Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Data-driven delta-generalized labeled multi-bernoulli tracker

A system and method for tracking a plurality of objects. Unlabeled measurement data identifying a plurality of targets corresponding to the plurality of objects is received. A multi-target likelihood function is generated using a persistent target density, a birth target density, and a clutter density. The multi-target likelihood function is used to associate persistent targets with the unlabeled measurement data to update persistent tracks and to initiate a new track for each target in the plurality of targets in the measurement data that is not associated with a persistent target.

LeGrand, Keith Allen↗

Solar tracker control system and method

A pneumatic control unit configured to inflate a first and second set of bellows with fluid from a pneumatic fluid source via a pneumatic circuit, the first and second set of bellows associated with one or more pneumatic actuators. The pneumatic control unit determines a target configuration of the actuators based on a determined current position of the sun; determines a current configuration of the actuators; determines a difference between the determined current configuration and target configuration of the actuators; determines that the difference between current configuration and the target configuration of the actuators is outside of a tolerance range; and actuates the actuators toward the determined target configuration by at least one of inflating the first or second set of bellows with fluid from the pneumatic fluid source via the pneumatic circuit.

Betts, Kenneth H.↗

A prototype scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

A prototype scintillating-fibre detector system has been developed at the University of Glasgow in collaboration with the UK National Nuclear Laboratory (NNL) for the nondestructive assay of UK legacy nuclear waste containers. This system consists of two tracking modules above, and two below, the container under interrogation. Each module consists of two orthogonal planes of 2 mm-pitch fibres yielding one space point. Per plane, 128 fibres are read out by a single Hamamatsu H8500 64-channel MAPMT with two fibres multiplexed onto each pixel. A dedicated mapping scheme has been developed to avoid space point ambiguities and retain the high spatial resolution provided by the fibres. The configuration allows the reconstruction of the incoming and scattered muon trajectories, thus enabling the container content, with respect to atomic number Z, to be determined. Results are shown from experimental data collected for high-Z objects within an air matrix and, for the first time, within a shielded, concrete-filled container. These reconstructed images show clear discrimination between the low, medium and high-Z materials present, with dimensions and positions determined with sub-centimetre precision. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS Outer Tracker Module QA

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Hobbeheydar, Samuel [Carnegie Mellon U. (main); Fe↗

Fermilab Italian Student Program (Final Report)

I participated to the 2019 Fermilab Italian Student Program under the supervision of Anadi Canepa and Lorenzo Uplegger. I worked with the Fermilab research group that is involved with the R&D of the CMS Outer Tracker. The Compact Muon Solenoid (CMS) is a a general-purpose detector located at the Large Hadron Collider (LHC), the world's most powerful particle accelerator. In the next years LHC will undergo the High-Luminosity LHC upgrade, which will bring its luminosity from 1 × 10 34 cm -2 s -1 to 1.5 × 10 34 cm -2 s -1 . This increase in luminosity will require an upgrade of CMS as well, in order to comply with the augmented rate of particles which will cross the detector. The CMS tracker is a detector, composed of various modules made of silicon pixel trackers and silicon strip trackers, whose aim is to reconstruct the trajectories of the particles produced by the collisions in LHC. The tracker is ideally divided in Inner Tracker and Outer Tracker. The HL-LHC upgrade put important challenges in the designing of the tracker. It will have to withstand the irradiation of a large fluence of particles, without suffering a too severe deterioration of its performance. In addition to this, in order to comply with the increased rate of events that CMS will need to detect, the tracker will be exploited for triggering at the fully hardware Level 1 Trigger, in contrast to the current tracker, whose data are only used for the software High-Level Trigger. This feature is managed by the "stub logic", which will be explained in chapter 2. During the months of August and September at Fermilab I carried out the data analysis of three test beam runs performed in the last two years on the 2S Outer Tracker Minimules. The 2S Minimoule consists of two silicon strip trackers placed one upon the other with the strips kept parallel.

43 PARTICLE ACCELERATORS↗

A Study of Muon Ionization Cooling at MICE

A Neutrino Factory based on a high-energy muon storage-ring is proposed to study neutrino oscillation with high precision. An emittance reduction of muon beam by ionization cooling, which has never been demonstrated in practice, is one of the critical issues for Neutrino Factory. The international Muon Ionisation Cooling Experiment (MICE) is the first experiment to verify an effect of the ionization cooling with muons. MICE will measure a change in transverse emittance of approximately 10% with a precision of ±0.1%. In order to meet the requirements, muon trackers based on 350 μm diameter scintillating fibers have been proposed. The construction of such trackers is a very challenging task and some innovative techniques are needed to realize, since there have been no trackers made with such a small diameter of scintillating fibers in the world. Upstream and downstream SciFi trackers have been successfully constructed with the international collaboration of UK, US and Japan by 2008. Both of the trackers have been tested with cosmic-rays at the RAL by 2009, at which high tracking efficiencies more than 90% are measured for both trackers. It is also confirmed that by collecting the misalignments found in both of the trackers, the requirements for the emittance measurement is met.

