Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometers imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Application of imaging spectrometer data to the Kings-Kaweah ophiolite melange

The Kings-Kaweah ophiolite melange in east-central California is thought to be an obducted oceanic fracture zone and provides the rare opportunity to examine in detail the complex nature of this type of terrain. It is anticipated that the distribution and abundance of components in the melange can be used to determine the relative importance of geologic processes responsible for the formation of fracture zone crust. Laboratory reflectance spectra of field samples indicate that the melange components have distinct, diagnostic absorptions at visible to near-infrared wavelengths. The spatial and spectral resolution of AVIRIS is ideally suited for addressing important scientific questions concerning the Kings-Kaweah ophiolite melange and fracture zones in general.

Mustard, John F.↗

In-flight radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations (pre- and post-season of flight) for a uniform highly reflecting natural dry lake target. For one spectrometer (C), the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. This positive result validates the field and laboratory calibration technique. Results for the other spectrometers (A, B and D) were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.↗

HIRIS: NASA's high-resolution imaging spectrometer for the Earth Observing System (EOS)

The HIRIS design includes 10 nm spectral bands from 0.4 to 2.5 micron at 30 m spatial resolution over a 24 or 30 km swath. This resolution allows identification of many minerals in rocks and soils, important algal pigments in oceans and inland water and spectral changes in land canopy. In the 824 km orbit altitude proposed, the cross track pointing capability allows 4 to 5 views during a 16 day revisit cycle.

Dozier, J.↗

A system overview of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The AVIRIS instrument has been designed to do high spectral resolution remote sensing of the earth. Utilizing both silicon and indium antimonide line array detectors, AVIRIS covers the spectral region from 0.41 to 2.45 microns in 10-nm bands. It was designed to fly aboard NASA's U-2 and ER-2 aircraft, where it will simulate the performance of future spacecraft instrumentation. Flying at an altitude of 20 km, it has an instantaneous field of view of 20 m and views a swath over 10 km wide. With an ability to record 40 minutes of data, it can, during a single flight, capture 500 km of flight line.

Porter, Wallace M.↗

Signal chain for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The AVIRIS instrument has a separate dedicated analog signal processing chain for each of its four spectrometers. The signal chains amplify low-level focal-plane line array signals (5 to 10 mV full-scale span) in the presence of larger multiplexing signals (approx 150 mV) providing the data handling system a ten-bit digital word (for each spectrometer) each 1.3 microns. This signal chain provides automatic correction for the line array dark signal nonuniformity (which can approach the full-scale signal span).

Bunn, James S., Jr.↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Airborne imaging spectrometer-2 - Radiometric spectral characteristics and comparison of ways to compensate for the atmosphere

The reduction of AIS data to spectral radiance utilizing the detector responsivity equations developed by a laboratory calibration of the instrument with a BaSO4-coated integrating sphere is described. Estimates of the signal-to-noise ratio for laboratory and flight conditions are obtained. In addition, the effective in-flight instrumental spectral sampling interval is estimated by using atmospheric CO2 absorption lines generated from LOWTRAN simulations.

Conel, James E.↗

Data processing assessment for the Lunar Geoscience Observer imaging spectrometer

On the Lunar Geoscience Observer project, a Visible and Infrared Mapping Spectrometer instrument has been proposed. This instrument will have science data input rates in the hundreds of kilobits per second (kbps) and an average telemetry output data rate of 4 kbps. Techniques that can be used to reduce the throughput of the instrument are editing, summing and averaging, data compression, data preprocessing, pattern recognition and snapshot data taking. Due to instrument limitations in the buffer memory size and processing speeds, a careful selection of the available techniques must be made.

Irigoyen, R. E.↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of AVIRIS are described together with changes in instrument characteristics that occurred during the flight season. These changes include detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. Means of improving the instrument are discussed.

