Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Percutaneous Laser Ablation of Liver Metastases from Neuroendocrine Neoplasm. A Retrospective Study for Safety and Effectiveness

Purpose: To retrospectively assess safety and efficacy of laser ablation (LA) of multiple liver metastases (LM) from neuroendocrine neoplasms (NEN). Methods: Twenty-one patients with NEN and at least 3 LM ≤ 4 cm in diameter underwent ultrasonography-guided LA. Up to seven LM were ablated in a single session; if the number of LM exceeded seven, the remaining LM were ablated in further LA sessions with a time interval of 3–4 weeks. LA was performed according to the multifiber technique. The patients underwent contrast-enhanced CT 1 month after LA, and were subsequently monitored every 3 months for the first 2 years and then every 6 months. Results: In total, 189 LM were treated in 21 patients (mean 9 ± 8.2, median 6) in 41 LA sessions (range 1–5). The diameter of LM ranged from 5 to 35 mm (median 19 mm, mean 17.9 ± 6.4 mm). One grade 4 complication occurred (0.53%): a bowel perforation managed by surgery. Technical efficacy was 100%, primary efficacy rate 94.7%, and secondary efficacy rate 100%. Complete relief of hormone-related symptoms was obtained in all the 13 symptomatic patients. Median follow-up was 39 months (range 12–99). 1-, 2-, 3-, and 5-year survival rates were 95%, 86%, 66%, and 40%, respectively. Overall survival resulted higher for patients with Ki-67 expression ≤ 7% than for those with Ki-67 > 7% (p = 0.0347). Conclusions: LA is a promising and safe technique to treat LM from NEN. A longer follow-up should provide definitive information on the long-term efficacy of this liver-directed therapy. Level of Evidence: Retrospective study, local non-random sample, level 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Au, Ge and AuGe Nanoparticles Fabricated by Laser Ablation

A eutectic AuGe target immersed in distilled water was ablated by pulsed ultraviolet laser light. The structure of the ablated material was investigated by high-resolution transmission electron microscopy (HRTEM). The images show formation of nanowire structures of AuGe up to 100 nm in length, with widths of 5-10 nm. These nanostructures have Ge content significantly lower than the target material. Electron diffraction demonstrates that they crystallize in the {alpha}-AuGe structure. For comparison, laser ablation of pure Au and pure Ge targets was also performed under the same conditions. HRTEM shows that Ge forms spherical nanoparticles with a characteristic size of {approx}30 nm. Au forms spherical nanoparticles with diameters of {approx}10 nm. Similar to AuGe, it also forms chainlike structures with substantially lower aspect ratio.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of the Solvent on the Structure and Morphology of Nanoparticles Fabricated by Laser Ablation of Bulk Magnesium Targets

Ultrafine powders and colloid solutions of nanoparticles are fabricated by nanosecond pulsed laser ablation (a Nd:YAG laser, 1064 nm, 7 ns, 150 mJ, and 20 Hz) of metallic magnesium targets in water and organic solvents of different polarities (ethyl alcohol, ethyl acetate, and n-hexane). The morphology, dimensional characteristics, composition, and structure of the particles are studied by the methods of transmission electron microscopy, x-ray diffraction, and Fourier-transform infrared spectroscopy depending on the solvent used. For the first time it has been demonstrated that nanostructures of magnesium oxyhydroxide Mg{sub 5}O(OH){sub 8} are formed during the ablation in water. It is established that in organic solvents, formation of hexagonal and cubic magnesium oxides is possible. Nanoparticles fabricated by the ablation in less thermostable solvents – ethyl acetate and hexane – contain carbonates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Mass Spectra of Individual Organic Particles Generated by UV Laser Ablation and in the IR/UV Two-Step Mode

One of the most fundamental aspects of single particle mass spectrometry is that the individual particle mass spectra are first classified and only then averaged. When ions are generated by ablation with a UV laser the mass spectra of particles with identical compositions exhibit large particle to particle fluctuations in the mass spectral intensity pattern. This is particularly true when it comes to particles containing organic molecules. At laser fluence that is sufficient to ionize sulfates many of the organic molecules exhibit high degree of fragmentation, often to the point where they cannot be distinguished from elemental carbon. In contrast, when ion generation is separated into two steps, in which the first step uses infra red to evaporate the semi-volatile components and the second, time delayed UV pulse to ionize the evaporating plume, the quality of the individual particle mass spectra are significantly improved. We present an experimental investigation of the properties and behavior of individual particle mass spectra of organic particles that are generated by ablation and in two steps. We investigate the effect of UV laser fluence and the delay between the two lasers. The study shows that the two step approach yields highly reproducible mass spectra that contain sufficient detail to allow clear molecular assignments. The two step approach also produces 10 times as many ions, and the mass spectral intensity can be related to the amount of organics in the particle. In contrast, ablation generated mass spectra were found to exhibit high degree of fragmentation and particle-to-particle fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser hydrothermal reductive ablation of titanium monoxide: Hydrated TiO particles with modified Ti/O surface

