THERMS Technology Commercialization Fund Final Report
The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.