Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multi-Block Enhancement for Lagrangian Dendritic Mesh setup in Altair5

Initial mesh setup for an ASC mUlti-physics code at LANL is done using Altair5. Altair5 assumes that the final mesh is composed of logical structured mesh blocks linked together at mesh boundaries to form, ultimately, an unstructured mesh. Within these blocks, meshes may have dendrites, that is, local regions where two zones share common edges (in two-dimensions, or faces in three-dimensions) with a single zone. In many cases, contiguous subsets of the initial set of blocks may have the same material assigned to them, but without smoothing the mesh would form a computationally challenging initial mesh. Some of these blocks may also have zones with nodes on domain boundaries. This paper reports on the implementation of multiblock smoothing in Altair5, which allows for dendrites and for moving boundary nodes. Dendritic nodes are constrained to be located at the average of their neighbor nodes while boundary nodes are constrained to move along the boundary geometry. Two fundamentally different smoothing methods were implemented. First, a variational principle is presented that balances zonal size and distortion via a user selected weighting with constraints imposed using penalty methods for dendritic nodes and Lagrange multipliers for boundary nodes. Second, the Laplace-Beltrami smoother is presented. This is a general elliptic smoother which can easily be modified to give Laplacian and Winslow-Crowley mesh smoothing. Results are shown for several test meshes of interest.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Setup of polarized electron source for parity-violation experiments

Measurement of parity-violation in electron scattering has evolved to measuring sub- part-per-million asymmetries with a precision better than 10 parts-per-billion. This places strict requirements on the electron beam properties, which can only be met through careful configuration of the polarized electron source. In order to control systematics and keep corrections small, the cumulative helicity-correlated position differences of the beam on target are controlled at the level of 1 nm and helicity- correlated angle differences to the 1 nrad level. For the recent Qweak measurement, utilizing the highest power cryotarget ever constructed, a high helicity reversal rate of 960 Hz is required to reduce noise due to density changes in the liquid target. The need for fast reversal presents new challenges for the optimization of the reversal apparatus. In this talk, the setup of the Jefferson Lab polarized electron source for recent parity-violation experiments is discussed along with expected future developments.

Dalton, Mark↗

Separation setup for the light water detritiation process in the water-hydrogen system based on the membrane contact devices

Detritiation of light water wastes down to a level permissible to discharge into the environment while simultaneously concentrating tritium to decrease amount of waste being buried is a constant problem. The laboratory setup for the light water detritiation process is presented. The separation column consists of 10 horizontally arranged perfluorosulphonic acid Nafion-type membrane contact devises and platinum catalyst (RCTU-3SM). Each contact device has 42.3 cm{sup 2} of the membrane and 10 cm{sup 3} of the catalyst. The column is washed by tritium free light water (L{sub H2O}) and the tritium-containing flow (F{sub HTO}) feeds the electrolyser at {lambda} = G{sub H2}/L{sub H2O} = 2. A separation factor of 66 is noted with the device at 336 K and 0.145 MPa. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Study of hydrogen isotopes super permeation through vanadium membrane on 'Prometheus' setup

To develop the membrane pumping technology by means of superpermeable membranes at RFNC-VNIIEF in the 'Prometheus' setup, the experiments on superpermeation of hydrogen isotopes through metal membranes were carried out. The experimental results on superpermeation of thermal atoms of hydrogen isotopes including tritium through a cylindrical vanadium membrane are presented. The possibility of effective pumping, compression and recuperation of hydrogen isotopes by means of superpermeable membrane was demonstrated. The evaluation of membrane pumping rates and asymmetry degree of pure vanadium membrane was given. The work was performed under the ISTC-2854 project. (authors)

36 MATERIALS SCIENCE↗

Evaluation of fission product releases obtained from KueFA safety tests in light of the setup's accuracy - 18692

The Cold Finger Apparatus (KuehlFinger-Apparatur - KueFA) at the European Commission's JRC-Karlsruhe has been designed to assess the effects of Depressurization Loss of Forced Circulation (D-LOFC) accident scenarios on spherical irradiated High Temperature Reactor (HTR) fuel. At approximately 1600 deg. C, the reference maximum temperature for D-LOFC accidents, it has been observed that high-quality German HTR fuel pebbles release only a limited quantity of Cs but a significant amount of Ag. This paper revisits fission product release data obtained from the recently KueFA-tested fuel pebbles HFR-K5/3 and HFR-EU1/3 and presents associated investigations to improve the accuracy of the experimental setup. In light of these findings, implications for previously conducted KueFA heating tests are discussed, considering both experimental data as well as simulated release curves calculated with the Source Term Analysis Code system (STACY). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Setup and performance of RHIC for the 2008 run with deuteron-gold collisions.

