Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multiple sensor multifrequency eddy current monitor for solidification and growth

A compact cylindrical multisensor eddy current measuring system with integral furnace was develop to monitor II-VI crystal growth to provide interfacial information, solutal segregation, and conductivities of the growth materials. The use of an array of sensors surrounding the furnace element allows one to monitor the volume of interest. Coupling these data with inverse multifrequency analysis allows radial conductivity profiles to be generated at each sensor position. These outputs were incorporated to control the processes within the melt volume. The standard eddy current system functions with materials whose electric conductivities are as low as 2E2 Mhos/m. A need was seen to extend the measurement range to poorly conducting media so the unit was modified to allow measurement of materials conductivities 4 order of magnitude lower and bulk dielectric properties. Typically these included submicron thick films and semiinsulating GaAs. This system was used to monitor complex heat transfer in grey bodies as well as semiconductor and metallic solidification.

Wallace, John↗

Design concept for an optimized earth radiation budget sensor

The Earth Radiation Budget Program has the objective to measure and model the terrestrial radiation budget and obtain a better understanding of the climate and its changes. A multisensor, multisatellite system with high and midinclination orbits will be needed for implementing this program. Various approaches for conducting sensing operations have been evaluated. The present investigation considers a method of sampling with a unique multidirectional array mosaic sensor to fulfill the requirements of earth radiation budget measurements. Previous and present generation earth radiation budget (ERB) satellite instruments are discussed, and attention is given to instrument design tradeoffs and the baseline instrument concept.

Carman, S. L.↗

Multisensor Arrays for Greater Reliability and Accuracy

Arrays of multiple, nominally identical sensors with sensor-output-processing electronic hardware and software are being developed in order to obtain accuracy, reliability, and lifetime greater than those of single sensors. The conceptual basis of this development lies in the statistical behavior of multiple sensors and a multisensor-array (MSA) algorithm that exploits that behavior. In addition, advances in microelectromechanical systems (MEMS) and integrated circuits are exploited. A typical sensor unit according to this concept includes multiple MEMS sensors and sensor-readout circuitry fabricated together on a single chip and packaged compactly with a microprocessor that performs several functions, including execution of the MSA algorithm. In the MSA algorithm, the readings from all the sensors in an array at a given instant of time are compared and the reliability of each sensor is quantified. This comparison of readings and quantification of reliabilities involves the calculation of the ratio between every sensor reading and every other sensor reading, plus calculation of the sum of all such ratios. Then one output reading for the given instant of time is computed as a weighted average of the readings of all the sensors. In this computation, the weight for each sensor is the aforementioned value used to quantify its reliability. In an optional variant of the MSA algorithm that can be implemented easily, a running sum of the reliability value for each sensor at previous time steps as well as at the present time step is used as the weight of the sensor in calculating the weighted average at the present time step. In this variant, the weight of a sensor that continually fails gradually decreases, so that eventually, its influence over the output reading becomes minimal: In effect, the sensor system "learns" which sensors to trust and which not to trust. The MSA algorithm incorporates a criterion for deciding whether there remain enough sensor readings that approximate each other sufficiently closely to constitute a majority for the purpose of quantifying reliability. This criterion is, simply, that if there do not exist at least three sensors having weights greater than a prescribed minimum acceptable value, then the array as a whole is deemed to have failed.

Immer, Christopher↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

Prosser, W. H.↗

Bio-grid system Final report

Feasibility of multiple bio-electrode arrays to sensor galvanic skin response signals during body movement

BODY MEASUREMENT /BIOL/↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

Autonomous navigation preparations for future unmanned space missions

In order to prepare for the era of autonomous navigation, this paper first examines existing techniques for spacecraft navigation by describing the basic elements of the Mark-I and II navigation technologies. The remainder of the paper deals with identification of criteria which necessitate onboard navigation, and with promising solutions now under consideration. An attractive solution possibility is proposed which utilizes narrow-angle optics, a charge-coupled device area-array image sensor, a small advanced onboard flight computer, and a simplified set of software algorithms. Onboard commands would be derived and sent to the appropriate spacecraft attitude control, propulsion, and science platform pointing subsystems. The proposed autonomous navigation system does not address all mission options, but focuses primarily on precision approach trajectory control and adaptive science instrument pointing for asteroid, cometary, and outer planet satellite missions.

Kohlhase, C. E.↗

Differential optical proximity detector

Updated detector can operate under ambient light and uses multiple detectors to locate objects in several different spacial volumes. Sensitivity is approved by scanning field-of-view twice: once with coherent light source turned on and once with background light only. Detector outputs for two cases are amplified and subtracted for each photodiode sensor in array, to eliminate effect of background light.

Johnston, A. R.↗

Polar Environmental Monitoring

The present and projected benefits of the polar regions were reviewed and then translated into information needs in order to support the array of polar activities anticipated. These needs included measurement sensitivities for polar environmental data (ice/snow, atmosphere, and ocean data for integrated support) and the processing and delivery requirements which determine the effectiveness of environmental services. An assessment was made of how well electromagnetic signals can be converted into polar environmental information. The array of sensor developments in process or proposed were also evaluated as to the spectral diversity, aperture sizes, and swathing capabilities available to provide these measurements from spacecraft, aircraft, or in situ platforms. Global coverage and local coverage densification options were studied in terms of alternative spacecraft trajectories and aircraft flight paths.

