Geospatial Data Platform for All

Spatiotemporal data has evolved in scale due to augmented use in cross-domain applications. Simultaneously, there is substantial growth in the availability of Geographic Information Systems (GIS) data provided by the United States Geological Survey (USGS) along with other federal, state, county, or local agencies through open-data portals and public access APIs. However, data availability does not equate with accessibility. Large-scale analyses and applications require robust, performant data management with co-location of data storage and computing. The insufficiency of data management infrastructure compels researchers to adopt ad hoc project- specific GIS data storage solutions (e.g., copying data to High-Performance computer file systems). As an ad hoc storage strategy does not scale, it hampers cross-domain analyses causing difficulty in data reuse and utilizing existing code bases. Furthermore, GIS data is complex and requires expertise to analyze and manipulate due to its intricate data structures and data-specific projection transformations. Despite the challenges, we recognize that derived GIS data products, e.g., satellite or LIDAR-based images, can be used in downstream applications such as AI by domain, but non-GIS experts. To address the data needs and overcome the challenges, we are working towards a GIS Data Platform focused on efficient data storage, data discovery and access, and an API to enable common workflows. We propose a knowledge-graph (KG) approach for data discovery, whereby datasets are semantically linked to higher- level constructs such as projects and research areas. The semantic data links enable researchers to explore datasets in a top-down approach by specifying relevant and meaningful terms (assists in finding hidden data). An advantage is that the nodes and edges in a knowledge graph create built-in semantic documentation. Deeper spatiotemporal connections between data sources can be encoded via Graph Neural Networks (GNN) (Zhang et al., 2021). The KG approach can be extended to integrate the data itself in a Virtual KG (VKG). Our work will derive inspiration from large-scale VKG efforts that have been undertaken or are currently underway as part of the OpenStreetMap project (Ding et al., 2021). For DOE Data Days, we share the proposed geospatial data platform hybrid (cloud/on-prem) architecture, our work-to-date on storing, retrieving, and transforming LiDAR and raster data relevant to two important NREL use-cases, including the Renewable Energy Potential (reV) Model, and present our proposal for a KG based data discovery engine.

data platform↗

Active Seismoelectric Monitoring of CO 2 Injection

Conference presentation at Carbon Capture, Utilization, and Storage (CCUS) Conference 2024, Houston, Texas, March 11–13, 2024. We investigated the use of active seismoelectric monitoring (ASE) to determine its effectiveness in detecting CO 2 injected deep underground and as an additional monitoring option for carbon storage projects. The EERC performed an ASE survey in February of 2023 at Pennel oil field near Baker, Montana, as part of the U.S. Department of Energy-sponsored Williston Basin CO 2 Field Laboratory in conjunction with operating partner Denbury Inc. The field site is part of the Cedar Creek Anticline geologic structure, with CO 2 planned for injection into a stacked storage complex (SSC) in the Interlake Formation containing both a residual oil zone and a conventional reservoir. The objective was to test the ASE method’s ability to characterize baseline fluid distribution in both the near surface and the SSC prior to CO 2 injection.

04 OIL SHALES AND TAR SANDS↗

Prefeasibility Assessment for Solar PV and Storage for Critical Community Facilities in Chernihiv, Ukraine [Slides]

A prefeasibility analysis is performed for integrating solar photovoltaics and battery energy storage at four critical facilities in Chernihiv, Ukraine. The facilities were identified by Chernihiv city officials and include Hospital No. 2, the Maternity Hospital, Secondary School No. 11, and Preschool No. 4. The analyses were performed using NREL's REopt decision-support software tool. The analysis identifies potential capacities for PV and battery energy storage to provide both economic and resilience benefits. The conceptual architecture and estimates of key summary financial and performance metrics are presented.

14 SOLAR ENERGY↗

Joint Optimization of Well Completions and Controls for CO 2 Enhanced Oil Recovery and Storage

CO 2 storage through CO 2 enhanced oil recovery (EOR) is considered as one of the technologies to help promote larger scale deployment of CO 2 storage because of associated economic benefits through oil recovery, 45Q tax credits and the utilization of existing infrastructure. The objective of this study is to demonstrate how optimal reservoir management and operation strategies (including well completions and controls) can be used to optimize both CO 2 storage and oil recovery. The optimization problem was focused on jointly estimating the well completions (i.e., fraction of injection/production well perforations in each reservoir layer) and CO 2 injection/oil production controls that maximize the net present value (NPV) in a CO 2 EOR and storage operation. We utilized the newly developed StoSAG algorithm, one of the most efficient optimization algorithms in the reservoir management community, to solve the optimization problem. The performance of joint optimization approach was compared with the performance of well control only optimization approach. In addition, the performance of co-optimization of CO 2 storage and oil recovery approach was compared with the performances of maximization of only CO 2 storage and maximization of only oil recovery approaches. The optimization results showed that a joint optimization of well completions and well controls can achieve an 8.84% higher final NPV than the one obtained from the optimization of only well controls. It was observed that the NPV incremental for joint optimization is mainly due to the fact that the optimal well completions and controls approach results in efficient CO 2 storage and oil production from different reservoir layers depending on the differences in individual layer properties. Comparison of co-optimization (i.e., maximization of NPV) and maximization of only CO 2 storage or only oil recovery showed that the co-optimization and maximization of only oil recovery result in significantly higher final NPV than that obtained through maximization of only CO 2 storage approach while maximization of only CO 2 storage can achieve significantly higher CO 2 storage in the reservoir compared to the other two scenarios. The similar results for co-optimization and maximization of oil production are obtained because of the difference in oil revenue compared to CO 2 storage tax credit. To the best of our knowledge, this is the first study in oil/gas industry and CO 2 storage community to perform joint optimization of well completions and well controls in the fields. We expect that the proposed optimization framework will be a useful and efficient tool for field engineers to optimally manage CO 2 EOR projects to maximize revenue through oil recovery as well as CO 2 storage by taking advantage of the new 45Q tax law.

