Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasma temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Bubbling Water–Treating DBD Plasma Device Optimization Using Experimental and Computational Methods

A dry air atmospheric pressure volume dielectric barrier discharge is employed to fix nitrogen in water. Producing nitrate for use as nitrogen fertilizer is the primary motivation. A 0D chemistry model is developed and informed by the electrical, and geometric characteristics of the device and the plasma gas temperature. Modeled ozone and nitrate densities are compared to those measured experimentally in the plasma effluent and treated liquid for a range of gas temperatures. Modeled and measured ozone densities are in good agreement; however, the model lacks the liquid chemistry to properly represent the measured nitrate density. A gas temperature-based shift from ozone to NO x producing regimes is observed in both experiment and model, and the reactions responsible are evaluated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unraveling Spatio-Temporal Chemistry Evolution in Laser Ablation Plumes and Its Relation to Initial Plasma Conditions

The chemistry evolution in a laser ablation plume depends strongly on its initial physical conditions. In this article, we investigate the impact of plasma generation conditions on the interrelated phenomena of expansion dynamics, plasma chemistry, and physical conditions. Plasmas are produced from a uranium metal target in air using nanosecond, femtosecond, and femtosecond filament-assisted laser ablation. Time-resolved two-dimensional spectral imaging was performed for evaluating the spatio-temporal evolu-tion of atoms, diatoms, polyatomic molecules, and nanoparticles in situ. Emission spectral features reveal that molecular formation occurs at early times in both femtosecond and filament ablation plumes, although with different temporal decay. In contrast, mo-lecular formation is found to occur at much later times in nanosecond plasma evolution. Spectral modeling is used to infer tem-poral behavior of plasma excitation temperature, and results highlighted that nanosecond plume temperatures decay rapidly while plumes generated by filament ablation show slowest decay. In this work, we find U atoms and UO molecules co-exist in ultrafast laser produced plasmas even at early times after plasma onset owing to favorable temperatures for molecular formation. Regardless of irradiation conditions, plume emission features showed presence of higher oxides (i.e. UxOy), although with different temporal histories. Our study provides insight into the impact of plasma generation conditions on chemistry evolution in plasmas produced from traditional focused femtosecond, nanosecond, and filament-assisted laser ablation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theory of the ion–electron temperature relaxation rate in strongly magnetized plasmas

Recent works have shown that strongly magnetized plasmas characterized by having a gyrofrequency greater than the plasma frequency exhibit novel transport properties. One example is that the friction force on a test charge shifts, obtaining components perpendicular to its velocity in addition to the typical stopping power component antiparallel to its velocity. Here, we apply a recent generalization of the Boltzmann equation for strongly magnetized plasmas to calculate the ion–electron temperature relaxation rate. Strong magnetization is generally found to increase the temperature relaxation rate perpendicular to the magnetic field and to cause the temperatures parallel and perpendicular to the magnetic field to not relax at equal rates. This, in turn, causes a temperature anisotropy to develop during the equilibration. Strong magnetization also breaks the symmetry of independence of the sign of the charges of the interacting particles on the collision rate, commonly known as the “Barkas effect.” Furthermore, it is found that the combination of oppositely charged interaction and strong magnetization causes the ion–electron parallel temperature relaxation rate to be significantly suppressed, scaling inversely proportional to the magnetic field strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal transport modeling of laser-irradiated spheres

Thermal transport of uniformly laser-irradiated spheres of various materials is investigated computationally. One-dimensional simulations of low- to mid-Z materials (Be, Al, and Cu) are performed to evaluate the impact of nonlocal electron transport on experimental observables under laser intensities of relevance to direct-drive inertial confinement fusion. Here we compare thermal transport models of different levels of fidelity: flux-limited Spitzer–Harm diffusion, the Schurtz–Nicolai–Busquet (SNB) reduced-order nonlocal model, and a Fokker–Planck description. Spitzer–Harm diffusion with different flux-limiter factors are compared with different implementations of the SNB model in the HYDRA radiation hydrodynamics code. Under the conditions of interest, the peak heat flux in the thermal front with the SNB model shows good agreement with Fokker–Planck calculations, with the largest errors below 10% at 10 15 W/cm 2 laser intensity. From HYDRA-SNB simulations, two experimentally relevant effects are observed from nonlocal heat transport when compared to flux-limited Spitzer–Harm modeling: coronal temperatures are cooler due to reduced heat fluxes in the expanding plasma and (for mid-Z materials) x-ray emissions are enhanced due to preheating in the dense plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Depyrogenation using plasmas: A novel approach for endotoxin deactivation using a dielectric barrier discharge at atmospheric pressure

