Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Analysis and Testing of Parsons NGS Solvent Formulation

Three drums containing solvent used during the Next Generation Solvent Test (NGST) conducted by Parsons in 2014-2015 were received at SRNL. After homogenization, samples from each drum were removed, and a composite sample prepared. This composite was analyzed to determine current SRNL characterization method efficacy, and to determine if the 1,3-dicyclohexyl-2- (isotridecyl) guanidine (DCiTG) suppressor could be selectively removed. The results of this work indicate that the titration analytical method currently employed at SRNL is effective at quantitating the DCiTG. The nuclear magnetic resonance (NMR) method at SRNL can detect the DCiTG, as well its amine and urea decomposition products. However, further development work will be required to allow the 1 H NMR method to quantitate these species. A series of three washing tests were performed on composite samples of the solvent. The results show that up to 67% of the DCiTG was removed from the solvent by simple washing, at multiple ratios of solvent: aqueous phase. This may indicate that a simple pathway exists to wash out the DCiTG and reclaim the solvent (~150 gallons) for future use at the Salt Waste Processing Facility (SWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Contact Conductivity Measurement for Automated Sample Processing Systems

A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

Beegle, Luther W.↗

Understanding the effects of fabrication process on BaZr 0.9 Y 0.1 O 3– δ grain-boundary chemistry using atom probe tomography

Proton-conducting oxides, such as BaZr 0.9 Y 0.1 O 3–δ (BZY10), are receiving significant scientific attention for application in a variety of electrochemical applications. It has been shown that the synthesis route has a significant effect on the ionic behavior of these materials, especially the grain boundaries (GB). In this study, laser-pulsed atom probe tomography (APT) is used to characterize the GB chemistry of BZY10 samples prepared by four different methods: (1) spark plasma sintering (SPS), (2) conventional sintering followed by high-temperature annealing (HT), (3) conventional sintering with NiO used as a sintering aid (SSR-Ni), and (4) solid-state reactive sintering of oxide precursor powders with NiO as a reactive sintering aid (SSRS-Ni). Oxygen depletion (corresponding to oxygen vacancy accumulation) was observed at every GB in this study, consistent with the positive space-charge GB region commonly assigned to these materials. In contrast to the consistent trends associated with oxygen depletion, cation constituents showed varying segregation/depletion behaviors. The samples that used NiO revealed Ni preferentially segregating to the GB. The most common impurities in BZY10 are Al, Fe, Mg, Si, and Sr, all of which generally accumulate at GBs. In order to quantify these chemical trends, the APT method was optimized for this material supplemented with understanding from density functional theory (DFT). Finally, this APT study reveals the complexity of BZY10 GB chemistry and shows that even adjacent GBs in the same material can sometimes show surprisingly different GB chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strategies to Recover Easily-Extractable Rare Earth Elements and Other Critical Metals from Coal Waste Streams and Adjacent Rock Strata Using Citric Acid

Maximum rare earth element (REE) extractability from a sample of Middle Kittanning coal seam underclay was previously demonstrated at ~30% of the total REE content with a citric acid solution (Montross et al., 2020). This report further refines the mechanisms of citrate application for leaching of coal seam underclays using an organic acid lixiviant and evaluates strategies to begin to scale this process to industrially relevant volumes. This study evaluates the suitability of citrate leaching solutions for downstream recovery and separation of the REEs via oxalic acid precipitation. The applicability of citric acid solutions to recover ion-adsorbed metals from clay surfaces was evaluated by leaching a prepared sample of kaolinite with known amounts of ion-adsorbed lanthanum. Citrate systematics was further defined through experiments varying the solution pH. Up-scaling investigations proceeded with percolation leaching columns and stirred tank reactors. Two embodiments were run in percolation leaching: a continuous flow-through process and a multi-stage saturated process. The results showed that in certain limited scenarios, low pH citrate solutions could be used to target REEs mineralized within secondary calcium phosphate minerals. Results from the upscaling attempts encountered difficulties in extraction efficiencies. For the percolation columns, hydrodynamic flow was insufficient to recover the extractable REE content fully. For the stirred barrels, mixing inefficiencies likely inhibited the extractability of the REEs. Oxalic acid precipitation experiments also highlighted difficulties in downstream operations. The REEs were removed from the citrate solution with high efficiency, but were accompanied by equally efficient removal of calcium in orders of magnitude of greater amounts. Overall, for citrate leaching to be effective, future studies will have to: 1) carefully consider the feedstock application (i.e., likely better suited for secondary mineralization of calcium phosphate minerals), and 2) overcome the technical barriers of large-scale processing, such as inefficient hydrodynamic regimes due to small crush sizes needed and difficulties in downstream separation and purification. Alternatively, citrate solutions may be better recommended as leaching amendments to other leaching solutions to enhance REE complexation in the solution.

