Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Update Direct-Strike Lightning Environment for Stockpile-to-Target Sequence (Second Revision)

The University of Florida has surveyed all relevant publications reporting lightning characteristics and presents here an up-to-date version of the direct-strike lightning environment specifications for nuclear weapons published in 1989 by R. J. Fisher and M. A. Uman. Further, we present functional expressions for current vs. time, current derivative vs. time, second current derivative vs. time, charge transfer vs. time, and action integral (specific energy) vs. time for positive and negative first return strokes, for negative subsequent return strokes, and for positive and negative continuing currents; and we give sets of constants for these functional expressions so that the resultant waveforms exhibit approximately the median and extreme lightning parameters presented in the updated direct strike environment. Fourier transforms of the return stroke current waveforms are presented. The results of our literature survey are included in three Appendices entitled Return Stroke Current, Continuing Current, and Positive Lightning.

42 ENGINEERING↗

Lightning Climatology Derived from World Wide Lightning Location Network (WWLLN) for US East Coast and European North Sea

This dataset contains gridded (1x1 km) data of lightning stroke observations during 2020, 2021, and 2022 over the US East Coast and European North Sea. Data processing involved intersecting each of the ~26 million lightning strokes over the US East Coast and ~365 thousand strokes over the North Sea within a corresponding 1x1 km grid, resulting in each grid reporting a 'strokes per square kilometer' and 'energy per square kilometer'. For the US, these results are presented as annual averages for 2020, 2021, and 2022, while for the North Sea results are presented as a 3-year annual average.

17 WIND ENERGY↗

Lightning Climatology Derived from World Wide Lightning Location Network (WWLLN) for US East Coast and European North Sea

This dataset contains gridded (1x1 km) data of lightning stroke observations during 2020, 2021, and 2022 over the US East Coast and European North Sea. Data processing involved intersecting each of the ~26 million lightning strokes over the US East Coast and ~365 thousand strokes over the North Sea within a corresponding 1x1 km grid, resulting in each grid reporting a 'strokes per square kilometer' and 'energy per square kilometer'. For the US, these results are presented as annual averages for 2020, 2021, and 2022, while for the North Sea results are presented as a 3-year annual average.

17 WIND ENERGY↗

The electric fields produced by lightning stepped leaders

The electric fields produced by stepped and dart-stepped leaders which immediately precede return strokes in lightning discharges to the ground have been recorded in Florida and Arizona. The mean interval time between normal steps is about 16 microsec, and the mean interval between dart steps is 6-8 microsec. The amplitudes of leader pulses in Florida increase just prior to the return stroke, the largest usually being about 10% of the return-stroke peak. In Arizona the leader pulse amplitudes are smaller than those in Florida, in relation to the return stroke, and are not as easy to identify. The shapes of the fields produced by normal steps are similar to dart steps, and the dart steps are very similar to regular sequences of pulses produced by many intracloud discharges. The 10-90% rise times of individual step wave forms are often less than 0.3 microsec, and the full width at half maximum of a step pulse is typically 0.4-0.5 microsec under conditions where the propagation distortion is minimal. The amplitudes and the shapes of leader step wave forms suggest that the peak step current is at least 2000-8000 A close to the ground and that the maximum rate of change of step current is 6-24 kA/microsec or larger. A rough estimate of the minimum charge lowered during the formation of a step is 0.001 to 0.004 C.

Krider, E. P.↗

Left ventricular function during lower body negative pressure

The response of the human left ventricle to lower body negative pressure (LBNP) and the relation between left ventricular function and hemodynamic response were investigated. Ventricular function curves relating stroke volume to end-diastolic volume were obtained in 12 normal men. Volume data were derived from echocardiographic measurements of left ventricular end-systolic and end-diastolic diameters at rest and during lower body negative pressure (LBNP) at minus 40 mm Hg. End-diastolic volume decreased by 19% and stroke volume by 22%. There were no significant changes in heart rate, arterial blood pressure, or end-systolic volume. Thus, moderate levels of LBNP significantly reduce preload and stroke volume without affecting contractile state. The absence of significant changes in heart rate and arterial blood pressure in the presence of a significant reduction in stroke volume is consistent with an increase in systemic peripheral resistance mediated by low-pressure baroreceptors.