Developing a low-cost depyrogenation process is vital in extending the medical applicability of polymers that can be used in medicine. We present an overview of the plasma-based depyrogenation literature and address the need to develop a nonthermal plasma-based depyrogenation process for delicate materials such as chitosan. We present a low-cost plasma apparatus to treat chitosan powder in hermetically sealed bags. We decouple the experiments into two parts: depyrogenation experiments for dried standard endotoxin on glass slides and analysis of chitosan modifications through Fourier-transform infrared spectroscopy. We demonstrate depyrogenation efficacy with up to a 4-log reduction in endotoxin levels and discuss minor changes observed in plasma-treated chitosan.

atmospheric pressure plasmas↗

High-fidelity modeling of breakdown in helium: initiation processes and secondary electron emission

Understanding the role of physical processes contributing to breakdown is critical for many applications in which breakdown is undesirable, such as capacitors, and applications in which controlled breakdown is intended, such as plasma medicine, lightning protection, and materials processing. The electron emission from the cathode is a critical source of electrons which then undergo impact ionization to produce electrical breakdown. In this study, the role of secondary electron yields due to photons (γ ph ) and ions (γ i ) in direct current breakdown is investigated using a particle-in-cell direct simulation Monte Carlo model. The plasma studied is a one-dimensional discharge in 50 Torr of pure helium with a platinum cathode, gap size of 1.15 cm, and voltages of 1.2–1.8 kV. The current traces are compared with experimental measurements. Larger values of γ ph generally result in a faster breakdown, while larger values of γ i result in a larger maximum current. The 58.4 nm photons emitted from He(2 1 P) are the primary source of electrons at the cathode before the cathode fall is developed. Of the values of γ ph and γ i investigated, those which provide the best agreement with the experimental current measurements are γ ph = 0.005 and γ i = 0.01. In this work, these values are significantly lower than those in the literature for pristine platinum or for a graphitic carbon film which we speculate may cover the platinum. This difference is in part due to the limitations of a one-dimensional model but may also indicate surface conditions and exposure to a plasma can have a significant effect on the secondary electron yields. The effects of applied voltage and the current produced by a UV diode which was used to initiate the discharge, are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decomposition of methane diluted with inert gas in an RF discharge cell

Decomposition of methane using non-thermal plasmas is an attractive route for producing hydrogen-rich gases and valuable carbon nanomaterials. Understanding how plasma discharge modes influence methane decomposition in optimizing plasma-assisted chemical conversion remains unexplored. This study explores the coupling between the discharge structure and product selectivity in RF capacitively coupled discharges operating in methane/inert gas mixtures in the pressure range of 2–3 torr. Under our experimental conditions the discharge exhibits mode transitions from uniform to striated in Ar and Kr and from diffuse to contracted in Ar and Kr with <5% CH 4 . The discharges in He and Ne remained uniform under our operating conditions, and their mixtures with CH 4 remained diffuse. A 0-d model for Ar/CH 4 discharge established a threshold for contraction while also asserting the importance of Ar$^{*}_{\textrm{m}}$ in the dissociation and ionization processes. The highest degree of methane decomposition, >99.7% with the main products of acetylene and graphitized solid carbon was achieved in the contracted discharge mode for both Kr or Ar with ⩽5% CH 4 . We demonstrate that contraction can play a crucial role in the effective decomposition of methane with value-added products and that both the electronic and thermal properties of plasma gas are responsible for this effect.

RF plasma↗

Benchmark of the KGMf with a coupled Boltzmann equation solver

The Kinetic Global Model framework (KGMf) is an open-source general-purpose global model (spatially averaged) simulation code developed to explore the reaction kinetics and pathways in plasma discharge systems. It contains species continuity and electron energy balance equations, with a time-dependent evaluated electron energy distribution function (EEDF) for electron impact reactions. The EEDF is utilized to determine the rate coefficients for electron impact reactions, which can have profound impact on the temporal evolutions of plasma parameters. Previously, the EEDF was commonly assumed as Maxwellian or an analytical function of the effective electron temperature. In this work, the KGMf is coupled with a Boltzmann equation (BE) solver to self-consistently compute the EEDF. The EEDF evolution frequency is determined based on relative changes of the reduced electric field. The KGMf is benchmarked with the ZDPlasKin code based on high-pressure low-temperature argon plasma discharge cases. Additionally, the temporal evolutions of reduced electric field, electron temperature, EEDF, reaction rates, and species densities, are obtained and compared under different discharge conditions, showing good agreement between the KGMf and the ZDPlasKin simulations. The application of the KGMf for predicting breakdown times in high power microwave discharges is also presented, which shows qualitative agreement with particle-in-cell simulations. The KGMf can be further applied for more complicated plasma discharge systems, where the reaction kinetics are more intricate (e.g., plasma-assisted combustion systems).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time and space resolved diagnostics for plasma thermal-chemical instability of fuel oxidation in nanosecond plasma discharges

