Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “two’s complement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multi-objective decision-making under uncertainty: Fuzzy logic methods

Fuzzy logic allows for quantitative representation of vague or fuzzy objectives, and therefore is well-suited for multi-objective decision-making. This paper presents methods employing fuzzy logic concepts to assist in the decision-making process. In addition, this paper describes software developed at NASA Lewis Research Center for assisting in the decision-making process. Two diverse examples are used to illustrate the use of fuzzy logic in choosing an alternative among many options and objectives. One example is the selection of a lunar lander ascent propulsion system, and the other example is the selection of an aeration system for improving the water quality of the Cuyahoga River in Cleveland, Ohio. The fuzzy logic techniques provided here are powerful tools which complement existing approaches, and therefore should be considered in future decision-making activities.

Hardy, Terry L.↗

Remote Sensing Capabilities to Detect Maritime Vessels in Distress

The National Aeronautics and Space Administration (NASA) has the responsibility for conducting research and development for search and rescue as charged under the National Search and Rescue Plan. For over two decades this task has been undertaken by the Search and Rescue Mission Office at the NASA Goddard Space Flight Center (GSFC). The technology used by the highly successful beacon locating satellite system, Cospas-Sarsat, was conceived and developed at GSFC and is managed by the National Oceanographic and Atmospheric Administration (NOAA). Using beacon-less remote sensing to find people and vessels in distress complements the demonstrated life saving capabilities of this satellite system. The Search and Rescue Mission Office has been investigating the use of fully polarimetric synthetic aperture radar to locate crashed aircraft. An overview of this effort and potential maritime applications of Search and Rescue Synthetic Aperture Radar (SAR) will be presented. The Mission Office has also developed a Laser search and rescue system called L-SAR. The prototype instrument was designed and built by SenSyTech Inc. It specifically targets the location of novel retro-reflective material easily applied to rescue equipment and vessels in distress. An overview of this effort will also be presented.

Larsen, Rudolph K.↗

A Comparison of Foliage Profiles in the Sierra National Forest Obtained with a Full-Waveform Under-Canopy EVI Lidar System with the Foliage Profiles Obtained with an Airborne Full-Waveform LVIS Lidar System

Foliage profiles retrieved froma scanning, terrestrial, near-infrared (1064 nm), full-waveformlidar, the Echidna Validation Instrument (EVI), agree well with those obtained from an airborne, near-infrared, full-waveform, large footprint lidar, the Lidar Vegetation Imaging Sensor (LVIS). We conducted trials at 5 plots within a conifer stand at Sierra National Forest in August, 2008. Foliage profiles retrieved from these two lidar systems are closely correlated (e.g., r = 0.987 at 100 mhorizontal distances) at large spatial coverage while they differ significantly at small spatial coverage, indicating the apparent scanning perspective effect on foliage profile retrievals. Alsowe noted the obvious effects of local topography on foliage profile retrievals, particularly on the topmost height retrievals. With a fine spatial resolution and a small beam size, terrestrial lidar systems complement the strengths of the airborne lidars by making a detailed characterization of the crowns from a small field site, and thereby serving as a validation tool and providing localized tuning information for future airborne and spaceborne lidar missions.

Full-waveform↗

TCL3 UTM (UAS Traffic Management) Flight Tests, Airspace Operations Laboratory (AOL) Report

The Technology Capability Level-3 (TCL3) flight tests were conducted at six different test sites located across the USA from March to May of 2018. The campaign resulted in over 830 data collection flights using 28 different aircraft and involving 20 flight crews. Flights not only varied in duration, but also in the environments and terrains over which they flew. The TCL3 tests highlighted four different types of tests: three tests focused on Communication, Navigation and Surveillance (CNS); six tests focused on Sense and Avoid (SAA) technologies; six tests focused on USS Data and Information Exchange (DAT); and five tests focused on exploring fundamental Concepts of the project (CON). This document presents data collected during the TCL3 tests that informed the operator’s experiences—the quality of the unmanned aerial system (UAS) Service Supplier (USS) information that the operator was provided with, the usefulness of this information, and the usability of the automation, both while airborne and on the ground. It is intended to complement the reports written by the test sites and the quantitative reports and presentations of the UAS Traffic Management (UTM) project. With the goal of instructing what the minimum information requirements and/or best practices might be in TCL3 operations, the driving enquiry was: How do you get the information you need, when you need it, to successfully fly a UAS in UTM airspace? This enquiry touches on two requirements for displays, which are to provide adequate situation awareness (SA) and to share information through a USS. The six test sites participating in the TCL3 tests flew a subset of the 20 tests (outlined above), with most sites working on a subset of each of the four types: Communications, Navigation and Surveillance (CNS); DAT; CON; and Sense and Avoid (SAA). The, mainly qualitative, data addressed in this report was collected by the AOL (Airspace Operations Laboratory) both on-site and remotely for each test. The data consists of the contents of end-of-day debriefs, end-of-day surveys, observer notes, and flight test information, all submitted as part of the Data Management Plan (DMP).

