Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Dynamical analysis of innovative core designs facing unprotected transients with the MAT5 DYN code

Since 2007, advanced Sodium-cooled Fast Reactors (SFR) are investigated by CEA, AREVA and EDF in the framework of a joint French collaboration. A prototype called ASTRID, sets out to demonstrate progress made in SFR technology, is due to operate in the years 2020's. The modeling of unprotected transients by computer codes is one of the key safety issues in the design approach to such SFR systems. For that purpose, the activity on CATHARE, which is the reference code for the transient analysis of ASTRID, has been strengthened during last years by CEA. In the meantime, EDF has developed a simplified and multi-channel code, named MAT5 DYN, to analyze and validate innovative core designs facing protected and unprotected transients. First, the paper consists in a description of MAT5 DYN: a code based on the existing code MAT4 DYN including major improvements on geometry description and physical modeling. Second, two core designs based on the CFV core design developed at CEA are presented. Then, the dynamic response of those heterogeneous cores is analyzed during unprotected loss of flow (ULOF) transient and unprotected transient of power (UTOP). The results highlight the importance of the low void core effect specific to the CFV design. Such an effect, when combined with a sufficient primary pump halving time and an optimized cooling group scheme, allows to delay (or, possibly, avoid) the sodium boiling onset during ULOF accidents. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capabilities development for transient testing of advanced nuclear fuels at TREAT

The TREAT facility is a unique capability at the Idaho National Laboratory currently being prepared for resumption of nuclear transient testing. TREAT is an air-cooled reactor where the driver core is made up of urania dispersed in graphite blocks and encapsulated in zirconium alloy cans. In addition to the reactor itself, the foundation for TREAT's capabilities will also include a suite of irradiation vehicles and supporting infrastructure to provide the desired specimen boundary conditions while supporting a variety of instrumentation needs. Although TREAT historically supported all kinds of nuclear fuels, including LWR's, SFR's, space nuclear propulsion, research reactor plate-type fuels, and even fuels for use in the driver core of other transient test reactors, the majority of TREAT's more-recent experiment programs revolved around SFR's and sodium-environment test capsules and loops. MK-series loop experiment-specific test trains could be outfitted with a variety of instruments to monitor test and specimen conditions while the fast neutron hodoscope collected information about fuel movement before, during, and after transient excursions. The SERTTA (Static Environment Rodlet Transient Test Apparatuses) devices will be general purpose vehicles capable of providing inert gas, water (up to PWR conditions), steam, or perhaps even molten sodium environments within vessel-like capsules. The Multi-SERTTA vehicle design is particularly novel as it makes use of the full active core length in TREAT to test four small rodlets (∼12 cm length), each within its own hermetic boundary, it will be capable of housing pre-irradiated fuel specimens. Additional modules and adaptations of Multi-SERTTA will enable rapid loop pressure blowdown to simulate LOCA conditions. The Super-SERTTA, akin to the Multi-SERTTA will offer more possibilities for simulating transient phenomena.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Monte Carlo Transient Analysis with Thermal-Hydraulic Feedback by McCARD/CUPID

The reactor core transient analysis requires neutronics calculations with the thermal-hydraulic (TH) feedback. Recently the dynamic Monte Carlo (DMC) neutron transport algorithm controlling delayed neutron precursors was developed and successfully applied for core transient problems with help of a sub-channel code. In the Seoul National University Monte Carlo (MC) code, McCARD, a DMC scheme for the core transient analysis has been implemented by coupling with a computational fluid dynamics code, CUPID using the TCP/IP socket communication. In the McCARD/CUPID transient calculations, temperature-dependent cross sections are produced by a built-in on-the-fly Doppler broadening (OTF DB) module. This paper presents McCARD/CUPID transient analysis results for a triangular unit cell problem in the IAEA coordinated research project (CRP) benchmark on the high temperature gas cooled reactor (HTGR) uncertainty analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty and Sensitivity Analysis of TREAT Transient Test no. 15

