How do we establish cardiac sympathetic nervous system imaging with {sup 123}I-mIBG in clinical practice? Perspectives and lessons from Japan and the US

Cardiac denervation is associated with progressive left ventricular (LV) dysfunction, ventricular arrhythmias, and sudden cardiac death (SCD) in heart failure (HF). In this regard, it is important to evaluate cardiac-specific sympathetic nervous system (SNS) function. The radiotracer Iodine-123 meta-iodobenzylguanidine ({sup 123}I-mIBG) can noninvasively evaluate pre-synaptic SNS function. Recent multicenter trials have shown {sup 123}I-mIBG to have strong predictive value for fatal arrhythmias and cardiac death in HF. {sup 123}I-mIBG was initially developed in the USA in the 1970s. In 1992, the Japanese Ministry of Health and Labour approved {sup 123}I-mIBG for the assessment of cardiac function. Following approval, the Japanese nuclear cardiology community developed {sup 123}I-mIBG imaging services in various medical centers. Japanese groups have been trying to establish the clinical utility of {sup 123}I-mIBG and standardize parameters for data acquisition and image analysis. The US Food and Drug Administration (FDA) has approved clinical use of {sup 123}I-mIBG for cardiac and non-cardiac imaging. However, clinical use of {sup 123}I-mIBG in the US has been very limited. The number of {sup 123}I-mIBG studies in Japan has also been limited. There are similarities and differences between the two countries. To establish the clinical utility of {sup 123}I-mIBG in both countries, it is important to characterize the situations of {sup 123}I-mIBG in each.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of global and local deformation in additively manufactured octet truss lattice structures

Additively manufactured lattice truss structures, often referred to as architected cellular materials, present significant advantages over conventional structures due to their unique characteristics such as high strength-to-weight ratios and surface area-to-volume ratios. These geometrically complex structures, however, come with concomitant challenges for qualification and inspection. In this study, compression testing interrupted with micro-computed tomography inspection was conducted to monitor the evolution of global and local deformation throughout the loading process of 304L stainless steel octet truss lattice structures. Both two- and three-dimensional image analysis techniques were leveraged to characterize geometric heterogeneities resulting from the laser powder bed fusion manufacturing process as well as track the structure throughout deformation. Variations from model-predicted behavior resulting from these heterogeneities are considered relative to the predicted and actual responses of the structures during compression to better understand, model, and predict the octet truss lattice structure compression response.

36 MATERIALS SCIENCE↗

Estimation of local stresses and elastic properties of a mortar sample by FFT computation of fields on a 3D image

This study concerns the prediction of the elastic properties of a 3D mortar image, obtained by micro-tomography, using a combined image segmentation and numerical homogenization approach. The microstructure is obtained by segmentation of the 3D image into aggregates, voids and cement paste. Full-fields computations of the elastic response of mortar are undertaken using the Fast Fourier Transform method. Emphasis is made on highly-contrasted properties between aggregates and matrix, to anticipate needs for creep or damage computation. The representative volume element, i.e. the volume size necessary to compute the effective properties with a prescribed accuracy, is given. Overall, the volumes used in this work were sufficient to estimate the effective response of mortar with a precision of 5%, 6% and 10% for contrast ratios of 100, 1000 and 10,000, resp. Finally, a statistical and local characterization of the component of the stress field parallel to the applied loading is carried out.

36 MATERIALS SCIENCE↗

Three-Dimensional Imaging Using Microcomputed Tomography For Studying Gaharu Morphology

To demonstrates the potential application of the high resolution X-ray micro-CT technique in the analysis of internal structure in Gaharu wood. Gaharu or internationally, Agar wood, is known for its fragrant resinous wood. The hardware device used in this study was an X-ray micro-CT scanner at Center of Tomography (UGCT), CT facility in Ghent University, Belgium. This technique allows the 3D investigation of the internal structure of the wood in a non-destructive way. Most of the data analysis was done with the software VG Studio Max and MATLAB. Here we present some preliminary results from three-dimensional images from a piece of high grade Gaharu. Micro-CT images of the specimens were obtained at 7 mum resolution. Besides a clear distinction between pores and material, some bright white areas occur in the reconstruction images. Not only the volume visualization is helpful, morphological parameters of open-pores and dark resins are calculated from these 3D data set. The micro-CT technique is a valid support for evaluating the pores structure and resin distribution in Gaharu.

