Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Star magnitude and manual navigation sighting accuracy using the Apollo T2 sextant.

This laboratory study investigated the effect of four star magnitudes (0, +1, +2, +3) upon the angular sighting accuracy attainable between a star and a lunar limb using a space-rated sextant with an 8-power telescope. Four males were tested. The results indicated that over a series of daily sightings sighting accuracy increases as star magnitude decreases; i.e., the angle between the actual lunar limb and the perceived lunar limb decreases as the intensity of the star increases. The significant subject and day main effects that were found indicate that each individual must be calibrated against himself and that extreme care must be taken to center the various images correctly within the sextant's field of view each time the instrument is set up. These findings are discussed in relation to further refinement of a graphic model of the distribution of energy on the retina. A discussion is also presented on the differences between sextant sighting research conducted in the laboratory and in the real, high-altitude or space environment.

Haines, R. F.↗

The accuracy of geopotential solutions from resonant satellite data

Tracking data from a significant number of strongly resonant satellites have not yet been incorporated into recent comprehensive geopotential solutions. This data furnishes excellent comparative and absolute tests of these solutions for resonant coefficients of order (m) 2, 3, 4, 9 and 14. Tracking arcs of from 1 month to 6 years are examined on seven satellites of 1 rev/day, three of 2 revs/day, and one each of 9 and 14 revs/day. Current values for these fully normalized resonant coefficients as judged by this independent and sensitive data, range in accuracy from 2 x 10 to the minus 8th power to 5 x 10 to the minus 8th power. This represents an increase in accuracy by a factor from 3 to 5 over solutions current in the mid 1960's.

Wagner, C. A.↗

On the normality and accuracy of simulated random processes.

Efficient methods of simulating stationary and nonstationary random processes and envelopes, by using a series of sine or cosine functions or by using the fast Fourier transform, have been proposed previously. Without applying the central limit theorem, it is shown in this paper that the simulated random processes are asymptotically Gaussian processes as the number of terms, N, of sine or cosine functions approaches infinity. The accuracy of the first-order probability densities of the simulated random processes is investigated by using the fast Fourier transform. Numerical results are computed with respect to the variation of the number of terms, N, of sine or cosine functions used for simulation. It is shown that within the practical range of N, such as 500, the accuracy is remarkably satisfactory even outside the region of 3 standard deviations.

Yang, J.-N.↗

The limitations of wind measurement accuracy for balloon systems

The error in horizontal wind field measurements as computed from the trajectory of balloons with linear and quadratic rise rates (as functions of altitude) has been derived. Balloon trajectories through light, moderate, and severe wind fields have been considered. Figures are presented which show the wind error vs altitude for various rise rates in each wind field, assuming linear smoothing of the trajectory data. The rise rate profile of the Jimsphere is analyzed as a special case. The results and figures presented are useful in determining the ultimate capability of rising balloon systems in general and for the Jimsphere system in particular for measuring wind from the surface to 18 km. Using the figures presented, it is possible to estimate the wind accuracy that can be achieved by any type of rising balloon by knowing only its rise rate behavior vs altitude. In addition, the results can be used in balloon design to determine what rise rate function is needed to achieve specified wind accuracies. A table is presented which shows the balloon radius for smooth and roughened spheres needed to achieve 2 to 20 m/sec rise rates at 10 and 14 km altitudes.

Luers, J. K.↗

Rigid body mode pointing accuracy and stability criteria for an orbiting spacecraft

The effect of gravity gradient torque disturbances (which is an order of magnitude greater than the other torque disturbances and is sinusoidal with a frequency of two cycles per orbit) on pointing accuracy can be predicted very precisely. However, since the sensor noise such as star tracker and gyro inherent noise, is random, their effect can only be predicted statistically. The most common method used is computer simulation with appropriate sensor model and adjusting spacecraft control laws for minimum pointing error, as presented by Harris (1972). The general investigation outlined theoretically relates spacecraft controls to pointing accuracy in terms of the sensor noise power spectrum. The results are presented in graphical form.