The U.S. Department of Energy (DOE) is preparing for the resumption of transient testing using the Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory (INL). In order to support the analysis of TREAT operation and experiment planning, the MAMMOTH reactor physics team has recently begun development of uncertainty and sensitivity analysis for the TREAT core simulated via MAMMOTH. MAMMOTH is a high-fidelity three-dimensional transient multi-physics code developed at INL under the DOE-NE Advanced Modeling and Simulation program (NEAMS). This research is part of the development presenting some initial uncertainty and sensitivity analysis of TREAT Transient Test no. 15. In this summary, we employ the Sobol sampling strategy implemented in RAVEN to efficiently perform the sensitivity and uncertainty analysis. The idea is using Sobol functional decomposition with generalized polynomial chaos (gPC) expansions to estimate the responses of interest. The gPC coefficients are then computed via the sparse grid spectral projection method. In addition, this strategy includes evaluation of the second or higher order sensitivity indices, allowing the study of interactions between several input variables. The principal focus of this analysis is to quantify the uncertainties in the total power and maximum fuel temperatures with respect to uncertainties in the initial transient conditions, such as rated power, fuel temperature, graphite fuel density and control rod boron concentration. In addition, both the first order and second order time-dependent sensitivity indices are computed and analyzed. The results show that the interactions between initial control rod boron concentration and the rated power will contribute at most 1% to the total uncertainty of the power peak.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a TRISO assessment case for BISON based on transient experiments in the NSRR

The tristructural isotropic (TRISO) fuel assessment and validation database currently available in BISON is based mainly on steady-state irradiation and high-temperature furnace testing. Transient assessment cases are needed to support ongoing U.S. industry efforts to design and deploy commercial reactors that utilize TRISO fuels. Most available historical transient tests involving TRISO fuels were characterized by power densities, temperatures, and energy depositions that were highly conservative with respect to typical high-temperature gas-cooled reactor (HTGR) accident conditions. Nonetheless, assessment of BISON's predictive capabilities, adaptation of material properties toward high-temperature and high-particle-power regimes, and development of a systematic approach to validating BISON for TRISO transient applications now motivate the modeling of historical transient tests. This work describes the development of 1-D thermal models of transient experiments conducted at the Nuclear Safety Research Reactor (NSRR) in Japan, with BISON predictions of energy deposition, UO2 melting onset, and molten volume fractions being compared against experimental measurements. Melting is accounted for by defining an effective specific heat capacity for UO2—one that leverages the material's heat of melting. BISON's predictions of energy deposition and molten volume fraction are in good agreement with the experimental data from the low-energy-deposition tests; however, BISON tends to overpredict melting at higher energy depositions. Though overly conservative compared to the operating conditions expected for near-term TRISO-fueled reactor applications, these simulations effectively exercise BISON TRISO models over a wider range of conditions than those encompassed by the existing assessment database. Potential contributors to the observed discrepancies are noted and additional future developments proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discovery of an Unusual Optical Transient with the Hubble Space Telescope

We present observations of SCP 06F6, an unusual optical transient discovered during the Hubble Space Telescope Cluster Supernova Survey. The transient brightened over a period of ~;;100 days, reached a peak magnitude of ~;;21.0 in both i_775 and z_850, and then declined over a similar timescale. There is no host galaxy or progenitor star detected at the location of the transient to a 3 sigma upper limit of i_775 = 26.4 and z_850 = 26.1, giving a corresponding lower limit on the flux increase of a factor of ~;;120. Multiple spectra show five broad absorption bands between 4100 AA and 6500 AA and a mostly featureless continuum longward of 6500 AA. The shape of the lightcurve is inconsistent with microlensing. The transient's spectrum, in addition to being inconsistent with all known supernova types, is not matched to any spectrum in the Sloan Digital Sky Survey (SDSS) database. We suggest that the transient may be one of a new class.

79 ASTRONOMY AND ASTROPHYSICS↗

Transient current induced in thin film diamonds by swift heavy ions

Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5 + and 45 MeV Si 7 + ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

36 MATERIALS SCIENCE↗

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concurrent Transient Activation of Wnt/{beta}-Catenin Pathway Prevents Radiation Damage to Salivary Glands

