Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peak Prediction Using Multi Layer Perceptron (MLP) for Edge Computing ASICs Targeting Scientific Applications

High data rate detectors play an integral part in scientific research and their development is actively pursued at High Energy Physics (HEP) facilities around the world. Edge Machine Learning (ML) offers the ability to reduce data rates by integrating ML algorithms into Application Specific Integrated Circuits (ASICs) on the front end electronics. In this work, we explore a set of neural network architectures for predicting the peak amplitudes in the detector's sensor response. We have designed and synthesized several MLP based neural networks comparing their inference accuracy, power consumption, and area targeting for minimal latency. The neural networks are synthesized in a commercial 65nm process. The effect of quantizing the network's weights and biases on hardware performance and area is reported. We also conduct design space exploration to compare between design alternatives

47 OTHER INSTRUMENTATION↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

In-Pixel Readout IC with compact in-pixel ADC for Pixel detectors at HL LHC

The prototype Smart Pixel concept test chip (SP28), designed in a CMOS 28 nm bulk process, is a proof of concept readout integrated circuit (ROIC) designed for a future Phase III High Luminosity upgrade of the Large Hadron Collider. It employs a synchronous analog to digital converter (ADC) for the front-end design, with signal processing and data conversion within a single bunch crossing of 25 ns. It is therefore capable of accurately detecting hits occurring in consecutive bunch crossings, without off-time registration of events and pileup insensitivity, making it particularly suitable for the inner most layers of the vertex detector. The ROIC consists of a matrix of 32 × 16 pixels, each 25 × 25 µm 2 in size. Each pixel contains a charge sensitive preamplifer with leakage current compensation, three auto-zero comparators for a 2-bit fash-type ADC. The total power consumption is approximately 5 µW per pixel. The measured noise at the output of all the hit comparators across the ROIC is < 90 e- with threshold dispersion < 45 e-RMS, which allows an in-time threshold setting of ≈ 475 e-.

Parpillon, Benjamin↗

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultimate Colliders

Our understanding of the Universe critically depends on the fundamental knowledge of particles and fields, which represents a central endeavor of modern high-energy physics. Energy frontier particle colliders - arguably, among the largest, most complex and advanced scientific instruments of modern times - for many decades have been at the forefront of scientific discoveries in high-energy physics. Due to technology advances and beam physics breakthroughs, the colliding beam facilities have progressed immensely and now operate at energies and luminosities many orders of magnitude greater than the pioneering instruments of the early 1960s. While the Large Hadron Collider and the Super-KEKB factory represent the frontier hadron and lepton colliders of today, respectively, future colliders are an essential component of a strategic vision for particle physics. Conceptual studies and technical developments for several exciting near- and medium-term future collider options are underway internationally. Analysis of numerous proposals and studies for far-future colliders indicate the limits of the collider beam technology due to machine size, cost, and power consumption, and call for a paradigm shift of the particle physics research at ultra-high energy but low luminosity colliders approaching or exceeding 1 PeV center-of-mass energy scale.

43 PARTICLE ACCELERATORS↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

System and method for high dynamic range waveform digitization

Diverse applications from particle physics experiments to lidar are driving cost and current reduction in giga-hertz sampling rate high-resolution data conversion. Multiple imagers captures a single pixel of data and require processing at very high speed. High-bandwidth high-rate signal sampling, analog-to-digital conversion, and transfer of large amounts of data to a digital data acquisition block are required in such systems. Dynamic range, power consumption, and transfer of high-speed, high-bit width data are key implementation challenges. Data acquisition architectures optimized for specific requirements of such systems may facilitate system implementation and reduce overall system cost.

Mostafanezhad, Isar↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

A Low-Cost, Reconfigurable UWB Microwave Radar Front-End for Fine Resolution Nadir-Looking Measurements of Snow and Layered Media

This paper presents a reconfigurable, low-cost ultra-wideband microwave radar front-end and radar demonstrator designed for nadir-looking measurements of layered media (e.g. snow or vegetation) from either a fast-moving ground-based platform or a C-3 class unmanned aerial system (UAS). The radar demonstrator uses a frequency modulated continuous-wave (FMCW) architecture and can be configured to operate in either the 2-8 GHz or in the 12-18 GHz range, providing fine vertical resolution while offering a significantly reduced weight, size, and power consumption with respect to prior implementations. We have demonstrated the operation of the system in the 2-8 GHz and 12-18 GHz bands in the laboratory; in the 2-8 GHz band using a surface-based setup in Antarctica; and in the 2.6-7 GHz band on local flight tests onboard an Aurelia X6 Pro UAS equipped with 3-D printed antennas. This paper provides an overview of the radar front-end and demonstrator design and implementation and a summary of the different tests completed to document their performance.

UWB radar, UAS-borne radar, snow-probing radar.↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Behind-the-meter resource management system

A method and a system for managing power resources. One or more measurements received from one or more sensors communicatively coupled to at least one processor are processed. The sensors monitor and measure at least one of: one or more operational parameters associated with operation of at least one equipment, one or more external parameters associated with an environment of the equipment, and one or more power parameters associated with a power consumption by the equipment. Based on the processed one or more measurements, one or more future operational parameters associated with an operation of the are determined. The operation of the equipment is controlled using the determined future operational parameters.

Rajagopal, Ram↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

A DATA EFFICIENT SPARSE MODELING FRAMEWORK FOR POWER ESTIMATION IN WATER TREATMENT SENSING OPERATIONS

With increasing freshwater scarcity, advanced process design mechanisms such as Closed-Circuit Reverse Osmosis (CCRO) and Digital/Physical Twin systems are gaining traction in water treatment and reuse operations. While digital and physical twin models enable improved system insight and control, their development is often expensive and computationally intensive, requiring large volumes of synthetic or experimental data to characterize underlying process dynamics. This work introduces a sparse surrogate modeling framework to estimate power consumption from measured flow and pressure variables, along with their nonlinear polynomial and interaction expansions. To ensure model reliability and reduce overfitting, a two-stage pipeline is proposed. First, a dynamic data filtering algorithm is employed to remove uninformative observations and transient operational states. Second, a sparse penalized regression technique is applied to select a minimal set of parsimonious features. The proposed model achieves high sparsity, retaining only 7 out of 34 candidate features (≈79.41% sparsity) while delivering a root mean square error (RMSE) of 0.072 on the test dataset.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