Martin, Lynne↗

Bio-medical electrical disconnects

Improvements in medical care during the last two decades have resulted in the survival of an ever-increasing group of patients with severe neuro-muscular disabilities who otherwise would have succumbed to their diseases or injuries. This has created a sizeable population of severely paralyzed persons totally dependent upon society for care. It has been estimated that this population may grow beyond 5,000,000 persons by 1980. A rather fortunate confluence of complementing technologies and surgical techniques offer promise of solving this growing socially significant problem.

Parsons, W. E.↗

Wind-US Code Physical Modeling Improvements to Complement Hypersonic Testing and Evaluation

This report gives an overview of physical modeling enhancements to the Wind-US flow solver which were made to improve the capabilities for simulation of hypersonic flows and the reliability of computations to complement hypersonic testing. The improvements include advanced turbulence models, a bypass transition model, a conjugate (or closely coupled to vehicle structure) conduction-convection heat transfer capability, and an upgraded high-speed combustion solver. A Mach 5 shock-wave boundary layer interaction problem is used to investigate the benefits of k- s and k-w based explicit algebraic stress turbulence models relative to linear two-equation models. The bypass transition model is validated using data from experiments for incompressible boundary layers and a Mach 7.9 cone flow. The conjugate heat transfer method is validated for a test case involving reacting H2-O2 rocket exhaust over cooled calorimeter panels. A dual-mode scramjet configuration is investigated using both a simplified 1-step kinetics mechanism and an 8-step mechanism. Additionally, variations in the turbulent Prandtl and Schmidt numbers are considered for this scramjet configuration.

Georgiadis, Nicholas J.↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

Overview of Primitive Object Volatile Explorer (PrOVE) CubeSat or Smallsat Concept

Here we describe the Primitive Object Volatile Explorer (PrOVE), a smallsat mission concept to study the surface structure and volatile inventory of comets in their perihelion passage phase when volatile activity is near peak. CubeSat infrastructure imposes limits on propulsion systems, which are compounded by sensitivity to the spacecraft disposal state from the launch platform and potential launch delays. We propose circumventing launch platform complications by using waypoints in space to park a deep space SmallSat or CubeSat while awaiting the opportunity to enter a trajectory to flyby a suitable target. In our Planetary Science Deep Space SmallSat Studies (PSDS3) project, we investigated scientific goals, waypoint options, potential concept of operations (ConOps) for periodic and new comets, spacecraft bus infrastructure requirements, launch platforms, and mission operations and phases. Our payload would include two low-risk instruments: a visible image (VisCAM) for 5-10 m resolution surface maps; and a highly versatile multispectral Comet CAMera (ComCAM) will measure 1) H2O, CO2, CO, and organics non-thermal fluorescence signatures in the 2-5 μm MWIR, and 2) 7-10 and 8-14 μm thermal (LWIR) emission. This payload would return unique data not obtainable from ground-based telescopes and complement data from Earth-orbiting observatories. Thus, the PrOVE mission would (1) acquire visible surface maps, (2) investigate chemical heterogeneity of a comet nucleus by quantifying volatile species abundance and changes with solar insolation, (3) map the spatial distribution of volatiles and determine any variations, and (4) determine the frequency and distribution of outbursts.

Clark, Pamela S.↗

Overview of Primitive Volatile Explorer (PrOVE) Cubesat or Smallsat Concept

Here we describe the Primitive Object Volatile Explorer (PrOVE), a smallsat mission concept to study the surface structure and volatile inventory of comets in their perihelion passage phase when volatile activity is near peak. CubeSat infrastructure imposes limits on propulsion systems, which are compounded by sensitivity to the spacecraft disposal state from the launch platform and potential launch delays. We propose circumventing launch platform complications by using waypoints in space to park a deep space SmallSat or CubeSat while awaiting the opportunity to enter a trajectory to flyby a suitable target. In our Planetary Science Deep Space SmallSat Studies (PSDS3) project, we investigated scientific goals, waypoint options, potential concept of operations (ConOps) for periodic and new comets, spacecraft bus infrastructure requirements, launch platforms, and mission operations and phases. Our payload would include two low-risk instruments: a visible image (VisCAM) for 5-10 m resolution surface maps; and a highly versatile multispectral Comet CAMera (ComCAM) will measure 1) H2O, CO2, CO, and organics non-thermal fluorescence signatures in the 2-5 µm MWIR, and 2) 7-10 and 8-14 µm thermal (LWIR) emission. This payload would return unique data not obtainable from ground-based telescopes and complement data from Earth-orbiting observatories. Thus, the PrOVE mission would (1) acquire visible surface maps, (2) investigate chemical heterogeneity of a comet nucleus by quantifying volatile species abundance and changes with solar insolation, (3) map the spatial distribution of volatiles and determine any variations, and (4) determine the frequency and distribution of outbursts.