Purpose: Many head and neck cancer survivors treated with radiotherapy suffer from permanent impairment of their salivary gland function, for which few effective prevention or treatment options are available. This study explored the potential of transient activation of Wnt/{beta}-catenin signaling in preventing radiation damage to salivary glands in a preclinical model. Methods and Materials: Wnt reporter transgenic mice were exposed to 15 Gy single-dose radiation in the head and neck area to evaluate the effects of radiation on Wnt activity in salivary glands. Transient Wnt1 overexpression in basal epithelia was induced in inducible Wnt1 transgenic mice before together with, after, or without local radiation, and then saliva flow rate, histology, apoptosis, proliferation, stem cell activity, and mRNA expression were evaluated. Results: Radiation damage did not significantly affect activity of Wnt/{beta}-catenin pathway as physical damage did. Transient expression of Wnt1 in basal epithelia significantly activated the Wnt/{beta}-catenin pathway in submandibular glands of male mice but not in those of females. Concurrent transient activation of the Wnt pathway prevented chronic salivary gland dysfunction following radiation by suppressing apoptosis and preserving functional salivary stem/progenitor cells. In contrast, Wnt activation 3 days before or after irradiation did not show significant beneficial effects, mainly due to failure to inhibit acute apoptosis after radiation. Excessive Wnt activation before radiation failed to inhibit apoptosis, likely due to extensive induction of mitosis and up-regulation of proapoptosis gene PUMA while that after radiation might miss the critical treatment window. Conclusion: These results suggest that concurrent transient activation of the Wnt/{beta}-catenin pathway could prevent radiation-induced salivary gland dysfunction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-burnup fuel stress analysis prior to and during a LOCA transient

High-burnup fuel fragmentation and pulverization have been experimentally observed during simulated loss-of-coolant accident (LOCA) transient testing of high-burnup (>62 GWd/tU) nuclear fuel. The cause of this phenomenon is generally accepted to be the formation of stresses arising from the off-normal conditions. However, the primary mechanism(s) contributing to the stress formation is/are still being debated. Leading hypotheses suggest that the concurrence of fission gas bubbles and high burnup structure on the pellet periphery (i.e., the rim) leave the fuel susceptible to pulverization. Other hypotheses suggest that pulverization is artificially inflated during externally heated tests that do not reproduce prototypic fuel stresses and radial temperature profiles as the fuel transitions from full-power nuclear heating to decay heating. This work performs finite element analyses of fuel pellet temperatures and macroscopic stresses prior to and during a LOCA transient to identify (1) operating conditions that may exacerbate the fuel pellet stress state, (2) differences in predicted stresses with nuclear vs. furnace heating, and (3) how fuel cracking impacts the subsequent stress state in the pellet fragments. Analyses predict that macroscopic transient fuel stresses resulting from constrained thermal expansion will remain below the fracture stress of fresh UO 2 once the fragment size reaches ~4 mm or less. Calculated fuel stresses from simulated LOCA tests performed with representative nuclear vs. electrical heating rates are shown to be equal within 5% and essentially unchanged for all times after the first 27 seconds of the transients. Because the fuel stresses do not change once the temperature profile becomes uniform, macroscopic transient stresses would be no different than those following a normal shutdown. Because pulverization of high burnup fuel does not occur prior to a LOCA test, pulverization of high burnup UO 2 cannot be initiated by differential thermal stresses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Failure analysis of nuclear transient-tested UN tristructural isotropic fuel particles in a 3D printed SiC matrix

Fully ceramic microencapsulated fuel elements containing UN tristructural isotropic (TRISO) fuel particles within a 3D printed SiC matrix were subjected to transient testing with varying energy depositions. Detailed post-irradiation examinations were performed, including leaching in hot HNO3 and post-leaching X-ray computed tomography, to quantify the percentage of failed TRISO particles and crack propagation within the particles and surrounding fuel matrix. In parallel, detailed finite element analyses were performed for comparison with experimental findings and to better evaluate transient failure modes. The lowest transient energy deposition—which still exceeded bounding values for high-temperature gas-cooled reactor applications—resulted in no detectable TRISO particle failures or matrix cracking, which was consistent with the simulations. Simulations of the higher-energy transients for which significant TRISO particle failure was expected were generally able to reproduce the transient temperatures and matrix cracking. Thus, the TRISO particle failures were explained based on the effects of local SiC matrix thickness and porosity. Results generally confirmed the high strength of the additively manufactured SiC matrix but also affirmed the need for a modified UN TRISO architecture to prevent SiC matrix cracks from propagating through TRISO layers. This unique failure mode has not historically been considered for TRISO fuels contained in weaker graphite matrices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interpretation of inverted photocurrent transients in organic lead halide perovskite solar cells: proof of the field screening by mobile ions and determination of the space charge layer widths

