AWAKEN Site C1 UTD Surface Met Station / Reviewed Data
This dataset contains reviewed data from the AWAKEN Site C1 UTD Surface Met Station.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This dataset contains reviewed data from the AWAKEN Site C1 UTD Surface Met Station.
This dataset contains raw data from the WFIP3 RHOD site supplementary meteorological sensors: T/RH and barometer; 1-sec average. The supplementary meteorological suite was added to PNNL Surface Flux Station to provide independent measurements of air temperature, relative humidity, and atmospheric pressure.
This dataset contains raw data from the WFIP3 RHOD site supplementary meteorological sensors: T/RH and barometer; 1-sec average. The supplementary meteorological suite was added to PNNL Surface Flux Station to provide independent measurements of air temperature, relative humidity, and atmospheric pressure.
Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.
Abstract. Riming of ice crystals by supercooled water droplets is an efficient ice growth process, but its basic properties are still poorly known. While it has been shown to contribute significantly to surface precipitation at mid-latitudes, little is known about its occurrence at high latitudes. In Antarctica, two competing effects can influence the occurrence of riming: (i) the scarcity of supercooled liquid water clouds due to the extremely low tropospheric temperatures and (ii) the low aerosol concentration, which may lead to the formation of fewer and larger supercooled drops potentially resulting in an enhanced riming efficiency. In this work, by exploiting the deployment of an unprecedented number of multiwavelength remote sensing systems (including triple-frequency radar measurements) in West Antarctica, during the Atmospheric Radiation Measurements West Antarctic Radiation Experiment (AWARE) field campaign, we evaluate the riming incidence at McMurdo Station and find that riming occurs at much lower temperatures when compared to previous results in the mid-latitudes. This suggests the possible occurrence of a common atmospheric state over Antarctica that includes a rather stable atmosphere inhibiting turbulent mixing, and a high riming efficiency driven by large cloud droplets. We then focus on a peculiar case study featuring a persistent layer with a particularly pronounced riming signature in triple-frequency radar data but only a relatively modest amount of supercooled liquid water. In-depth analysis of the radar observations suggests that such signatures can only be explained by the combined effects of moderately rimed aggregates or similarly shaped florid polycrystals and a narrow particle size distribution (PSD). Simulations of this case study performed with a one-dimensional bin model indicate that similar triple-frequency radar observations can be reproduced when narrow PSDs are simulated. Such narrow PSDs can in turn be explained by two key factors: (i) the presence of a shallow homogeneous droplet or humidified aerosol freezing layer aloft seeding an underlying supercooled liquid layer, and (ii) the absence of turbulent mixing throughout a stable polar atmosphere that sustains narrow PSDs, as hydrometeors grow from the nucleation region aloft to ice particles of several millimeters in size, by vapor deposition and then riming.
The Solar Uncertainty Integrator (SUNI) study was developed by the National Laboratory of the Rockies (NLR's) to provide a standardized "bulk uncertainty processing" method for solar irradiance data, which are essential for the successful deployment of solar energy systems. This poster provides an overview of key findings from NLR's SUNI application across 89 stations.
The Stations Tool for Automated Permitting (S-TAP) is a spreadsheet-based plan review questionnaire designed to help automate and expedite the electric vehicle supply equipment (EVSE) permitting process. This manual goes into detail on the development of the tool and guidance for use cases of the tool.
This dataset includes yearlong, one-minute resolution time series profiles for the big box retail grocery stores stores simulated in Phoenix, Houston, Denver, and Minneapolis, as well as electric vehicle charging time series profiles for the various ports, charging levels, and station utilizations produced for the study "Impact of electric vehicle charging on the power demand of retail buildings", published in 2021 (https://doi.org/10.1016/j.adapen.2021.100062). Please cite as: Gilleran, M., Bonnema, E., Woods, J. et al. Impact of electric vehicle charging on the power demand of retail buildings. Advances in Applied Energy 4, (2021). https://doi.org/10.1016/j.adapen.2021.100062
This dataset contains the code and data files needed for implementation of a Multivariate Bayesian Regression model, described in Jin et al. (2025), for the historical prediction of the chemical composition of disposed coal ash at U.S. coal fired power plants as a function of annualized coal purchase data. The integrated coal supply data file (CoalSupplyDataset.csv) represents a compilation of monthly fuel purchase records for the period 1973-2022 at major U.S. power stations. These records were obtained from the U.S. Energy Information Administration. The CSV file also contains, for each coal purchase record, the coal region of the mine as defined by the U.S. Geological Survey. Data entry errors and data gaps in the EIA records were corrected as described in Jin et al. This CSV file represents the integrated coal supply data after corrections were made. The model structure and fitting parameters are encoded in pickle file format (Bayesian.pkl). The model was developed with the coal supply data and coal ash composition data, apportioned according to the Stratified Shuffle Split for training and testing subsets. The model was built using Python and the PyMC library. Reference Publication: Jin, Z.; Huang, J.; Hower, J.C.; Hsu-Kim, H.(2025). Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites. Environmental Science & Technology.
