Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Public Mobility Using On-Demand, Low-Speed Electric Vehicles: A Case Study in Downtown St. Louis, Missouri

Legacy fixed route transit systems designed to serve commuters struggle to provide efficient and effective service for short neighborhood trips and for population groups unable to access and egress transit stops using active modes (e.g., elderly, disabled). Neighborhood on-demand transit (ODT) services using low-speed electric vehicles (LSEV) are an innovative technological solution that can help fill this gap in service (e.g., short, high-frequency trips) for diverse populations and trip types. This study evaluated user characteristics and travel behavior for a neighborhood ODT service (using LSEVs) in downtown St. Louis, Missouri using responses from a community survey (n=244), ridership data, and vehicle trajectory information. A comparative analysis between neighborhood ODT, fixed route transit, and transportation network companies (TNC) was also conducted from the perspectives of total travel time, cost, and greenhouse gas emissions. Ultimately, the goal of the analysis was to motivate and inform holistic public mobility systems where different services are optimized to meet specific community needs. Findings indicate that the neighborhood ODT was effective at reaching diverse populations (elderly (20%), lower income (27%), and households with limited access to private vehicles (34%)). ODT reduced total travel time by 32% compared to fixed route transit, produced 2.4 - 4.3 times less greenhouse gas emissions per passenger mile (compared to transit and TNCs), and was more affordable (free to users) than alternative options ($1 for transit, $10-12 for TNCs). Overall satisfaction rates were high, with 80% of respondents rating the service a 4 or 5 out of 5.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Public Mobility Using On-Demand, Low-Speed Electric Vehicles: A Case Study in Downtown St. Louis, Missouri

Legacy fixed route transit systems designed to serve commuters struggle to provide efficient and effective service for short neighborhood trips and for population groups unable to access and egress transit stops using active modes (e.g., elderly, disabled). Neighborhood on-demand transit (ODT) services using low-speed electric vehicles (LSEV) are an innovative technological solution that can help fill this gap in service (e.g., short, high-frequency trips) for diverse populations and trip types. This study evaluated user characteristics and travel behavior for a neighborhood ODT service (using LSEVs) in downtown St. Louis, Missouri using responses from a community survey (n=244), ridership data, and vehicle trajectory information. A comparative analysis between neighborhood ODT, fixed route transit, and transportation network companies (TNC) was also conducted from the perspectives of total travel time, cost, and greenhouse gas emissions. Ultimately, the goal of the analysis was to motivate and inform holistic public mobility systems where different services are optimized to meet specific community needs. Findings indicate that the neighborhood ODT was effective at reaching diverse populations (elderly (20%), lower income (27%), and households with limited access to private vehicles (34%)). ODT reduced total travel time by 32% compared to fixed route transit, produced 2.4 - 4.3 times less greenhouse gas emissions per passenger mile (compared to transit and TNCs), and was more affordable (free to users) than alternative options ($1 for transit, $10-12 for TNCs). Overall satisfaction rates were high, with 80% of respondents rating the service a 4 or 5 out of 5.

ADVANCED PROPULSION SYSTEMS↗

Ultrasonic Communication in Solid Channels using OFDM

Using an ultrasonic signal for communication is an alternate solution when electromagnetic waves are not feasible for carrying the information through the channel. We can use the ultrasonic signal to conduct communication in different types of media such as solid, liquid, and gas. In this study, we use ultrasound for communication through a metal plate channel. A metal plate is a highly dispersive and frequency selective channel with a severe multipath effect. The OFDM modulation method is customized for the ultrasonic communication channel to enhance communication reliability and reduce the bit error rate. With the channel frequency response, we adaptively map the transmitted information to optimize the selection of subcarriers frequency bands for the highest possible throughput.

OFDM↗

System and method for in-process inspection within advanced manufacturing processes

A system and method can include a laser Doppler vibrometer (LDV) in optical communication with a part during manufacturing and a transducer in ultrasonic communication with the part during manufacturing. The system can also include a controller connected to both the LDV and the transducer. The controller may be configured to cause the transducer to vibrate the part during manufacturing at a predetermined frequency and the LDV may be configured to measure one or more mechanical response types of the part during manufacturing based on one or more optical characteristics of a reflected beam. The controller may further be configured to determine whether a defect is present in the part during manufacturing in response to the one or more mechanical response types of the part.

