Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A standard capsule design for structural material testing in the Advanced Test Reactor

Nuclear materials testing is commonly completed in various material test and research reactors throughout the world, including the Advanced Test Reactor (ATR), but the current capsule design, analysis, and fabrication process can take years to complete. To decrease the costs and time associated with materials testing, a standard capsule has been designed which houses various specimen geometries and allows irradiation in virtually any ATR test position. The standard capsule features locking end caps which connect and lock together to form the capsule stack, eliminating the need for a basket and maximizing the quantity of specimens which are contained within the capsule. A customizable internal gas gap provides thermal resistance between the specimens and reactor coolant, making specimen temperatures from approximately 370 to 1000 K achievable. The flexibility of the capsule design allows experimenters to choose irradiation positions based off desired neutron flux, with typical fluences per cycle ranging from 8.8x10 19 to 2.3x10 21 n/cm 2 , depending on experiment position. Here this paper presents and discusses the standard capsule design and analysis.

36 MATERIALS SCIENCE↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Thermal compensation of molded silicone optics

Optical grade silicone has various properties that make it attractive for solar concentrators, such as excellent transmission across the solar spectrum and flexible moldability for freeform profiles. In this study, a glass–silicone lens structure is proposed to reduce the optothermal effect on the silicone lens. Experimental measurements and simulation modeling results demonstrate that the focal length sensitivity of the glass–silicone lens with respect to temperature can be reduced by a factor of 10 when compared to a silicone lens alone. This model has been extended to the simulation of a proposed two-stage silicone solar concentrator, consisting of an array of acylindrical lenslets and rows of waveguides that focus light onto microphotovoltaic cells. The optical efficiency of the solar concentration system showed a change of less than 10% compared to the efficiency at room temperature for temperature changes from − <#comment/> 10 ∘ <#comment/> C to 70°C.

Lyons, Nicholas P.↗

Manipulating Conjugated Polymer Backbone Dynamics through Controlled Thermal Cleavage of Alkyl Side Chains

The morphological stability of an organic photovoltaic (OPV) device is greatly affected by the dynamics of donors and acceptors occurring near the device's operational temperature. These dynamics can be quantified by the glass transition temperature (T g ) of conjugated polymers (CPs). Because flexible side chains possess much faster dynamics, the cleavage of the alkyl side chains will reduce chain dynamics, leading to a higher T g . In this work, the T g s for CPs are systematically studied with controlled side chain cleavage. Isothermal annealing of polythiophenes featuring thermally cleavable side chains at 140 °C, is found to remove more than 95% of alkyl side chains in 24 h, and raise the backbone T g from 23 to 75 °C. Coarse grain molecular dynamics simulations are used to understand the T g dependence on side chain cleavage. X-ray scattering indicates that the relative degree of crystallization remains constantduring isothermal annealing process. The effective conjugation length is not influenced by thermal cleavage; however, the density of chromophore is doubled after the complete removal of alkyl side chains. Here, the combined effect of enhancing T g and conserving crystalline structures during the thermal cleavage process can provide a pathway to improving the stability of optoelectronic properties in future OPV devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The STAT7 Code for Statistical Propagation of Uncertainties in Steady State Thermal Hydraulics Analysis of Plate Fueled Reactors

The STAT7 software was developed to perform steady-state thermal hydraulic analyses. Application of the software is for non-power research and test reactors, including conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors such as MITR-II. Since it can be necessary to repeat analysis during fuel reloading, STAT7 accommodates flexibility in analyzing many realistic aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model common fabrication parameters and other key reactor analysis uncertainties required for research and test reactor thermal hydraulic analyses. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux or departure from nucleate boiling or onset of flow instability; but additional margin is obtained by basing the limiting safety settings on avoiding onset of nucleate boiling. STAT7 can simultaneously analyze all of the axial nodes of all of the fuel plates and all of the coolant channels for one lateral stripe of a fuel element. The stripes run the length of the fuel, from the bottom to the top. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. By running STAT7 multiple times, full core analysis can be performed by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each element in the core.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chain Flexibility and Structure of a Polyimide Copolymer: Revisiting the Freely Rotating Chain Model

Poly(4–4′-oxydiphenylene-pyromellitimide)-based polyimides─trade name Kapton─have wide-ranging engineering applications owing to their thermal and mechanical stability, but little is known about underlying chain-level characteristics. While theoretical models have conceptualized Kapton as inflexible polycyclic rods separated by freely rotating diphenyl ether hinge groups, the model’s core predictions remain untested and subtleties of the relaxation behavior are missed, which atomistic modeling can resolve. To these ends, we examine all-atom Kapton structures in crystalline and glassy amorphous configurations using a DFT-validated class II force field. Constructing amorphous configurations is challenging, as the fused-ring-containing backbone has slow relaxation dynamics and scaling suggestive of entanglements even in oligomers. In conclusion, we find larger backbone rearrangements of the linear polycyclic segments about ether groups that are consistent with the rod-hinge picture on the monomer scale, whereas a ring rotation analysis suggests partially flexible rod-like segments and involves multiple facile rotational relaxation modes.

