Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multi frame radiography of supersonic water jets interacting with a foil target

Pulsed-power-driven underwater electrical explosion of cylindrical or conical wire arrays produces supersonic water jets that emerge from a bath, propagating through the air above it. Interaction of these jets with solid targets may represent a new platform for attaining materials at high pressure (>1010 Pa) conditions in a university-scale laboratory. However, measurements of the internal structure of such jets and how they interact with targets are difficult optically due to large densities and density contrasts involved. We utilized multi-frame x-ray radiographic imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility to explore the water jet and its interaction with a 50 μm thick copper foil placed a few mm from the surface of water. The jet was generated with a ∼130 kA-amplitude current pulse of ∼450 ns rise time applied to a conical wire array. X-ray imaging revealed a droplet-type structure of the jet with an average density of <400 kg/m3 propagating with a velocity of ∼1400 m/s. Measurements of deformation and subsequent perforation of the target by the jet suggested pressures at the jet–target interface of ∼5 × 109 Pa. The results were compared to hydrodynamic simulations for better understanding of the jet parameters and their interaction with the foil target. These results can be used in future research to optimize the platform, and extend it to larger jet velocities in the case of higher driving currents supplied to the wire array.

Physics↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Nonplanar effects in simulations of laser-driven ejecta microjet experiments

Recent experiments of laser-driven ejecta microjets performed at OMEGA 60 reveal tortuous jets whereby the jets appear to deviate from their initial trajectory as they travel in vacuum. To understand these data, we perform two dimensional numerical simulations, considering different target thicknesses, pressures, and models of the drive conditions. In particular, modeling the finite laser spot size appears essential in reproducing qualitatively the non-planar shock observed in the experiment. Simulations capture jet deflection by accounting for a slight misalignment of the laser pointing with respect to the groove axis along with spatial variation of the laser pulse intensity. The principal physical mechanism appears to be that lateral momentum is imparted by release waves arising from the non-planar drive. The induced off-axis velocity is small in comparison to the jet axial velocity but integrates into a pronounced deflection over the course of the experiment. The analysis of jet axial and lateral mass distributions is found to be reproduced reasonably by the simulations. Simulated radiographs are in qualitative agreement with the experiments, though their differences point to potential shortcomings in modeling strictly three-dimensional experiments using two-dimensional hydrodynamic simulations. The simple analysis is able to explain part of the observed discrepancy in simulated vs experimental jet masses.

42 ENGINEERING↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Quantitative radiography for determining density fluctuations in HED experiments

We have developed a method to extract density fluctuation measurements from x-ray radiographs of high-energy density (HED) instability growth and turbulence experiments. We use this information to calculate density fluctuation statistics for constraining the performance of turbulent mix models in HED systems. The density calculation combines image filtering, removal of systemic effects such as backlighter variation, calculation of transmission across multiple materials, and use of tracer materials to generate an approximate single-material density field. From the density map, we calculate both average density and a variance-like moment b (density-specific-volume covariance), which we compare to our models. We infer both quantities from a single image, which is significantly more information than the historic single scalar mix width measurements. We also develop a method of analyzing simulation outputs that incorporate both the density fluctuation metric from a turbulence model and the bulk material maps from the hydrodynamic code. This analysis helps address the question of how to initialize the simulations for best comparison to data from systems with large separations of scale in the mixing perturbation initial condition. We find that our data analysis method yields 1D average density and b curves with similar morphology and amplitudes as those from preliminary simulation comparisons.