IR laser- and UV laser-induced ablation of titanium monoxide (TM) in hydrogen (50 Torr) is compared to the same process induced in vacuum and shown to result in deposition of hydrated surface modified nanostructured titanium suboxide films. Complementary analyses of the films deposited in vacuum and in hydrogen by Fourier transform infrared, Raman and X-ray photoelectron spectroscopy, X-ray diffraction and electron microscopy allowed to determine different features of both films and propose a mechanism of surface modification of ejected particles, which involves hydrothermal reduction of TM and subsequent reactions of evolved water. The films exert good adhesion to metal and quartz surfaces and are hydrophobic in spite of having their surface coated with adsorbed water. - Graphical abstract: Laser ablation of titanium monoxide (TiO) in hydrogen involves a sequence of H{sub 2} and H{sub 2}O eliminations and additions and yields hydrated amorphous nanostructured titanium suboxide which is richer in oxygen than TiO. Highlights: Black-Right-Pointing-Pointer IR and UV laser ablated particles of titanium monoxide (TiO) undergo amorphization. Black-Right-Pointing-Pointer Films deposited in vacuum have TiO stoichiometry and are oxidized in atmosphere. Black-Right-Pointing-Pointer Films deposited in hydrogen are hydrated and have more O in topmost layers. Black-Right-Pointing-Pointer Films modification in hydrogen is explained by reactions in hydrogen plasma.

36 MATERIALS SCIENCE↗

The TriBeam system: Femtosecond laser ablation in situ SEM

Femtosecond laser ablation offers the unique ability to remove material at rates that are orders of magnitude faster than existing ion beam technologies with little or no associated damage. By combining ultrafast lasers with state-of-the-art electron microscopy equipment, we have developed a TriBeam system capable of targeted, in-situ tomography providing chemical, structural, and topographical information in three dimensions of near mm{sup 3} sized volumes. The origins, development, physics, current uses, and future potential for the TriBeam system are described in this tutorial review. - Graphical abstract: Display Omitted - Highlights: • An emerging tool, the TriBeam, for in situ femtosecond (fs) laser ablation is presented. • Fs laser ablation aided tomography at the mm{sup 3}-scale is demonstrated. • Fs laser induced deposition of Pt is demonstrated at sub-diffraction limit resolution. • Fs laser surface structuring is reviewed as well as micromachining applications.

36 MATERIALS SCIENCE↗

Laser ablation of sub-10 nm silver nanoparticles

Laser ablation of silver nanoparticles (NPs) was studied with laser post-ionization (LPI) time-of-flight mass spectrometry (TOF MS). Silver NPs containing ~15 000 Ag atoms (4 nm radius) were deposited by soft landing (energy 3 eV/atom) onto indium tin oxide (ITO)/glass substrates. Laser ablation was performed using frequency-doubled Ti:sapphire nanosecond pulsed laser irradiation at three different wavelengths (371, 401, and 421 nm), whereas for post-ionization, pulses from an F 2 laser were used. Laser fluences and time delay dependencies of Ag and In signals were obtained. Using these data, the temperature of the desorption source as well as its time duration were calculated. It was found that the peak temperature of NPs was above their melting point and they cooled down slowly, with temperature decay time of several hundreds of nanoseconds. This anomalous behavior was explained based on a model where the semiconducting ITO substrate is initially transparent to the desorption laser radiation but starts to adsorb it due to the temperature increase arising from heat exchange with NPs. Poor heat conduction in the ITO film creates conditions for long-lived hot spots on the surface and initiates further optical damage of the substrate. No difference in the ablation process due to plasmon resonance was detected, likely due to thermal expansion and melting of NPs during laser irradiation, which then broadens the plasmon absorption band enough to cover all wavelengths used. Here, these results clearly demonstrate that the process of NP interaction with laser radiation is governed not only by initial optical and thermophysical parameters of NPs and the surrounding media, but also by their alteration due to temperature increases during the irradiation process.