In Methyl Ammonium Lead Iodide (MAPI) perovskite solar cells, screening of the built-in field by mobile ions has been proposed as part of the cause of the large hysteresis observed in the current/voltage scans in many cells. Here, we show that photocurrent transients measured immediately (e.g. 100 μs) after a voltage step can provide direct evidence that this field screening exists. Just after a step to forward bias, the photocurrent transients are reversed in sign (i.e. inverted), and the magnitude of the inverted transients can be used to find an upper bound on the width of the space charge layers adjacent to the electrodes. This in turn provides a lower bound on the mobile charge concentration, which we find to be ≳1 x 10 17 cm -3 . Using a new photocurrent transient experiment, we show that the space charge layer thickness remains approximately constant as a function of bias, as expected for mobile ions in a solid electrolyte. We also discuss additional characteristics of the inverted photocurrent transients that imply either an unusually stable deep trapping, or a photo effect on the mobile ion conductivity.

14 SOLAR ENERGY↗

Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient light absorption induced in glassby femtosecond laser pulses

The dynamics of the transient light absorption induced in K8 optical glass by filamented femtosecond laser pulses have been studied using time-resolved transmitted-light microscopy at wavelengths from 450 to 700 nm. The transient absorption measured as a function of probe beam wavelength is compared to that predicted by the Drude plasma model. We conclude that, just 450 fs after a pump pulse, the transient absorption is dominated by transient electronic states, presumably, self-trapped excitons, with an excitation energy of 2.6 - 2.7 eV. These states are filled with free-carriers from a long-lived plasma, which acts as a 'carrier reservoir'. The relaxation of transient absorption has two components. The slow component, with {tau}{sub 1} {approx} 17-17.5 ps, is governed by the plasma thermalisation time, whereas the second, with {tau}{sub 1} >> 300 ps, is determined by the plasma lifetime. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE ALLEN TELESCOPE ARRAY TWENTY-CENTIMETER SURVEY-A 690 DEG{sup 2}, 12 EPOCH RADIO DATA SET. I. CATALOG AND LONG-DURATION TRANSIENT STATISTICS

We present the Allen Telescope Array Twenty-centimeter Survey (ATATS), a multi-epoch (12 visits), 690 deg{sup 2} radio image and catalog at 1.4 GHz. The survey is designed to detect rare, very bright transients as well as to verify the capabilities of the ATA to form large mosaics. The combined image using data from all 12 ATATS epochs has rms noise {sigma} = 3.94 mJy beam{sup -1} and dynamic range 180, with a circular beam of 150'' FWHM. It contains 4408 sources to a limiting sensitivity of 5{sigma} = 20 mJy beam{sup -1}. We compare the catalog generated from this 12 epoch combined image to the NRAO VLA Sky Survey (NVSS), a legacy survey at the same frequency, and find that we can measure source positions to better than {approx}20''. For sources above the ATATS completeness limit, the median flux density is 97% of the median value for matched NVSS sources, indicative of an accurate overall flux calibration. We examine the effects of source confusion due to the effects of differing resolution between ATATS and NVSS on our ability to compare flux densities. We detect no transients at flux densities greater than 40 mJy in comparison with NVSS and place a 2{sigma} upper limit of 0.004 deg{sup -2} on the transient rate for such sources. These results suggest that the {approx}>1 Jy transients reported by Matsumara et al. may not be true transients, but rather variable sources at their flux density threshold.