47 OTHER INSTRUMENTATION↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Neutron generation dynamics inside a MA-class dense plasma focus Z-pinch

Dense plasma focii (DPFs) are appealing as energy efficient sources of short pulses of ions, neutrons, and x rays. The output of these sources is expected to scale with input current (I4), but has been shown to drop at the MA level [S. K. H. Auluck, “On the failure of neutron yield scaling in the dense plasma focus,” Phys. Plasmas 30, 080701 (2023)]. New results on the MegaJOuLe Neutron Imaging Radiography DPF showed neutron yield production in agreement with the input current scaling beyond the previously observed drop. This work provides insight into the pinch formation on a DPF and reports on the two different mechanisms leading to neutron generation inside a DPF using a combination of kinetic simulations and experimental data. A combination of particle-in-cell (PIC) and 1D shock theory results are used to describe the pinch formation and disassembly and the corresponding thermonuclear and beam-target mechanisms. The temporal evolution of the pinch column predicted by the PIC simulations shows qualitative agreement with the experimental data from plasma photon emission as well as temporal neutron pulse shapes. In MJ-class DPFs, both thermonuclear and beam-target mechanisms can occur over the course of the implosion and contribute to the total neutron production. Hence the neutron source size of a DPF will change throughout the implosion. Experimental neutron radiographs show the increase in source size as the pinch breaks apart, in agreement with simulation's prediction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow visualization in high-energy-density laboratory plasmas

Flow visualization is often essential for evaluating high-energy-density (HED) laboratory plasmas, examining their dynamics, and assessing design strategies. However, imaging at fine phenomenological flow scales is a major challenge. Here, a zone-plate–based radiography system tailored for applications in HED physics is demonstrated. The burst-mode radiography system combines a dual-flash laser-generated x-ray source, a high-magnification zone plate optic, and a multiple frame hybrid complementary metal-oxide-semiconductor (hCMOS) sensor for image detection. Operating at a magnification of 42 x⁠, a pair of radiographs is measured in rapid succession, each time gated by a 4.75 keV flash of x rays lasting 100 ps. The system achieves a spatial resolution below 3 μm. The potential of this approach for applications in HED physics is exemplified by observing small-scale spike morphologies at a pusher-foam interface impacted by a strong, laser-driven blast wave.

Flow instabilities↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of improvement of energy conversion rate from kJ PW laser to protons with electron confinement

Kilojoule-class relativistic intensity lasers can produce energetic protons with high energy conversion efficiencies in the interaction with a thin foil target. Using the national ignition facility advanced radiographic capability (NIF-ARC) laser, we demonstrated an enhancement of energy conversion from laser to protons by the effective confinement of fast electrons in the laser spot by random kicks from the self-excited field. The number of fast electrons was increased by 4.6 times by increasing the ratio of the laser spot size to the foil thickness to strengthen the confinement effect. The energy conversion efficiency from laser to protons increases approximately linearly with the enhancement of the number of fast electrons. The conversion rate for protons with energies above 8 MeV was 1.8 %. The result leads to high efficiency proton acceleration which is beneficial in applications, such as proton radiography and plasma heating in laser fusion.

Physics↗

Hot electron preheat effects in two-photon polymerization plastic lattice laser-driven shock-tube experiments on the OMEGA laser

We present simulations of Omega shock tube experiments designed to investigate hot electron preheat effects in 3D-printed, two-photon polymerization (2PP) plastic lattices. Preheat is inferred in the experiments from the expansion of a plastic witness disk embedded in the lattice. Using the Eulerian radiation-hydrodynamics code xRAGE, we model shock propagation and preheat from both radiative and hot electron energy sources to evaluate their relative impact. To simulate the transport of laser-generated hot electrons, the nonlocal electron heat transport model proposed by Schurtz, Nicolaï, and Busquet (SNB) is extended with a hot electron source term and an energy cascade algorithm. We explore how variations in ablator, lattice geometry, and laser drive affect the shock velocity and witness disk expansion. Simulations show that the inclusion of a 5 μm gold layer reduces shock pressure by 60% and shock speeds by 30%–40% but does not significantly reduce the hot electron preheat, and that different lattice geometries lead to enhanced shock velocities—up to 40% faster than in homogeneous foams. However, radiative and conductive preheat from classical mechanisms alone fail to match experiment. By including a hot electron source term, we reproduce experimental observables such as disk expansion rates and spatial radiographic features. We find that a hot electron population corresponding to 4%–8% of the incident laser energy with T hot = 50 keV produces expansion which agrees with the experimental data, suggesting hot electron preheat is the most plausible explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