Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Similarity-transformed equation-of-motion vibrational coupled-cluster theory

A similarity-transformed equation-of-motion vibrational coupled-cluster (STEOM-XVCC) method is introduced as a one-mode theory with an effective vibrational Hamiltonian, which is similarity transformed twice so that its lower-order operators are dressed with higher-order anharmonic effects. The first transformation uses an exponential excitation operator, defining the equation-of-motion vibrational coupled-cluster (EOM-XVCC) method, and the second uses an exponential excitation-deexcitation operator. From diagonalization of this doubly similarity-transformed Hamiltonian in the small one-mode excitation space, the method simultaneously computes accurate anharmonic vibrational frequencies of all fundamentals, which have unique significance in vibrational analyses. We establish a diagrammatic method of deriving the working equations of STEOM-XVCC and prove their connectedness and thus size-consistency as well as the exact equality of its frequencies with the corresponding roots of EOM-XVCC. We furthermore elucidate the similarities and differences between electronic and vibrational STEOM methods and between STEOM-XVCC and vibrational many-body Green’s function theory based on the Dyson equation, which is also an anharmonic one-mode theory. The latter comparison inspires three approximate STEOM-XVCC methods utilizing the common approximations made in the Dyson equation: the diagonal approximation, a perturbative expansion of the Dyson self-energy, and the frequency-independent approximation. The STEOM-XVCC method including up to the simultaneous four-mode excitation operator in a quartic force field and its three approximate variants are formulated and implemented in computer codes with the aid of computer algebra, and they are applied to small test cases with varied degrees of anharmonicit

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implausibility of the vibrational theory of olfaction

The vibrational theory of olfaction assumes that electron transfer occurs across odorants at the active sites of odorant receptors (ORs), serving as a sensitive measure of odorant vibrational frequencies, ultimately leading to olfactory perception. A previous study reported that human subjects differentiated hydrogen/deuterium isotopomers (isomers with isotopic atoms) of the musk compound cyclopentadecanone as evidence supporting the theory. Here, we find no evidence for such differentiation at the molecular level. In fact, we find that the human musk-recognizing receptor, OR5AN1, identified using a heterologous OR expression system and robustly responding to cyclopentadecanone and muscone, fails to distinguish isotopomers of these compounds in vitro. Furthermore, the mouse (methylthio)methanethiol (MTMT)-recognizing receptor, MOR244-3, and other selected human and mouse ORs, responded similarly to normal, deuterated, and ¹³C isotopomers of their respective ligands, paralleling our results with the musk receptor OR5AN1. These findings suggest that the proposed vibration theory does not apply to the human musk receptor OR5AN1, mouse thiol receptor MOR244-3, or other ORs examined. Also, contrary to the vibration theory predictions, muscone-d₃₀ lacks the 1,380-1,550 cm⁻¹ IR bands claimed to be essential for musk odor. Furthermore, our theoretical analysis shows that the proposed electron transfer mechanism of the vibrational frequencies of odorants could be easily suppressed by quantum effects of non-odorant molecular vibrational modes. As a result, these and other concerns about electron transfer at ORs, together with our extensive experimental data, argue against the plausibility of the vibration theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-threshold vibrational excitation of acetylene by positron impact

We report vibrational excitation cross sections for C-C and C-H symmetric stretch modes of acetylene by positron impact. The contribution of these infrared inactive modes to the annihilation parameter is also addressed. The Feshbach projection operator approach was employed to vibrationally resolve e{sup +}-acetylene scattering phase shifts obtained with the Schwinger multichannel method. The present results point out a virtual state pole at the equilibrium geometry of acetylene that becomes a bound state as either bond is stretched, in qualitative agreement with previous calculations for small hydrocarbons. The vibrational couplings are stronger for the C-C mode, giving rise to a bound state pole within the Franck-Condon region of the vibrational ground state. These bound and virtual states give rise to sharp threshold structures (vibrational resonances) in both the vibrational excitation cross sections and the annihilation parameter (Z{sub eff}). We found fair agreement between the present calculations and previously reported e{sup +}-acetylene vibrational excitation cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determining Eigenfrequencies and Homogeneous Widths of Lines of Intermolecular Vibrations in Water and in Aqueous Solutions of Hydrogen Peroxide Using Raman Spectroscopy