High-throughput amplicon sequencing of the ITS, 16S and 18S regions from soil, roots and leaves DNAs of the 50 plots present in the BCSE (Biofuel Cropping System Experiment) experiment at Kellogg Biological Station.
Integrated Geologic Storage Prefeasibility Study proximal to Dry Fork Power Station, Powder River Basin, Wyoming
Energy infrastructure is a pivotal lifeline with wider inter-dependencies. Electric power is essential to the continued functioning of critical assets; liquid fuels and other physical primary energy commodities that are used to supply the local energy needs of these assets during extreme events when electricity infrastructure is compromised. During Superstorm Sandy, the disruption of fuel supplies in the Tri-state area necessitated increasing situational awareness about oil and natural gas (ONG) systems to redirect fuel supplies to first responders and for restoration efforts. During winter storm events over the past several years, the demand for ONG for heating and power generation has skyrocketed in the north-east, which subsequently had caused ONG price to hit their highest level in years. ONG is a major energy source for restoration and recovery activities. However, very little, if any, situational awareness information about ONG supply and demand is available to those coordinating emergency efforts. Often this lack of information is due to the decentralized nature of the ONG supply chain and proprietary data maintained by private entities. To understand the impact of fuel availability on response and recovery efforts, this research focuses on (i) determining the accessibility to gas stations for liquid fuel supply across space and time, and (ii) examining the spatio-temporal variation of fuel availability and demand during extreme weather events. The broader scope of the project focuses on providing spatio-temporal situational awareness information about ONG availability and demand across the fuel supply chain for positioning of resources for response activities.
A “black box” space vehicle solution may allow a payload developer to define the mission space and provide mission hardware within a predetermined volume and with predetermined connectivity. Components such as the power module, radios and boards, attitude determination and control system (ADCS), command and data handling (C&DH), etc. may all be provided as part of a “stock” (i.e., core) space vehicle. The payload provided by the payload developer may be plugged into the space vehicle payload section, tested, and launched without custom development of core space vehicle components by the payload developer. A docking station may facilitate convenient development and testing of the space vehicle while reducing handling thereof.
This case study highlights the strategies the Minnesota Department of Transportation used at Cedar Avenue Truck Station for integrating plug load and lighting systems. An integrated controls pilot project with retrofit installation was conducted from October 2019 to April 2020 and was recognized by DOE's Integrated Lighting Campaign.
In this short technical report, we explore the range of levelized costs of dispensed hydrogen (H2) from hydrogen refueling (or fueling) stations (HRS) for H2 heavy-duty fuel cell electric vehicles (FCEVs) that are feasible in the 2030 timeframe. We explore different scenarios by varying hydrogen delivery distances, HRS sizes, HRS utilization rates, and economies of scale in the Hydrogen Delivery Scenario Analysis Model (HDSAM). Thus, we observe how the contribution to the levelized cost of each supply chain component changes.
The increasing integration of Inverter-Based Resources (IBRs) into the system has brought significant focus on their role in blackstart and restoration procedures. Their advantageous features, such as low startup power requirements, operational flexibility across a wide range of power factors, rapid controllability, and the ability to energize a network at lower voltage levels necessitate a reassessment of existing restoration protocols. This paper seeks to showcase how IBRs can utilize their grid-forming capabilities to provide power to a remote generating station through detailed EMT simulation studies using data collected from an existing portion of a network.
Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.
Not Available