Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Expanding the Energy Range from eV to MeV and Fabrication of Sources Enabling Novel Focused Ion Beam Nanofabrication and Modification

Multi-species focused ion beam (FIB) has the capability of running a variety of ion species allowing tailoring of the ion to the application enabling new applications of FIB such as localized doping and the creation of single defect centers. Also, through variation of the ion energy from eV to MeV, specific depths within the sample can be targeted enabling targeting of deeply buried layers inaccessible by traditional FIB systems. The combination of these capabilities opens up new areas of study including quantum information science and 2D materials.

47 OTHER INSTRUMENTATION↗

ANS hard X-ray experiment development program

The hard X-ray (HXX) experiment is one of three experiments included in the Dutch Astronomical Netherlands Satellite, which was launched into orbit on 30 August 1974. The overall objective of the HXX experiment is the detailed study of the emission from known X-ray sources over the energy range 1.5-30keV. The instrument is capable of the following measurements: (1) spectral content over the full energy range with an energy resolution of approximately 20% and time resolution down to 4 seconds; (2) source time variability down to 4 milliseconds; (3) silicon emission lines at 1.86 and 2.00keV; (4) source location to a limit of one arc minute in ecliptic latitude; and (5) spatial structure with angular resolution of the arc minutes. Scientific aspects of experiment, engineering design and implementation of the experiment, and program history are included.

Parsignault, D.↗

Variation of Lunar Sodium During Passage of the Moon through the Earth's Magnetotail

We measured sodium emission above the lunar equator over a range of lunar altitudes from 100 to 4000 km. The measurements were repeated approximately every 24 hours from June 7 to 16, 1998, covering the period during which the Moon passed through the Earth's magnetotail. Sodium temperatures derived from the altitude dependence of emission intensity ranged from 1200 to 2900 K. This result supports the view that photodesorption is a primary source of sodium in the exosphere since the most probable temperature of sodium form this source is in this range. Passage of the Moon through the Earth's magnetotail (where solar wind is essentially absent) affected the sodium density, such that it was higher before the Moon entered the Earth's magnetotail than after the Moon left it. This suggests that the solar wind plays a role in production of lunar sodium. We propose that its function is to mobilize sodium and bring it to the surface, where photodesorption can eject it into the exosphere. A two-step process such as this could help to explain the latitude dependence of sodium density, which varies as the second or higher power of cosine latitude.

Potter, Andrew E.↗

Comparison of a Convected Helmholtz and Euler Model for Impedance Eduction in Flow

Impedances educed from a well-tested convected Helmholtz model are compared to that of a recently developed linearized Euler model using two ceramic test liners under the assumed conditions or uniform flow and a plane wave source. The convected Helmholtz model is restricted to uniform mean flow whereas the linearized Euler model can account for the effect or the shear layer. Test data to educe the impedance is acquired from measurements obtained in the NASA Langley Research Center Grazing Incidence Tube for mean flow Mach numbers ranging from 0.0 to 0.5 and source frequencies ranging from 0.5 kHz to 3.0 kHz. The unknown impedance of the liner b educed by judiciously choo~ingth e impedance via an optimization method to match the measured acoustic pressure on the wall opposite the test liner. Results are presented on four spatial grids using three different optimization methods (contour deformation, Davidon-Fletcher Powell, and the Genetic Algorithm). All three optimization methods converge to the same impedance when used with the same model and to nearly identical impedances when used on different models. h anomaly was observed only at 0.5 kHz for high mean flow speeds. The anomaly is likely due to the use of measured data in a flow regime where shear layer effects are important but are neglected in the math models. Consistency between the impedances educed using the two models provides confidence that the linearized Euler model is ready For application to more realistic flows, such as those containing shear layers.