Liesen, Nicholas T. [Lawrence Livermore National L↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Atomic layer deposition of nanofilms on porous polymer substrates: Strategies for success

Atomic layer deposition (ALD) is a versatile technique for engineering the surfaces of porous polymers, imbuing the flexible, high-surface-area substrates with inorganic and hybrid material properties. Previously reported enhancements include fouling resistance, electrical conductance, thermal stability, photocatalytic activity, hydrophilicity, and oleophilicity. However, there are many poorly understood phenomena that introduce challenges in applying ALD to porous polymers. In this paper, we address five common challenges and ways to overcome them: (1) entrapped precursor, (2) embrittlement, (3) film fracture, (4) deformation, and (5) pore collapse. These challenges are often interrelated and can exacerbate one another. To investigate these phenomena, we applied various ALD chemistries to porous polymers including polyethersulfone, polysulfone, polyvinylidene fluoride, and polycarbonate track-etched membranes. Reaction-diffusion modeling revealed why certain precursors and processing conditions result in embrittling subsurface material growth, entrapment of unreacted precursors, and nongrowth. We quantify the limits of ALD processing temperatures that are dictated by thermal expansion mismatch and can lead to fractured ALD films. The results herein allow us to make recommendations to avoid, mitigate, or overcome the difficulties encountered when performing ALD and plasma-enhanced ALD on porous polymers. We intend this article to serve as a “lessons learned” guide informed by previous experience to provide a better understanding of the difficulties and limitations of ALD on porous polymers and knowledge-based guidelines for successful depositions. This knowledge can accelerate future research and help experimentalists navigate and troubleshoot as they expose porous polymers to reactive precursor vapors.

36 MATERIALS SCIENCE↗

Demonstrate FARM supervisory capabilities for a thermal energy storage problem for the DETAIL facility: IES Simulation Ecosystem Control System Development

The goal of the power dispatch problem for an Integrated Energy System (IES) is to adjust the power output and the heat flow of each component to maximize the profitability of the whole unit. Facilities that can integrate real-time digital signals, mock nuclear power, thermal energy storage and industrial heat use via high-temperature electrolysis were constructed at INL to support the research activities. The Dynamic Energy Technology and Integration Laboratory (DETAIL) houses the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET) and the Thermal Energy Distribution System (TEDS). In this report, the hierarchical control system architecture proposed in June 2023 milestone for the flexible operation of DETAIL facility is finalized and demonstrated. A brief description of the components and the corresponding Dymola models from the HYRBID repository is first provided. Then, the current control strategy is presented. In particular, the approach for generating the set-point trajectories to be fed to the PI controllers is analyzed, and its limits were identified. To preserve safe operation over both long-time and real-time horizons, the integration of a Supervisory Control layer embedding a modified version of FARM (Feasible Actuator Range Modifier) module is proposed. FARM is a component of the RAVEN-based FORCE framework designed to support HERON module at optimizing the operation of IES units. The proposed control system for DETAIL foresees FARM to be applied twice, i.e., the original version (“FARM-Validator”) aiding the solution of the power dispatch problem, and a modified version (“FARM-Supervisory”) coordinating the PID controllers. Despite the kernel of the two modules is the same, their tasks are quite different. The former intervenes at the beginning of each hour to prevent constraint violations over long time periods, the latter addresses real-time control tasks and monitors the response of constrained variables at a much finer time resolution. A tentative procedure for training the embedded Digital Twins with the experimental data is also proposed. Finally, the capabilities of the designed architecture and the impact of the added Supervisory Control layer are demonstrated by simulating a representative power dispatch scenario.

25 ENERGY STORAGE↗

Anodic arc discharge: Why pulsed?

