Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “value of data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Gravitational and higher-order form factors of the pion in chiral quark models

The gravitational form factor of the pion is evaluated in two chiral quark models and confronted with the recent full-QCD lattice data. We find good agreement for the case of the spectral quark model, which builds in the vector-meson dominance for the charge form factor. We derive a simple relation between the gravitational and electromagnetic form factors, holding in the considered quark models in the chiral limit. The relation implies that the gravitational mean squared radius is half the electromagnetic one. We also analyze higher-order quark generalized form factors of the pion, related to higher moments in the symmetric Bjorken X variable of the generalized parton distribution functions, and discuss their perturbative QCD evolution, which is needed to relate the quark-model predictions to the lattice data. The values of the higher-order quark form factors at t=0, computed on the lattice, also agree with our quark-model results within the statistical and method uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strange baryon electromagnetic form factors and SU(3) flavor symmetry breaking

We study the nucleon, Sigma and cascade octet baryon electromagnetic form factors and the effects of SU(3) flavor symmetry breaking from 2+1-flavor lattice calculations. We find that electric and magnetic radii are similar; the maximum discrepancy is about 10%. In the pion-mass region we explore, both the quark-component and full-baryon moments have small SU(3) symmetry breaking. We extrapolate the charge radii and the magnetic moments using three-flavor heavy-baryon chiral perturbation theory. The systematic errors due to chiral and continuum extrapolations remain significant, giving rise to charge radii for p and {sigma}{sup -} that are 3-4 standard deviations away from the known experimental ones. Within these systematics the predicted {sigma}{sup +} and {xi}{sup -} radii are 0.67(5) and 0.306(15) fm{sup 2}, respectively. When the next-to-next-to-leading order of heavy-baryon chiral perturbation theory is included, the extrapolated magnetic moments are less than 3 standard deviations away from Particle Data Group values, and the discrepancy is possibly due to remaining chiral and continuum extrapolation errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive K{sub S}{sup 0}K{sub S}{sup 0} Resonance Production in ep Collisions at HERA

Inclusive K{sub S}{sup 0}K{sub S}{sup 0} production in ep collisions at the DESY ep collider HERA was studied with the ZEUS detector using an integrated luminosity of 0.5 fb{sup -1}. Enhancements in the mass spectrum were observed and are attributed to the production of f{sub 2}(1270)/a{sub 2}{sup 0}(1320), f{sub 2}{sup '}(1525) and f{sub 0}(1710). Masses and widths were obtained using a fit which takes into account theoretical predictions based on SU(3) symmetry arguments, and are consistent with the Particle Data Group values. The f{sub 0}(1710) state, which has a mass consistent with a glueball candidate, was observed with a statistical significance of 5 standard deviations. However, if this state is the same as that seen in {gamma}{gamma}{yields}K{sub S}{sup 0}K{sub S}{sup 0}, it is unlikely to be a pure glueball state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In Silico Measurement of Elastic Moduli of Nematic Liquid Crystals

Experiments on confined droplets of the nematic liquid crystal 5CB have questioned long-established bounds imposed on the elastic free energy of nematic systems. This elasticity, which derives from molecular alignment within nematic systems, is quantified through a set of moduli which can be difficult to measure experimentally and, in some cases, can only be probed indirectly. This is particularly true of the surfacelike saddle-splay elastic term, for which the available experimental data indicate values on the cusp of stability, often with large uncertainties. Here, we demonstrate that all nematic elastic moduli, including the saddle-splay elastic constant k 24 , may be calculated directly from atomistic molecular simulations. Importantly, results obtained through in silico measurements of the 5CB elastic properties demonstrate unambiguously that saddle-splay elasticity alone is unable to describe the observed confined morphologies.