Watson, Willie R.↗

Radiometry spot measurement system

The radiometry spot measurement system (RSMS) has been designed for use in the Diffusive And Radiative Transport in Fires (DARTFire) experiment, currently under development at the NASA Lewis Research Center. The RSMS can measure the radiation emitted from a spot of specific size located on the surface of a distant radiation source within a controlled wavelength range. If the spot is located on a blackbody source, its radiation and temperature can be measured directly or indirectly by the RSMS. This report presents computer simulation results used to verify RSMS performance.

Chen, Harry H.↗

Decision-making Framework to Support the End-of-Life Management of High-Activity Radioactive Sources

Sealed radioactive sources are used for an extremely wide range of purposes, including as radiation sources in various nuclear facilities, universities, hospitals, biomedical and industrial applications, as well as for geological prospecting and exploration. The proper management of these sealed radioactive sources once they have reached their end-of-life is still a global challenge. Very few field-tested Mobile Hot Cells (MHC) exist in the world to support the end-of-life management of disused high-activity radioactive sources. One of the critical challenges that a source recovery team encounters on each site is to find adequate space, and access to that space to complete the staging and recapture process with a MHC; this process is tedious, uncertain, and time-consuming. Therefore, it is essential to understand the planning and management of the MHC setup and takedown. Currently, there isn't an single capable planning tool that will provide an effective medium to plan, inform, educate, and communicate knowledge about the environment where the MHC will be deployed. We present a novel approach for the planning and management of the deployment of the MHC to several different sites that relies on technology. Furthermore, this planning tool will support collaboration, promote information sharing, and foster better decision making processes, resulting in a more efficient, and reliable setup and source recovery with the MHC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Toward a Machine Learning Approach to Interpreting X-ray Spectra of Trace Impurities by Converting XANES to EXAFS

The fact that the photoabsorption spectrum of a material contains information about the atomic structure, commonly understood in terms of multiple scattering theory, is the basis of the popular extended X-ray absorption spectroscopy (EXAFS) technique. How much of the same structural information is present in other complementary spectroscopic signals is not obvious. Here we use a machine learning approach to demonstrate that within theoretical models that accurately predict the EXAFS signal, the extended near-edge region does indeed contain the EXAFS-accessible structural information. We do this by exhibiting deep operator neural networks (DeepONets) that have learned the relationship between the extended and near edge portions of the X-ray absorption spectrum to predict the former from the latter. We find that we can accurately predict the EXAFS spectrum between 6 and 14 Å –1 from the first 6 Å –1 (≈100 eV) of the absorption spectrum of Cu 2 + substitutional defects in the Fe 3+ mineral hematite (α-Fe 2 O 3 ). This surprising finding implies that theoretical analyses of X-ray absorption spectra could be implemented that extract the same conclusions as high-quality EXAFS studies from spectra collected over a much smaller range of photon energies. This relaxes a host of experimental limitations related to the X-ray source and measurement sample, including collection time, minimum dopant concentration, source brilliance, and energy range. We describe the theoretical data sets and DeepONet construction and show that the resulting DeepONets produce EXAFS that recovers linear combination fits to experimental data with accuracy approaching the original ab initio calculations. We discuss the implications of our findings for minor constituent characterization and for understanding the information content of spectroscopic data more broadly, including how this approach might be applied to measured experimental spectra. In conclusion, to encourage similar efforts, the simulated X-ray spectra, machine learning, and fitting code are publicly available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Semiconductor lasers for space sensor applications

Despite their intrinsic power limitations, semiconductor laser diodes are essential for laser-based spaceborne sensor systems covering a wide spectral range, fulfilling such roles as pumping and injection-locking. They may also be used as direct sources in shorter-range operations. AlGaAs laser arrays have been developed for 810-nm band pumping in Nd:YAG lasers otherwise emitting at 1.064 nm. Additional roles include their use as low-power injection seeds, locking a solid-state laser into a specific desired wavelength.

