Rapid macrovoid characterization in membranes prepared via nonsolvent-induced phase separation: A comparison between 2D and 3D techniques

Optimizing the performance of asymmetric membranes prepared via nonsolvent-induced phase separation (NIPS) requires a quantitative understanding of how processing variables influence membrane morphology. Presently, the most useful structural quantification techniques require 3D visualization of the membrane structure and are best suited for studies seeking detailed information on small datasets. This study proposes and validates a rapid and accurate technique for quantifying macroporosity (i.e., D m ), a simple descriptor of sublayer macrovoid content in asymmetric membranes D m . values measured from segmented cross-sectional imaging performed via X-ray computed tomography (XCT) and scanning electron microscopy (SEM) are presented and compared for three asymmetric membranes prepared from commercial polymers. Importantly, analyses of 3D XCT membrane reconstructions reveal that D m is described by a single, centralized mean, which demonstrates that macrovoid content is spatially homogenous. Thus, D m can be approximated from limited sampling of the 2D cross-sectional membrane structure via SEM. A proposed 2D SEM sampling method provides D m estimates within ±6% of corresponding 3D XCT values with 30 independent measurements for the three membranes. Further sensitivity is achieved using complementary descriptors such as macrovoid count density (i.e., C m ). This technique is thus a useful tool for characterizing macroporosity from a broad selection of membrane samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods for rapid identification of anomalous layers in laser powder bed fusion

In situ process monitoring is a key requirement for increased industry acceptance of powder bed Additive Manufacturing. As sensing technologies increase in maturity, attention must also be given to effective data exploration techniques. These data are often high-resolution and multi-modal, with each build consisting of thousands of layers. Here, in this paper, the authors propose two methods enabling users to rapidly identify layers of interest within a build. Both methods leverage results from deep learning based segmentations of in situ powder bed images. The first method is an unsupervised “reverse layer search” algorithm while the second method uses supervised machine learning.

36 MATERIALS SCIENCE↗

Advancing Elemental and Isotopic Analysis of Uranium Mineral Inclusions: Rapid Screening via Laser-Induced Breakdown Spectroscopy and High-Resolution Laser Ablation-ICP-MS Mapping

The work presented herein employs two laser-based analytical techniques (laser-induced breakdown spectroscopy (LIBS) and laser ablation – inductively coupled plasma – mass spectrometry (LA-ICP-MS)) to spatially determine the elemental and isotopic composition of uranium bearing minerals. Uniquely, this work leverages the high-speed applicability of LIBS to “screen” the sample(s) for their elemental constituents. After determining the location of the uranium inclusions (via LIBS), high-resolution LA-ICP-MS was employed to further characterize the inclusions. The high-resolution (sub-µm) capabilities of LA-ICP-MS were able to extract important information from the uranium minerals including discerning its chemical form (e.g., finchite from carnotite, Sr- and K-bearing uranyl vanadates, respectively) as well as their 235 U/ 238 U isotopic composition. This approach, LIBS followed by LA-ICP-MS, significantly reduces the analysis time (~95 %) in comparison to employing a LA-ICP-MS only approach. Furthermore, this work presented a novel approach to analyzing inclusions via a particle/inclusion analysis tool which is commercially available within the iolite 4 software. This tool allowed for a more accurate characterization of the isotopic distribution of the inclusions, as well as allowing for rapid sizing of the inclusions. Finally, this analytical approach could readily be applied to other sample types in which the target species (e.g., µm-sized inclusions) are embedded in complex matrices (e.g., cm-sized samples).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-photoluminescence mapping and Chemometrics for the rapid classification of rare earth materials

This article introduces advancements in chemically mapping rare earth materials using photoluminescence (PL) and chemometrics. By leveraging the high sensitivity and selectivity of PL compared to alternative optical techniques, as well as its compatibility with microscopy, we present enhanced capabilities for noninvasive material screening and characterization. Exemplary PL spectra of samarium(III) and europium(III) in oxide, nitrate, and chloride forms demonstrated the ability to extract detailed chemical information of diverse rare earth particles. Additionally, we introduced efficient PL mapping sequences capable of covering a 9 mm diameter carbon tab within minutes, which highlighted the benefits of rapid, large-area imaging. Furthermore, an integrated approach combining PL mapping with principal component analysis and a random forest classifier enabled the resolution of overlapping spectral peaks from different chemistries and provided accurate material classification. In conclusion, these advancements underscored the versatility and robustness of PL for chemically mapping rare earth materials, with the potential to support applications in mining, energy, environmental monitoring, isotope production and beyond.