36 MATERIALS SCIENCE↗

Modeling and Simulation of High-Frequency Solar Irradiance

As the use of solar power as a source of electricity is increasing, so is the interest in modeling radiation at high temporal resolutions. High-dimensional remote sensing data products depend on cloud cover variability, atmosphere aerosol levels, and other atmospheric parameters. Because of weather fronts and aerosols, it is difficult to quantify solar power variability based on distributed solar networks. The global horizontal irradiance (GHI) component in the National Solar Radiation Database (NSRDB) is available at a 30-min time resolution. The algorithm proposed in this paper produces 1-min-resolution GHI samples at locations where NSRDB data are available. The synthetic irradiance datasets are produced using log-additive non-Gaussian mixture models and resampling techniques. The model is trained over historical data, and predicted values are compared with in situ data. This approach allows for estimating the solar irradiance at subhourly temporal resolutions, while featuring variability for locations where measurements are otherwise not available.

14 SOLAR ENERGY↗

Spectral indices measurements using miniature fission chambers at the MINERVE zero-power reactor at CEA using calibration data obtained at the BR1 reactor at SCK.CEN

Spectral indices measurements performed in 2004 at the CEA MINERVE facility loaded with the R-UO{sub 2} lattice, using calibration data acquired at the SCK center dot CEN BR1 facility in 2001, resulted in ambivalent conclusions. On one hand, spectral indices involving only fissile isotopes gave consistent discrepancies between calculation and experiment. On the other hand, spectral indices involving both fissile and fertile isotopes, in particular the {sup 238}U(n, f)/{sup 235}U(n, f) spectral index, showed inconsistent results depending on the type of calibration data used. For different reasons, no definitive explanation was given at that time. In 2009, the preparation of the AMMON program at the EOLE facility motivated the manufacturing of a new set of detectors. At the same time, the re-installation of the R1-UO{sub 2} lattice in MINERVE provided the opportunity to carry out again a spectral indices measurement campaign. Nevertheless, although the isotopic compositions of active deposits were better known than previously, the comparison between experimental results and calculations still lead to inconsistent discrepancies. In April 2010, a new calibration series conducted again at the BR1 facility allowed the CEA to reanalyze the spectral indices measurements performed in 2009. With these very latest calibration data, experimental values of spectral indices finally matched calculations within the uncertainty margins. This paper also sums up the work that has been achieved to explain the incoherencies observed in 2004. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Water use and radiation balance of miscanthus and corn on marginal land in the coastal plain region of North Carolina

Abstract Miscanthus is a perennial grass that can yield substantial amounts of biomass in land areas considered marginal. In the Coastal Plain region of North Carolina, marginal lands are typically located in coarse‐textured soils with low nutrient retention and water‐holding capacity, and high erosivity potential. Little is known about miscanthus water use under these conditions. We conducted a study to better understand the efficiency with which miscanthus uses natural resources such as water and radiant energy to produce harvestable dry biomass in comparison to corn, a typical commodity crop grown in the region. We hypothesized that under non‐limiting soil water conditions, miscanthus would have greater available energy and water use rates owing to its greater leaf area, thus leading to greater agronomic yields. Conversely, these effects would be negated under drought conditions. Our measurements showed that miscanthus intercepted more radiant energy than corn, which led to greater albedo (by 0.05), lower net radiation (by 4% or 0.4 MJ m −2 day −1 ), and lower soil heat flux (by 69% or 1.0 MJ m −2 day −1 ) than corn on average. Consequently, miscanthus had greater available energy (by 7% or 0.6 MJ m −2 day −1 ) and water use rates (by 14% or 0.5 mm day −1 ) than corn throughout the growing season on average, which partially confirmed our hypothesis. Greater water use rates and radiation interception by miscanthus did not translate to greater water‐use (1.5 g kg −1 vs. 1.6 g kg −1 ) and radiation‐use (0.9 g MJ −1 vs. 1.1 g MJ −1 ) efficiencies than corn. Compared to literature values, our data indicated that water and radiation availability were not limiting at our study site. Thus, it is likely that marginal land features present at the Coastal Plain region such as low soil fertility and high air temperatures throughout the growing season may constrain agronomic yields even if soil water and radiant energy are non‐limiting.