Here, an instability in a nanosecond pulsed dielectric barrier discharge plasma occurring in methane–oxygen–argon mixtures is experimentally observed and measured by 1D time-resolved in situ electric field measurements. This instability, which seems to be created by the positive feedback between plasma kinetics and plasma-assisted low temperature fuel oxidation, is studied using electric field induced second harmonic generation and direct ICCD imaging. The rapid formation of streamers from an originally uniform discharge appears to be caused by the chemical kinetics of plasma-assisted low temperature methane oxidation, which may be resulting in a new type of plasma instability: a thermal-chemical instability. The results also revealed that the occurrence of this possible thermal-chemical instability in a reactive flow drastically changes the plasma properties by forming multiple secondary discharges and possibly leads to micron-sized non-uniform electric distributions. Single shot uncalibrated measurements of the electric field of the micron sized streamers appears to show much greater strengths than the average electric field. Furthermore, one-dimensional data analysis shows the positive feedback loop between the streamers and the low temperature plasma assisted oxidation chemistry in the plasma thermal-chemical instability. The present finding advances the understanding plasma instability growth and provides a new way to control plasma uniformity in plasma-assisted combustion and plasma fuel reforming.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Developments and Challenges in the Design of the ITER DRGA

We report the ITER Diagnostic Residual Gas Analyzer (DRGA) will measure the distribution of gas species, i.e., deuterium (D), tritium (T), and impurities, in the divertor exhaust stream and in the plasma periphery, with time resolution relevant to fusion plasma–wall particle dynamics. The uniqueness of the DRGA, over previous implementations of plasma dynamics residual gas analysis, is an integrated approach, combining mass and low-temperature plasma-activated optical spectroscopy, in a differentially pumped analysis station. A further unique feature of the ITER divertor-specific DRGA is an ~8-m separation of the analysis station from the sampled pumping duct, while still maintaining a ~1-s response time for hydrogen isotopic concentrations. ITER DRGA final design activities are strongly benefiting from testing of prototypical DRGA components and methods on present fusion devices, most currently on JET and W7-X. DRGA systems are implemented on both these devices and include sensors (and pumping methods) that are directly relevant to the ITER DRGA design. The recent JET-DTE2 campaign has provided the first experience on operating the combined ITER DRGA sensors with D-T plasmas. While enhancing system design for ITER, this experience on operating devices has also revealed additional engineering challenges, which further guide the continuing final design project. Meanwhile, the recent determination that the ITER DRGA, with slight optimization, will resolve the helium isotopes well enough to support an ITER pre-DT, He-3-based heating scheme, has greatly increased ITER Research Program interest in the DRGA and its implementation well ahead of the DT phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-beam plasma source deposition of carbon thin films

A single-beam plasma source was developed and used to deposit hydrogenated amorphous carbon (a-C:H) thin films at room temperature. The plasma source was excited by a combined radio frequency and direct current power, which resulted in tunable ion energy over a wide range. The plasma source could effectively dissociate the source hydrocarbon gas and simultaneously emit an ion beam to interact with the deposited film. Using this plasma source and a mixture of argon and C 2 H 2 gas, a-C:H films were deposited at a rate of ~26 nm/min. The resulting a-C:H film of 1.2 µm thick was still highly transparent with a transmittance of over 90% in the infrared range and an optical bandgap of 2.04 eV. Young’s modulus of the a-C:H film was ~80 GPa. The combination of the low-temperature high-rate deposition of transparent a-C:H films with moderately high Young’s modulus makes the single-beam plasma source attractive for many coatings applications, especially in which heat-sensitive and soft materials are involved. Here, the single-beam plasma source can be configured into a linear structure, which could be used for large-area coatings.

14 SOLAR ENERGY↗