Ahmad, M.↗

An unusual lightning flash at Kennedy Space Center

A lightning flash that struck the 150-meter weather tower at Kennedy Space Center was studied by several research groups using various techniques. The flash had unusually large peak currents and a stepped leader of relatively short duration. The charged regions neutralized by the three return strokes were located within a horizontal layer between heights of about 6 and 8 kilometers, where environmental temperatures were about -10 to -20 C. The charge source for the first return stroke coincided with a vertical shaft of precipitation inferred to have been graupel or hail. Charge sources for subsequent strokes were near the edge of the detectable precipitation echo. The overall channel length was about 10 kilometers. A vertically oriented intracloud discharge occurred after the three return strokes.

Uman, M. A.↗

Changes in cardiac output and tibial artery flow during and after progressive LBNP

A 3.0 MHz Pulsed Doppler velocity meter (PD) was used to determine blood velocities in the ascending aorta from the suprasternal notch before, during and after progressive 5 min stages of lower body negative pressure (LBNP) in 7 subjects. Changes in stroke volume were calculated from the systolic velocity integrals. A unique 20 MHz PD was used to estimate bloodflow in the posterior tibial artery. With -20 torr mean stroke volume fell 11% and then continued to decline by 48% before LBNP was terminated. Mean tibial flow fell progressively with LBNP stress, due to an increase in reverse flow component and a reduction in peak forward flow and diameter. Stroke volume increased and heart rate fell dramatically during the first 15 sec of recovery. The LBNP was terminated early in 2 subjects because of vasovagal symptons (V). During V the stroke volume rose 86% which more than compensated for the drop in heart rate. This implies that V is accompanied by a paradoxical increase in venous return and that the reduction in HR is the primary cardiovascular event. During the first 15 sec of recovery these 2 subjects had a distinctive marked rise to heart rate reminiscent of the Bainbridge reflex.

Source record↗

Kinematical and mechanical aspects of wafer slicing

Some recently achieved results concerning the technological fundamentals of slurry sawing are presented. The specific material removal process and the related kinematic and geometric contact conditions between workpiece and saw blade are described. The result of a functional description of the slurry sawing process is presented, expressing the main process criteria, such as infeed per stroke, specific removal rate, specific tool wear, and vertical stroke intensity, in terms of the dominating process parameters, such as stroke length, width of workpiece, stroke frequency, specific cutting force and slurry specification.

Werner, P. G.↗

Nighttime observations of thunderstorm electrical activity from a high altitude airplane

Photographs from a NASA U-2 airplane flying over nocturnal thunderstorms show frequent lightning activity in the upper part of the cloud. In some cases, unobscured segments of lightning channels 1 km or longer are visible in clear air around and above the cloud. Multiple images of lightning channels indicate multiple discharges in the same channel. Photographs taken through a diffraction grating show that the lightning has a spectrum similar to that observed in the lower troposphere. Lightning spectra obtained with a slitless line-scan spectrometer show strong singly ionized nitrogen emissions at 463.0 and 500.5 nm. Field changes measured with an electric field-change meter correlate with pulses measured with a photocell optical system. Optical signals corresponding to dart leader, return stroke, and continuing current events are readily distinguished in the scattered light emerging from the cloud surface. The variation of light intensity with time in lightning events is consistent with predicted modification of optical lightning signals by clouds. It appears that satellite based optical sensor measurements cannot provide reliable information on current rise times in return strokes. On the other hand, discrimination between cloud-to-ground and intracloud flashes and the counting of ground strokes is possible using the optical pulse pairs which have been identified with leader, return-stroke events in the cloud-to-ground flashes studied.