01 COAL, LIGNITE, AND PEAT↗

Torsional force microscopy of van der Waals moirés and atomic lattices

In a stack of atomically thin van der Waals layers, introducing interlayer twist creates a moiré superlattice whose period is a function of twist angle. Changes in that twist angle of even hundredths of a degree can dramatically transform the system’s electronic properties. Setting a precise and uniform twist angle for a stack remains difficult; hence, determining that twist angle and mapping its spatial variation is very important. Techniques have emerged to do this by imaging the moiré, but most of these require sophisticated infrastructure, time-consuming sample preparation beyond stack synthesis, or both. In this work, we show that torsional force microscopy (TFM), a scanning probe technique sensitive to dynamic friction, can reveal surface and shallow subsurface structure of van der Waals stacks on multiple length scales: the moirés formed between bi-layers of graphene and between graphene and hexagonal boron nitride (hBN) and also the atomic crystal lattices of graphene and hBN. In TFM, torsional motion of an Atomic Force Microscope (AFM) cantilever is monitored as it is actively driven at a torsional resonance while a feedback loop maintains contact at a set force with the sample surface. TFM works at room temperature in air, with no need for an electrical bias between the tip and the sample, making it applicable to a wide array of samples. It should enable determination of precise structural information including twist angles and strain in moiré superlattices and crystallographic orientation of van der Waals flakes to support predictable moiré heterostructure fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inflight resistance measurement on high-T(sub c) superconducting thin films exposed to orbital atomic oxygen on CONCAP-2 (STS-46)

In 1992, UAH (University of Alabama in Huntsville) conducted a unique experiment on STS-46 in which YBa2Cu3O7 (commonly known as '1-2-3' superconductor) high-T(c) superconducting thin film samples prepared at three different laboratories were exposed to 5 eV atomic oxygen in low Earth orbit on the ambient and 320 C hot plate during the first flight of the CONCAP-2 (Complex Autonomous Payload) experiment carrier. The resistance of the thin films was measured in flight during the atomic oxygen exposure and heating cycle. Superconducting properties were measured in the laboratory before and after the flight by the individual experimenters. Films with good superconducting properties, and which were exposed to the oxygen flux, survived the flight including those heated to 320 C (600 K) with properties essentially unchanged, while other samples which were heated but not exposed to oxygen were degraded. The properties of other flight controls held at ambient temperature appear unchanged and indistinguishable from those of ground controls, whether exposed to oxygen or not.

Gregory, J. C.↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing Microstructure-induced Swelling & Thermal Property Changes in Ion-Irradiated Oxide Fuels using Laser-generated Surface Acoustic Waves

Radiation of fuel rods with neutrons during a fission reaction in a nuclear reactor is known to affect the material microstructure of the fuel as a result of fission fragment damage, and lead to the formation of atomic-level defects such as voids, dislocation loops, and lattice swelling from fission-gas release. A consequence of the radiation-induced damage in nuclear fuels is the drastic alteration of material properties, in particular, the reduction of the thermal conductivity – a key parameter that governs the transport of thermal energy released from fissile fuel atoms to the surrounding coolant. Swelling can induce high stresses and ultimate failure of the cladding. A fundamental understanding of the role of radiation-induced damage on the thermal transport and mechanical properties of nuclear fuels is therefore critical for efficient, reliable and safe operation of a nuclear power plant. As opposed to conventional post-irradiation examination techniques that are often time-consuming and require significant sample preparation, laser-based characterization methods have emerged as promising non-contact, non-destructive tools to measure the evolution of microstructure-induced material property changes. Moreover, laser methods offer the promise of in-situ characterization while the material is being irradiated. This project aims to develop an improved understanding of the impact of radiation-induced changes to material microstructure on the thermal and elastic properties of nuclear materials. A laser ultrasonic technique, known as the transient grating (TG) spectroscopy method, is used to simultaneously measure thermal diffusivity and elastic properties in unirradiated and ion-irradiated oxide nuclear fuel samples. The results will complement on-going investigations on electron- and phonon-mediated thermal transport in nuclear materials and will provide foundational work for incorporating the influence of defects in fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis routes to eliminate oxide impurity segregation and their influence on intergrain connectivity in K-doped BaFe 2 As 2 polycrystalline bulks