36 MATERIALS SCIENCE↗

Monte Carlo Simulation of Emission Tomography and other Medical Imaging Techniques

As an introduction to Monte Carlo simulation of emission tomography, this paper reviews the history and principles of Monte Carlo simulation, then applies these principles to emission tomography using the public domain simulation package SimSET (a Simulation System for Emission Tomography) as an example. Finally, the paper discusses how the methods are modified for X-ray computed tomography and radiotherapy simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo Simulation of PET of a Real Patient with GATE

The objective of this work is to perform a Monte Carlo simulation with GATE software tool of a realistic numerical phantom of a real patient. Results from the simulation, in terms of simulated decays, recorded coincidences and simulation time, are presented. Output data are reconstructed using the Software for Tomographic Image Reconstruction (STIR) package. Two different STIR image reconstruction algorithms are used to perform the reconstruction-Filtered Back Projection/3DRP and Ordered Subset Maximum A Posteriori One-Step Late algorithms. Reconstructed images are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetry in Mammography: Average Glandular Dose Based on Homogeneous Phantom

The objective of this study was to demonstrate that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 and 46 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

61 RADIATION PROTECTION AND DOSIMETRY↗

Classification procedure in limited angle tomography system

In this work we propose the use of limited angle reconstruction algorithms combined with a procedure for defect detection and feature evaluation in three dimensions. The procedure consists of the following steps: acquisition of the X-ray projections, approximated limited angle 3D image reconstruction, and image preprocessing and classification.

07 ISOTOPE AND RADIATION SOURCES↗

Readout models for BaFBr 0.85 I 0.15 :Eu image plates

The linearity of the photostimulated luminescence process makes repeated image-plate scanning a viable technique to extract more dynamic range. In order to obtain a response estimate, two semi-empirical models for the readout fading of an image plate are introduced; they relate the depth distribution of activated photostimulated luminescence centers within an image plate to the recorded signal. Model parameters are estimated from image-plate scan series with BAS-MS image plates and the Typhoon FLA 7000 scanner for the hard x-ray image-plate diagnostic over a collection of experiments providing x-ray energy spectra whose approximate shape is a double exponential.

47 OTHER INSTRUMENTATION↗

Deep drilling in the time domain with DECam: survey characterization

ABSTRACT This paper presents a new optical imaging survey of four deep drilling fields (DDFs), two Galactic and two extragalactic, with the Dark Energy Camera (DECam) on the 4-m Blanco telescope at the Cerro Tololo Inter-American Observatory (CTIO). During the first year of observations in 2021, >4000 images covering 21 deg2 (seven DECam pointings), with ∼40 epochs (nights) per field and 5 to 6 images per night per filter in g, r, i, and/or z have become publicly available (the proprietary period for this program is waived). We describe the real-time difference-image pipeline and how alerts are distributed to brokers via the same distribution system as the Zwicky Transient Facility (ZTF). In this paper, we focus on the two extragalactic deep fields (COSMOS and ELAIS-S1) characterizing the detected sources, and demonstrating that the survey design is effective for probing the discovery space of faint and fast variable and transient sources. We describe and make publicly available 4413 calibrated light curves based on difference-image detection photometry of transients and variables in the extragalactic fields. We also present preliminary scientific analysis regarding the Solar system small bodies, stellar flares and variables, Galactic anomaly detection, fast-rising transients and variables, supernovae, and active Galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Electron Photodetachment of Negative Ions in a Strong Laser Field

We study the photodetachment of H{sup -}, F{sup -}, and Br{sup -} in a short laser pulse of 800 nm wavelength and 6x10{sup 14} W/cm{sup 2} peak intensity. Photoelectron spectra, recorded with the use of an imaging technique, reveal a substantial contribution from the sequential process of double detachment of halogen negative ions. The saturation effect is shown to play a crucial role in this process. The role of the alignment of atoms produced by photodetachment is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hyperspectral image reconstruction for x-ray fluorescence tomography

A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

Fluorescence microscopy↗

Influence of Vegetation Canopy Architecture on Dynamics of Spatiotemporal Light Distribution and its Effect on Land-Biosphere-Atmosphere Fluxes of Energy, Carbon, and Water

