Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Apparatus for real-time size-distributed measurement of aerosol mass concentration

An impactor, system and method for performing real-time measurements of particles in aerosol gases. The impactor comprises a plurality of cascading stages having impaction plates, mass-measurement mechanisms retained on the impaction plates, and a nozzle plate. A signal line associated with each of the plurality of cascading stages is configured to relay signals from the mass-measurement mechanism of the associated stage to a computer-based system configured to receive the transmitted signals from the signal lines, and to correlate changes in the resonant frequencies to particle concentrations in real time.

Chen, Modi↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Real-Time Longitudinal Profile Measurement of Operational H⁻ Beam at the SNS Linac Using a Laser Comb

We demonstrate a novel technique to measure the longitudinal profile of an operational hydrogen ion (H⁻) beam in a non intrusive, real-time fashion. The measurement is conducted based on the photo-ionization of the ion beam with a phase modulated laser comb pico-second laser pulses with controllable temporal structure. The measurement technique has been applied to a 1-GeV, 1.4-MW H⁻ beam at the Spallation Neutron Source (SNS) high energy beam transport (HEBT). A stroboscopic photo-graph of H⁻ beamμbunch can be obtained by using a phase modulated laser comb. The entire measurement takes only 700 us.

Liu, Yun↗

Accurate Ultrasonic Thickness Measurement for Arbitrary Time-Variant Thermal Profile

Ultrasonic thickness measurement of mechanical structures is one of the most popular and commonly used nondestructive methods for various kinds of process control and corrosion monitoring. With ultrasonic propagation speed being temperature-dependent, the thickness measurement can be performed reliably only when the thermal profile is completely known. Most conventional techniques assume the temperature of the test structure is uniform and at room temperature across its thickness. Such assumptions may lead to large errors in the thickness measurement, especially when there are significant temperature variations across the thickness. State-of-the-art techniques use external temperature measurements or implement iterative methods to compensate for the unknown thermal profiles. However, such techniques produce unsatisfactory results when the heat distribution is complex or varies rapidly with time. In this work, we propose a two-sensors technique, using both compressive and shear excitations, with a non-iterative rapid data processing method for accurate thickness measurement under arbitrary time-variant thermal profile. The independent behavior of shear and compressive waves is used to formulate a real-time thickness estimation technique. The developed technique is experimentally validated on a steel plate with fixed acoustic sensors. Test results show that the error in thickness estimation can be reduced by up to 98% compared to conventional thickness gauging methods.

36 MATERIALS SCIENCE↗

Rapid measurement of RH-dependent aerosol hygroscopic growth using a humidity-controlled fast integrated mobility spectrometer (HFIMS)

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.

54 ENVIRONMENTAL SCIENCES↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Screening candidate supplementary cementitious materials under standard and accelerated curing through time-series surface resistivity measurements and change-point detection

Time-series surface resistivity (SR) measurements are evaluated as an indicator of pozzolanicity in concretes containing 13 materials of both known and unknown pozzolanicity, under standard and accelerated curing conditions, and the results were validated against portlandite consumption obtained through thermogravimetric analysis. Change-point detection (CPD) analysis is applied to the data to provide a rigorous indicator of hydration age of the onset and rate of the pozzolanic reaction, if occurring. The SR measurements were able to capture the onset of the pozzolanic reactions in concretes curing at elevated temperature regimes, which allows determination of pozzolanicity weeks earlier than at standard curing temperatures. Using CPD along with slope analysis allows a comprehensive analysis of a material's reactivity and determination of pozzolanicity in as quickly as two days. Time-series SR measurements at elevated curing conditions, along with limits on material composition, are recommended for determination of pozzolanic reactivity in novel or variable materials.

36 MATERIALS SCIENCE↗

Time-Resolved Structural Measurement of Thermal Resistance across a Buried Semiconductor Heterostructure Interface

The precise control and understanding of heat flow in heterostructures is pivotal for advancements in thermoelectric energy conversion, thermal barrier coatings, and efficient heat management in electronic and optoelectronic devices. In this study, we employ high-angular-resolution time-resolved X-ray diffraction to structurally measure thermal resistance in a laser-excited AlGaAs/GaAs semiconductor heterostructure. Our methodology offers femtometer-scale spatial sensitivity and nanosecond time resolution, enabling us to directly observe heat transport across a buried interface. We corroborate established Thermal Boundary Resistance (TBR) values for AlGaAs/GaAs heterostructures and demonstrate that TBR arises from material property discrepancies on either side of a nearly flawless atomic interface. This work not only sheds light on the fundamental mechanisms governing heat flow across buried interfaces but also presents a robust experimental framework that can be extended to other heterostructure systems, paving the way for optimized thermal management in next-generation devices.

