Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrahigh vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Molecular wake shield gas analyzer

Techniques for measuring and characterizing the ultrahigh vacuum in the wake of an orbiting spacecraft are studied. A high sensitivity mass spectrometer that contains a double mass analyzer consisting of an open source miniature magnetic sector field neutral gas analyzer and an identical ion analyzer is proposed. These are configured to detect and identify gas and ion species of hydrogen, helium, nitrogen, oxygen, nitric oxide, and carbon dioxide and any other gas or ion species in the 1 to 46 amu mass range. This range covers the normal atmospheric constituents. The sensitivity of the instrument is sufficient to measure ambient gases and ion with a particle density of the order of one per cc. A chemical pump, or getter, is mounted near the entrance aperture of the neutral gas analyzer which integrates the absorption of ambient gases for a selectable period of time for subsequent release and analysis. The sensitivity is realizable for all but rare gases using this technique.

Hoffman, J. H.↗

Materials processing in space bibliography

Literature dealing with flight experiments utilizing a low gravity environment to elucidate and control various processes or with ground based activities that provide supporting research is listed. Included are Government reports, contractor reports, conference proceedings, and journal articles. Subdivisions of the bibliography include the five categories: crystal growth; metals, alloys, and composites, fluids and transport; glasses and ceramics; and Ultrahigh Vacuum and Containerless Processing Technologies, in addition to a list of patents and a compilation of anonymously authored collections and reports and a cross reference index.

Pentecost, E.↗

Hydrogen partitioning in pure cast aluminum as determined by dynamic evolution rate measurements

Hydrogen in pure aluminum can be found in two different states. One is related to a presence in gas-filled pores, while the other state involves the formation of a solid solution between hydrogen and aluminum. The considered investigation is concerned with the distribution of the hydrogen between various states. A dynamic technique is employed to measure the evolution of hydrogen from commercially available samples of polycrystalline pure aluminum under ultrahigh vacuum conditions. The obtained data are compared with the results of a statistical analysis concerning the porosity in the cast aluminum. It was found that more than 99 pct of the hydrogen in the aluminum is located in large pores. Less than 1 pct of the hydrogen is partitioned between the solid solution and the small pores.

Outlaw, R. A.↗

Surface morphology of erbium silicide

The surface of rare-earth silicides (Er, Tb, etc.), formed by the reaction of thin-film metal layers with a silicon substrate, is typically dominated by deep penetrating, regularly shaped pits. These pits may have a detrimental effect on the electronic performance of low Schottky barrier height diodes utilizing such silicides on n-type Si. This study suggests that contamination at the metal-Si or silicide-Si interface is the primary cause of surface pitting. Surface pits may be reduced in density or eliminated entirely through either the use of Si substrate surfaces prepared under ultrahigh vacuum conditions prior to metal deposition and silicide formation or by means of ion irradiation techniques. Silicide layers formed by these techniques possess an almost planar morphology.

Lau, S. S.↗

Pressure pulsations above turbomolecular pumps

Lange and Singleton (1978) have observed pressure pulses above a turbomolecular pump. They reported that the mean pulse frequency increased with the temperature of the pump cooling water and that the evolved gas was mainly hydrogen. The present investigation takes into account tests conducted with a similar pumping system. The pumping system was equipped with additional pressure-monitoring equipment in order to study these pulsations in more detail. It was found that at least two distinct types of pressure pulsations may be present in a turbomolecular-pumped ultrahigh vacuum system. The random hydrogen pulses are easily eliminated for period of days by changing the cooling water temperature. The cyclic pulses consisting mainly of water vapor are not likely to be a problem in normal experiments.

Danziger, S.↗

Materials processing in space program tasks

Active research areas as of the end of the fiscal year 1982 of the Materials Processing in Space Program, NASA-Office of Space and Terrestrial Applications, involving several NASA centers and other organizations are highlighted to provide an overview of the program scope for managers and scientists in industry, university, and government communities. The program is described as well as its history, strategy and overall goal; the organizational structures and people involved are identified and each research task is described together with a list of recent publications. The tasks are grouped into four categories: crystal growth; solidification of metals, alloys, and composites; fluids, transports, and chemical processes; and ultrahigh vacuum and containerless processing technologies.

Pentecost, E.↗

Materials processing in space bibliography, 1983, revised

Flight experiments utilizing a low gravity environment to elucidate and control various processes, or ground based activities that provide supporting research are compiled. Six major categories: crystal growth; solidification of metals, alloys, and composites; fluids, transports, and chemical processes; glasses and ceramics; ultrahigh vacuum and containerless processing technologies; and combustion are included. A list of patents and appendices providing a compilation of anonymously authored collections and reports and a cross reference index are included.

