pulse rise time and tissue heterogeneity. Results: As the proton pulse rise time is increased from 1 to 40 µs, the amplitude of the expected acoustic emission decreases (a 60% drop distal to the Bragg peak), the central frequency of the expected signal decreases (from 45 to 6 kHz), and the accuracy of the range-verification decreases (from <1 mm to 16 mm at 5 cm distal to the Bragg peak). For a 300 nA pulse, the expected pressure range is on the order of 0.1 Pa, which is observable with commercial detectors. For the heterogeneous medium, our test case shows that pressure waves emitted by an anterior pencil beam directed into the abdomen and detected posteriorly can determine the Bragg peak range to an accuracy of <2mm for a 1 µs proton pulse. Conclusion: For proton pulses with fast rise-times, protoacoustics is a promising potential method for monitoring penetration depth through heterogeneous tissue. The loss of range-verification accuracy with increasing rise-times, however, suggests the need for comparisons to modeling to improve accuracy for slower cyclotron proton sources.

07 ISOTOPE AND RADIATION SOURCES↗

Topographic effects on reflected acoustic waves from the OSIRIS-REx reentry observed from stratospheric balloons

During long-distance sound propagation in planetary atmospheres, acoustic waves may reflect off the air/surface interface one or more times. For low sound frequencies and flat interfaces, the incident and reflected wave tend to be nearly identical. However, this may not be the case when the downgoing acoustic wave encounters topography. Here, we describe a set of direct and reflected acoustic signals recorded on free-flying balloons during the hypersonic entry of the OSIRIS-REx sample return capsule (SRC). In two of the three cases presented here, an impulsive reflected arrival similar in form to the direct sonic boom of the SRC is observed, followed by a diffuse coda. In contrast, one of the floating stations lacked an impulsive reflection entirely, with only the coda present. We use full waveform modeling to show how reflection in the presence of complex topography can explain coda seen in all three examples as well as the lack of impulsive arrival on the third. Our results indicate that the complex signals often observed in long range acoustic propagation could be due, in part, to interactions with topography during transmission.

Lees, Jonathan M. [University of North Carolina, C↗

Operando Acoustic Monitoring of SEI Formation and Long-Term Cycling in NMC/SiGr Composite Pouch Cells

Stable long-term cycling and solid-electrolyte-interphase (SEI) formation are key challenges in the design of Si/graphite composites as Li-ion battery (LIB) anode materials. Typically, these long-term cycling properties are examined in flooded half-cell settings making use of a Li-metal counter electrode and a Si/graphite working electrode. This form factor has the advantage of offering an unlimited supply of Li-ions and electrolyte, thus isolating performance degradation to the passivation of the working electrode. However, half-cell studies are ineffective in revealing performance and degradation mechanisms of the Si/graphite composite in a more commercially realistic full cell setting. This paper outlines an operando acoustic technique that can offer insights on SEI formation and capacity degradation of Si/graphite composites in a full cell setting. Through a combination of electrochemical and chemical analyses, we show that increasing passivation of the silicon particles in the Si/graphite composite anode is correlated with an increase in the acoustic time-of-flight shift. We further show that temporary loss of the acoustic signal during the first cycle is associated with significant gassing of the cell. The operando acoustic technique outlined here is low-cost, simple to setup and has the potential for localized resolution, indicating usefulness in commercial-scale Si/graphite cell quality control and diagnosis.

42 ENGINEERING↗

Crack Propagation Analysis Using Acoustic Emission Sensors for Structural Health Monitoring Systems

Aerospace systems are expected to remain in service well beyond their designed life. Consequently, maintenance is an important issue. A novel method of implementing artificial neural networks and acoustic emission sensors to form a structural health monitoring (SHM) system for aerospace inspection routines was the focus of this research. Simple structural elements, consisting of flat aluminum plates of AL 2024‐T3, were subjected to increasing static tensile loading. As the loading increased, designed cracks extended in length, releasing strain waves in the process. Strain wave signals, measured by acoustic emission sensors, were further analyzed in post‐processing by artificial neural networks (ANN). Several experiments were performed to determine the severity and location of the crack extensions in the structure. ANNs were trained on a portion of the data acquired by the sensors and the ANNs were then validated with the remaining data. The combination of a system of acoustic emission sensors, and an ANN could determine crack extension accurately. The difference between predicted and actual crack extensions was determined to be between 0.004 in. and 0.015 in. with 95% confidence. These ANNs, coupled with acoustic emission sensors, showed promise for the creation of an SHM system for aerospace systems.

42 ENGINEERING↗

ATom (Acoustic Tomography Processing Suite) [SWR-24-120]

Acoustic tomography seeks the best-fit fluctuating velocity and temperature fields that explain a collection of signal travel times in a region of interest. This codebase defines an end-to-end framework for executing turbulent field retrievals from acoustic signals, acoustic signal design and processing tools for the physical array, and analysis tool that leverage virtual acoustic tomography arrays based on large-eddy simulations of the atmospheric boundary layer.

