Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Toward 100% Renewable Power Grids: A Review

The transition to a 100% renewable power grid remains beset by significant technical challenges. This paper critically examines the obstacles arising from the variability and unpredictability of renewable energy sources (RES), which complicate the real-time balancing of power generation and load demand. In addition to traditional stability concerns (e.g., rotor angle, voltage, and frequency stability), the increasing penetration of inverter-based resources (IBRs) introduces novel challenges, including resonance stability issues and converter-driven dynamics. Moreover, the dynamic behavior and fault response of IBRs diverge markedly from those of conventional synchronous generators, rendering traditional protection schemes increasingly inadequate. This paper reviews state-of-the-art solutions in power balancing, grid flexibility, stability enhancement, and advanced protection strategies, discussing their implications for future grid design. The analysis provides a comprehensive assessment of recent technological advancements, thereby outlining critical research directions essential for achieving a resilient, 100% renewable power grid.

100% renewable power grid↗

Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS)

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an open-source tool for visualizing variable renewable resource forecasts and ramp alerts for significant up/down ramps in renewable resource and the consequent net-load. The modular dashboard of RAVIS contains configurable panes for viewing- probabilistic time series forecasts, ramp event alerts on the look-ahead timeline, spatially resolved resource sites and forecasts, and system simulation and market clearing data such as transmission lines utilization, nodal prices and available generation flexibility.

Krishnan, Venkat↗

Design Methods, Tools, and Data for Ceramic Solar Receivers

This report presents the development of tools and methods for evaluating the reliability and performance of ceramic materials in high temperature solar receivers. As Concentrating Solar Power (CSP) technologies aim for higher operating temperatures to enhance efficiency and meet industrial process heat requirements, current high temperature metallic materials face challenges in maintaining structural integrity. This report explores advanced ceramics as a promising alternative, given their superior high temperature strength and lower thermal expansion, compared to metals. To address the need for effective ceramic receiver design tools, this report integrates statistical failure models of ceramics into the existing srlife tool: an open-source software package designed to estimate the life of high temperature CSP components. These failure models account for the inherent variability and flaw distribution in ceramics, as well as the impact of subcritical crack growth under high temperature cyclic loads. The report also presents experimental data collected for a commercially available ceramic material, SiC, and details the process of estimating reliability model parameters from these data. A comparative design analysis is then performed between ceramic (SiC) and metallic (current nickel-based superalloys A740H and A282) receiver. This comparison demonstrates that SiC receivers can achieve service life exceeding 30 years under high incident heat flux conditions, compared to just a few years for metallic receivers.

14 SOLAR ENERGY↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Renewable hydrogen horizon: Geospatial techno-economic feasibility and life cycle greenhouse gas analysis in the Middle East and North Africa

Renewable hydrogen is receiving increasing attention for its potential as a flexible energy carrier in sectors such as transportation and industry. Specific cost and carbon intensity (CI) of renewable hydrogen production vary largely based on the location, owing to differences in renewable energy resources, as well as the supply chain dynamics. This study maps the techno-economic and life cycle greenhouse gas emissions of renewable hydrogen production in the Middle East and North Africa region, leveraging abundant solar and wind resources. The work investigates the variability in hydrogen costs and CI, optimally sizing proton-exchange membrane (PEM) electrolyzers to account for partial and cyclic loading, and explores standalone versus grid-connected systems. PEM capacity ratios of 52 %–63 % for photovoltaic (PV) systems and 28 %–82 % for wind systems were identified as optimal, with hydrogen production costs ranging from $\$3.8$-$\$4.8$/kg for PV and $2.0-$7.0/kg for wind. CIs span from 1.9 to 3.7 kg CO 2 ,eq /kg H 2 for PV and 0.4–7.7 kg CO 2,eq /kg H 2 for wind systems. The study highlights significant cost and CI reductions achievable with technological advancements and co-product revenue from oxygen and excess electricity sales.

Carbon Intensity↗

Late Holocene history of Tokotan Lake (Kuril Archipelago, Russian Far East): The use of lacustrine records for paleoclimatic reconstructions from geologically dynamic settings

A high-resolution, multiproxy analysis of a core from Tokotan Lake, Urup Island, illustrates the complex paleoenvironmental signals that can be preserved in sedimentary deposits from geologically active areas, such as the Kuril Archipelago. Diatom and geochemical analyses of the Tokotan core suggest a shallowing and lessening of the lake area over the last ~3450 cal BP. Without other proxies, the record could be interpreted as showing a general decrease in precipitation over the Late Holocene. However, palynological data indicate no change in vegetation, thereby implying no significant climatic variation. Neither of these paleoclimatic interpretations agrees with Late Holocene reconstructions from the Kuril Archipelago or the Russian mainland. Paleomagnetic data imply variable sediment sources during the lake's history, indicating alterations within the Tokotan catchment (e.g., shifts in gradients or sediment loads in the inflowing streams). Such changes would be particularly important in the Shabalina River, which today has formed a partial dam across the lake's outlet. Here, the results of the Tokotan study indicate that other factors (e.g., volcanism, seismic activity, sea-level changes) rather than climate were more probable determinants of the Late Holocene lake record. Given the geologic dynamism of the region, it is perhaps not surprising that paleo-records from the Kuril Islands display an inconsistency in the numbers and/or duration of proposed Holocene climatic oscillations, underscoring the importance of multiproxy investigations in areas that are or have been geologically dynamic.