Pentecost, E.↗

Materials processing in space program tasks

Crystal growth; solidification of metals, alloys, and composites; fluids, transports, and chemical processes; and ultrahigh vacuum and containerless technologies are discussed.

Pentecost, E.↗

Materials processing in space program tasks-supplement

An overview of the program scope for managers and scientists in industry, university, and government communities is provided. An introductory description of the program, its history, strategy, and overall goals; identification of the organizational structures and people involved; and a description of each research task, together with a list of recent publications are included. The tasks are grouped into six categories: crystal growth; solidification of metals, alloys, and composites; fluids, transports, and chemical processes; and ultrahigh vacuum and containerless processing technologies; combustion experiments; and experimental technology.

Pentecost, E.↗

Effect of ion sputtering on interface chemistry and electrical properties of Au GaAs(100) Schottky contacts

The effects of sputtering n-type (100)GaAs with 1 to 5 keV argon ions have been studied in ultrahigh vacuum. Auger electron and X-ray photoelectron spectroscopies have been used to characterize the surface before and after sputtering. Gold Schottky contacts were prepared in situ to avoid contamination at the metal/semiconductor interface. The data show that sputtering depletes the surface in As, and the extent of depletion increased as the ion energy was increased. However, angular-resolved photoelectron data showed As was enriched on the outer atom layer by 5 keV but depleted by 1 keV Ar(+) sputtering. Current and capacitance versus voltage data showed that sputtering always lowered the Schottky barrier height and generally increased the ideality factor. However, the barrier height after 3 keV sputtering was higher than after 1 keV sputtering. Those effects are explained based on a combined effective work function model and creation of a donorlike surface damage layer. The donor layer was correlated with As depletion by sputtering. Deep level trap formation and annealing of sputtering effects were studied.

Wang, Y.-X.↗

Metal-support interactions during the adsorption of CO on thin layers and islands of epitaxial palladium

Islands and continuous layers of palladium were grown in an ultrahigh vacuum on substrates of Mo(110)c(14 x 7)-O, designated MoO(x), and of clean Mo(110). It was found that as-deposited islands and layers exhibited bulk palladium adsorption properties for CO when deposited at room temperature and for palladium thicknesses in excess of about 3 monolayers. CO adsorption was drastically reduced, however, on annealing. For islands, annealing temperatures of as low as 400 K led to some reduction in CO adsorption whereas more severe reductions were found to occur at 600 K for islands and at 800 K for continuous multilayers. The deactivation depended on the palladium thickness, the substrate species and the extent of thermal treatments. Auger electron spectroscopy, temperature-programmed desorption and Delta-Phi measurements were combined to interpret the deactivation behavior in terms of substrate-support interactions involving the diffusion of substrate species towards the palladium surface.

Park, C.↗

Decomposition of ethylene on small Pd particles

New results have been obtained which contribute to the understanding of hydrocarbon reactions on the surface of highly dispersed metal systems. Small particle of Pd were grown by electron beam evaporation on cleavage planes of high purity natural mica under ultrahigh vacuum conditions. Samples were subsequently characterized by transmission electron microscopy. Average particle sizes ranged from about 1 to 10 nm diameter. The chemisoption and decomposition of C2H4 on the Pd particles was studied using Auger electron spectroscopy and flash thermal desorption. It is shown that (a) C2H4 decomposes on Pd particles at room temperature, (b) specific surface sites are causing decomposition, and (c) the proportion of such active sites is significantly greater for the smaller metal particles. This enhanced reactivity may be due to an increase in the density of step, corner, and edge sites with a decrease in particle size.

Durrer, W. G.↗

Report on opportunities and/or techniques for high-caliber experimental research (other) proposals for SSPEX

Brief discriptions of the following 13 experiments are included: ultrahigh vacuum petrology facility; artificial comet free flyer; artificial comet (tethered); cosmic dust detector; cosmic dust collector; dust collection using tethered satellites; artificial magnetosphere; microgravity petrological studies; slitless ultraviolet spectrometer; orbital determination and capture experiment (ODACE); high velocity sputtering of amorphous silicates; particle release experiments; and calibration of gamma and X-ray remote sensingprobes.