Vane, Gregg↗

In-flight radiometric calibration of the airborne visible/infrared imaging spectrometer (AVIRIS)

A reflectance-based method was used to provide an analysis of the in-flight radiometric performance of AVIRIS. Field spectral reflectance measurements of the surface and extinction measurements of the atmosphere using solar radiation were used as input to atmospheric radiative transfer calculations. Five separate codes were used in the analysis. Four include multiple scattering, and the computed radiances from these for flight conditions were in good agreement. Code-generated radiances were compared with AVIRIS-predicted radiances based on two laboratory calibrations for a uniform highly reflecting natural dry lake target. For one spectrometer, the pre- and post-season calibration factors were found to give identical results, and to be in agreement with the atmospheric models that include multiple scattering. Results for the other spectrometers were widely at variance with the models no matter which calibration factors were used. Potential causes of these discrepancies are discussed.

Conel, James E.↗

Optical neural net for classifying imaging spectrometer data

The problem of determining the composition of an unknown input mixture from its measured spectrum, given the spectra of a number of elements, is studied. The Hopfield minimization procedure was used to express the determination of the compositions as a problem suitable for solution by neural nets. A mathematical description of the problem was developed and used as a basis for a neural network solution and an optical implementation.

Barnard, Etienne↗

Search for soft X-ray emission from SN 1987A with a CCD X-ray imaging spectrometer

The results of soft X-ray observations of SN 1987A over the energy band 0.65-2.0 keV are reported. The upper limits on the soft X-ray flux are inconsistent with an extrapolation of the spectrum measured by the Ginga Satellite to the energy band and require a turnover in the X-ray spectrum between 2 and 4 keV. If this turnover is due to absorption by intervening material, a neutral column density associated with the supernova of at least 2.8 x 10 to the 21st/sq cm is required. The background rate for the Texas Instruments 800 x 800 pixel CCD, measured between 150 and 285 km altitude, was 1.1 counts/sq cm s. The background spectrum has a broad peak at 350 electrons, corresponding to charge deposited in the detector by minimally ionizing particles.

Burrows, D. N.↗

Optical alignment of a pupil imaging spectrometer

The GOES Sounder is a 19-channel discrete filter spectrometer with an additional channel for star sensing. This paper presents the GOES Sounder's instrument optics and compensations, alignment rationale, and alignment mechanism and sensitivities. The results of a line of sight tolerance analysis of the instrument are described, and the prealignment and instrument coregistration are addressed.

Horchem, Stephen D.↗

Evolution of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) flight and ground data processing system

The modifications made to both the AVIRIS instrument and the data processing facility since the instrument made its initial flight in the summer of 1987 are described. Historical development of the data system is discussed and attention is given to enhancements to instrument stability and noise performance. AVIRIS data facility objectives include rapid and automated decommutation and archiving of data, the ability to assess the quality of the data and health of the instrument, and the provision of an automated procedure for applying radiometric corrections to the data and providing responsive processing of data requests from investigators. The modifications described have resulted in an overall radiometric stability of better than 10 percent, with stability of only a few percent during a single flight.

Porter, Wallace M.↗

In-flight validation and calibration of the spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Through an in-flight calibration experiment at Rogers Dry Lake, California on September 20, 1989, the radiometric and spectral properties of AVIRIS were determined. In-flight spectral channel positions and the spectral response function in 10 regions of the AVIRIS spectral range, taking in all four spectrometers, are shown to agree closely with the corresponding parameters measured in the laboratory. The intraflight stability for the Rogers Dry Lake calibration site is better than 2 percent with the exception of the strong atmospheric water absorptions where the measured radiance is close to zero. This experiment has provided both direct generation of an in-flight spectral and radiometric calibration and validation of the laboratory calibration at the reported level accuracy.

Green, Robert O.↗

Moderate Resolution Imaging Spectrometer (MODIS) for the NASA Earth Observing System (EOS)

MODIS is intended to provide daily global surveys for the oceans, the atmosphere, and land. To achieve this capability, this instrument requires at least a 1700 km swath width and provides geometric-instantaneous-fields-of-view that are either 214 m, 428 m, or 856 m in size with reference to a 705 km satellite altitude. The range of products to be supported by MODIS includes ocean chlorophyll concentration, ocean primary productivity, dissolved organic matter in the oceans, global SST, total suspended solids, land cover type, land surface temperatures, vegetation indices, and volcanic and fire events. Details of the MODIS-N and MODIS-T instrument concepts are discussed.

Thompson, Leslie L.↗