Chemometrics↗

Accurate and rapid acoustic damage characterization in complex structures using sparse sensor networks and deep learning models

Damage diagnosis in critical components is essential for ensuring the safety and reliability of operations across industries, spanning manufacturing, aerospace, and energy. Traditional acoustic nondestructive testing methods primarily focus on detecting defects through the direct scattering of single-mode incident waves from the damage, which limit their applicability to simple structures and small inspection areas. Our earlier research demonstrated that machine learning algorithms combined with sparse sensor networks can identify critical defect signatures even from multiply scattered, multi-mode acoustic signals, indicating the potential for improved defect inspection in complex, real-world structures. In this work, we demonstrate the successful implementation of this approach in a fixed sensor configuration to rapidly and accurately detect simulated defects in a geometrically complex, real-world structure, a brake rotor hub. Three different types of defects were physically simulated on the surface of the hub, and the collected data were used to train an autoencoder-based deep learning model. Two models were tested, one using single measurements and the other using multiple measurements taking advantage of the spatial distribution of the sensor network. After training, the multi-measurement model achieved 100 % accuracy in identifying, classifying, and locating unseen, unique damages. This work illustrates the potential of the proposed method for a wide range of industrial applications.

36 MATERIALS SCIENCE↗

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative high-temperature ammonium bifluoride fusion and rapid analysis of elements with nuclear forensic value

High-temperature ammonium bifluoride (ABF) fusions were evaluated for potential use in rapid dissolution of post-detonation nuclear debris. The ABF fusion was carried out in a Pt crucible which allowed evaluation of higher fusion and evaporation temperatures. The high-temperature ABF fusion dissolution method was evaluated using geological reference materials: USGS QLO-1a Quartz Latite, USGS SDC-1 Mica Schist, and NIST 278 Obsidian Rock. The optimized dissolution method involved a 10 min fusion at 540 °C, a 5 min reflux in 8 M HNO 3 , an evaporation at 300 °C and final dilution into 45 mL of 2% (v/v) HNO3. The final solution was filtered after heating at 105 °C using a hotblock. This dissolution method was simple, requiring only a hotplate or hotblock, filtered samples were available for ICP-MS analysis or radiochemical separation within 150 min, and was found to have high (>90%) recovery for many isotopes of interest in nuclear forensics applications. U and Pu in the dissolved material was separated using TEVA and UTEVA extraction chromatography columns, a process which resulted in >90% recovery. An irradiated U tracer was spiked into the material prior to dissolution and analyzed for recovery of major fission products and 239Np. The monitored radionuclides had recoveries of greater than 90%, except for the volatile radioiodine isotopes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the short-wave infrared response of strained GeSn/Ge multiple quantum wells by rapid thermal annealing

In this work, the evolution of structural, optical and optoelectronic properties of coherently strained Ge 0.883 Sn 0.117 /Ge multiple quantum wells (MQWs) grown by molecular beam epitaxy under rapid thermal annealing (RTA) is systematically investigated. The MQW structure remains fully-strained state with RTA at 400 °C or below and disrupts at higher annealing temperatures due to Sn segregation and interdiffusion of Ge and Sn atoms. The GeSn well layers exhibit the strongest absorption in 2.0–2.4 μm after annealing at 400 °C and become transparent above 1.8 μm after RTA at 600 °C or beyond due to serve Sn segregation. Owing to improved crystal quality after RTA at 400 °C, the dark current of the fabricated metal-semiconductor-metal photodetector is effectively lowered by more than two times. Additionally, the responsivities at 1.55 and 2.0 μm are improved by 4.15 and 3.78 folds, respectively, compared to those of the as-grown sample. Here, the results can be an insightful guidance for the development of high-performance short-wave infrared photonic devices based on Sn-containing group-IV low-dimensional structures.

36 MATERIALS SCIENCE↗

Active and machine learning-based approaches to rapidly enhance microbial chemical production

In order to make renewable fuels and chemicals from microbes, new methods are required to engineer microbes more intelligently. Computational approaches, to engineer strains for enhanced chemical production typically rely on detailed mechanistic models (e.g., kinetic/stoichiometric models of metabolism)—requiring many experimental datasets for their parameterization—while experimental methods may require screening large mutant libraries to explore the design space for the few mutants with desired behaviors. To address these limitations, we developed an active and machine learning approach (ActiveOpt) to intelligently guide experiments to arrive at an optimal phenotype with minimal measured datasets. In this study, ActiveOpt was applied to two separate case studies to evaluate its potential to increase valine yields and neurosporene productivity in Escherichia coli. In both the cases, ActiveOpt identified the best performing strain in fewer experiments than the case studies used. This work demonstrates that machine and active learning approaches have the potential to greatly facilitate metabolic engineering efforts to rapidly achieve its objectives.