36 MATERIALS SCIENCE↗

Constraining time-dependent ion temperature measurements in inertial confinement fusion (ICF) implosions with an intermediate distance neutron time-of-flight (nToF) detector

A concept for using an intermediate distance (0.3–3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

Moore, A. S. (ORCID:0000000221258882)↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Magnificent Five Images of Supernova Refsdal: Time Delay and Magnification Measurements

In late 2014, four images of supernova (SN) "Refsdal," the first known example of a strongly lensed SN with multiple resolved images, were detected in the MACS J1149 galaxy-cluster field. Following the images' discovery, the SN was predicted to reappear within hundreds of days at a new position ~8'' away in the field. The observed reappearance in late 2015 makes it possible to carry out Refsdal's original proposal to use a multiply imaged SN to measure the Hubble constant H0, since the time delay between appearances should vary inversely with H0. Moreover, the position, brightness, and timing of the reappearance enable a novel test of the blind predictions of galaxy-cluster models, which are typically constrained only by the positions of multiply imaged galaxies. We have developed a new photometry pipeline that uses DOLPHOT to measure the fluxes of the five images of SN Refsdal from difference images. We apply four separate techniques to perform a blind measurement of the relative time delays and magnification ratios between the last image SX and the earlier images S1–S4. We measure the relative time delay of SX–S1 to be 376.0$^{+5.6}_{–5.5}$ days and the relative magnification to be 0.30$^{+0.5}_{–0.3}$. This corresponds to a 1.5% precision on the time delay and 17% precision for the magnification ratios and includes uncertainties due to millilensing and microlensing. In an accompanying paper, we place initial and blind constraints on the value of the Hubble constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

The Atacama Cosmology Telescope DR6 and DESI: structure formation over cosmic time with a measurement of the cross-correlation of CMB lensing and luminous red galaxies

We present a high-significance cross-correlation of CMB lensing maps from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) with luminous red galaxies (LRGs) from the Dark Energy Spectroscopic Instrument (DESI) Legacy Survey spectroscopically calibrated by DESI. We detect this cross-correlation at a significance of 38σ; combining our measurement with the Planck Public Release 4 (PR4) lensing map, we detect the cross-correlation at 50σ. Fitting this jointly with the galaxy auto-correlation power spectrum to break the galaxy bias degeneracy with σ 8 , we perform a tomographic analysis in four LRG redshift bins spanning 0.4 ≤ z ≤ 1.0 to constrain the amplitude of matter density fluctuations through the parameter combination S 8 × = σ 8 (Ω m / 0.3) 0.4 . Prior to unblinding, we confirm with extragalactic simulations that foreground biases are negligible and carry out a comprehensive suite of null and consistency tests. Using a hybrid effective field theory (HEFT) model that allows scales as small as k max = 0.6 h/ Mpc, we obtain a 3.3% constraint on S 8 × = σ 8 (Ω m / 0.3) 0.4 = 0.792 +0.024 -0.028 from ACT data, as well as constraints on S 8 × (z) that probe structure formation over cosmic time. Our result is consistent with the early-universe extrapolation from primary CMB anisotropies measured by Planck PR4 within 1.2σ. Jointly fitting ACT and Planck lensing cross-correlations we obtain a 2.7% constraint of S 8 × = 0.776 +0.019 -0.021 , which is consistent with the Planck early-universe extrapolation within 2.1σ, with the lowest redshift bin showing the largest difference in mean. The latter may motivate further CMB lensing tomography analyses at z < 0.6 to assess the impact of potential systematics or the consistency of the ΛCDM model over cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Time Resolved Reflectivity Measurements of Convective Clouds

National Aeronautics and Space Administration's Investigations of Convective Updrafts (INCUS) mission aims to document convective mass flux through changes in the radar reflectivity (ΔZ) in convective cores captured by a constellation of three Ka-band radars sampling the same convective cells over intervals of 30, 90, and 120 s. Here, high spatiotemporal resolution observations of convective cores from surface-based radars that use agile sampling techniques are used to evaluate aspects of the INCUS measurement approach using real observations. Analysis of several convective cells confirms that large coherent ΔZ structure with measurable signal (>5 dB) can occur in less than 30 s and are correlated with underlying convective motions. The analysis indicates that the INCUS mission radar footprint and along track sampling are adequate to capture most of the desirable ΔZ signals. This unique demonstration of reflectivity time-lapse provides the framework for estimating convective mass flux independent from Doppler techniques with future radar observations.

54 ENVIRONMENTAL SCIENCES↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of early time outer laser beam reflection inside a cylindrical hohlraum at the National Ignition Facility

In a National Ignition Facility (NIF) cylindrical hohlraum, any specular reflection (“glint”) off the wall from the outer cone (incident angle of 50° and 44° relative to the surface of the wall) laser beam will irradiate the capsule poles. If the glint power is sufficiently large during the picket (early time) of the laser pulse, it may seed high-mode perturbations on the capsule surface that can grow during the implosion. To quantify the glint power on the capsule during the picket by the outer beams, we performed dedicated experiments on NIF using a flat witness foil as a surrogate for the capsule in a half-hohlraum target. We found that the measured glint power is approximately comparable to simulations using a nominal electron conduction flux limiter of f = 0.15, and over an order of magnitude lower than that predicted using f = 0.03 in the wall. Based on our current understanding, we conclude that the glint from the outer beams plays an insignificant role in capsule drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