We have examined low-frequency Raman spectra of intermolecular vibrations of weak aqueous solutions of hydrogen peroxide and water. The differences between the observed Raman frequencies and the data from the literature on the IR-absorption frequencies of the same vibrations, as well as the interrelations between the frequencies and the widths of Lorentzian contours that approximate the vibrational spectra of the dynamic susceptibility, have been discussed. Based on a model of free damped vibrations of a classical oscillator with an inhomogeneous broadening, we have explained these effects for the first time. The homogeneous line widths and the damping times of the observed intermolecular vibrations have been determined. The eigenfrequencies of these vibrations have been calculated, and they have been shown to agree well with the data from the literature on the frequencies of IR absorption of water. We have shown that these parameters of intermolecular vibrations for water and for aqueous solutions of hydrogen peroxide differ from each other.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-beam hybrid fs/ps coherent anti-Stokes Raman scattering of rotation–vibration non-equilibrium

In this work, we demonstrate time-resolved rotational and vibrational temperature measurements to probe plasma non-equilibrium through a simple three-beam hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) system. A single pump/Stokes pair is employed to generate both the pure-rotational and ro-vibrational Raman coherence. A novel phase-matching scheme, to our knowledge, is employed to spatially overlap the two CARS signals, simplifying the optical design and allowing signal selection by tuning a single spectrometer grating. Measurements were performed near the electrodes in a N 2 DC glow discharge. Both the rotational temperature and the vibrational populations up to $v$ = 8 were calculated from the separately measured single-shot pure-rotational and ro-vibrational CARS spectra. Strong rotation–vibration non-equilibrium was observed at both electrodes, with the cathode showing higher vibrational and rotational temperatures. In addition, non-Boltzmann behaviors were observed at both electrodes. This simplified approach enables measurements of rotational and vibrational temperatures with high spatial resolution in non-equilibrium flows.

42 ENGINEERING↗

A Survey of Floor Vibration Noise at All Sectors in the APS Experiment Hall

A vibration survey of the APS experiment hall floor was conducted. It was found that beamlines 10-20 have particularly low levels of vibration when compared to the rest of the facility. The vibration spectrum for each beamline floor can be found in the appendix. Throughout the majority of the 5-100 Hz vibration spectrum beamlines at the APS fall below the most stringent NEST vibration criteria. Lastly, it was concluded that the magnitude of vibrations at a particular beamline is largely dependent upon the magnitude of vibrations present at the nearby mezzanine support column.

43 PARTICLE ACCELERATORS↗

SuperCam Body Unit Flight Model Vibration Test Report (Rev.A)

This report describes the vibration tests that were applied to the SuperCam Body Unit (SCBU) Flight Model (FM) at Protoflight levels. These tests were performed November 28 and 29, 2018, at the Los Alamos National Laboratory ISR-5 Shock and Vibration Environmental Test Facility, at TA-3, Building 502 Room E102. The test environments shown below were obtained from the SuperCam FM test plan, which is the overarching document for all testing. The vibration results from all testing are shown below. An anomaly was identified during the FM functional testing at the conclusion of the X-Axis. It was decided to re-test at -6 dB to determine if the anomaly progressed or remained the same. Functional testing did not show any changes after the -6 dB random vibration. It was then decided to re-test at -3 dB. Once again functional testing after the -3 dB vibration did not show any changes. Low-level random vibration signature surveys were performed before and after the -6 dB and -3 dB retests. This test series met the vibration requirements to qualify the SuperCam Body Unit FM for flight without any significant anomalies.

