Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Apollo portable life support system performance report

The performance of the Apollo portable life support system (PLSS) on actual lunar missions is discussed. Both subjective comments by the crewmen and recorded telemetry data are evaluated although emphasis is on the telemetry data. Because the most important information yielded by the PLSS deals with determination of crewman metabolic rates, these data and their interpretation are explained in detail. System requirements are compared with actual performance, and the effect of performance margins on mission planning are described. Mission preparation testing is described to demonstrate how the mission readiness of the PLSS and the crewmen in verified, and to show how the PLSS and the crewmen are calibrated for mission evaluation.

Carson, M. A.↗

A portable life support system for use in mines

The portable life support system described in this paper represents a potential increase in the probability of survival for miners who are trapped underground by a fire or explosion. The habitability and life support capability of the prototype shelter have proved excellent. Development of survival chamber life support systems for wide use in coal mines is definitely within the capabilities of current technology.

Zeller, S. S.↗

Semiclosed-circuit atmosphere control in a portable recompression chamber

A small portable recompression chamber is described that can be used both to treat a diver for decompression sickness or to transport him to a larger chamber complex. The device can be operated in either open circuit or semiclosed circuit atmospheres, permits two way conversation between patient and attendant, and uses an air injector for circulation of the chamber atmosphere.

Riegel, P. S.↗

High intensity portable fluorescent light

Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

Kendall, F. B.↗

A portable hydrazine attitude propulsion test system

The portable hydrazine attitude propulsion module is described that was designed and developed to support the attitude control pitch axis simulation tests performed on an air bearing table for the thermoelectric outer planet spacecraft program. The propulsion module was a self-contained, liquid hydrazine propulsion system from which the exhausted gases were generated within the catalyst bed of either of two nominal 0.22-N opposing thrusters. The module, which was designed for convenient assembly onto and removal from an air bearing table, was tested to establish its operational safety. This test history and the very conservative design of the module enabled it to be man-rated for operation in the presence of personnel. The report briefly summarizes the system operations during air bearing table tests, presents a detailed description of the propulsion module hardware, and discussing the system evolution.

Moynihan, P. I.↗

A portable self-contained gas chromatograph.

The design and fabrication of a completely portable, self-contained gas chromatograph is described. This instrument utilizes a closed-loop hydrogen carrier gas flow as maintained by a hydrogen generator-separator. It employs an auxiliary hydrogen generator to keep a positive flow of hydrogen through the detector. The detector is an ionization cross section detector. The only maintenance required is the addition of water (5-15 cc/day) to the auxiliary hydrogen generator. Lower limit of detection for the present system is of the order of 1-10 ppm ethane.

Stevens, M. R.↗

Self-recording portable soil penetrometer

A lightweight portable penetrometer for testing soil characteristics is described. The penetrometer is composed of a handle, data recording, and probe components detachably joined together. The data recording component has an easily removed recording drum which rotates according to the downward force applied on the handle, and a stylus means for marking the drum along its height according to the penetration depth of probe into the soil.

Costes, N. C.↗

Lunar portable magnetometer experiment

The purpose of the Apollo 16 lunar portable magnetometer (LPM) experiment is to measure the permanent magnetic field at different geological sites on the lunar surface. The LPM field measurements are a vector sum of the steady remanent field from the lunar crust and of the time-varying ambient fields. The remanent magnetic fields measured in the Descartes region are the largest extraterrestrial fields yet measured in situ. These measurements show for the first time that the Descartes highlands have a stronger remanent magnetization than do the mare regions of the previous Apollo landing sites. The experimental technique used in the LPM experiment is described and the preliminary results obtained are discussed.

Dyal, P.↗

A portable millisecond-integration-time photoelectric photometer.

Portable equipment for recording millisecond-integration-time photoelectric photometric data is described. Digital data are reliably recorded on standard 6.35 mm audio grade magnetic tape via a quadradial audio grade tape deck. The system is designed specifically for recording lunar occulations of stars, but the data recording technique is independent of the data source. Recovery of the data is made via minicomputer.

Mcgraw, J. T.↗

Portable headset microphone checker

Simple and reliable test system gives go/no-go indication of output level of headset microphones. Portable system has its own internal battery power supply and can be used in field or in laboratory with wide variety of headset types.

Davenport, J.↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

Deyo, J.↗

A gas flow indicator for portable life support systems

A three-part program was conducted to develop a gas flow indicator (GFI) to monitor ventilation flow in a portable life support system. The first program phase identified concepts which could potentially meet the GFI requirements. In the second phase, a working breadboard GFI, based on the concept of a pressure sensing diaphragm-aneroid assembly connected to a venturi, was constructed and tested. Extensive testing of the breadboard GFI indicated that the design would meet all NASA requirements including eliminating problems experienced with the ventilation flow sensor used in the Apollo program. In the third program phase, an optimized GFI was designed by utilizing test data obtained on the breadboard unit. A prototype unit was constructed using prototype materials and fabrication techniques, and performance tests indicated that the prototype GFI met or exceeded all requirements.

Bass, R. L., III↗

Technology assessment of portable energy RDT and P

Results are presented of a workshop conducted to assess portable energy technology. The results were evaluated and areas for future research were considered. Several research categories were studied: increasing presently available fuel supplies, developing new fuel sources, utilization of new transportation fuels, improving conservation practices, and equitable distribution of fuel supplies. Several research projects were proposed, and work statements were constructed for those considered suitable.

Vanston, J. H., Jr.↗

Portable medical status system

Electrical schematics and outline drawings of the portable medical status unit are presented along with recommendations for future units.

Source record↗

Development and testing of a portable wind sensitive directional air sampler

A portable wind-sensitive directional air sampler has been developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. Functional testing of a prototype sampler is described; all items exhibited performance and life sufficient to carry out field performance test operations. Life testing of the wind direction sensor and the directional porting valves, which are critical to reliable operation, was emphasized with successful results.

Deyo, J.↗

Improved thermal storage material for portable life support systems

The availability of thermal storage materials that have heat absorption capabilities substantially greater than water-ice in the same temperature range would permit significant improvements in performance of projected portable thermal storage cooling systems. A method for providing increased heat absorption by the combined use of the heat of solution of certain salts and the heat of fusion of water-ice was investigated. This work has indicated that a 30 percent solution of potassium bifluoride (KHF2) in water can absorb approximately 52 percent more heat than an equal weight of water-ice, and approximately 79 percent more heat than an equal volume of water-ice. The thermal storage material can be regenerated easily by freezing, however, a lower temperature must be used, 261 K as compared to 273 K for water-ice. This work was conducted by the United Aircraft Research Laboratories as part of a program at Hamilton Standard Division of United Aircraft Corporation under contract to NASA Ames Research Center.

Kellner, J. D.↗

Inexpensive portable drug detector

Inexpensive, easy-to-use, self-scanning, self-calibrating, portable unit automatically graphs fluorescence spectrum of drug sample. Device also measures rate of movement through chromatographic column for forensic and medical testing.

Dimeff, J.↗

Portable Oxygen Subsystem (POS)

Concept selection, design, fabrication, and testing of a Portable Subsystem (POS) for use in space shuttle operations are described. Tradeoff analyses were conducted to determine the POS concept for fabrication and testing. The fabricated POS was subjected to unmanned and manned tests to verify compliance with statement of work requirements. The POS used in the development program described herein met requirements for the three operational modes -- prebreathing, contaminated cabin, and personnel rescue system operations.

Source record↗