Nuth, J. A., III↗

The Correlation of Structural, Chemical, and Electronic Properties of Small Metal Particles and Their Alloys

The low pressure interaction of CO with small Ru particles supported on ultrahigh vacuum (UHV) cleaved mica was studied using flash thermal desorption, Auger electron microscopy, transmission electron microscopy, and transmission electron diffraction. Average particle sizes for these experiments varied between 1.2 and 16 nm. A careful search for CO decomposition on the Ru particles revealed no evidence of dissociaiton over a temperature range and pressure range of 300 to 550 C and 10 to the minus 11th power to 10 to the minus 6th millibar, respectively. Cas and heat treatments caused significant morphological changes and dispersion in the Ru particles, which affected CO desorptiom These effects were dependent on the particle size.

Source record↗

Preparation and analysis of particulate metal deposits

Small particles and clusters of palladium were grown by deposition from the vapor phase under ultrahigh vacuum conditions. Amorphous and crystalline support films of Al2O3 and ultrathin amorphous carbon films were used as substrate materials. The growth of the metal deposit was monitored in situ by scanning transmission diffraction of energy-filtered 100 kV electrons and high resolution transmission electron microscopy (TEM) analysis was performed in a separate instrument. It was established by in situ TEM, however, that the transfer of specimens in this case did not unduly affect the size and distribution of deposit particles. It was found that the cleanness, stoichiometry, crystallinity and structural perfection of the support surface play an essential role in determining the crystalline perfection and structure of the particles. The smallest palladium clusters reproducibly prepared contained not more than six atoms but size determinations below 1 nm average particle diameter are very problematic with conventional TEM. Palladium particles grown on carbon supports feature an impurity-stabilized mosaic structure.

Poppa, H.↗

Surface modification strategies for (100)3C-SiC

Several surface modificaation techniques were performed in situ in an ultrahigh vacuum as part of a program to develop electrical contacts on the (100) face of cubic SiC. The Auger electron spectroscopy line shapes and peak-to-peak heights of the Si LVV and CKLL transitions indicated changes in surface stoichiometry, bonding, and short range order. Changes in the low-energy electron diffraction pattern identified changes in the symmetry of long range ordering on the surface. Heating above 1050 C depleted the surface of Si with an activation energy of 120 kcal/mol, resulting eventually in a disordered graphitic layer which was several atomic layers thick. Bombardment by Ar ions of energies greater than 1000 eV enhanced the Si to C ratio on the surface and destroyed the LEED pattern. Long range order was recovered by simultaneous heating and ion bombardment. Finally, adsorption of Cr on the Ar ion damaged surface and subsequent desorption left a reconstructed, p(2 x 1)Si enriched surface. Similar treatments with Al did not produce a surface reconstruction.

Bellina, J. J., Jr.↗

Electron stimulated desorption of atomic oxygen from silver

The electron stimulated desorption (ESD) of neutral oxygen atoms from polycrystalline silver and of oxygen ions from Ag(110) has been studied. Polycrystalline Ag charged with (16)O2 and (18)O2 and bombarded by low-energy electrons (approx 100 eV) under ultrahigh vacuum (UHV) conditions emitted O atom flux levels of 1 x 10 to the 12th power/sq cm/s at a Ag temperature of 300 C. The flux was detected with a quadrupole mass spectrometer operating in the appearance potential mode. The neutral cross section at about 100 C was determined to be 7 x 10 to the -19 sq cm. Ancillary experiments conducted in a UHV chamber equipped with a cylindrical mirror analyzer and rigged for ion energy distribution and ion angular distribution were used to study O ions desorbed from Ag(110). Two primary O(+) energies of 2.4 and 5.4 eV were detected from the Ag(110) after having been dosed with 2500 L of (16)O2. It also appears that in both experiments there was strong evidence for directionality of the emitted flux. The results of this study serve as a proof of concept for the development of a laboratory atomic oxygen beam generator that simulates the gas flux environment experienced by orbiting vehicles.

Outlaw, R. A.↗

Surface temperature determination in surface analytic systems by infrared optical pyrometry

An IR pyrometric technique for measuring the surface temperatures of metal specimens in an ultrahigh-vacuum analytic chamber is described and demonstrated. The experimental setup comprises a commercial IR microscope with a long-working-distance right-angle objective (focal spot diameter 1 mm at 53 cm), a metal-coated glass vacuum chamber with a Ta-mesh-covered quartz viewport, an Mo specimen stub with an internal heating element, and a Ta disk test specimen with a flat side coated with a high-emissivity graphite film. The results of an initial calibration test are presented graphically and briefly characterized. The measurement error at 450 C is found to be less than 10 C.

Wheeler, Donald R.↗