42 ENGINEERING↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Vibrational population distributions in nonequilibrium nozzle expansion flows

Experimental measurements and theoretical calculations of the vibrational population distribution in nonequilibrium nozzle expansion flows of gas mixtures are reported. These studies were directed toward determining whether vibrational energy exchange pumping could lead to laser action on the vibrational bands of a diatomic molecule. Three different types of experiments were conducted. These showed (1) that vibrational energy was preferentially transferred from N2 to CO in supersonic nozzle flows containing these gases; (2) that under some conditions this vibrational energy exchange pumping mechanism created population inversions in the vibrational levels of CO; and (3) that at large expansion ratios the magnitude of these population inversions was sufficient to sustain lasing in the nozzle. A theoretical model was developed to calculate vibrational state population distributions in gas dynamic expansions of a mixture of diatomic gases. Although only isothermal calculations have been completed, these data indicate that population inversions are predicted for conditions similar to those obtained in the nozzle expansion flows.

Watt, W. S.↗

Vibrational sensitivity of a measuring instrument and methods of increasing the accuracy of its determinations

The properties and peculiarities of two groups of measuring systems reacting to vibrations are discussed. Specifically, results of the action of a three dimensional, cophasal, monoharmonic vibration on the linear system of a measuring instrument was analyzed. Data are also given on the connection between vibration sensitivity and vibration resistance for instruments, methods for estimating vibration resistance, and formulas for expressing test results of vibration resistance. Experimental data are also given for decreasing errors in nonlinear systems during vibrations.

Mironov, Y. S.↗

Vibration ride comfort criteria

Results are presented for an experimental study directed to derive equal vibration discomfort curves, to determine the influence of vibration masking in order to account for the total discomfort of any random vibration, and to develop a scale of total vibration discomfort in the case of human response to whole-body vertical vibration. Discomfort is referred to as a subjective discomfort associated with the acceleration level of a particular frequency band. It is shown that passenger discomfort to whole-body vibration increases linearly with acceleration level for each frequency. Empirical data provide a mechanism for determining the degree of masking (or summation) of the discomfort of multiple frequency vibration. A scale for the prediction of passenger discomfort is developed.

Dempsey, T. K.↗

Concorde noise-induced building vibrations John F. Kennedy International Airport

The outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at six home sites along with the associated vibration levels in the walls, windows, and floors of these test homes. Limited subjective tests conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise showed that both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Preliminary results indicate that the relationship between window vibration and aircraft noise is: (1) linear, with vibration levels being accurately predicted from OASPL levels measured near the window; (2) consistent from flyover to flyover for a given aircraft type under approach conditions; (3) no different for Concorde than for other conventional jet transports (in the case of window vibrations induced under approach power conditions); and (4) relatively high levels of window vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde source characteristics.

Mayes, W. H.↗

Effect of vibration duration on human discomfort

The duration effects of random vertical vibration on passenger discomfort were studied in a simulated section of an aircraft cabin configured to seat six persons in tourist-class style. Variables of the study included time of exposure (0.25 min to 60 min) and the rms amplitude of vibration (0.025g to 0.100g). The vibrations had a white noise spectrum with a bandwidth of 10 Hz centered at 5 Hz. Data indicate that the discomfort threshold occurred at an rms vertical acceleration level of 0.027g for all durations of vibration. However, for acceleration levels that exceeded the discomfort threshold, a systematic decrease in discomfort occurred as a function of increasing duration of vibration. For the range of accelerations used, the magnitude of the discomfort decrement was shown to be independent of acceleration level. The results suggest that discomfort from vertical vibration applied in the frequency range at which humans are most sensitive decreases with longer exposure, which is the opposite of the recommendation of the International Standard ISO 2631-1974 (E) Guide for the Evaluation of Human Exposure to Whole-Body Vibration.