Artificial intelligence↗

Enabling Deformable and Stretchable Batteries

Abstract Deformable energy storage devices are needed to power next‐generation wearable electronics that interface intimately with human skin. Currently, deformable energy storage devices demonstrate poor performance compared to their rigid lithium‐ion counterparts, forcing wearable manufacturers to design their devices around bulky battery compartments. However, technological advances to create deformable batteries at the component and device level have yielded continuous improvement in stretchable batteries over the last five years. In this Essay, the major strategies at the component and device level that have been successfully employed to create stretchable batteries are reviewed. The outstanding challenges facing deformable energy storage are also discussed, namely, energy density, packaging, delamination, device integration, and manufacturing. This Essay will give researchers who are interested in contributing to the development of deformable batteries a cursory understanding of the most successful strategies to date, and provide insights into the most important directions to pursue in the future.

Mackanic, David G.↗

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis↗

Register-Like Storage Block Used as Histograms, Cluster Buffers, and Hough Transform Accumulators for HEP Trigger Systems

In high energy physics experiment trigger systems, block memories are utilized for various purposes, especially in binned searching algorithms. In these algorithms, the storages are demanded to perform like a large set of registers. The writing and reading operation must be performed in single clock cycle and once an event is processed, the memory must be globally reset. These demands can be fulfilled with registers but the cost of using registers for large memory is unaffordable. Another common requirement is the boundary coverage feature during reading process. Additionally, when a memory bin is addressed, the stored contents in the addressed bin and its neighboring bin must be output simultaneously. In this paper, a register-like block storage design scheme is described, which allows updating memory locations in single clock cycle, reading two adjacent bins, and effectively refreshing entire memory within a single clock. The implementation and test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Carbon Nanotubes: Applications to Energy Storage Devices

Carbon nanotubes (CNTs) are an extraordinary discovery in the area of science and technology. Engineering them properly holds the promise of opening new avenues for future development of many other materials for diverse applications. Carbon nanotubes have open structure and enriched chirality, which enable improvements the properties and performances of other materials when CNTs are incorporated in them. Energy storage systems have been using carbon nanotubes either as an additive to improve electronic conductivity of cathode materials or as an active anode component depending upon structural and morphological specifications. Furthermore, they have also been used directly as the electrode material in supercapacitors and fuel cells. Therefore, CNTs demand a huge importance due to their underlying properties and prospective applications in the energy storage research fields. There are different kinds of carbon nanotubes which have been successfully used in batteries, supercapacitors, fuel cells and other energy storage systems. This chapter focuses on the role of CNTs in the different energy storage and conversion systems and impact of their structure and morphology on the electrochemical performances and storage mechanisms.

Amin, Ruhul↗

Storage Futures Study: Storage Technology Modeling Input Data Report

The Storage Futures Study (SFS) is a multiyear research project to explore the role and impact of energy storage in the evolving electricity sector of the United States. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This specific report synthesizes current and projected cost performance assumptions along with location availability for storage technologies through 2050 that will be used in scenario analysis for the SFS at both the bulk power and distribution system scales. For comparison and context, this report also presents a synthesis of current cost and performance characteristics of energy storage technologies for storage durations ranging from minutes to months and including mechanical, thermal, and electrochemical storage technologies for the electricity sector. This information is intended to cover a broad range of storage technologies that are currently receiving significant attention from the investment community as well as in the media. In the report, we emphasize that energy storage technologies must be described in terms of both their power (kilowatts [kW]) capacity and energy (kilowatt-hours [kWh]) capacity to assess their costs and potential use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Zigzag flow reactor for weekly thermochemical energy storage

This paper describes theoretical models and experimental performance of a novel Zigzag Flow Reactor (ZFR) for weekly thermochemical energy storage. The ZFR reduces redox-active metal oxide (MO x ) particles at high temperature (up to ~1100 °C) under inert gas sweep. A physical model demonstrates the approach to process equilibrium by minimizing the associated exergy destruction in a finite number of reaction steps, establishing the thermodynamic requirements for a practical reactor. The model results show several cost-relevant parameter tradeoffs, and the tradeoff analysis implies a cost-optimized set of boundary conditions. Numerical models and prototypes show that the ZFR enables significant gas phase homogenization while simultaneously enabling a customizable MO x residence time in the reactor, both key requirements for approaching an equilibrium process. A scaling model demonstrates the simplicity and affordability of sizing the ZFR to grid-scale levels, with fabrication costs at least five times lower than previously proposed scalable reactor concepts. As a result, a laboratory ZFR prototype achieved an energy storage density of ~90 Wh/kg with CaAl 0.2 Mn 0.8 O 3-δ as the MO x , at temperatures of ~850 °C in >10 h of total runtime.