Sandhu, G. S.↗

The accuracy of automatic tracking

It has been generally assumed that tracking accuracy changes similarly to the rate of change of the curve of the measurement conversion. The problem that internal noise increases along with the signals processed by the tracking device and that tracking accuracy thus drops were considered. The main prerequisite for solution is consideration of the dependences of the output signal of the tracking device sensor not only on the measured parameter but on the signal itself.

Kastrov, V. V.↗

Evaluating the accuracy of selenodesic reference grids

Estimates were made of the accuracy of reference point grids using the technique of calculating the errors from theoretical analysis. Factors taken into consideration were: telescope accuracy, number of photographs, and libration amplitude. To solve the problem, formulas were used for the relationship between the coordinates of lunar surface points and their images on the photograph.

Koptev, A. A.↗

Digital phase-locked-loop speed sensor for accuracy improvement in analog speed controls

A digital speed control that can be combined with a proportional analog controller is described. The stability and transient response of the analog controller were retained and combined with the long-term accuracy of a crystal-controlled integral controller. A relatively simple circuit was developed by using phase-locked-loop techniques and total error storage. The integral digital controller will maintain speed control accuracy equal to that of the crystal reference oscillator.

Birchenough, A. G.↗

Estimation of the accuracy with which the position of the center of mass of an Interkosmos series artificial earth satellite is calculated

The effects of disturbing forces on position calculation, and errors in the initial conditions of motion and in the selected assignment calculation schemes are estimated. It is shown that the main disturbing effects on the accuracy are due to density variations of the upper atmosphere. Recommendations are presented for estimating the calculation accuracy along with an example of such an estimate for the Interkosmos-7 artificial earth satellite. Other factors considered include the adopted scheme and computational algorithms used, effects of disturbing forces not taken into account earlier, and errors in the values of constants and in models of disturbing forces.

Elyasberg, P. Y.↗

Accuracy of site coordinates obtainable by a mobile lunar laser station

The accuracy with which a mobile lunar laser station can be located was the subject of a modeling study. The influence of the number and accuracy of fixed lunar ranging stations, the uncertainty in polar motion, and data loss due to weather and similar factors were considered, and the results are given in a cartographic form. In general, all three coordinates (for coordinates to latitude + or - 60 deg) were determined to better than the pole uncertainty, given three or more fixed sites and reasonable weather. This result indicates that one or more mobile stations would be suitable for the study of geotectonics.

Loumos, G. L.↗

The influence of the computational mesh on accuracy for initial value problems with discontinuous or nonunique solutions

Discontinuous, or weak, solutions of the wave equation, the inviscid form of Burgers equation, and the time-dependent, two-dimensional Euler equations are studied. A numerical method of second-order accuracy in two forms, differential and integral, is used to calculate the weak solutions of these equations for several initial value problems, including supersonic flow past a wedge, a double symmetric wedge, and a sphere. The effect of the computational mesh on the accuracy of computed weak solutions including shock waves and expansion phenomena is studied. Modifications to the finite-difference method are presented which aid in obtaining desired solutions for initial value problems in which the solutions are nonunique.

Maccormack, R. W.↗

The Shuttle Orbital Maneuvering System P-V-T Propellant Quantity Gaging Accuracy and Leak Detection Allowance for Four Instrumentation Conditions

The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.

Duhon, D. D.↗

An analysis of the accuracy and cost-effectiveness of a cropland inventory utilizing remote sensing techniques

Cropland inventories utilizing high altitude and Landsat imagery were conducted in Kern County, California. It was found that in terms of the overall mean relative and absolute inventory accuracies, a Landsat multidate analysis yielded the most optimum results, i.e., 98% accuracy. The 1:125,000 CIR high altitude inventory is a serious alternative which can be very accurate (97% or more) if imagery is available for a specific study area. The operational remote sensing cropland inventories documented in this study are considered cost-effective. When compared to conventional survey costs of $62-66 per 10,000 acres, the Landsat and high-altitude inventories required only 3-5% of this amount, i.e., $1.97-2.98.