Katz, Joseph↗

Millimeter-wave Point Sources from the 2500 Square Degree SPT-SZ Survey: Catalog and Population Statistics

In this work, we present a catalog of emissive point sources detected in the SPT-SZ survey, a contiguous 2530- square-degree area surveyed with the South Pole Telescope (SPT) from 2008 - 2011 in three bands centered at 95, 150, and 220GHz. The catalog contains 4845 sources measured at a significance of 4.5σ or greater in at least one band, corresponding to detections above approximately 9.8, 5.8, and 20.4 mJy in 95, 150, and 220 GHz, respectively. Spectral behavior in the SPT bands is used for source classification into two populations based on the underlying physical mechanisms of compact, emissive sources that are bright at millimeter wavelengths: synchrotron radiation from active galactic nuclei and thermal emission from dust. The latter population includes a component of high-redshift sources often referred to as submillimeter galaxies (SMGs). In the relatively bright flux ranges probed by the survey, these sources are expected to be magnified by strong gravitational lensing. The survey also contains sources consistent with protoclusters, groups of dusty galaxies at high redshift undergoing collapse. We cross-match the SPT-SZ catalog with external catalogs at radio, infrared, and X-ray wavelengths and identify available redshift information. The catalog splits into 3980 synchrotron-dominated and 865 dust-dominated sources and we determine a list of 506 SMGs. Ten sources in the catalog are identified as stars. We calculate number counts for the full catalog, and synchrotron and dusty components, using a bootstrap method and compare our measured counts with models. This paper represents the third and final catalog of point sources in the SPT-SZ survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Balloon observations of galactic high-energy X-ray sources

A number of X-ray sources were observed with the Naval Research Laboratory hard X-ray observatory during balloon flights on 1976 May 11 and 1977 November 24. The primary objective of the observations was to characterize the temporal and spectral behavior of the sources in the energy range from 20 to 250 keV. Special emphasis was placed on the determination of spectrum versus phase for periodic sources and on the search for spectral features such as the reported 60 keV line in the X-ray spectrum of Her X-1. Results of the observations include: evidence for possible phase-dependent spectral variations in the emission from GX 1+4; flaring in the emission from GX 301-2; detection of unmodulated X-ray emission up to approximately 35 keV from GX 304-1; and an unexpectedly hard spectrum above 20 keV from Cyg X-2.

Maurer, G. S.↗

Towards a Comprehensive Model of Jet Noise Using an Acoustic Analogy and Steady RANS Solutions

An acoustic analogy is developed to predict the noise from jet flows. It contains two source models that independently predict the noise from turbulence and shock wave shear layer interactions. The acoustic analogy is based on the Euler equations and separates the sources from propagation. Propagation effects are taken into account by calculating the vector Green's function of the linearized Euler equations. The sources are modeled following the work of Tam and Auriault, Morris and Boluriaan, and Morris and Miller. A statistical model of the two-point cross-correlation of the velocity fluctuations is used to describe the turbulence. The acoustic analogy attempts to take into account the correct scaling of the sources for a wide range of nozzle pressure and temperature ratios. It does not make assumptions regarding fine- or large-scale turbulent noise sources, self- or shear-noise, or convective amplification. The acoustic analogy is partially informed by three-dimensional steady Reynolds-Averaged Navier-Stokes solutions that include the nozzle geometry. The predictions are compared with experiments of jets operating subsonically through supersonically and at unheated and heated temperatures. Predictions generally capture the scaling of both mixing noise and BBSAN for the conditions examined, but some discrepancies remain that are due to the accuracy of the steady RANS turbulence model closure, the equivalent sources, and the use of a simplified vector Green's function solver of the linearized Euler equations.

Miller, Steven A. E.↗

Imaging with INTEGRAL

The INTEGRAL mission was proposed in response to the ESA M2 call for proposals and is dedicated to the fine spectroscopy and imaging of celestial gamma-ray sources in the energy range 15 keV to 10 MeV. Cosmic gamma-rays are emitted on a wide range of angular scales and structures for a diverse population of astronomical objects. The emission, which includes discrete spectral lines and continuum radiation is derived from point sources, localized regions, as well as a diffuse band along the Galactic plane. Much of the gamma-ray sky is composed from transient phenomena which range from the few second timescale associated with gamma-ray bursts to larger lived events lasting some days or more. These class of events pose the challenge of firstly identification and secondly that of precise positional location of 'random' short lived events which arrive isotropically. In this article the imaging requirements are evaluated in light of current observational astronomical data and practical solutions for the INTEGRAL telescope are discussed. Some of the key problems are highlighted.