Thermochemical energy storage↗

Integration of a Wigner effect-based energy storage system with an advanced nuclear reactor

In this work, an innovative energy storage concept based on the purposeful creation of defects in crystalline material by neutron irradiation is presented. Lattice defects are generated when heavy particles collide with the atoms in a crystal structure, i.e., if the incoming particles have enough energy, recoil atoms are displaced from their initial lattice sites. Most of the displaced atoms will eventually combine with nearby vacancies, but some of them will come to rest in non-ideal locations. The energy held by displaced atoms is called Wigner energy. Lattice defects can migrate and form clusters, and the Wigner energy can be released from these groupings if sufficient activation energy is provided. In the nuclear industry, this effect is well-known since it represented an issue for graphite-moderated reactors. This work presents the conceptual design of an engineering system that exploits this physical process to store the energy of neutrons in advanced reactor concepts. In the first part of the paper, the theoretical performance of an energy storage system based on the Wigner effect is described. Given the lattice properties and the compatibility with the harsh reactor environment, graphite was selected as the candidate material for the irradiation targets. Both experimental data and molecular dynamics simulations confirmed that this system can achieve performance comparable with state-of-the-art batteries in terms of stored energy density. In the second part of the paper, the engineering challenges of this innovative technology and the proposed solutions are described. After defining the optimal irradiation conditions, the different steps of the operation of the proposed energy system (from energy storing to energy harvesting) were defined. Finally, the integration of this concept with advanced reactor designs, i.e., a Sodium-cooled Fast Reactor and a Molten Salt-cooled Reactor, was investigated and the corresponding performance was evaluated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Identification of Dopant Occupation in Li‐Rich Cathodes

Elemental doping is widely used to improve the performance of cathode materials in lithium‐ion batteries. However, macroscopic/statistical investigation on how doping sites are distributed in the material lattice, despite being a key prerequisite for understanding and manipulating the doping effect, has not been effectively established. Herein, to solve this predicament, a universal strategy is proposed to quantitatively identify the locations of Al and Mg dopants in lithium‐rich layered oxides (LLOs). Solid evidence confirms that Al prefers to occupy the transition metal (TM) layer, while Mg evenly occupies both TM and Li layers. As a result, Mg significantly reduces the thickness of LiO 2 slabs at room temperature, which will increase the energy barrier of oxygen activation and enhance the structure stability of LLOs. The suppressed oxygen activity in Mg‐doped LLO can be kinetically unlocked at 55 °C. The different characteristics of Al and Mg enlighten an Al/Mg co‐doping strategy to optimize LLOs, which significantly improves the cycle performance while lifting the capacity. In conclusion, these insights from the quantitative identification of doping sites shed light on the manipulation of doping effects toward better cathodes.

25 ENERGY STORAGE↗

Supercapacitor-Based Power Resilience Solutions for Modern Grids, Microgrids, and Facilities

This report summarizes the tests and results of a supercapacitor based energy storage system demonstration project performed in collaboration with Capacitech Energy, Orlando Utilities Commission and Sandia National Labs. This project evaluated a 3.6 farad (F), 720 V rated supercapacitor system in a microgrid environment to study three primary use cases: black start, voltage regulation, and load leveling, and successfully demonstrated the performance for the use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DE-FE0029488 - North Dakota Integrated Carbon Capture and Storage Complex Feasibility Study Public Data

Data from award DE-FE0029488 - North Dakota Integrated Carbon Capture and Storage Complex Feasibility Study performed by the Energy & Environmental Research Center including the following: - 2D Seismic {Input data, sgy files, maps, logs, and descriptors} - Core Petrophysics {Core analysis of plugs from the two stratigraphic test wells (Flemmer-1 [API 33-057-00039] and BNI-1 [API 33-065-00018])} - North Dakota Oil and Gas File No 37380 Files - North Dakota Oil and Gas File No 37672 Files - Well Testing Data {Summary of well testing methods and results from the stratigraphic test wells (Flemmer-1 and BNI-1)} Additional References: https://www.netl.doe.gov/sites/default/files/2017-12/Wesley-Peck-_Mastering-the-Subsurface_CarbonSAFE-Phase-II_August-2017-final.pdf Peck, W.D., Ayash, S.C., Klapperich, R.J., Gorecki, C.D. (2019) The North Dakota integrated carbon storage complex feasibility study, International Journal of Greenhouse Gas Control, Volume 84, 2019, Pages 47-53, https://doi.org/10.1016/j.ijggc.2019.03.001

Carbon Storage↗

Model 9975 O Ring Fixture Long-Term Leak Performance (FY2024 Status Report)

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months of testing while fixture #18 remained leak tight. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F.