This year (2008) deuterons and gold ions were collided in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) for the first time since 2003. The setup and performance of the collider for the 2008 run is reviewed with a focus on improvements that have led to an order of magnitude increase in luminosity over that achieved in the 2003 run.

43 PARTICLE ACCELERATORS↗

Measurement of 238U muonic x-rays with a germanium detector setup

In the field of nuclear non-proliferation muon interactions with materials are of great interest. This paper describes an experiment conducted at the Paul Scherrer Institut (PSI) in Switzerland where a muon beam is stopped in a uranium target. The muons produce characteristic muonic x-rays. Muons will penetrate shielding easily and the produced characteristic x-rays can be used for positive isotope identification. Furthermore, the x-rays for uranium isotopes lie in the energy range of 6-7 MeV, which allows them to have an almost optimal mean free path in heavy shielding such as lead or steel. A measurement was conducted at PSI to prove the feasibility of detecting muonic x-rays from a large sample of depleted uranium (several kilograms) with a germanium detector. In this paper, the experimental setup and analysis of the measurement itself is presented.

47 OTHER INSTRUMENTATION↗

Iron Ore Reduction by Hydrogen Using a Laboratory Scale Fluidized Bed Reactor: Kinetic Investigation—Experimental Setup and Method for Determination

The reduction kinetics of hematite iron ore fines to metallic iron by hydrogen using a laboratory fluidized bed reactor were investigated in a temperature range between 873 K and 1073 K, by measuring the weight change of the sample portion during reduction. The fluidization conditions were checked regarding plausibility within the Grace diagram and the measured pressure drop across the material during experiments. The apparent activation energy of the reduction was determined against the degree of reduction and varied along an estimated two-peak curve between 11 and 55 kJ mol{sup −1}. Conventional kinetic analysis for the reduction of FeO to metallic iron, using typical models to describe gas–solid reactions, does not show results with high accuracy. Multistep kinetic analysis, using the Johnson–Mehl–Avrami model, shows that the initial stage of reduction from Fe{sub 2}O{sub 3} to Fe{sub 3}O{sub 4}, and partly to FeO, is controlled by diffusion and chemical reaction, depending on the temperature. Further reduction can be described by a combination of nucleation and chemical reaction, whereby the influence of nucleation increases with an increasing reduction temperature. The results of the kinetical analysis were linked to the shape of the curve from apparent activation energy against the degree of reduction.

36 MATERIALS SCIENCE↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quality Assurance of Ultrasound Imaging Systems for Target Localization and Online Setup Corrections

We describe quality assurance paradigms for ultrasound imaging systems for target localization (UISTL). To determine the absolute localization accuracy of a UISTL, an absolute coordinate system can be established in the treatment room and spherical targets at various depths can be localized. To test the ability of such a system to determine the magnitude of internal organ motion, a phantom that mimics the human male pelvic anatomy can be used to simulate different organ motion ranges. To assess the interuser variability of ultrasound (US) guidance, different experienced users can independently determine the daily organ shifts for the same patients for a number of consecutive fractions. The average accuracy for a UISTL for the localization of spherical targets at various depths has been found to be 0.57 {+-} 0.47 mm in each spatial dimension for various focal depths. For the phantom organ motion test it was found that the true organ motion could be determined to within 1.0 mm along each axis. The variability between different experienced users who localized the same 5 patients for five consecutive fractions was small in comparison to the indicated shifts. In addition to the quality assurance tests that address the ability of a UISTL to accurately localize a target, a thorough quality assurance program should also incorporate the following two aspects to ensure consistent and accurate localization in daily clinical use: (1) adequate training and performance monitoring of users of the US target localization system, and (2) prescreening of patients who may not be good candidates for US localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance for Kilo- and Megavoltage In-Room Imaging and Localization for Off- and Online Setup Error Correction