Pulsed anodic arc discharge is a novel synthesis method of nanomaterials by means of low-temperature atmospheric plasma. The technique consists in periodically supplying DC power to two vertically aligned electrodes in the form of short unipolar pulses with peak currents of a few hundred Amperes in helium atmosphere. The pulsed arc plasmas are sustained at frequencies of the order of 1 Hz with around 10% of duty cycle. It constitutes a versatile technique thanks to a series of advantages compared to continuous DC arc processes, in particular: flexibility in the experimental conditions, process stability and repeatability, better utilization of ablating anode material, lower production of macroparticles, and lower thermal loads. Such features are discussed in this article. A brief overview concerning the recent accomplishments of pulsed arc discharge on deposition of carbon nanostructures (graphene and carbon nanotubes) and few-layer flakes of molybdenum disulphide (MoS 2 ) is provided, as well as an outlook on future applications of this method for the discovery of new materials with tailored functional properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of Material Properties of Aged Rigid Polyurethane Foam

Foams are classified as either rigid or flexible and are commonly used in applications such as pipe insulation, carpet fibers, and chair foam cushions. Polyurethane foams are excellent thermal insulators, have excellent mechanical properties, and are chemically inert. With the addition of fire protective additives, polyurethane foams have the ability to intumescence when exposed to high temperatures. For the future storage of the 9977 nuclear shipping packages, the material properties of the General Plastics 3716 rigid polyurethane foam were evaluated for long term performance by comparing aged samples to unaged samples. General Plastics 3716 rigid polyurethane foam was aged from November 2014 to June 2019 at varying temperatures of: 160 deg. F, 160 deg. F + 50% relative humidity (RH), 185 deg. F, 215 deg. F, and 250 deg. F. The foam was then analyzed via Fourier Transform Infrared Spectroscopy (FTIR), 3D Optical Microscope, Thermal Gravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC). FTIR and Optical Microscope: No significant change to chemical or physical structure was evident by FTIR or optical microscope analysis. DSC: Decrease of heat capacity over time for all oven temperatures except a slight increase for the 185 deg. F conditioned foams. Largest decrease evident with foams conditioned at 250 deg. F. A slight increase in heat capacity for humid samples. Similar trends in heat capacities at 71 deg. C and 102 deg. C. TGA: As conditioning temperature increased, a decline was evident in the average percent weight loss, onset temperature, and first derivative peak temperature. No significant effect due to humidity except for a decrease in first derivative peak temperature. Unaged samples exhibited strong intumescence. Foams conditioned at 160 deg. F exhibited slight intumescence. Results suggest fire protective additives decomposed at higher temperatures, which contributed to a lower average percent mass loss in higher temperature conditioning. Further thermal degradation testing would be beneficial to evaluate the ability of the conditioned foams to intumesce. Evaluate irradiation dose rate effects on conditioned foam. Possible conditioning in an environment with a known humidity or analyzing a new aliquot of sample for each trial to achieve a more representative heat capacity calculation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tabulated Fluid Properties Research Report

The Multiphysics Object-Oriented Simulation Environment (MOOSE) enables a wide range of advanced nuclear reactor simulations.[6] Under the guidance of MOOSE’s Thermal Hydraulics Team,I worked to expand the capabilities of Tabulated Fluid Properties (TFP) in the fluid properties module. The fluid properties module allows the user to determine a variety of fluid properties by interpolating points between tabulated data. I implemented the ability to use bilinear interpolation instead of bicubic interpolation for interpolating tabulated data. I also changed the method of variable set inversions to use a 2-dimensional Newton’s Method utility that I created. Variable set inversions are often done from (v,e) to (p,T), where v is specific volume, e is specific internal energy, p is pressure and T is temperature. New routines have also been added into TFP such that it can be used with more applications, such as the Navier Stokes and Thermal Hydraulics modules in MOOSE for Pronghorn[5] and RELAP-7[1] respectively. This work was spurred by interest from NASA in testing a Nuclear Thermal Propulsion (NTP) engine system. NTP engines have drastically different fluid properties throughout the engine and Tabulated Fluid Properties provides the flexibility needed to properly simulate and test these engines.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STAT7 v1.2 User Guide: The STAT7 Code for Statistical Propagation of Uncertainties in Steady-State Thermal Hydraulics Analysis of Plate-Fueled Reactors

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software is for non-power research and test reactors, including conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors such as Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat analysis during fuel reloading, STAT7 accommodates flexibility in analyzing many realistic aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for thermal hydraulics analyses of research and test reactors. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to the fit functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze all of the axial nodes of all of the fuel plates and all of the coolant channels for one latera stripe of a fuel element. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. By running STAT7 multiple times, full core analysis can be performed by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of a Thermally Integrated Solid Oxide Fuel Cell and Compressed Air Energy Storage Hybrid System