43 PARTICLE ACCELERATORS↗

Searches for long-lived charged particles in pp collisions at $\sqrt{s}$ = 7 and 8 TeV

Results of searches for heavy stable charged particles produced in pp collisions at $\sqrt{s}$ =7 and 8 TeV are presented corresponding to an integrated luminosity of 5.0 fb -1 and 18.8 fb -1 , respectively. Data collected with the CMS detector are used to study the momentum, energy deposition, and time-of-flight of signal candidates. Leptons with an electric charge between e/3 and 8e, as well as bound states that can undergo charge exchange with the detector material, are studied. Analysis results are presented for various combinations of signatures in the inner tracker only, inner tracker and muon detector, and muon detector only. Detector signatures utilized are long time-of-flight to the outer muon system and anomalously high (or low) energy deposition in the inner tracker. The data are consistent with the expected background, and upper limits are set on the production cross section of long-lived gluinos, scalar top quarks, and scalar τ leptons, as well as pair produced long-lived leptons. Corresponding lower mass limits, ranging up to 1322 GeV/c (2) for gluinos, are the most stringent to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Large Area Telescope on the Fermi Gamma-ray Space Telescope Mission

The Large Area Telescope (Fermi/LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view (FoV), high-energy {gamma}-ray telescope, covering the energy range from below 20 MeV to more than 300 GeV. The LAT was built by an international collaboration with contributions from space agencies, high-energy particle physics institutes, and universities in France, Italy, Japan, Sweden, and the United States. This paper describes the LAT, its preflight expected performance, and summarizes the key science objectives that will be addressed. On-orbit performance will be presented in detail in a subsequent paper. The LAT is a pair-conversion telescope with a precision tracker and calorimeter, each consisting of a 4 x 4 array of 16 modules, a segmented anticoincidence detector that covers the tracker array, and a programmable trigger and data acquisition system. Each tracker module has a vertical stack of 18 (x, y) tracking planes, including two layers (x and y) of single-sided silicon strip detectors and high-Z converter material (tungsten) per tray. Every calorimeter module has 96 CsI(Tl) crystals, arranged in an eight-layer hodoscopic configuration with a total depth of 8.6 radiation lengths, giving both longitudinal and transverse information about the energy deposition pattern. The calorimeter's depth and segmentation enable the high-energy reach of the LAT and contribute significantly to background rejection. The aspect ratio of the tracker (height/width) is 0.4, allowing a large FoV (2.4 sr) and ensuring that most pair-conversion showers initiated in the tracker will pass into the calorimeter for energy measurement. Data obtained with the LAT are intended to (1) permit rapid notification of high-energy {gamma}-ray bursts and transients and facilitate monitoring of variable sources, (2) yield an extensive catalog of several thousand high-energy sources obtained from an all-sky survey, (3) measure spectra from 20 MeV to more than 50 GeV for several hundred sources, (4) localize point sources to 0.3-2 arcmin, (5) map and obtain spectra of extended sources such as SNRs, molecular clouds, and nearby galaxies, (6) measure the diffuse isotropic {gamma}-ray background up to TeV energies, and (7) explore the discovery space for dark matter.

Astrophysics,ASTRO↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

TracKlinic: Diagnosis of Challenge Factors in Visual Tracking

Generic visual object tracking is difficult due to many challenge factors (e.g., occlusion, blur, etc.). Each of these factors may cause serious problems for a tracker, and when they work together can make things even more complicated. Despite a great amount of efforts devoted to understanding the behavior of trackers, reliable and quantifiable ways for studying the per factor tracking behavior remain barely available. Addressing this issue, in this paper we contribute to the community a tracking diagnosis toolkit, TracKlinic, for diagnosis of challenge factors of tracking algorithms. TracKlinic consists of two novel components focusing on the data and analysis aspects, respectively. For the data component, we carefully prepare a set of 2,390 annotated videos, each involving one and only one major challenge factor. When analyzing an algorithm for a specific challenge factor, such one-factor-per-sequence rule greatly inhibits the disturbance from other factors and consequently leads to more faithful analysis. For the analysis component, given the tracking results on all sequences, it investigates the behavior of the tracker under each individual factor and generates the report automatically. With TracKlinic, a thorough study is conducted on ten state-of-the-art trackers on nine challenge factors (including two compound ones). The results suggest that, heavy shape variation and occlusion are the two most challenging factors faced by most trackers. Besides, out-of-view, though does not happen frequently, is often fatal. By sharing TracKlinic1, we expect to make it much easier for diagnosing tracking algorithms, and to thus facilitate developing better ones.

97 MATHEMATICS AND COMPUTING↗

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