Carvalho, Henrique D. R.↗

4D dose-position verification in radiation therapy using the RADPOS system in a deformable lung phantom

Purpose: A novel 4D in vivo dosimetry system (RADPOS), in conjunction with a deformable lung phantom, has been evaluated as a potential quality assurance tool for 4D radiotherapy. Methods: RADPOS detectors, which consist of a MOSFET dosimeter combined with an electromagnetic positioning probe, were placed inside the deformable lung phantom. One detector was positioned directly inside a tumor embedded in the lung phantom and another was positioned inside the lung portion of the phantom, outside the tumor. CT scans were taken with the phantom at three breathing phases, and for each phase, the detector position inside the phantom was read with the RADPOS software and compared to the position as determined from the CT data. These values were also compared to RADPOS measurements taken with the phantom on the couch of a Varian Clinac 6EX linac. The deformable phantom and the RADPOS system were also used in two radiation delivery scenarios: (1) A simulation of a free-breathing delivery and (2) a simulation of an adaptive treatment. Results: Compared to CT imaging, the RADPOS positional accuracy was found to be better than 2.5 mm. The radial displacement measurements taken in the CT and linac rooms agreed to within an average of (0.7{+-}0.3) mm. Hence, the system can provide relative displacement measurements in the treatment room, consistent with measurements made in the CT room. For the free-breathing delivery, the total dose reported by RADPOS agreed to within 4% and 5% of the treatment planning doses in the tumor and the lung portion of the phantom, respectively. The RADPOS-measured dose values for the adaptive delivery were within 1.5% of the treatment plan values, which was well within the estimated experimental uncertainties. Conclusions: This work has shown that the deformable lung phantom-RADPOS system can be an efficient quality assurance tool for 4D radiation therapy.

60 APPLIED LIFE SCIENCES↗

Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms

Purpose: Positron emission tomography (PET) plays an important role in the diagnosis, staging, treatment, and surveillance of clinically localized diseases. Combined PET/CT imaging exhibits significantly higher sensitivity, specificity, and accuracy than conventional imaging when it comes to detecting malignant tumors in children. However, the radiation dose from positron-emitting radionuclide to the pediatric population is a matter of concern since children are at a particularly high risk when exposed to ionizing radiation.Methods: The authors evaluate the absorbed fractions and specific absorbed fractions (SAFs) of monoenergy photons/electrons as well as S-values of 9 positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, Y-86, and I-124) in 48 source regions for 10 anthropomorphic pediatric hybrid models, including the reference newborn, 1-, 5-, 10-, and 15-yr-old male and female models, using the Monte Carlo N-Particle eXtended general purpose Monte Carlo transport code.Results: The self-absorbed SAFs and S-values for most organs were inversely related to the age and body weight, whereas the cross-dose terms presented less correlation with body weight. For most source/target organ pairs, Rb-82 and Y-86 produce the highest self-absorbed and cross-absorbed S-values, respectively, while Cu-64 produces the lowest S-values because of the low-energy and high-frequency of electron emissions. Most of the total self-absorbed S-values are contributed from nonpenetrating particles (electrons and positrons), which have a linear relationship with body weight. The dependence of self-absorbed S-values of the two annihilation photons varies to the reciprocal of 0.76 power of the mass, whereas the self-absorbed S-values of positrons vary according to the reciprocal mass.Conclusions: The produced S-values for common positron-emitting radionuclides can be exploited for the assessment of radiation dose delivered to the pediatric population from various PET radiotracers used in clinical and research settings. The mass scaling method for positron-emitters can be used to derive patient-specific S-values from data of reference phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of cardiac output from dynamic pulmonary circulation time CT

Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA, which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solutions of independent DGLAP evolution equations for the gluon distribution and singlet structure functions in the next-to-leading order at low x