Natural-gas-fueled solid oxide fuel cell (SOFC) systems have the potential for high-efficiency conversion of carbon to power due to the underlying electrochemical conversion process while readily facilitating carbon capture through the separation of the fuel and oxidant sources. Compressed air energy storage (CAES) technology can potentially store significant quantities of energy for later use with a high round-trip efficiency and lower cost when compared with state-of-the-art battery technology. The base load generation capability of SOFC can be coupled with CAES technology to provide a potentially flexible, low-carbon solution to meet the fluctuating electricity demands imposed by the increasing share of intermittent variable renewable energy (VRE) production. SOFC and CAES can be hybridized through thermal integration to maximize power output during periods of high electrical demand and then store power when either demand is low or renewable generation reduces power prices. The techno-economics of a low-carbon hybrid SOFC and CAES system was developed and investigated in the present study. The proposed hybrid system was found to be cost-competitive with other power-generating base-load facilities when power availability was considered. The hybrid system shows increased resilience to changes in a high VRE grid market scenario.

25 ENERGY STORAGE↗

Packaging Development for a 1200V SiC BiDFET Switch Using Highly Thermally Conductive Organic Epoxy Laminate

A novel 1.2 kV/10A, 4H-SiC monolithic, bidirectional switch has been developed for use in cycloconverter applications to facilitate high-frequency direct AC-to-AC power conversion and enables new power converter topologies. A new packaging solution, utilizing a 100 µm flexible polyimide organic laminate substrate is developed to mitigate thermo-mechanical stress during power cycling and enable smaller form factor and lower cost. Multiphysics simulations and static tests were conducted to show performance characterization of the module and compare it against metallic substrates. A new organic laminate epoxy resin composite dielectric (ERCD) is also evaluated for superior thermal performance and shows 63% reduction in junction to case resistance compared to DBC substrates.

Silicon Carbide, Bi-directional switch, BiDFET, MO↗

In situ chamber for studying battery failure using high-speed synchrotron radiography

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

25 ENERGY STORAGE↗

Solid-State, Single-Ion Conducting, Polymer Blend Electrolytes with Enhanced Li + Conduction, Electrochemical Stability, and Limiting Current Density

The development of solid-state polymer electrolytes with high lithium conductivity is crucial to improve lithium-ion battery performance and ameliorate the safety challenges associated with current solvent-based electrolytes. Unfortunately, sluggish polymer segmental dynamics are known to constrain conductivity enhancements in solid-state polymer electrolyte systems, limiting overall performance. In this work, a glassy single-ion-conducting polymer, poly[lithium sulfonyl(trifluoromethane sulfonyl)imide methacrylate] (PLiMTFSI), was blended with a flexible polymer, poly(oligo-oxyethylene methyl ether methacrylate) (POEM), and the impact of PLiMTFSI molecular weight and ion concentration on the thermal and ion-conducting behavior of blend electrolytes was investigated. High ionic conductivities approaching 1 × 10 -2 S/cm at 150 °C were realized in this polymer blend electrolyte system as a result of decoupling Li + transport from polymer segmental dynamics. The decoupled ion transport was attributed to the packing frustration of the glassy PLiMTFSI – sufficient percolating free volume was generated to produce effective ion diffusion pathways. This decoupling was tunable as the ion transport could be altered from being closely coupled to the polymer segmental dynamics (Vogel–Tammann–Fulcher-like) to hopping (Arrhenius-like) by increasing the PLiMTFSI molecular weight and ion concentration. Moreover, the immobilized TFSI anion resulted in high Li + selectivity (Li + transference number = 0.9), high electrochemical stability (up to 4.7 V against Li + / Li), and limiting current density of 1.8 mA/cm 2 (electrolyte thickness = 0.05 cm). These features suggest that this single-ion-conducting, polymer blend electrolyte might be a promising alternative to a benchmark system – salt-doped polyethylene oxide. Moreover, the above characteristics can support the battery operation at higher voltages using energy-dense Li metal anodes, with faster charging rates and enhanced energy/power densities. Altogether, the results suggest that polymer chain packing frustration can be exploited to overcome the constraints of slow polymer segmental relaxations to achieve rapid and highly selective ion transport and enhanced performance in solid-state polymer electrolytes.

36 MATERIALS SCIENCE↗