Zucherman, Aaron↗

Models Transport Saharan Dust too Low in the Atmosphere: a Comparison of the MetUM and CAMS Forecasts with Observations

We investigate the dust forecasts from two operational global atmospheric models in comparison with in situ and remote sensing measurements obtained during the AERosol properties – Dust (AER-D) field campaign. Airborne elastic backscatter lidar measurements were performed on board the Facility for Airborne Atmospheric Measurements during August 2015 over the eastern Atlantic, and they permitted us to characterise the dust vertical distribution in detail, offering insights on transport from the Sahara. They were complemented with airborne in situ measurements of dust size distribution and optical properties, as well as datasets from the Cloud–Aerosol Transport System (CATS) spaceborne lidar and the Moderate Resolution Imaging Spectroradiometer (MODIS). We compare the airborne and spaceborne datasets to operational predictions obtained from the Met Office Unified Model (MetUM) and the Copernicus Atmosphere Monitoring Service (CAMS). The dust aerosol optical depth predictions from the models are generally in agreement with the observations but display a low bias. However, the predicted vertical distribution places the dust lower in the atmosphere than highlighted in our observations. This is particularly noticeable for the MetUM, which does not transport coarse dust high enough in the atmosphere or far enough away from the source.We also found that both model forecasts underpredict coarse-mode dust and at times overpredict fine-mode dust, but as they are fine-tuned to represent the observed optical depth, the fine mode is set to compensate for the underestimation of the coarse mode. As aerosol–cloud interactions are dependent on particle numbers rather than on the optical properties, this behaviour is likely to affect their correct representation. This leads us to propose an augmentation of the set of aerosol observations available on a global scale for constraining models, with a better focus on the vertical distribution and on the particle size distribution. Mineral dust is a major component of the climate system; therefore, it is important to work towards improving how models reproduce its properties and transport mechanisms.

Debbie OSullivan↗

Robust high-performance control for robotic manipulators

Model-based and performance-based control techniques are combined for an electrical robotic control system. Thus, two distinct and separate design philosophies were merged into a single control system having a control law formulation including two distinct and separate components, each of which yields a respective signal componet that is combined into a total command signal for the system. Those two separate system components include a feedforward controller and feedback controller. The feedforward controller is model-based and contains any known part of the manipulator dynamics that can be used for on-line control to produce a nominal feedforward component of the system's control signal. The feedback controller is performance-based and consists of a simple adaptive PID controller which generates an adaptive control signal to complement the nomical feedforward signal.

Seraji, Homayoun↗

Characteristics of the GOES I-M Imager and Sounder

The design and the parameters of the improved thermal-imaging and sounding instruments (the Imager and the Sounder) that will be part of the instrument complements of the next-generation Geostationary Operational Environmental Satellite (GOES I-M) are discussed. The new design incorporates many features that enhance instrumental reliability over the previous GOES radiometric instruments, such as independently functioning Sounder and Imager, redundancy, and more reliable position sensors and lubrication methods. Tables are presented which list the instrument parameters of the GOES I-M Imager and Sounder and the performance characteristics of the two instruments.

Ernst, Thomas J.↗

Robust high-performance control for robotic manipulators

Model-based and performance-based control techniques are combined for an electrical robotic control system. Thus, two distinct and separate design philosophies have been merged into a single control system having a control law formulation including two distinct and separate components, each of which yields a respective signal component that is combined into a total command signal for the system. Those two separate system components include a feedforward controller and a feedback controller. The feedforward controller is model-based and contains any known part of the manipulator dynamics that can be used for on-line control to produce a nominal feedforward component of the system's control signal. The feedback controller is performance-based and consists of a simple adaptive PID controller which generates an adaptive control signal to complement the nominal feedforward signal.