We present a set of independent formulas to extract the gluon distribution and the singlet structure function from its derivatives with respect to lnQ{sup 2} in the next-to-leading order of perturbation theory at low x based on a hard Pomeron exchange. In this approach, both singlet quarks and gluons have the same high-energy behavior at small x. This approach requires the QCD input parameterizations for independent DGLAP evolutions, which we calculated numerically and compared with the MRST, GRV, and DL models. The Pomeron has a hard nature. Its evolution gives a good fit to the experimental data. The values obtained are in the range 10{sup -4} {<=} x {<=} 10{sup -2} at Q{sup 2} = 20 GeV{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Critical behavior of phase interfaces in porous media: Analysis of scaling properties with the use of noncoherent and coherent light

Image sequences of the surface of disordered layers of porous medium (paper) obtained under noncoherent and coherent illumination during capillary rise of a liquid are analyzed. As a result, principles that govern the critical behavior of the interface between liquid and gaseous phases during its pinning are established. By a cumulant analysis of speckle-modulated images of the surface and by the statistical analysis of binarized difference images of the surface under noncoherent illumination, it is shown that the macroscopic dynamics of the interface at the stage of pinning is mainly controlled by the power law dependence of the appearance rate of local instabilities (avalanches) of the interface on the critical parameter, whereas the growth dynamics of the local instabilities is controlled by the diffusion of a liquid in a layer and weakly depends on the critical parameter. A phenomenological model is proposed for the macroscopic dynamics of the phase interface for interpreting experimental data. The values of critical indices are determined that characterize the samples under test within this model. These values are compared with the results of numerical simulation for discrete models of directed percolation corresponding to the Kardar-Parisi-Zhang equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetocaloric properties of La{sub 1-x}KxMnO{sub 3} manganites

A technology for obtaining single-phase ceramic samples of La{sub 1-x}K{sub x}MnO{sub 3} manganites, as well as the dependence of their structure parameters on the potassium content, is described. The magnetocaloric effect in the samples has been measured by two direct methods, the classical method and the magnetic field modulation method, and has been calculated from the specific heat data. The values of the magnetocaloric effect obtained by these methods are significantly different. The observed discrepancies have been explained. Correlation between the doping level and the value of the effect has been found. It has been shown that the magnetic-field dependence of variation of the magnetic entropy near T{sub C} in weak fields corresponds to theoretical calculations and that the value of the magnetocaloric effect in high magnetic fields can be predicted using this dependence.

36 MATERIALS SCIENCE↗

Folding model analysis of pion elastic and inelastic scattering from {sup 6}Li and {sup 12}C

{pi}{sup {+-}}-Nucleus scattering cross sections are calculated applying the Watanabe superposition model with a phenomenological Woods-Saxon potential. The phenomenological potential parameters are searched for {pi}{sup {+-}} scattering from {sup 6}Li and {sup 12}C to reproduce not only differential elastic cross sections but also inelastic and total and reaction cross sections at pion kinetic energies from 50 to 672 MeV. The optical potentials of {sup 6}Li and {sup 12}C are calculated in terms of the alpha particle and deuteron optical potentials. Inelastic scattering has been analyzed using the distorted waves from elastic-scattering data. The values of deformation lengths thus obtained compare very well with the ones reported earlier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved measurement of the absolute branching fraction of $D^{+}\rightarrow \bar{K}^0 \mu ^{+}\nu _{\mu }$

Here, by analyzing 2.93 fb -1 of data collected at √s = 3.773 GeV with the BESIII detector, we measure the absolute branching fraction B(D + → K¯ 0 μ + ν μ ) = (8.72 ± 0.07 stat. ± 0.18 sys. )%, which is consistent with previous measurements within uncertainties but with significantly improved precision. Combining the Particle Data Group values of B(D 0 → K - μ + ν μ ), B(D + → K¯ 0 e + ν e ), and the lifetimes of the D 0 and D + mesons with the value of B(D + → K¯ 0 μ + ν μ ) measured in this work, we determine the following ratios of partial widths: Γ(D 0 → K - μ + ν μ )/Γ(D + → K¯ 0 μ + ν μ ) = 0.963 ± 0.044 and Γ(D + → K¯ 0 μ + ν μ )/Γ(D + → K¯ 0 e + ν e ) = 0.988 ± 0.033.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pretargeted Radioimmunotherapy Using Anti-CD45 Monoclonal Antibodies to Deliver Radiation to Murine Hematolymphoid Tissues and Human Myeloid Leukemia