60 APPLIED LIFE SCIENCES↗

Stream lamination and rapid mixing in a microfluidic jet for X-ray spectroscopy studies

Microfluidic mixers offer new possibilities for the study of fast reaction kinetics down to the microsecond time scale, and methods such as soft X-ray absorption spectroscopy are powerful analysis techniques. These systems impose challenging constraints on mixing time scales, sample volume, detection region size and component materials. The current work presents a novel micromixer and jet device which aims to address these limitations. The system uses a so-called ‘theta’ mixer consisting of two sintered and fused glass capillaries. Sample and carrier fluids are injected separately into the inlets of the adjacent capillaries. At the downstream end, the two streams exit two micron-scale adjoining nozzles and form a single free-standing jet. The flow-rate difference between the two streams results in the rapid acceleration and lamination of the sample stream. This creates a small transverse dimension and induces diffusive mixing of the sample and carrier stream solutions within a time scale of 0.9 microseconds. The reaction occurs at or very near a free surface so that reactants and products are more directly accessible to interrogation using soft X-ray. We use a simple diffusion model and quantitative measurements of fluorescence quenching (of fluorescein with potassium iodide) to characterize the mixing dynamics across flow-rate ratios.

Huyke, Diego A. (ORCID:0000000283356613)↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Screening of Single-Atom Catalyst Synthesis Conditions Using ToF-SIMS and Facet-Dependent Single-Crystal Substrates

Single-atom catalysts (SACs) offer superior catalytic performance compared to traditional nanoparticle catalysts but are challenging to develop because of the need for extensive optimization and specialized characterization techniques. Here, this study presents a rapid and versatile method for detecting synthesis conditions and elucidating deposition mechanisms of SACs on various substrates. By depositing active elements (Au, Cu, Ni and Rh) on facet-specific single-crystalline substrates (CeO 2 , TiO 2 , MgO and Al 2 O 3 ) and employing time-of-flight secondary ion mass spectroscopy (ToF-SIMS), we assessed facet-dependent deposition behaviors and identified optimal conditions for solution-based SAC synthesis. On CeO 2 and TiO 2 , we confirmed facet-dependent deposition, primarily influenced by oxygen vacancy density and photocatalytic activity, respectively. MgO exhibited the formation of metal oxide/hydroxide clusters for all active elements, and the degree of clustering for Cu and Ni was correlated with the facet hydrolysis susceptibility. Notably, Au and Rh deposition on MgO was facet-independent, attributed to the formation of hydroxide species in solution. Al 2 O 3 , due to its chemical stability and lack of surface defects, did not show active element deposition. This study not only provides a time and cost-efficient method for prescreening SAC synthesis conditions, but it also provides valuable insights into the various deposition mechanisms governing SAC formation on different substrates, paving the way for the rational design of tailored SACs for various catalytic applications.

ToF-SIMS↗

Robust Rapid Cellular Metabolite Sensing Using Benchtop NMR and SABRE-Hyperpolarized [1- 13 C]Pyruvate

Hyperpolarized NMR has emerged as a powerful analytical technique to significantly enhance targeted NMR signals, improving the sensitivity for investigations of unique chemical and biological dynamics. Here, we demonstrate the use of a hyperpolarization strategy based on Signal Amplification By Reversible Exchange (SABRE) to generate highly reproducible doses of a hyperpolarized [1- 13 C]pyruvate probe for benchtop characterization of yeast metabolism. This method allows rapid, scalable, and benchtop preparation of biocompatible hyperpolarized solutions suitable for live-cell experiments. We show that this production can be dove-tailed into a modular, compact workflow to characterize real-time metabolism in cell cultures, using Saccharomyces cerevisiae (Baker’s yeast) as a model organism. With high temporal resolution, we show that this method can resolve the conversion of hyperpolarized [1- 13 C]pyruvate into oxidative decarboxylation products CO 2 and bicarbonate. This conversion exhibits sustained and detectable metabolic activity for over 300 s after introduction of the agent to the cells. We model the metabolite kinetics to show decarboxylation activity and derive estimates of the pH over time from the CO 2 and bicarbonate (carbonic acid buffer system) equilibrium to probe changes in the cellular environment during active metabolism. These results highlight the utility of benchtop SABRE-hyperpolarized [1- 13 C]pyruvate as a scalable, specific probe for metabolic phenotyping of living cells using compact, low-cost instrumentation well-suited for future high-throughput applications across microbial engineering, drug response profiling, and dynamic metabolic screening.

fungi↗

Rapid Crystallization of Zeolites with Controllable Defects: Disentangling Fluoride Concentration and pH Using NH 4 F