36 MATERIALS SCIENCE↗

Dynamics of Molecular Emission Features from Nanosecond, Femtosecond Laser and Filament Ablation Plasmas

The evolutionary paths of molecular species and nanoparticles in laser ablation plumes are not well understood due to the complexity of numerous physical processes that occur simultaneously in a transient laser-plasma system. It is well known that the emission features of ions, atoms, molecules and nanoparticles in a laser ablation plume strongly depend on the laser irradiation conditions. In this letter we report the temporal emission features of AlO molecules in plasmas generated using a nanosecond laser, a femtosecond laser and filaments generated from a femtosecond laser. Our results show that, at a fixed laser energy, the persistence of AlO is found to be highest and lowest in ns and filament laser plasmas respectively while molecular species are formed at early times for both ultrashort pulse (fs and filament) generated plasmas. Analysis of the AlO emission band features show that the vibrational temperature of AlO decays rapidly in filament assisted laser ablation plumes.

Laser ablation (LA)↗

Ablation and plasma emission produced by dual femtosecond laser pulses

Pairs of 80 fs, 800 nm laser pulses were used to ablate Si, Cu, and CaF{sub 2} in air. The spectrally resolved plasma emission was measured as a function of laser fluence and pulse delay. After an initial dip, the fluorescence was found to increase monotonically with pulse delay, reaching a plateau after some tens of picoseconds, depending on the material and fluence. The enhancement ratio (defined as the ratio of the fluorescence produced by the pulse pair to that produced by a single pulse of the same total fluence) reaches a maximum value of 6 and 11 at a fluence of {approx}6 J/cm{sup 2} for Si and Cu, respectively, and declines to a value below 2 at higher fluences. In contrast, the enhancement for CaF{sub 2} increases slowly from zero near threshold to a broad maximum value of 2 near 50 J/cm{sup 2}. Using reflectivity and atomic force microscopy measurements as diagnostics, we interpret the Si and Cu behavior in terms of a two phase mechanism, in which the first pulse melts the surface of the crystal and the second pulse ablates the resulting liquid film. A qualitatively different mechanism initiated by multiphoton absorption is involved in CaF{sub 2} ablation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ablation dominated implosion dynamics of aluminum and stainless steel nested cylindrical wire arrays

The results of experiments with combined aluminum (Al) and stainless steel (SS) alloy 304, nested wire arrays from the 1 MA COBRA generator at Cornell University are presented. The loads studied consisted of a 6 mm diameter inner array and a 13 mm diameter outer array with a different material in each array: SS or aluminum. Al implodes before SS in all loads studied, even when Al was on the inner array. The new wire ablation dynamic model and spectroscopic modeling are used to interpret these data. The observed implosion dynamics are likely a result of the higher ablation rate of Al. These initial results suggest that combining wire materials with different ablation rates in wire array loads could be developed into a useful technique for x-ray pulse shaping and radiation yield optimization.

36 MATERIALS SCIENCE↗

Langmuir probe characterization of laser ablation plasmas

For laser ablation plumes that are significantly ionized, Langmuir probes have proved to be a useful tool for measuring the plume shape, ion energy distribution, and electron temperature. Typically in laser ablation plasmas the flow velocity is supersonic, which complicates the interpretation of the current-voltage probe characteristic. In this paper we describe some recent developments on the application of Langmuir probes for laser ablation plume diagnosis. We have investigated the behavior of the probe when it is orientated perpendicular, and parallel, to the plasma flow, and show how an analytical model developed for plasma immersion ion implantation, can quantitatively describe the variation of the ion current with probe bias for the case when the plasma flow is along the probe surface. The ion signal recorded by a probe in the parallel position is proportional to the ion density and the square root of the bias voltage. It is shown that the current varies as m{sub i}{sup -1/2} so that by comparing the ion signals from the parallel and perpendicular positions it is possible to estimate the mass of the ions detected. We have also determined the temporal variation of electron temperature. A planar probe oriented parallel to the plasma flow, where the ion current due to the plasma flow is eliminated, gives a more reliable measurement of T{sub e} (<0.6 eV). The measured T{sub e} is consistent with the measured ion current, which is dependent on T{sub e} when the time taken for an element of plasma to traverse the probe is longer than the time taken for the matrix ion sheath extraction phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultraviolet laser ablation of polycarbonate and glass in air