The efficacy of radioimmunotherapy (RIT) for treatment of patients with hematological malignancies frequently fails because of disease recurrence. We therefore conducted pretargeted RIT studies to augment the efficacy in mice of therapy using a pretargeted anti-human (h)CD45 antibody (Ab)-streptavidin (SA) conjugate followed by delivery of a biotinylated clearing agent and radiolabeled-DOTA-biotin. Tumor-to-blood ratios at 24 hours were 20:1 using pretargeted anti-hCD45 RIT and <1:1 with conventional RIT. In vivo imaging studies confirmed that the pretargeted RIT approach provided high-contrast tumor images with minimal blood-pool activity, whereas directly-labeled anti-hCD45 Ab produced distinct tumor images but the blood pool retained a large amount of labeled antibody for a prolonged time. Therapy experiments demonstrated that 90Y-DOTA-biotin significantly prolonged survival of mice treated pretargeted with anti-hCD45 Ab-SA compared to mice treated with conventional RIT using 90Y-labeled anti-hCD45 Ab at the maximally tolerated dose (400 µCi). Since human CD45 antigens are confined to xenograft tumor cells in this model, and all murine tissues are devoid of hCD45 and will not bind anti-hCD45 Ab, we also compared one-step and pretargeted RIT using an anti-murine (m)CD45 Ab (A20 ) in a model where the target antigen is present on normal hematopoietic tissues. After 24 hours, 27.3 ± 2.8% of the injected dose of radionuclide was delivered per gram (% ID/g) of lymph node using 131I-A20-Ab compared with 40.0 ± 5.4% ID/g for pretargeted 111In-DOTA-biotin (p value). These data suggest that multi-step pretargeted methods for delivering RIT are superior to conventional RIT when targeting CD45 for the treatment of leukemia and may allow for the intensification of therapy, while minimizing toxicities.

60 APPLIED LIFE SCIENCES↗

AbacusSummit Halo Light Cone Catalogs

This is a set of halo light cone catalogs from the AbacusSummit suite of cosmological N-body simulations (abacussummit.readthedocs.io/). They are a value-added data product provided by post-processing the simulation output. The main application of the halo light cone catalogs is the construction of realistic mock galaxy catalogues and weak lensing maps on the sky. The algorithm (described in Hadzhiyska et al. 2021) associates CompaSO halos from 29 redshift epochs spanning z = 0.1-2.5 with their particles at the time of light-cone crossing. It then records the halo and particle information into an easily accessible product, which can be read with the CompaSO reader. The 25 base resolution boxes at fiducial cosmology have a halo light cone catalog covering an octant of the sky to z approx 0.8 and about 2000 deg2 extending to z approx 2.4. The huge boxes provide light cone information of the full sky until z approx 2.18 and extend further towards the corners of the box (available until z = 2.25). Galaxy mock catalogs on the sky can be generated easily though the AbacusHOD script providing an extended HOD framework (see Yuan et al. 2021, for details), which has been modified to work with the halo light cone catalogs. The available tracers are luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs).

79 ASTRONOMY AND ASTROPHYSICS↗

Extreme Significant Wave Heights for US Coastal Waters

Includes extreme significant wave heights, in meters, computed using peaks over threshold method on NOAA 30-year WWIII hindcast data. Extreme values for 5, 10, 25, 50, and 100 year return periods were computed. Sites cover US coastlines. Column 1: Site identifier/name Column 2: Site latitude Column 3: Site longitude Column 4: 5-year extreme Hs, in meters Column 5: 10-year extreme Hs, in meters Column 6: 25-year extreme Hs, in meters Column 7: 50-year extreme Hs, in meters Column 8: 100-year extreme Hs, in meters

16 TIDAL AND WAVE POWER↗