Seraji, Homayoun↗

Enumeration and Fluorescence In Situ Hybridization of Microbial Bioburden on Cleanroom Surfaces

Introduction: Microorganisms are everywhere on Earth, even in the cleanest of places. Spacecraft assembly cleanrooms can harbor low levels of living and dead microbial cells (e.g., [1,2]), and cleanroom bioburden can also include organic molecules from industrial sources and in situ biomass. Life detection missions require careful attention to avoid contaminants that can be easily convoluted with analytical targets. We are evaluating epifluorescent microscopy and fluorescence in situ hybridization (FISH) as methods to complement organic contamination detection techniques. Epifluorescent cell counting offers an accurate and cost-effective way to quantify low levels of surface biomass. FISH could allow for the identification of residual organisms, and can be targeted to detect active populations of specific organisms such as bacteria known to resist cleaning procedures. This effort is part of a larger study that is concentrated on characterizing the surface and airborne molecular organic contamination background in Johnson Space Center (JSC) Astromaterials curation laboratories and Goddard Space Flight Center (GSFC) spacecraft assembly rooms, and understanding contaminants in the context of cleaning procedures and residual bioburden. Methods: Samples were collected by swabbing surfaces in ISO 5 and ISO 7 equivalent cleanrooms at JSC. Swabs for FISH were fixed in 4% paraformaldehyde (PFA) for 3 hours and then stored in 1:1 ethanol:PBS, while swabs for cell counting were stored in 4% PFA until analysis to avoid any cell loss during centrifugation that could impact quantification of very low biomass samples. Cell counting was performed with SYBR Gold as in [3], but adapted for very low biomass. FISH was performed as in [4], using DAPI as a counterstain for all DNA-containing cells. Negative controls included wells with no probe applied, to test for natural fluorescence, as well as the nonsense probe NONEUB (reverse complement of EUB338) to evaluate non-specific probe binding. Results and Discussion: Cleanroom surfaces had 102-103 cells cm-2. The extremely low biomass of these samples was challenging for enumeration, and required careful and routine use of “field” and laboratory blanks. FISH was performed with the general archaeal and bacterial probes ARCH915 and EUB338 (EUBMIX, [4]), probe GAMBET ([4]), and PSE227, which targets the genus Pseudomonas [5]). The latter two probes were selected because Pseudomonas spp. and other Gammaproteobacteria have not been isolated from cleanroom surfaces but do appear frequently in rRNA gene libraries from these surfaces. While some active bacteria were identified (Fig. 1c), most cells detectable by DAPI did not have a strong or any fluorescent signal (e.g., Fig. 1d), indicating that the vast majority of cells are dead or inactive. This suggests that cleaning protocols are effective at inactivating microbial contaminants, but that dead or inactive cells can remain on surfaces. Cells were often clumped in a weakly autofluorescent matrix, possibly biofilm material (Fig. 1c,d). We also observed other particulate material that was collected by the swabs, including apparent textile fibers (Fig. 1b). Our results are consistent with other studies that show that the bioburden present in clean rooms includes active, dormant, and dead cells. We will discuss how FISH and epifluorescent cell counting could be applied in planetary protection protocols, including the advantages and disadvantages of FISH and cell counting for routine use, as well as different possible applications for more specialized FISH procedures. References: [1] Moissl-Eichinger et al. (2015) Sci Rep, 5, 9156 [2] Hendrickson et al. (2021) Microbiome, 9, 238 [3] Jones et al. (2017) Appl Environ Microbiol, 83, e00909-17 [4] Jones et al. (2015) Appl Environ Microbiol, 81, 1242-1250. [5] Watt et al. (2006) Environ Microbiol, 8, 871-884

C J Huff↗

Turbulent Flow Field Measurements of Separate Flow Round and Chevron Nozzles with Pylon Interaction Using Particle Image Velocimetry

Particle Image Velocimetry (PIV) measurements for six separate flow bypass ratio five nozzle configurations have recently been obtained in the NASA Langley Jet Noise Laboratory. The six configurations include a baseline configuration with round core and fan nozzles, an eight-chevron core nozzle at two different clocking positions, and repeats of these configurations with a pylon included. One run condition representative of takeoff was investigated for all cases with the core nozzle pressure ratio set to 1.56 and the total temperature to 828 K. The fan nozzle pressure ratio was set to 1.75 with a total temperature of 350 K, and the freestream Mach number was M = 0.28. The unsteady flow field measurements provided by PIV complement recent computational, acoustic, and mean flow field studies performed at NASA Langley for the same nozzle configurations and run condition. The PIV baseline configuration measurements show good agreement with mean flow field data as well as existing PIV data acquired at NASA Glenn. Nonetheless, the baseline configuration turbulence profile indicates an asymmetric flow field, despite careful attention to concentricity. The presence of the pylon increases the upper shear layer turbulence levels while simultaneously decreasing the turbulence levels in the lower shear layer. In addition, a slightly shorter potential core length is observed with the addition of the pylon. Finally, comparisons of computational results with PIV measurements are favorable for mean flow, slightly over-predicted for Reynolds shear stress, and underpredicted for Reynolds normal stress components.