Clevenson, S. A.↗

Vibration and local instability of thermally stressed plates

The vibration and buckling of a double wedge square cantilever plate has been investigated. It is shown that the free vibration modes, which occur at Delta T ref = 0, transition into the buckled modes which occur at Delta T ref = Delta T ref-cr for the respective mode. Delta T ref-cr for a particular mode is defined as the magnitude of thermal load at which the frequency of the particular mode vanishes. The analysis yields the same number of buckling eigenvalues and buckling modes as there are vibration eigenvalues and vibration modes. Gradual application of the load in the analysis permits the change in each vibration frequency of interest and its associated mode to be followed up to the load at which the frequency of the mode becomes zero. This constitutes the limit of linear theory. As the load is increased, the thin edges of the plate begin to deform during vibration. This local deformation, which begins in the vibration mode, is shown to transition into the phenomena of local edge buckling at Delta T ref-cr for the mode.

Bailey, C. D.↗

Vibration control of rotor shaft

Suppression of flexural forced vibration or the self-excited vibration of a rotating shaft system not by passive elements but by active elements is described. The distinctive feature of this method is not to dissipate the vibration energy but to provide the force cancelling the vibration displacement and the vibration velocity through the bearing housing in rotation. Therefore the bearings of this kind are appropriately named Active Control Bearings. A simple rotor system having one disk at the center of the span on flexible supports is investigated in this paper. The actuators of the electrodynamic transducer are inserted in the sections of the bearing housing. First, applying the optimal regulator of optimal control theory, the flexural vibration control of the rotating shaft and the vibration control of support systems are performed by the optimal state feedback system using these actuators. Next, the quasi-modal control based on a modal analysis is applied to this rotor system. This quasi-modal control system is constructed by means of optimal velocity feedback loops. The differences between optimal control and quasi-modal control are discussed and their merits and demerits are made clear. Finally, the experiments are described concerning only the optimal regulator method.

Nonami, K.↗

Coupled rotor/fuselage dynamic analysis of the AH-1G helicopter and correlation with flight vibrations data

Under a research program designated Design Analysis Methods for VIBrationS (DAMVIBS), existing analytical methods are used for calculating coupled rotor-fuselage vibrations of the AH-1G helicopter for correlation with flight test data from an AH-1G Operational Load Survey (OLS) test program. The analytical representation of the fuselage structure is based on a NASTRAN finite element model (FEM), which has been developed, extensively documented, and correlated with ground vibration test. One procedure that was used for predicting coupled rotor-fuselage vibrations using the advanced Rotorcraft Flight Simulation Program C81 and NASTRAN is summarized. Detailed descriptions of the analytical formulation of rotor dynamics equations, fuselage dynamic equations, coupling between the rotor and fuselage, and solutions to the total system of equations in C81 are included. Analytical predictions of hub shears for main rotor harmonics 2p, 4p, and 6p generated by C81 are used in conjunction with 2p OLS measured control loads and a 2p lateral tail rotor gearbox force, representing downwash impingement on the vertical fin, to excite the NASTRAN model. NASTRAN is then used to correlate with measured OLS flight test vibrations. Blade load comparisons predicted by C81 showed good agreement. In general, the fuselage vibration correlations show good agreement between anslysis and test in vibration response through 15 to 20 Hz.

Corrigan, J. C.↗

Dynamics of Multistage Gear Transmission with Effects of Gearbox Vibrations

A comprehensive approach is presented in analyzing the dynamic behavior of multistage gear transmission systems with the effects of gearbox induced vibrations and mass imbalances of the rotor. The modal method, with undamped frequencies and planar mode shapes, is used to reduce the degrees of freedom of the gear system for time-transient dynamic analysis. Both the lateral and torsional vibration modes of each rotor-bearing-gear stage as well as the interstage vibrational characteristics are coupled together through localized gear mesh tooth interactions. In addition, gearbox vibrations are also coupled to the rotor-bearing-gear system dynamics through bearing support forces between the rotor and the gearbox. Transient and steady state dynamics of lateral and torsional vibrations of the geared system are examined in both time and frequency domains to develop interpretations of the overall modal dynamic characteristics under various operating conditions. A typical three-stage geared system is used as an example. Effects of mass imbalance and gearbox vibrations on the system dynamic behavior are presented in terms of modal excitation functions for both lateral and torsional vibrations. Operational characteristics and conclusions are drawn from the results presented.

Choy, F. K.↗