The dynamic spatiotemporal distribution of light and micro climatic variables (wind speed, atmospheric CO 2 concentration, humidity, pressure, and air temperature) within the plant canopy as determined by the canopy architecture play a critical role in land-biosphere-atmosphere (LBA) photosynthetic carbon uptake, transpiratory water loss and energy partitioning. Vegetation models that include effects of sun and shade flecks, leaf temperature and energy balance partitioning between sensible and latent heat fluxes, and reduced turbulent mixing in dense vegetation canopies can accurately predict canopy performance, particularly its shaded leaves, which can constitute 80% of leaf area and contribute up to 50% of carbon update and 65% of water loss. However, current vegetation models with their bulk characterization of shaded leaves poorly represent the complex three dimensional (3D) canopy architecture are insufficient to capture the spatiotemporal dynamics of shaded leaves. Here, we propose to employ an x-ray computed tomography (XCT) imaging technique in combination with an automated, high throughput, image processing pipeline (3DArch, to be developed) to obtain an explicit 3D triangulated surface mesh of a plant canopy (Fig 1). 3DArch would provide a much needed technological jump in 3D LBA modeling where computer generated artificial 3D models suffer from lack of high resolution detailed canopy architecture parameters. The 3D canopy surface mesh output from 3DArch is coupled with an explicit 3D forward ray tracing model (fastTracer) to obtain a high resolution representation of the dynamic spatiotemporal light environment within the canopy over the course of a day (Fig 1). The results from the light attenuation model are then coupled with a process based multi-scale bio-physical canopy and leaf model of photosynthesis (PlantGro) to get fluxes of carbon, water and energy at the leaf and canopy scale, in addition to estimating whole plant carbon uptake, and water loss. Our proposed model framework would be the first of its kind to provide a breakthrough capability in the field of process-based plant modeling that bridges the key technological gap in shaded leaf modeling through explicit representation of 3D canopy architecture. Computer generated artificial 3D model canopy simulations on grasses show that the canopy light distribution does not follow an exponential behavior as assumed in most 1D vegetation models, but rather exhibits a heterogeneous behavior, with a small but significant portion of interior canopy leaves experiencing peak light levels due to sun flecks while the rest of the canopy receives substantially lower light levels. These results indicate a bias in traditional models that overestimates shaded leaf contribution towards whole canopy photosynthesis by up to 15% and underestimate transpiration by up to 12% with an associated increase in sensible heat fluxes since photosynthesis, transpiration and energy partitioning are tightly coupled processes. However, these test results need to be validated using the 3D architecture obtained from a real plant imaged in 3D using 3DArch, rather than an artificial model plant. Our proposed model framework would allow us to identify inefficiencies in canopy light distribution and prescribe optimal canopy architectures (leaf optical properties, leaf area, leaf angles, row spacing, planting density, etc.) to traditional and genetic engineering based crop breeders, for maximizing target functions such as light use efficiency, water use efficiency, drought tolerance, crop yield, crop resilience etc., with important applications in biofuel crops such as sorghum, and switchgrass. Our model can also be applied for designing optimal canopy architecture that increase surface albedo as a mitigation strategy for global warming and projections of crop yield for future food and water security under climate change.

59 BASIC BIOLOGICAL SCIENCES↗

The Dark Energy Survey Data Release I

We describe the first public data release of the Dark Energy Survey, DES DR1, consisting of reduced single-epoch images, co-added images, co-added source catalogs, and associated products and services assembled over the first 3 yr of DES science operations. DES DR1 is based on optical/near-infrared imaging from 345 distinct nights (2013 August to 2016 February) by the Dark Energy Camera mounted on the 4 m Blanco telescope at the Cerro Tololo InterAmerican Observatory in Chile. We release data from the DES wide-area survey covering similar to 5000 deg(2) of the southern Galactic cap in five broad photometric bands, grizY. DES DR1 has a median delivered point-spread function of g = 1.12, r = 0.96, i = 0.88, z = 0.84, and Y = 0.'' 90 FWHM, a photometric precision of <1% in all bands, and an astrometric precision of 151 mas. The median co-added catalog depth for a 1.'' 95 diameter aperture at signal-to-noise ratio (S/N) = 10 is g = 24.33, r = 24.08, i = 23.44, z = 22.69, and Y = 21.44 mag. DES DR1 includes nearly 400 million distinct astronomical objects detected in similar to 10,000 co-add tiles of size 0.534 deg(2) produced from similar to 39,000 individual exposures. Benchmark galaxy and stellar samples contain similar to 310 million and similar to 80 million objects, respectively, following a basic object quality selection. These data are accessible through a range of interfaces, including query web clients, image cutout servers, jupyter notebooks, and an interactive co-add image visualization tool. DES DR1 constitutes the largest photometric data set to date at the achieved depth and photometric precision.

Abbott, T. M. C.↗

Imaging and sensing based on muon tomography

Techniques, apparatus and systems for detecting particles such as muons for imaging applications. Subtraction techniques are described to enhance the processing of the muon tomography data.

47 OTHER INSTRUMENTATION↗

Summary report of the 4th IAEA Technical Meeting on Fusion Data Processing, Validation and Analysis (FDPVA)

The objective of the Fourth Technical Meeting on Fusion Data Processing, Validation and Analysis was to provide a platform during which a set of topics relevant to fusion data processing, validation and analysis are discussed with the view of extrapolating needs to next step fusion devices such as ITER. The validation and analysis of experimental data obtained from diagnostics used to characterize fusion plasmas are crucial for a knowledge-based understanding of the physical processes governing the dynamics of these plasmas. This paper presents the recent progress and achievements in the domain of plasma diagnostics and synthetic diagnostics data analysis (including image processing, regression analysis, inverse problems, deep learning, machine learning, big data and physics-based models for control) reported at the meeting. The progress in these areas highlight trends observed in current major fusion confinement devices. A special focus is dedicated on data analysis requirements for ITER and DEMO with a particular attention paid to artificial intelligence for automatization and improving reliability of control processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