In-room radiography is not a new concept for image-guided radiation therapy. Rapid advances in technology, however, have made this positioning method convenient, and thus radiograph-based positioning has propagated widely. The paradigms for quality assurance of radiograph-based positioning include imager performance, systems integration, infrastructure, procedure documentation and testing, and support for positioning strategy implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Margin Evaluation in the Presence of Deformation, Rotation, and Translation in Prostate and Entire Seminal Vesicle Irradiation With Daily Marker-Based Setup Corrections

Purpose: To develop a method for margin evaluation accounting for all measured displacements during treatment of prostate cancer. Methods and Materials: For 21 patients treated with stereographic targeting marker-based online translation corrections, dose distributions with varying margins and gradients were created. Sets of possible cumulative delivered dose distributions were simulated by moving voxels and accumulating dose per voxel. Voxel motion was simulated consistent with measured distributions of systematic and random displacements due to stereographic targeting inaccuracies, deformation, rotation, and intrafraction motion. The method of simulation maintained measured correlation of voxel motions due to organ deformation. Results: For the clinical target volume including prostate and seminal vesicles (SV), the probability that some part receives <95% of the prescribed dose, the changes in minimum dose, and volume receiving 95% of prescription dose compared with planning were 80.5% {+-} 19.2%, 9.0 {+-} 6.8 Gy, and 3.0% {+-} 3.7%, respectively, for the smallest studied margins (3 mm prostate, 5 mm SV) and steepest dose gradients. Corresponding values for largest margins (5 mm prostate, 8 mm SV) with a clinical intensity-modulated radiotherapy dose distribution were 46.5% {+-} 34.7%, 6.7 {+-} 5.8 Gy, and 1.6% {+-} 2.3%. For prostate-only clinical target volume, the values were 51.8% {+-} 17.7%, 3.3 {+-} 1.6 Gy, and 0.6% {+-} 0.5% with the smallest margins and 5.2% {+-} 7.4%, 1.8 {+-} 0.9 Gy, and 0.1% {+-} 0.1% for the largest margins. Addition of three-dimensional rotation corrections only improved these values slightly. All rectal planning constraints were met in the actual reconstructed doses for all studied margins. Conclusion: We developed a system for margin validation in the presence of deformations. In our population, a 5-mm margin provided sufficient dosimetric coverage for the prostate. In contrast, an 8-mm SV margin was still insufficient owing to deformations. Addition of three-dimensional rotation corrections was of minor influence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual Setup Errors Towards the Heart After Image Guidance Linked With Poorer Survival in Lung Cancer Patients: Do We Need Stricter IGRT Protocols?

Image guided radiation therapy (IGRT) is widely used, but data directly relating set-up errors to patient outcome are scarce. This study investigates the relationship between residual IGRT shifts and overall patient survival and uses the observed relations to identify structures sensitive to radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fractionation of critical metals from authentic acid mine drainage using a multi-bed immobilized amine sorbent setup: A field site study

Here for the first time reported, a flow-through multi-fixed bed immobilized amine/silica sorbent strategy was employed to fractionate purified critical metals from authentic acid mine drainage (AMD). The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory’s (NETL) patent-pending Multi-functional Sorbent Technology (MUST) sorbents were used to recover critical metals from AMD at the Pittsburgh Botanic Garden (Pittsburgh, PA USA). By adjusting the AMD/sorbent ratio, we recovered > 80% of pure adsorbed Mn (by adsorbed metal weight) and >90% pure adsorbed Al at lab-scale. Further optimizing the weight hourly space velocity (WHSV) enhanced the rate of adsorbed Al recovery by over five times, justifying a field site test. After treating >100 L of AMD at the field site, the optimized polyamine/epoxysilane/aminosilane sorbent recovered approximately 0.7 wt% adsorbed Al at > 90% purity. A tangible amount of purified aluminum hydroxide [Al(OH) 3 ] and aluminum sulfate [Al 2 (SO 4 ) 3 ] solids were then recovered after eluting and precipitating the previously adsorbed metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