79 ASTRONOMY AND ASTROPHYSICS↗

THE ROLE OF STRUCTURED MAGNETIC FIELDS ON CONSTRAINING PROPERTIES OF TRANSIENT SOURCES OF ULTRA-HIGH-ENERGY COSMIC RAYS

We study how the properties of transient sources of ultra-high-energy cosmic rays (UHECRs) can be accessed by exploiting UHECR experiments, taking into account the propagation of UHECRs in magnetic structures which the sources are embedded in, i.e., clusters of galaxies and filamentary structures. Adopting simplified analytical models, we demonstrate that the structured extragalactic magnetic fields (EGMFs) play crucial roles in unveiling the properties of the transient sources. These EGMFs unavoidably cause significant delay in the arrival time of UHECRs as well as the Galactic magnetic field, even if the strength of magnetic fields in voids is zero. Then, we show that, given good knowledge on the structured EGMFs, UHECR observations with high statistics above 10{sup 20} eV allow us to constrain the generation rate of transient UHECR sources and their energy input per burst, which can be compared with the rates and energy release of known astrophysical phenomena. We also demonstrate that identifying the energy dependence of the apparent number density of UHECR sources at the highest energies is crucial to such transient sources. Future UHECR experiments with extremely large exposure are required to reveal the nature of transient UHECR sources.

79 ASTRONOMY AND ASTROPHYSICS↗

A TRANSIENT SUB-EDDINGTON BLACK HOLE X-RAY BINARY CANDIDATE IN THE DUST LANES OF CENTAURUS A

We report the discovery of a bright X-ray transient CXOU J132527.6-430023 in the nearby early-type galaxy NGC 5128. The source was first detected over the course of five Chandra observations in 2007, reaching an unabsorbed outburst luminosity of (1-2) Multiplication-Sign 10{sup 38} erg s{sup -1} in the 0.5-7.0 keV band before returning to quiescence. Such luminosities are possible for both stellar-mass black hole and neutron star (NS) X-ray binary transients. Here, we attempt to characterize the nature of the compact object. No counterpart has been detected in the optical or radio sky, but the proximity of the source to the dust lanes allows for the possibility of an obscured companion. The brightness of the source after a >100-fold increase in X-ray flux makes it either the first confirmed transient non-ultraluminous X-ray black hole system in outburst to be subject to detailed spectral modeling outside the Local Group, or a bright (>10{sup 38} erg s{sup -1}) transient NS X-ray binary, which are very rare. Such a large increase in flux would appear to lend weight to the view that this is a black hole transient. X-ray spectral fitting of an absorbed power law yielded unphysical photon indices, while the parameters of the best-fit absorbed disk blackbody model are typical of an accreting {approx}10 M{sub Sun} black hole in the thermally dominant state.

79 ASTRONOMY AND ASTROPHYSICS↗

Extragalactic high-energy transients: Event rate densities and luminosity functions

Several types of extragalactic high-energy transients have been discovered, which include high-luminosity and low-luminosity long-duration gamma-ray bursts (GRBs), short-duration GRBs, supernova shock breakouts (SBOs), and tidal disruption events (TDEs) without or with an associated relativistic jet. In this paper, we apply a unified method to systematically study the redshift-dependent event rate densities and the global luminosity functions (GLFs; ignoring redshift evolution) of these transients. We introduce some empirical formulae for the redshift-dependent event rate densities for different types of transients and derive the local specific event rate density, which also represents its GLF. Long GRBs (LGRBs) have a large enough sample to reveal features in the GLF, which is best charaterized as a triple power law (PL). All the other transients are consistent with having a single-power-law (SPL) LF. The total event rate density depends on the minimum luminosity, and we obtain the following values in units of Gpc{sup −3} yr{sup −1}: 0.8{sub −0.1}{sup +0.1} for high-luminosity LGRBs above 10{sup 50} erg s{sup −1}; 164{sub −65}{sup +98} for low-luminosity LGRBs above 5 × 10{sup 46} erg s{sup −1}; 1.3{sub −0.3}{sup +0.4}, 1.2{sub −0.3}{sup +0.4}, and 3.3{sub −0.8}{sup +1.0} above 10{sup 50} erg s{sup −1} for short GRBs with three different merger delay models (Gaussian, lognormal, and PL); 1.9{sub −1.2}{sup +2.4}×10{sup 4} above 10{sup 44} erg s{sup −1} for SBOs, 4.8{sub −2.1}{sup +3.2}×10{sup 2} for normal TDEs above 10{sup 44} erg s{sup −1}; and 0.03{sub −0.02}{sup +0.04} above 10{sup 48} erg s{sup −1} for TDE jets as discovered by Swift. Intriguingly, the GLFs of different kinds of transients, which cover over 12 orders of magnitude, are consistent with an SPL with an index of −1.6.

79 ASTRONOMY AND ASTROPHYSICS↗