Zeolite synthesis is typically conducted either under basic conditions or in neutral fluoride media using hydrofluoric acid (HF). While basic (OH − ) conditions generally result in faster zeolite crystallization, they can also increase the likelihood of framework defects and crystal intergrowths. In contrast, synthesis in neutral fluoride media tends to produce fewer defects because fluoride balances positive charges from structure-directing agents. However, this method often requires significantly longer crystallization times and involves the handling of dangerous HF. In the present study, we pursue the best of both synthesis conditions, rapid syntheses with controllable defect concentrations, by disentangling of mineralizing agent and chargebalancing agent using ammonium fluoride (NH 4 F) as an alternative to HF. We have investigated the use of NH 4 F in the syntheses of siliceous and aluminum-containing zeolite A (LTA, small pore), ZSM-5 (MFI, medium pore), and siliceous Beta(*BEA, large pore). The crystallization times of all four zeolites decreased substantially with an increasing NH 4 F concentration. Crystallization times were reduced from 24 to 4 h (Si-LTA), 96 to 36 h (Al-LTA), 240 to 6 h (ZSM-5), and 24 to 3 h (Si-*BEA). Additionally, increasing the NH 4 F concentration in the synthesis mixtures decreases the defect densities of siliceous zeolites. Raman spectroscopy, along with 29 Si MAS NMR, 19 F MAS NMR, 13 C MAS NMR, and fluorine elemental analysis of Si-LTA samples confirms that the reduction in charged defects (Si−O − ) is due to the higher incorporation of F − within the double four-membered ring (D4R) present in the LTA samples. We show that the accelerated crystallization is due to the role of F − in enhancing the silica mineralization rate (formation of silicon hexafluoride species) and stabilizing D4Rs under basic conditions. As a result, combining basic and fluoride-mediated synthesis could therefore be advantageous for faster zeolite production and improved control over structural properties for a wide variety of zeolite structures.

Anions↗

Rapid Identification of Synthetic Routes to Functional Metastable Phases Using X-ray Probed Laser Anneal Mapping (XPLAM) Time-Temperature Quench Maps

Many material systems have known or predicted functional phases that are metastable at standard temperature and pressure. While substantial advances have been made in the high-throughput and combinatorial synthesis of materials with a range of stoichiometries, investigation of thermal processing remains largely the domain of iterative uniform anneals or static gradients. Here we develop X-ray probed laser anneal mapping (XPLAM), a high throughput technique coupling spatially resolved X-ray diffraction with microsecond to millisecond laser gradient anneals to produce temperature–dwell–transformation (TDT) diagrams of the phase as a function of quench time and temperature. In addition to showing regimes where specific metastable phases form preferentially, TDT diagrams provide insight into the submillisecond kinetics of solid–solid phase transitions. This is a unique tool for mapping reaction pathways for metastable phases. As a first demonstration of XPLAM, we study Bi2O3, which has a rich set of polytypes, including the d-phase with an exceptionally high oxygen ion conductivity. We demonstrate the first annealing-driven synthesis of room temperature d-Bi2O3. We expect XPLAM to prove a powerful technique for rapid identification of synthetic routes to metastable phases and to generate the exhaustive data sets required for machine learning-guided exploration of materials processing.

36 MATERIALS SCIENCE↗

Rapid and Efficient Arsenic Removal by Iron Electrocoagulation Enabled with in Situ Generation of Hydrogen Peroxide

Millions of people are exposed to toxic levels of dissolved arsenic in groundwater used for drinking. Iron electrocoagulation (FeEC) has been demonstrated as an effective technology to remove arsenic at an affordable price. However, FeEC requires long operating times (~hours) to remove dissolved arsenic due to inherent kinetics limitations. Air cathode Assisted Iron Electrocoagulation (ACAIE) overcomes this limitation by cathodically generating H 2 O 2 in situ. In ACAIE operation, rapid oxidation of Fe(II) and complete oxidation and removal of As(III) are achieved. Here, we compare FeEC and ACAIE for removing As(III) from an initial concentration of 1464 μg/L, aiming for a final concentration of less than 4 μg/L. We demonstrate that at short electrolysis times (0.5 min), i.e., high charge dosage rates (1200 C/L/min), ACAIE consistently outperformed FeEC in bringing arsenic levels to less than WHO-MCL of 10 μg/L. Using XRD and XAS data, we conclusively show that poor arsenic removal in FeEC arises from incomplete As(III) oxidation, ineffective Fe(II) oxidation and the formation of Fe(II–III) (hydr)oxides at short electrolysis times (<20 min). Finally, we report successful ACAIE performance (retention time 19 s) in removing dissolved arsenic from contaminated groundwater in rural California.