Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rectifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

When ancient numerical demons meet physics-informed machine learning: adjoint-based gradients for implicit differentiable modeling

Recent advances in differentiable modeling, a genre of physics-informed machine learning that trains neural networks (NNs) together with process-based equations, have shown promise in enhancing hydrological models' accuracy, interpretability, and knowledge-discovery potential. Current differentiable models are efficient for NN-based parameter regionalization, but the simple explicit numerical schemes paired with sequential calculations (operator splitting) can incur numerical errors whose impacts on models' representation power and learned parameters are not clear. Implicit schemes, however, cannot rely on automatic differentiation to calculate gradients due to potential issues of gradient vanishing and memory demand. Here we propose a “discretize-then-optimize” adjoint method to enable differentiable implicit numerical schemes for the first time for large-scale hydrological modeling. The adjoint model demonstrates comprehensively improved performance, with Kling–Gupta efficiency coefficients, peak-flow and low-flow metrics, and evapotranspiration that moderately surpass the already-competitive explicit model. Therefore, the previous sequential-calculation approach had a detrimental impact on the model's ability to represent hydrological dynamics. Furthermore, with a structural update that describes capillary rise, the adjoint model can better describe baseflow in arid regions and also produce low flows that outperform even pure machine learning methods such as long short-term memory networks. The adjoint model rectified some parameter distortions but did not alter spatial parameter distributions, demonstrating the robustness of regionalized parameterization. Despite higher computational expenses and modest improvements, the adjoint model's success removes the barrier for complex implicit schemes to enrich differentiable modeling in hydrology.

58 GEOSCIENCES↗

Emission tester for high-power vacuum tubes

A simple emission-testing circuit for high power vacuum tubes to check their output stability is described. With modification it may be useful in testing mercury-arc rectifiers.

Lundy, C.↗

Simple circuit reduces transistor switching time

Silicon-Controlled Rectifier /SCR/, gated by a voltage divider, controls the potentiometer in transistorized switching circuits. The SCR acts as a gate to trigger the switching transistor only when the input signal reaches an amplitude that will switch the transistor rapidly.

Source record↗

Dual-voltage power supply has increased efficiency

Simple circuit provides two different dc output voltages from an ac source. It employs a full-wave rectifier connected to two passive branches from which the separate dc voltages are taken. The outputs have low ripple and good voltage regulation.

Sturman, J. C.↗

Low cost SCR lamp driver indicates contents of digital computer registers

Silicon Controlled Rectifier /SCR/ lamp driver is adapted for use in integrated circuit digital computers where it indicates the contents of the various registers. The threshold voltage at which visual indication begins is very sharply defined and can be adjusted to suit particular system requirements.

Cliff, R. A.↗

Remotely-actuated biomedical switch

Remotely-actuated biomedical switching circuit using transistors consumes no power in the off position and can be actuated by a single-frequency telemetry pulse to control implanted instrumentation. Silicon controlled rectifiers permit the circuit design which imposes zero drain on supply batteries when not in use.

Lee, R. D.↗

An electronic circuit for sensing malfunctions in test instrumentation

Monitoring device differentiates between malfunctions occurring in the system undergoing test and malfunctions within the test instrumentation itself. Electronic circuits in the monitor use transistors to commutate silicon controlled rectifiers by removing the drive voltage, display circuits are then used to monitor multiple discrete lines.

Miller, W. M., Jr.↗

Power control circuit

Power control switching circuit using low voltage semiconductor controlled rectifiers for high voltage isolation

Herron, B. G.↗

Optimal electric-drive system for vehicles

Pulse-width-modulated controller, for vehicle electrically driven by direct current from storage battery and requiring highest possible efficiency in battery use, varies electrical power through silicon controlled rectifiers for permanent magnet dc motors. System is not restricted to dc motors.

Sahinkaya, Y. E.↗

Semiconductor cooling by thin-film thermocouples

Thin-film, metal alloy thermocouple junctions do not rectify, change circuit impedance only slightly, and require very little increase in space. Although they are less efficient cooling devices than semiconductor junctions, they may be applied to assist conventional cooling techniques for electronic devices.

Tick, P. A.↗