Nagler, R. G.↗

Description of a dual fail operational redundant strapdown inertial measurement unit for integrated avionics systems research

An experimental redundant strapdown inertial measurement unit (RSDIMU) is developed as a link to satisfy safety and reliability considerations in the integrated avionics concept. The unit includes four two degree-of-freedom tuned rotor gyros, and four accelerometers in a skewed and separable semioctahedral array. These sensors are coupled to four microprocessors which compensate sensor errors. These microprocessors are interfaced with two flight computers which process failure detection, isolation, redundancy management, and general flight control/navigation algorithms. Since the RSDIMU is a developmental unit, it is imperative that the flight computers provide special visibility and facility in algorithm modification.

Bryant, W. H.↗

Advanced technology for earth observation - Data processing

The Experimental Land Observing System (ELOS) is to demonstrate major advances in space-based land observation. Program success will depend upon successful demonstration of both space-segment performance and ground-system capabilities. Increases in data-rate, volume, and processing requirements present substantial challenges to the ground data processing system. ELOS is based on the utilization of the multispectral linear array (MLA) sensor, a solid-state, electronically scanned instrument. Current MLA instrument designs offer a number of capabilities beyond those provided in the Landsat imaging devices. These capabilities include greater resolution, inherent registration, onboard calibration, off-nadir pointing capability, and fore/aft pointing capability. The proposed MLA flight mission scenario will be one of continued growth and will include flights on the Space Transportation System. Attention is also given to ground-to-ground data transport, data capture, and the use of high speed computers.

Heffner, P.↗

MLA instrument concepts for future land remote sensing

The evolution of various Multispectral Linear Array (MLA) sensor concepts occurred over the past several years in response to a corresponding evolution in mission requirements. Initial efforts were concered with sensors for an Operational Land Observation System (OLOS), with free-flying spacecraft at a principal altitude of 705 km. In 1982, studies related to the definition of instruments for an Experimental Land Observation System (ELOS) were conducted. The ELOS mission involves a series of Space-Shuttle sortie flights. The ELOS MLA instrument is to perform two roles. It is to be a key tool for conducting science experiments from the Shuttle, and it is to demonstrate the technology for an eventual free-flying spacecraft. Attention is given to MLA instrument-design concepts, efforts regarding the development of sensors with many narrow spectral bands, and aspects of technology development.

Mika, A. M.↗

Cartography

The demand for cartographic products at scales of 1:25,000 to 1:250,000 continues to increase throughout the world in order to meet requirements associated with: the survey and management of natural resources; environmental planning; and the establishment of geo-referenced data bases. A satellite system involving the use of multispectral linear array (MLA) sensors designed to meet cartographic requirements in terms of the completeness of detail and geometric accuracy standards associated with mapping programs offers great promise for rapidly providing the data with which to produce four types of map products/and data. These include topographic maps; digital terrain information (x,y,z coordinates; thematic mapping; and image maps. Each type of cartographic product/data is briefly considered in relation to current needs.

Source record↗

Monolithic short wave infrared (SWIR) detector array

A monolithic self-scanned linear detector array was developed for remote sensing in the 1.1- 2.4-micron spectral region. A high-density IRCCD test chip was fabricated to verify new design approaches required for the detector array. The driving factors in the Schottky barrier IRCCD (Pdsub2Si) process development are the attainment of detector yield, uniformity, adequate quantum efficiency, and lowest possible dark current consistent with radiometric accuracy. A dual-band module was designed that consists of two linear detector arrays. The sensor architecture places the floating diffusion output structure in the middle of the chip, away from the butt edges. A focal plane package was conceptualized and includes a polycrystalline silicon substrate carrying a two-layer, thick-film interconnecting conductor pattern and five epoxy-mounted modules. A polycrystalline silicon cover encloses the modules and bond wires, and serves as a radiation and EMI shield, thermal conductor, and contamination seal.

Source record↗

Application of a computable model of human spatial vision to phase discrimination

A computable model of human spatial vision is used to make predictions for phase-discrimination experiments. This model is being developed to deal with a broad range of problems in vision and was not specifically formulated to deal with phase discrimination. In the model, cross-correlation of the stimuli with an array of sensors produces feature vectors that are operated on by a position-uncertain ideal observer to simulate detection and discrimination experiments. In this report, the stimuli are compound sinusoidal gratings composed of a fundamental and a higher-frequency component added in various phases. Model predictions are compared with three key results from the literature: (1) the effect of the contrast of the fundamental on phase discrimination, (2) threshold phase difference as a function of the fundamental frequency, and (3) the contrast required for phase discrimination as a function of the frequency ratio of the two grating components. In the first two cases, the predictions capture the main features of the data, although quantitative discrepancies remain. In the third case, the model fails, and this failure suggests additional restrictions on the combination of information across sensors.

Nielsen, K. R. K.↗