Dean, A. J.↗

Positions of galactic X-ray sources - l/II/ between 320 and 340 deg

The precise (20-40 sec) positions of seven X-ray sources in the celestial region corresponding to the galactic longitude range from 320 to 340 deg are reported. The sources include a recurrent transient X-ray source (MX1608-52) and a source 2S1553-542 coincident with a gamma-ray source within the given errors of position. The positions reported reduce the previously reported areas of the error region for six of the sources by factors ranging from 10 to 100. The presented results add confidence to the proposed radio candidates for 4U1624-49 and 4U1642-45 considered by Sanduleak and Dolan (1974) and Seaquist (1977).

Apparao, K. M. V.↗

Theory and simulation of gap distance transitions in planar magnetically insulated transmission lines

Magnetically insulated transmission lines (MITLs) are critical components for efficiently transporting power from pulsed power sources to a diverse range of loads, including magneto-inertial confinement fusion and radiation production. This study investigates the behavior of planar MITLs, taking into account the source voltage and source and load impedances, using two-dimensional theory and simulations. Self-limited behavior, where the MITL operating impedance (voltage divided by current) is insensitive to the value of load impedance, is extended to small-to-large gap distance MITL transitions. Load-limited behavior, in which the load impedance is below the self-limited impedance, causes the MITL operating impedance to adjust to match the load impedance and can be extended to describe large-to-small transitions. In both cases, the operating impedance of the larger MITL section changes to match the self-limited operating impedance of the smaller section. This behavior extends to multiple transitions and to both low and high impedance loads. Assuming equilibration occurs (pulse duration larger than MITL transit time), the entire MITL operating impedance becomes the self-limited impedance of the smallest-gap MITL section or the load impedance, whichever is lower.

Darr, Adam M. [Sandia National Laboratories (SNL-N↗

Development and calibration of UV/VUV radiometric sources

A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

Bridges, J. M.↗

MCNP6 Source Primer: Release 1.0

This document contains examples of MCNP general source usage to support the MCNP6 User’s Manual. The examples range from basic to advanced sources with different applications. There are also examples of how MCNP can fail and warnings for the users to look for at the output to ensure proper results are being created. The overall aim of this document is to provide solid examples of how to define sources with MCNP as well as how to verify the sources are setup properly. The reasoning for needing such complex sources is not discussed in the present work. Also, this document is not meant to be exhaustive of every MCNP source option and combinations of source options possible. However, it is intended to frequently update this document with new source examples provided by users. Please feel free to contact the MCNP6 development team to learn about how to submit a new or updated source example. Please include “General Sources Primer” in the subject line to route the request to the appropriate developers.

97 MATHEMATICS AND COMPUTING↗

High-Performance Electron Sources: Numerical Methods and Beam Dynamics at the Precision Frontier

Electron sources have a wide range of applications and there are many stakeholders that express continuing need for improvements and performance enhancements. Whether we consider ultra-cold, high-brightness, high-charge or high-average current source needs, there are some common themes from the point of view of the beam dynamics involved. These are the following ones: ability to model accurately the emission processes, including the presence of often complicated cathode and other boundary surfaces with a wide range of spatial scales; ability to deal accurately and efficiently with a large number of particles interacting pair-wise, including the stochastic part of these interactions with a wide range of spatial scales; and ability to propagate the particle distributions in time, including collisions with a wide range of temporal scales. These tasks require high precision and accuracy since the goal is usually generation, transport and preservation of very high-quality beams. This grant addressed one of the rem

43 PARTICLE ACCELERATORS↗