The poor reproducibility of intergrain critical current density $J_c$ in Fe-based superconductors is often believed to result from uncontrolled grain boundary (GB) connectivity degraded by extrinsic factors such as the local or global impurity concentration or GB porosity or cracks. Earlier we found that Ba and K can appear as oxide impurities at GBs, along with GB-wetting FeAs. In this study, we evaluated how the sample preparation environment and purity of the starting materials influence the polycrystalline $J_c$ in K-doped BaFe 2 As 2 (Ba122) bulks. Using a high-performance glovebox, the oxygen and water levels were significantly reduced, eliminating traces of FeAs. We report oxide impurities and Ba (or K) segregation associated with oxygen in the starting materials were significantly reduced by using high purity starting materials. This combination essentially doubled the best $J_c$(4.2 K) values to 2.3 × 10 5 at self-field and 1.6 × 10 4 A cm –2 at 10 T and analytical scanning transmission electron microscopy showed no GB or O segregation in the best samples, but did show dark Z-contrast and distinct nanoscale porosity. Our work shows that an inert synthesis environment and high purity K and Ba do reduce current-blocking oxygen impurity and GB impurity phases, allowing deeper exploration of the role of extrinsic and intrinsic GB blocking effects in controlling the $J_c$ of polycrystalline Ba122.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using X-ray Micro-Computed Tomography to Three-Dimensionally Visualize the Foregut of the Glassy-Winged Sharpshooter ( Homalodisca vitripennis )

Dissecting the heads of small insects belonging to the order Hemiptera for detailed anatomical investigation with light or scanning electron microscopy is difficult, time-consuming, and destructive, often resulting in sample preparation artifacts. Nevertheless, the structural details of these insects often hold critical information regarding their interactions with bacterial pathogens. For example, the glassy-winged sharpshooter (GWSS) is an efficient vector of the bacterium Xylella fastidiosa, the causal agent of Pierce’s disease in grape vines, but the foregut of this species is exceptionally difficult to dissect. Here, we describe a simple, non-destructive method to investigate the structure of the anterior gut of GWSS using high-resolution micro-computed X-ray tomography (microCT). The use of microCT eliminates the need for destructive dissection and reveals the morphology of small insects in three dimensions, allowing the user to virtually dissect the sample. The use of microCT imaging is a promising and powerful tool in the entomological sciences for studying the structures of vector insects, especially for difficult-to-dissect regions such as the foregut.

54 ENVIRONMENTAL SCIENCES↗

A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

Wang, Zuwei↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New One-Pot Sequential Reduction-Deposition Method for the synthesis of Silica-supported NiPt and CuPt Bimetallic Catalysts

A one-pot redox deposition method is described to prepare silica-supported bimetallic NiPt and CuPt catalysts using differences in standard reduction potentials. The synthesis involved the initial reduction of non-noble metal ions (Ni 2+ and Cu 2+ ) by NaBH 4 , followed by reduction of Pt ions by these reduced metals. Alloy formation and phase purity were established by X-ray diffraction (XRD), bulk composition by X-ray fluorescence (XRF), and surface composition by X-ray photoelectron spectroscopy (XPS). Alloy formation was enhanced by increase in the amount of base metals available to reduce Pt, or through the use of excess NaBH 4 after redox deposition. The catalysts were evaluated for methane oxidation at 300-400 °C and atmospheric pressure. Reference samples prepared using the incipient wetness impregnation (IW) method had inferior performance and characteristics. The redox deposition method provides a simple and versatile protocol for the preparation of bimetallic alloys between noble metals and base metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of synchrotron X-ray fluorescent imaging to study distribution and content of elements in chemically fixed single cells: a case study using mouse pancreatic beta-cells