Hamilton, Nicholas↗

Vibro-acoustic modulation and data fusion for localizing alkali–silica reaction–induced damage in concrete

This article investigates the application of vibro-acoustic modulation testing for diagnosing damage in concrete structures. The vibro-acoustic modulation technique employs two excitation frequencies on a structure. The interaction of these excitations in the measured response indicates damage through the presence of sidebands in the frequency spectra. Past studies using this technique have mostly focused on metals and composites (thin plates or laminates). Our research focuses on concrete, which is a highly heterogeneous material susceptible to a variety of chemical, physical, and mechanical damage processes. In particular, this article investigates diagnosing cracking in concrete from an expansive gel produced by an alkali–silica reaction in the presence of moisture. Past studies have been limited to damage detection using vibro-acoustic modulation testing, whereas this article extends the technique to damage localization. A cement slab with pockets of reactive aggregate is used to investigate the diagnosis technique. The effects of different testing parameters, such as locations, magnitudes, and frequencies of the two excitations, are analyzed and incorporated in the damage localization methodology. A Bayesian probabilistic methodology is developed to fuse the information from multiple test configurations in order to construct damage probability maps for the test specimen. The results of vibro-acoustic modulation–based damage localization are validated by petrographic study of cores taken from the slab.

Karve, Pranav↗

Vitality models found useful in modeling tag-failure times in acoustic-tag survival studies

Abstract Acoustic telemetry studies often rely on the assumption that premature tag failure does not affect the validity of inferences. However, in some cases this assumption is possibly or likely invalid and it is necessary to apply a correction to estimation procedures. The question of which approaches and specific models are best suited to modeling acoustic tag failures has received little research attention. In this short communication, we present a meta-analysis of 42 acoustic tag-life studies, originally used to correct survival studies involving outmigrating juvenile salmonids in the Columbia/Snake river basin. We compare the performance of nine alternative parametric models including common failure–time/survival models and the vitality models of Li and Anderson Theor Popul Biol 76:118–131, (2009) and Demogr Res 28:341–372, (2013). The tag-life studies used acoustic tags from three different tag manufacturers, had expected lifetimes between 12 and 61 days, and had dry weights ranging from 0.22 to 1.65 g. In 57% of the cases, the vitality models of Li and Anderson Theor Popul Biol 76:118–131, (2009) and Demogr Res 28:341–372, (2013) fit the tag-failure times best. The vitality models were also the second-best choices in 17% of the cases. Together, the vitality models, log-logistic, (19%), and gamma models (14%) accounted for 90% of the models selected. Unlike more traditional failure–time models (e.g., Weibull, Gompertz, gamma, and log-logistic), the vitality models are capable of characterizing both the early onset of tag failure due to manufacturing errors and the anticipated battery life. We provide further guidance on appropriate sample sizes (50–100 tags) and procedures to be considered when applying precise tag-life corrections in release–recapture survival studies.

Skalski, John R. (ORCID:0000000270702505)↗

Studies of elasticity, sound propagation and attenuation of acoustic modes in granular media: final report

This is the final report describing the results of DOE Grant # DE-FG02-03ER15458 with original termination date of April 31, 2013, which has been extended to April 31, 2014. The goal of this project is to develop a theoretical and experimental understanding of sound propagation, elasticity and dissipation in granular materials. The topic is relevant for the efficient production of hydrocarbon and for identifying and characterizing the underground formation for storage of either CO 2 or nuclear waste material. Furthermore, understanding the basic properties of acoustic propagation in granular media is of importance not only to the energy industry, but also to the pharmaceutical, chemical and agricultural industries. We employ a set of experimental, theoretical and computational tools to develop a study of acoustics and dissipation in granular media. These include the concept effective mass of granular media, normal modes analysis, statistical mechanics frameworks and numerical simulations based on Discrete Element Methods. Effective mass measurements allow us to study the mechanisms of the elastic response and attenuation of acoustic modes in granular media. We perform experiments and simulations under varying conditions, including humidity and vacuum, and different interparticle force-laws to develop a fundamental understanding of the mechanisms of damping and acoustic propagation in granular media. A theoretical statistical approach studies the necessary phase space of configurations in pressure, volume fraction to classify granular materials.

58 GEOSCIENCES↗

Ionospheric acoustic and gravity wave activity above low-latitude thunderstorms

In this report, we study the correlation between thunderstorm activity and ionospheric gravity and acoustic waves in the low-latitude ionosphere. We use ionospheric total electron content (TEC) measurements from the Low Latitude Ionospheric Sensor Network (LISN) and lightning measurements from the World- Wide Lightning Location Network (WWLLN). We find that ionospheric acoustic waves show a strong diurnal pattern in summer, peaking in the pre-midnight time period. However, the peak magnitude does not correspond to thunderstorm area, and the peak time is significantly after the peak in thunderstorm activity. Wintertime acoustic wave activity has no discernable pattern in these data. The coverage area of ionospheric gravity waves in the summer was found to increase with increasing thunderstorm activity. Wintertime gravity wave activity has an observable diurnal pattern unrelated to thunderstorm activity. These findings show that while thunderstorms are not the only, or dominant source of ionospheric perturbations at low-latitudes, they do have an observable effect on gravity wave activity and could be influential in acoustic wave activity.

58 GEOSCIENCES↗

Report on Non-invasive acoustic monitoring of D2O concentration Oct 31 2017

There is an urgent need for real-time monitoring of the hydrogen /deuterium ratio (H/D) for heavy water production monitoring. Based upon published literature, sound speed is sensitive to the deuterium content of heavy water and can be measured using existing acoustic methods to determine the deuterium concentration in heavy water solutions. We plan to adapt existing non-invasive acoustic techniques (Swept-Frequency Acoustic Interferometry and Gaussian-pulse acoustic technique) for the purpose of quantifying H/D ratios in solution. A successful demonstration will provide an easily implemented, low cost, and non-invasive method for remote and unattended H/D ratio measurements with a resolution of less than 0.2% vol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