42 ENGINEERING↗

Nonlinear modeling and performance analysis of cracked beam microgyroscopes

Cracks constitute a common structural defect in microelectromechanical systems that may arise during manufacturing, mechanical fatigue, or shock loading. Areas weakened by cracks increase the flexibility of the microstructure. Furthermore, depending on the crack severity, the increased flexibility can cause dramatic changes in the static and dynamic behaviors of electrically actuated MEMS. In this study, a numerical investigation of the depth and location of multiple edge cracks on the performance of beam microgyroscopes is conducted. Applying the Griffith strain energy release theorem for an edge crack, the vibrational characteristics of microgyroscopes with multiple cracks including the static deflection, natural frequencies, and mode shapes are studied analytically. Then, the differential quadrature method is employed to model the nonlinear dynamic behaviors of the cracked gyroscope system. Cracks initiated along the driving or sensing directions of the microgyroscope are found to have differing effects on its nonlinear dynamic response. This numerical study reveals that the onset of severe single cracks or a series of multiple cracks can significantly affect the sensitivity of the microgyroscope to base rotations and therefore leads to a degradation in the performance of the damaged MEMS sensor. This study also shows that a potential design approach for broadband microgyroscope systems manufactured with cracks can be proposed.

42 ENGINEERING↗

Geometric electrostatic particle-in-cell algorithm on unstructured meshes

We present a geometric particle-in-cell (PIC) algorithm on unstructured meshes for studying electrostatic perturbations with frequency lower than electron gyrofrequency in magnetized plasmas. In this method, ions are treated as fully kinetic particles and electrons are described by the adiabatic response. The PIC method is derived from a discrete variational principle on unstructured meshes. To preserve the geometric structure of the system, the discrete variational principle requires that the electric field is interpolated using Whitney 1-forms, the charge is deposited using Whitney 0-forms and the electric field is computed by discrete exterior calculus. The algorithm has been applied to study the ion Bernstein wave (IBW) in two-dimensional magnetized plasmas. The simulated dispersion relations of the IBW in a rectangular region agree well with theoretical results. In a two-dimensional circular region with fixed boundary condition, the spectrum and eigenmode structures of the IBW are obtained from simulations. We compare the energy conservation property of the geometric PIC algorithm derived from the discrete variational principle with that of previous PIC methods on unstructured meshes. The comparison shows that the new PIC algorithm significantly improves the energy conservation property.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMT and Phasor-Domain Co-simulation of a Low Frequency AC Transmission System for Offshore Wind Integration

This work investigates system level interactions of multi-terminal low frequency high-voltage alternating current (LF-HVac) system using back-to back converters and grid-level 60 Hz system. A co-simulation framework by integrating high- fidelity dynamic model of multi-terminal LF-HVac system in electromagnetic transient (EMT) simulation platform and phasor model of IEEE 39 bus system in transient-stability (phasor) program. The co-simulation framework for multi-terminal LF- HVac system with offshore wind integrated in a bulk power system is developed successfully and its steady state and dynamic operation is demonstrated and compared with EMT simulation. The co-simulation results show accurate representation of the dynamic responses with reduced computation burden and time compared to EMT platform.

low-frequency transmission, co-simulation, electro↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Optical response of a dual membrane active–passive optomechanical cavity

Highlights: • The optical response is determined by competition between photon-tunneling, two-phonon process, gain effect. • The photon-tunneling adjusts supermode frequency. • The absorption coefficient can exceed 1. • Not only realize fast/slow light but conversion between fast and slow light. We investigate a dual membrane active–passive cavity where each mechanical membrane individually quadratically coupled to passive and active cavities via two-phonon process. Due to the fact that in the quadratically coupled optomechanical system mean-field approximation fails, hence to analyze the system completely, we switch to a more generalized out of equilibrium approach, namely Keldysh Green’s functional approach. We calculate transmission rate using predetermined full retarded Green’s function, and then numerically examine the effect of the various parameters on the transmission coefficient and discuss the features and physical mechanism behind them in detail. On the basis of the optical responsivity we further extend our study to fast and slow light phenomenon. The results show that our proposed system can not only realize ultra-fast/ultra-slow light under proper choice of cavity parameters but also a realization of the conversion between fast and slow light and vice versa has also been pointed out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Arbuscular mycorrhizal fungal community responses to drought and nitrogen fertilization in switchgrass stands