Doty, Michael J.↗

Merging of the Case 2 Regional Coast Colour and Maximum‑Peak Height Chlorophyll‑a Algorithms: Validation and Demonstration of Satellite‑derived Retrievals Across US Lakes

Water quality monitoring is relevant for protecting the designated, or beneficial uses, of water such as drinking, aquatic life, recreation, irrigation, and food supply that support the economy, human well-being, and aquatic ecosystem health. Managing finite water resources to support these designated uses requires information on water quality so that managers can make sustainable decisions. Chlorophyll-a (chl-a, µg L−1) concentration can serve as a proxy for phytoplankton biomass and may be used as an indicator of increased anthropogenic nutrient stress. Satellite remote sensing may present a complement to in situ measures for assessments of water quality through the retrieval of chl-a with in-water algorithms. Validation of chl-a algorithms across US lakes improves algorithm maturity relevant for monitoring applications. This study compares performance of the Case 2 Regional Coast Colour (C2RCC) chl-a retrieval algorithm, a revised version of the Maximum-Peak Height (MPH(P)) algorithm, and three scenarios merging these two approaches. Satellite data were retrieved from the MEdium Resolution Imaging Spectrometer (MERIS) and the Ocean and Land Colour Instrument (OLCI), while field observations were obtained from 181 lakes matched with U.S. Water Quality Portal chl-a data. The best performance based on mean absolute multiplicative error (MAEmult) was demonstrated by the merged algorithm referred to as C15−M10 (MAEmult = 1.8, biasmult = 0.97, n = 836). In the C15−M10 algorithm, the MPH(P) chl-a value was retained if it was > 10 µg L−1; if the MPH(P) value was ≤ 10 µg L−1, the C2RCC value was selected, as long as that value was < 15 µg L−1. Time-series and lake-wide gradients compared against independent assessments from Lake Champlain and long-term ecological research stations in Wisconsin were used as complementary examples supporting water quality reporting requirements. Trophic state assessments for Wisconsin lakes provided examples in support of inland water quality monitoring applications. This study presents and assesses merged adaptations of chl-a algorithms previously reported independently. Additionally, it contributes to the transition of chl-a algorithm maturity by quantifying error statistics for a number of locations and times.

Satellite↗

Proceedings from the 1998 Occupational Health Conference: Benchmarking for Excellence

The theme of the 1998 NASA Occupational Health Conference was "Benchmarking for Excellence." Conference participants included NASA and contractor Occupational Health professionals, as well as speakers from NASA, other Federal agencies and private companies. Addressing the Conference theme, speakers described new concepts and techniques for corporate benchmarking. They also identified practices used by NASA, other Federal agencies, and by award winning programs in private industry. A two-part Professional Development Course on workplace toxicology and indoor air quality was conducted a day before the Conference. A program manager with the International Space Station Office provided an update on station activities and an expert delivered practical advice on both oral and written communications. A keynote address on the medical aspects of space walking by a retired NASA astronaut highlighted the Conference. Discipline breakout sessions, poster presentations, and a KSC tour complemented the Conference agenda.

G Wyckliffe Hoffler↗

Electrolytes for Low-Temperature Operation of Li-CFx Cells

A report describes a study of electrolyte compositions selected as candidates for improving the low-temperature performances of primary electrochemical cells that contain lithium anodes and fluorinated carbonaceous (CFx) cathodes. This study complements the developments reported in Additive for Low-Temperature Operation of Li-(CF)n Cells (NPO- 43579) and Li/CFx Cells Optimized for Low-Temperature Operation (NPO- 43585), which appear elsewhere in this issue of NASA Tech Briefs. Similar to lithium-based electrolytes described in several previous NASA Tech Briefs articles, each of these electrolytes consisted of a lithium salt dissolved in a nonaqueous solvent mixture. Each such mixture consisted of two or more of the following ingredients: propylene carbonate (PC); 1,2-dimethoxyethane (DME); trifluoropropylene carbonate; bis(2,2,2-trifluoroethyl) ether; diethyl carbonate; dimethyl carbonate; and ethyl methyl carbonate. The report describes the physical and chemical principles underlying the selection of the compositions (which were not optimized) and presents results of preliminary tests made to determine effects of the compositions upon the low-temperature capabilities of Li-CFx cells, relative to a baseline composition of LiBF4 at a concentration of 1.0 M in a solvent comprising equal volume parts of PC and DME.

Smart, Marshall C.↗