The fundamental physical processes that follow ultraviolet laser ablation of polycarbonate and borosilicate glass in air have been investigated using photodeflection as a function of the distance from the surface to probe laser. Four features were observed in the data sets for each material. Two of these features correlate well with gas dynamical predictions for the expansion of the shock wave and gas plume. The third feature is consistent with the propagation of the popping sound of the laser ablation event. The final feature, which occurs at very early times and does not shift significantly in time as the surface to probe distance is increased from 0 to greater than 6 mm, has been tentatively ascribed to the ejection of fast electrons. The final significant observation is complete blocking of the probe laser, only observed during borosilicate ablation, which is attributed to scattering of the probe laser light by macroscopic SiO{sub x} particles that grow in the final stages of plume expansion and cooling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative Analysis of Plasma Ablation Using Inverse Wire Array Z-pinches

An inverse (exploding) wire array configuration, in which the wires form a cylinder around a current carrying electrode on axis, was used to study the ablation phase of the pinch. This configuration allows the parameters of the plasma from individual wires of the array to be measured as the ablated plasma streams propagate in the outward radial direction. The density distribution and the evolution of the natural mode of modulation of the ablation was measured with interferometry and soft x-ray imaging. Measurements of the voltage across the array, which in this configuration is determined by the private magnetic flux around the individual wires, allows information on the localisation of the current to be obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanisms of the laser plume expansion during the ablation of LiMn{sub 2}O{sub 4}

Films of LiMn{sub 2}O{sub 4} prepared by pulsed laser ablation deposition are typically lithium deficient when grown at background pressures ranging between 10{sup -4} and 20 Pa. The deficiency of light atomic species such as lithium in LiMn{sub 2}O{sub 4} thin films occurs as a result of the different behavior of the species during plume expansion and the deposition of the film at elevated deposition temperatures. The plasma plume evolution in vacuum and 20 Pa oxygen pressure are studied using two spectroscopic techniques: emission spectroscopy and plume imaging. Higher velocities and a wider spatial distribution of lithium atoms are observed in vacuum when compared with manganese and oxygen species. Plume species are slowed down due to collisions with gas molecules when ablating LiMn{sub 2}O{sub 4} in an oxygen atmosphere. As a result, a strong deceleration of the plasma front occurs, and the effect is more pronounced for the light species, e.g., Li. Comparing the spatial manganese and lithium distribution within the plasma, the lithium species are again scattered into a wider angular range. These similar spatial distributions of Li atoms detected in the pressure range between 10{sup -4} and 20 Pa suggest that it is not possible to achieve a congruent lithium transfer to a growing film if the target contains heavier elements besides lithium. The general implications for the ablation of materials containing a combination of light and heavy elements are that as-grown films are inherently deficient with respect to the content of the light elements. If the mass ratio between the light and the heavy elements is not too different, is should be possible to find a set of deposition parameters which will result in the growth of a film with the desired composition.

36 MATERIALS SCIENCE↗

Theoretical Modeling of Femtosecond Pulsed Laser Ablation of Silicon

Femtosecond (fs) laser ablation yield of semiconductors critically depends on pulse shape in time and space domain, laser wavelength and fluence. We have carried out a theoretical study of fs-pulsed laser interaction with silicon to optimize the ablation process using two-temperature model for laser pulse ({lambda} = 800 nm), which is rectangular in time domain pulse (width = 100 fs) and uniform intensity in circular cross-section of 100 {mu}m diameter. We have calculated ablation threshold, depth of material removal per pulse and refractive index change of silicon after irradiated by laser pulse and compared with the available experimental results. The formation of fs-laser induced periodic sub-wavelength surface grating structures on the silicon is also discussed within the frame work of carrier induced nonlinear effect.

36 MATERIALS SCIENCE↗

Evolution and imaging of nanoparticles observed in laser ablated carbon plume

We report evidence of nanoparticles formation in laser ablated carbon plasma created by irradiating a graphite target with nanosecond neodymium doped yttrium aluminum garnet laser. The temporal evolution and spatial distribution of C{sub 2} molecules in the plasma is studied using optical emission spectroscopy, dynamic imaging and laser induced fluorescence techniques. The laser induced fluorescence spectrum and imaging of C{sub 2} fluorescence corresponding to transition d {sup 3}PI{sub g}-a {sup 3}PI{sub u} (0, 1) (lambda=563.5 nm) is investigated by probing the expanding plume using a dye laser. The temporal evolution of ground state number density of C{sub 2} shows density varying from 2.6x10{sup 20}/m{sup 3} to 1.2x10{sup 22}/m{sup 3} on varying delay between the ablating and probe pulse from 200 to 600 ns. A peculiar bifurcation of carbon plume into two parts at approx270 ns after the formation of plasma is attributed to recombination of carbon species and formation of nanoparticles. This study may help in quantitatively understanding of formation of carbon molecular species and the nanoparticles produced in laser ablated carbon plume.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