Anthropogenic global change is increasing the severity and frequency of abiotic stresses such as drought that are likely to affect soil communities. Arbuscular mycorrhizal fungi (AMF) play important roles in many soil processes, so it is important to understand how drought affects AMF biodiversity. This is especially relevant in agricultural systems where crops rely on AMF associations for water and nutrient uptake, and where management decisions such as crop selection and fertilizer application may influence how the AMF community responds to drought. In this study, we examined the effects of reduced precipitation and nitrogen fertilization on AMF richness, community composition, and root and soil colonization in monocultures of two cultivars of switchgrass (Panicum virgatum) grown for bioenergy feedstock. We conducted a two-year field experiment using rain-out shelters to manipulate precipitation in mature stands of switchgrass growing in a long-term nitrogen fertilization (0 or 56 kg N ha –1 ) experiment at the W.K. Kellogg Biological Station Long-Term Ecological Research site in Michigan, USA. We expected that AMF richness and colonization would decrease due to drought, as predicted by the stress exclusion hypothesis. Contrary to our expectations, we found that drought stress increased AMF species richness in fertilized plots by 15%; there was no effect of drought on AMF richness in unfertilized plots. Drought also significantly altered AMF community composition, primarily due to increases in Rhizophagus taxa abundance, and reduced AMF root colonization in switchgrass by 6%. We also found variation in AMF richness and colonization across switchgrass cultivars as well as sampling dates. Furthermore, the changes in AMF richness and composition that we observed in this study may have implications for perennial bioenergy feedstock selection and management as changes in AMF communities may feedback to affect host plants.

54 ENVIRONMENTAL SCIENCES↗

High harmonic generation governed by edge states in triangular graphene quantum dots

Here, we study theoretically interaction of short optical pulses with triangular graphene quantum dots. If such quantum dots have zigzag edges then there are in-gap degenerate edge states, the number of which depends on the size of the system. We show that the nonlinear optical response, such as high harmonic generation, of triangular quantum dots is sensitive to the initial electron population of their edge states. In general, the emission spectra of quantum dots have weak dependence on the number of occupied edge states, but if half of the edge states are initially occupied, which can be realized only in the quantum dots with even number of edge states, then the even high harmonics are strongly suppressed. The suppression is the strongest when the frequency of the pulse is well below the band gap and it is weak when the pulse frequency becomes comparable to the band gap of the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of Theoretical Solutions to a Bottom-Raised Oscillating Surge Wave Energy Converter (OSWEC) Through Experimental and Parametric Studies

Experiments were conducted on a wave tank model of a bottom raised oscillating surge wave energy converter (OSWEC) model in regular waves. The OSWEC model shape was a thin rectangular flap, which was allowed to pitch in response to incident waves about a hinge located at the intersection of the flap and the top of the supporting foundation. Torsion springs were added to the hinge in order to position the pitch natural frequency at the center of the wave frequency range of the wave maker. The flap motion as well as the loads at the base of the foundation were measured. The OSWEC was modeled analytically using elliptic functions in order to obtain closed form expressions for added mass and radiation damping coefficients, along with the excitation force and torque. These formulations were derived and reported in a previous publication by the authors. While analytical predictions of the foundation loads agree very well with experiments, large discrepancies are seen in the pitch response close to resonance. These differences are analyzed by conducting a sensitivity study, in which system parameters, including damping and added mass values, are varied. The likely contributors to the differences between predictions and experiments are attributed to tank reflections, standing waves that can occur in long, narrow wave tanks, as well as the thin plate assumption employed in the analytical approach.

analytical↗

Random Phase Approximation Correlation Energy Using Real-Space Density Functional Perturbation Theory

We present a real-space method for computing the random phase approximation (RPA) correlation energy within Kohn–Sham density functional theory, leveraging the low-rank nature of the frequency-dependent density response operator. In particular, we employ a cubic-scaling formalism based on density functional perturbation theory that circumvents the calculation of the response function matrix, instead relying on the ability to compute its product with a vector through the solution of the associated Sternheimer linear systems. We develop a large-scale parallel implementation of this formalism using the subspace iteration method in conjunction with the spectral quadrature method while employing the Kronecker product-based method for the application of the Coulomb operator and the conjugate orthogonal conjugate gradient method for the solution of the linear systems. We demonstrate convergence with respect to key parameters and verify the method’s accuracy by comparing with plane-wave results. We show that the framework achieves good strong scaling to many thousands of processors, reducing the time to solution for a lithium hydride system with 128 electrons to around 150 s on 4608 processors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