Jensen, J. R.↗

A demonstration of a transportable radio interferometric surveying system with 3-cm accuracy on a 307-m base line

A precision geodetic measurement system (Aries, for Astronomical Radio Interferometric Earth Surveying) based on the technique of very long base line interferometry has been designed and implemented through the use of a 9-m transportable antenna and the NASA 64-m antenna of the Deep Space Communications Complex at Goldstone, California. A series of experiments designed to demonstrate the inherent accuracy of a transportable interferometer was performed on a 307-m base line during the period from December 1973 to June 1974. This short base line was chosen in order to obtain a comparison with a conventional survey with a few-centimeter accuracy and to minimize Aries errors due to transmission media effects, source locations, and earth orientation parameters. The base-line vector derived from a weighted average of the measurements, representing approximately 24 h of data, possessed a formal uncertainty of about 3 cm in all components. This average interferometry base-line vector was in good agreement with the conventional survey vector within the statistical range allowed by the combined uncertainties (3-4 cm) of the two techniques.

Ong, K. M.↗

Navigation accuracy analysis for the Mariner-Jupiter-Saturn 1977 mission

The results of the latest navigation capability study for the Mariner-Jupiter-Saturn 1977 mission are presented and analyzed. Predicted planet-relative and satellite-relative accuracies are given for radio only and radio plus optical approach navigation on three representative trajectories. In addition, planet-relative accuracies are given for cruise navigation on one of the trajectories. The dynamical and measurement error models used in the study are discussed, and the basic MJS77 navigation strategy is described. The navigation capability is evaluated in the light of the mission's objectives; and the variation in capability among the three trajectories is examined with regard to the effects of the major error sources and the trajectory dependent encounter geometries.

Jacobson, R. A.↗

Forest Classification Accuracy as Influenced by Multispectral Scanner Spatial Resolution

The author has identified the following significant results. A supervised classification within two separate ground areas of the Sam Houston National Forest was carried out for two sq meters spatial resolution MSS data. Data were progressively coarsened to simulate five additional cases of spatial resolution ranging up to 64 sq meters. Similar processing and analysis of all spatial resolutions enabled evaluations of the effect of spatial resolution on classification accuracy for various levels of detail and the effects on area proportion estimation for very general forest features. For very coarse resolutions, a subset of spectral channels which simulated the proposed thematic mapper channels was used to study classification accuracy.

Nalepka, R. F.↗

Evaluation of Landsat image registration accuracy

The Large Area Crop Inventory Experiment (LACIE) is an attempt to demonstrate the capability to forecast the annual production of major crops such as wheat and corn. Good image registration of data acquired on different dates is one of the key assumptions made in LACIE. This paper describes an algorithm to measure the accuracy of the current registration procedure. This algorithm employs a modified version of sequential similarity detection algorithm (SSDA). Based on over 264 registration checks, it was found that the root-mean-square of registration errors was 1.0 pixel. The failure rate of our registration checking algorithm was less than 10 per cent and the standard deviation of the accuracy of this algorithm was less than 0.2 picture element.

Kaneko, T.↗

A high accuracy all-angle gyroscope readout using quantized flux

Means are described to use SQUID magnetometer flux counting and the London moment of a spherical superconducting gyroscope to read out the gyroscope spin axis direction to an accuracy of at least 23 bits per quadrant. The system is discussed in analogy to optical fringe counting as applied to distance measurement. Several methods of applying both analog and digital SQUID magnetometers to the readout problem are given, as well as limitations on each. Described are two methods of increasing the flux available for measurement: magnetizing the gyroscope with a trapped field, and optimizing readout circuit inductances. Finally, the same principle on which the gyroscope readout is based is applied to a description of a high accuracy, flux counting, digital angle encoder.

Anderson, J. T.↗