Brook, M.↗

Locating rocket triggered lightning using the LLP lightning locating system at the NASA Kennedy Space Center

Five rocket-triggered cloud-to-ground lightning flashes were detected by the operational lightning-locating system at the NASA Kennedy Space Center on August 17, 1984. The locating system, which was designed to detect natural lightning, detected at least 2 and as many as 6 strokes in the triggered flashes, suggesting that some of the strokes in the triggered lightning had signal-amplitude and waveshape characteristics similar to natural lightning. However, not all triggered strokes were detected, indicating that some strokes were atypical in nature. Since the ground-strike points of the triggered flashes were known quite precisely, the accuracy of the lightning-locating system was also evaluated. The three direction finders were found to have a mean bearing accuracy of + or - 0.5-0.6 deg. The distance errors of the real-time position solutions of the locating system on the triggered flashes were in the range of 195-770 m, with a mean of 480 m.

Maier, M. W.↗

The amplitude spectra of lightning radiation fields in the interval from 1 to 20 MHz

Amplitude spectra of the fast-rising initial portion of the EM fields produced by return strokes, leader steps, and cloud pulse are presented. These data have been derived from ground-based measurements of dE/dt signatures that were recorded in the time domain on a triggered oscilloscope. The spectral amplitudes of first return strokes match previously published data at 1 MHz and decrease with increasing frequency, as 1/f between 1 and about 6 MHz and as 1/f squared between 6 and 20 MHz. The spectral amplitudes of leader steps just before return strokes and the fast portion of cloud pulses that triggered the recording system tend to lie 5 to 10 dB below the amplitudes of first return strokes over the entire frequency interval.

Weidman, C. D.↗

Multistroke cloud-to-ground strike to the NASA F-106B airplane

An analysis of electromagnetic waveform records and video images of a multistroke cloud-to-ground (CG) strike to the NASA F-106B instrumented airplane is presented. The CG flash started as a lightning strike triggered by the airplane and later produced multiple return strokes to the ground (the ground strike network registered six return strokes). Although there are some uncertainties in data interpretation resulting from lack of independent measurements with other than the airborne instruments, recoil streamers and eight sequences of dart leaders followed by return strokes (two more than were indicated by the ground network) were identified in the airborne data. At least three of the subsequent return strokes were attached to the airplane. The analysis provides evidence that formation of recoil streamers and dart leaders is accompanied by a surge in continuous current. This feature is similar to that observed in the bidirectional leader development during lightning initiation on the airplane.

Mazur, Vladislav↗

Launch pad lightning protection effectiveness

Using the striking distance theory that lightning leaders will strike the nearest grounded point on their last jump to earth corresponding to the striking distance, the probability of striking a point on a structure in the presence of other points can be estimated. The lightning strokes are divided into deciles having an average peak current and striking distance. The striking distances are used as radii from the points to generate windows of approach through which the leader must pass to reach a designated point. The projections of the windows on a horizontal plane as they are rotated through all possible angles of approach define an area that can be multiplied by the decile stroke density to arrive at the probability of strokes with the window average striking distance. The sum of all decile probabilities gives the cumulative probability for all strokes. The techniques can be applied to NASA-Kennedy launch pad structures to estimate the lightning protection effectiveness for the crane, gaseous oxygen vent arm, and other points. Streamers from sharp points on the structure provide protection for surfaces having large radii of curvature. The effects of nearby structures can also be estimated.

Stahmann, James R.↗

Observations of lightning processes using VHF radio interferometry

A single station, multiple baseline radio interferometer was used to locate the direction of VHF radiation from lightning discharges with microsec time resolution. Radiation source directions and electric field waveforms were analyzed for various types of breakdown events. These include initial breakdown and K type events of in-cloud activity, and the leaders of initial and subsequent strokes to ground and activity during and following return strokes. Radiation during the initial breakdown of a flash and in the early stages of initial leaders to ground is found to be similar. In both instances, the activity consists of localized bursts of radiation that are intense and slow moving. Motion within a given burst is unresolved by the interferometer. Radiation from in-cloud K type events is essentially the same as that from dart leaders; in both cases it is produced at the leading edge of a fast moving streamer that propagates along a well defined, often extensive path. K type events are sometimes terminated by fast field changes that are similar to the return stroke initiated by dart leaders; such K type events are the in-cloud analog of the dart leader return stroke process.

Rhodes, C. T.↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The investigation of cardiovascular adaptation to space flight has seen substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented an initial increase, followed by a progressive reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been identified. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a Get Away Special (GAS) payload within the next year.

Pantalos, George M.↗