Synchrotron X-ray fluorescence microscopy (SXRF) presents a valuable opportunity to study the metallome of single cells because it simultaneously provides high-resolution subcellular distribution and quantitative cellular content of multiple elements. Different sample preparation techniques have been used to preserve cells for observations with SXRF, with a goal to maintain fidelity of the cellular metallome. In this case study, mouse pancreatic beta-cells have been preserved with optimized chemical fixation. We show that cell-to-cell variability is normal in the metallome of beta-cells due to heterogeneity and should be considered when interpreting SXRF data. Additionally, we determined the impact of several immunofluorescence (IF) protocols on metal distribution and quantification in chemically fixed beta-cells and found that the metallome of beta-cells was not well preserved for quantitative analysis. However, zinc and iron qualitative analysis could be performed after IF with certain limitations. To help minimize metal loss using samples that require IF, we describe a novel IF protocol that can be used with chemically fixed cells after the completion of SXRF.

59 BASIC BIOLOGICAL SCIENCES↗

Biomolecule Sequencer: Next-Generation DNA Sequencing Technology for In-Flight Environmental Monitoring, Research, and Beyond

On the International Space Station (ISS), technologies capable of rapid microbial identification and disease diagnostics are not currently available. NASA still relies upon sample return for comprehensive, molecular-based sample characterization. Next-generation DNA sequencing is a powerful approach for identifying microorganisms in air, water, and surfaces onboard spacecraft. The Biomolecule Sequencer payload, manifested to SpaceX-9 and scheduled on the Increment 4748 research plan (June 2016), will assess the functionality of a commercially-available next-generation DNA sequencer in the microgravity environment of ISS. The MinION device from Oxford Nanopore Technologies (Oxford, UK) measures picoamp changes in electrical current dependent on nucleotide sequences of the DNA strand migrating through nanopores in the system. The hardware is exceptionally small (9.5 x 3.2 x 1.6 cm), lightweight (120 grams), and powered only by a USB connection. For the ISS technology demonstration, the Biomolecule Sequencer will be powered by a Microsoft Surface Pro3. Ground-prepared samples containing lambda bacteriophage, Escherichia coli, and mouse genomic DNA, will be launched and stored frozen on the ISS until experiment initiation. Immediately prior to sequencing, a crew member will collect and thaw frozen DNA samples, connect the sequencer to the Surface Pro3, inject thawed samples into a MinION flow cell, and initiate sequencing. At the completion of the sequencing run, data will be downlinked for ground analysis. Identical, synchronous ground controls will be used for data comparisons to determine sequencer functionality, run-time sequence, current dynamics, and overall accuracy. We will present our latest results from the ISS flight experiment the first time DNA has ever been sequenced in space and discuss the many potential applications of the Biomolecule Sequencer for environmental monitoring, medical diagnostics, higher fidelity and more adaptable Space Biology Human Research Program investigations, and even life detection experiments for astrobiology missions.

Sequencer↗

Molecular beam epitaxy and crystal structure of majority a -plane-oriented and substrate-strained Mn 3 Sn thin films grown directly on sapphire (0001)

The Kagome antiferromagnet Mn 3 Sn has garnered much attention due to the presence of exciting properties such as anomalous Hall and Nernst effects. This paper discusses the synthesis of crystalline Mn 3 Sn thin films, prepared on Al 2 O 3 (0001) substrates at 453 ± 5°C using molecular beam epitaxy. The growth is monitored in situ using reflection high energy electron diffraction and measured ex situ using x-ray diffraction, Rutherford back-scattering, and cross-sectional scanning transmission electron microscopy. Our analysis shows the in-plane lattice constants of a 1,M = 4.117 ± 0.027 Å and a 2,M = 4.943 ± 0.033 Å, which is a very unexpected result when compared to the bulk a-plane Mn 3 Sn. This indicates a strain in the film and makes it challenging to provide a straightforward explanation. In an effort to explain our results, we discuss two possible orientation relationships between the Mn 3 Sn films and the sapphire substrates. Samples prepared under these conditions appear to have smooth surfaces locally, but overall the film has a 3D island morphology. First-principles calculations provide atomic models of the Mn 3 Sn (112¯0) lattice on Al 2 O 3 (0001) high symmetry sites, indicating that the L3-R90° is the most stable configuration. A detailed discussion of the experimental data and theoretical results, as well as strain effects, is provided.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