58 GEOSCIENCES↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal variability of wake impacts on US mid-Atlantic offshore wind plant power production

Abstract. The mid-Atlantic will experience rapid wind plant development due to its promising wind resource located near large population centers. Wind turbines and wind plants create wakes, or regions of reduced wind speed, that may negatively affect downwind turbines and plants. We evaluate wake variability and annual energy production with the first yearlong modeling assessment using the Weather Research and Forecasting model, deploying 12 MW turbines across the domain at a density of 3.14 MW km−2, matching the planned density of 3 MW km−2. Using a series of simulations with no wind plants, one wind plant, and complete build-out of lease areas, we calculate wake effects and distinguish the effect of wakes generated internally within one plant from those generated externally between plants. We also provide a first step towards uncertainty quantification by testing the amount of added turbulence kinetic energy (TKE) by 0 % and 100 %. We provide a sensitivity analysis by additionally comparing 25 % and 50 % for a short case study period. The strongest wakes, propagating 55 km, occur in summertime stable stratification, just when New England's grid demand peaks in summer. The seasonal variability of wakes in this offshore region is much stronger than the diurnal variability of wakes. Overall, yearlong simulated wake impacts reduce power output by a range between 38.2 % and 34.1 % (for 0 %–100 % added TKE). Internal wakes cause greater yearlong power losses, from 29.2 % to 25.7 %, compared to external wakes, from 14.7 % to 13.4 %. The overall impact is different from the linear sum of internal wakes and external wakes due to non-linear processes. Additional simulations quantify wake uncertainty by modifying the added amount of turbulent kinetic energy from wind turbines, introducing power output variability of 3.8 %. Finally, we compare annual energy production to New England grid demand and find that the lease areas can supply 58.8 % to 61.2 % of annual load. We note that the results of this assessment are not intended to make nor are they suitable to make commercial judgments about specific wind projects.

17 WIND ENERGY↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dependence of the kinetic energy absorption capacity of bistable mechanical metamaterials on impactor mass and velocity

Using an alternative mechanism to dissipation or scattering, bistable structures and mechanical metamaterials have shown promise for mitigating the detrimental effects of impact by reversibly locking energy into strained material. Herein, we extend prior works on impact absorption via bistable metamaterials to computationally explore the dependence of kinetic energy transmission on the velocity and mass of the impactor, with strain rates exceeding 10 2 s –1 . We observe a large dependence on both impactor parameters, ranging from significantly better to worse performance than a comparative linear material. We then correlate the variability in performance to solitary wave formation in the system and give analytical estimates of idealized energy absorption capacity under dynamic loading. In addition, we find a significant dependence on damping accompanied by a qualitative difference in solitary wave propagation within the system. The complex dynamics revealed in this study offer potential future guidance for the application of bistable metamaterials to applications including human and engineered system shock and impact protection devices.

42 ENGINEERING↗

Control-oriented core-SOL-divertor model to address integrated burn and divertor control challenges in ITER

The real-time regulation of a burning plasma’s temperature and density, or burn control, will be necessary to produce high fusion power in future tokamaks like ITER. This is made more challenging due to the plasma’s nonlinear characteristics and the interdependence between the core-plasma and edge-plasma regions. For example, a raising plasma temperature leads to increasing reactivity and therefore to more alpha-particle heating, which further increases temperature. Furthermore, a raise of the fusion power increases the heat flow through the scrape-off-layer (SOL), which can compromise the integrity of the divertor without proper safeguards. For control design, a model-based approach is attractive because it can directly incorporate the nonlinear, coupled, burning-plasma dynamics into the design. To facilitate this design approach, a control-oriented core-SOL-divertor (CSD) model is presented in this work. In this CSD model, a core-plasma model captures the nonlinear dynamics of the core’s density and temperature, and a SOL-divertor model defines the plasma conditions at the separatrix and divertor including the heat load on the target plates. The core-plasma and SOL-divertor models are coupled through the exchange of various variables. In particular, the SOL-divertor model yields the separatrix temperature and the influx of recycled particles into the core-plasma. Further, these variables influence the power and particle balances captured by the core-plasma model. In return, the core-plasma model determines the intensity of the heat and particles fluxes across the separatrix, and this outflow strongly impacts the SOL-divertor model. Therefore, the power and density of the core-plasma, which can be readily modulated through external heating systems and pellet injection, can be viewed as control knobs for the SOL-divertor region in addition to the gas puffing. In simulations of the CSD model, it is demonstrated how external actuation can be utilized to meet burn control and divertor control objectives simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