Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Evaluating the Interactions Between Variable Renewable Energy and Diurnal Storage

Cost declines and growing deployment of photovoltaic (PV), wind, and storage have led to increasing interest in the potential interactions of these three technologies as their role in the power system grows. In this work we enhance a national-scale capacity expansion model to evaluate how PV, wind, and storage interact in the evolution of the power system. Importantly, the modeling framework captures interactions in both investments and operations. Through this work we identify significant synergies between PV and storage. Scenarios with more PV always have more storage, and scenarios with more storage always have more PV. This synergy is due to the diurnal alignment of PV generation with 4-8 hour storage, and to the ability of PV to narrow system peaks to allow shorter-duration storage to serve as a peaking resource. Interactions between wind and storage are less pronounced, though we do observe that longer-duration storage resources appear to provide greater value for wind.

14 SOLAR ENERGY↗

WISE-2005: LBNP/Treadmill and Resistive Exercise Countermeasures Maintain Aerobic Capacity during a 60-d Bed Rest

We have previously documented that supine treadmill exercise within lower body negative pressure (LBNPex) performed 6 sessions (raised dot) wk(sup -1) during 15- and 30-day bed rests (BR) maintained upright aerobic capacity (VO2pk). In the present study, ure are evaluating whether aerobic capacity is maintained during a 60-d BR when the LBNPex frequency is reduced to 2-4 sessions (raised dot) wk(sup -1) and resistance exercise (REX) is added 2-3 sessions (raised dot) wk(sup -1). Eight healthy women (32 plus or minus 4 yrs; 56.4 plus or minus 3.6 kg; 164 plus or minus 8 cm; mean plus or minus SD) performed maximal-exertion, graded treadmill tests before and 3 days after a 60-d, 6 deg. head-down tilt BR. (Earliest day the medical monitors would permit a maximal exercise test post-BR). During BR, four subjects performed no exercise (CON), while four other subjects (EX) performed LBNPex and REX on separate days. The LBNPex countermeasure employed an intermittent (40-80% pre-BR VO2pk), 40-min protocol against an LBNP pressure (-49 plus or minus 3 mmHg) applied to provide a footward force equivalent to 1.0-1.2 body weight. REX consisted of maximal concentric and eccentric supine leg press and heel raise exercises using a gravity-independent flywheel ergometer. Comparisons were performed using paired (within-group) or non-paired (between-group) t-tests. Three days post-BR, VO2pk of the CON group was reduced significantly from pre-BR (Pre:37.2 plus or minus 1.2, Post: 29.4 plus or minus 2 ml (raised dot) kg(sup -1) (raised dot) min(sup -1), P less than 0.05), while the VO2pk of the EX group was not significantly reduced (Pre: 39.6 plus or minus 1.9, Post: 38.0 plus or minus 0.6 ml (raised dot) kg(sup -1) (raised dot) min(sup -1)). Peak heart rate, ventilation, rating of perceived exertion, and respiratory exchange ratio were not significantly different between the two groups pre- and post-BR. These preliminary results suggest that the combined LBNPex and REX countermeasures may be sufficient to maintain upright aerobic capacity after long-duration space flights.

Schneider, Suzanne M.↗

Stabilizing the Grid and Reducing Utility Bills Through Price-Responsive Controls for Heat Pump Water Heaters

The electricity grid is facing increasing challenges in cost-effectively balancing supply and demand. These challenges are exacerbated by increased penetration of photovoltaics, which causes mid-day overproduction, and electrification of gas appliances, which increases peak-period electricity demand. Decarbonization requires shifting building loads from fossil-intensive high-cost times to renewable-intensive low-cost times while maintaining quality of service to occupants. Utilities and ISO’s are investigating new ways of incentivizing this load shifting. One promising method is the use of Highly Dynamic Prices (HDPs). HDPs feature continuously changing prices that reflect real-time grid generation and distribution costs and capacity constraints, and thus incentivize consumers to shift their loads. California’s CPUC CalFUSE proposal and Hawaii’s recent changes demonstrate that electricity tariffs are moving towards this model. For this to work however, loads must have the capability to respond to these prices. Heat pump water heaters (HPWHs) are an ideal device for this purpose because their storage tanks decouple delivery of domestic hot water from electricity consumption. The storage enables control strategies that consume midday solar power to increase the energy stored in the tank, then provide evening peak domestic hot water services using the stored energy. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls for many flexible loads - including HPWHs - in response to HDP. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of the on-board controller in a residential, integrated HPWH . The price-responsive controls a) shift load in ways that consume additional midday solar power to help stabilize the grid and reduce overall emissions, b) ensure that occupants receive equal or better hot water delivery service, and c) minimize the operating cost for each home in the fleet. On the grid level, the resulting shift will reduce utility operating costs and emissions, and can avoid expensive system capacity expansions. The control approach is customized to each home based on typical hot water consumption patterns. HPWH controllers, whether on the device or remotely, will receive a schedule of CTA-2045-B signals or set temperature adjustments customized to the current HDP price schedule and home. Simulation results for a fleet of 148 HPWHs on a summer day in Berkeley, California show cost savings of 29% and high price electricity consumption reductions of 80%, while maintaining full quality of service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of the DOE photovoltaic concentrator development project

Photovoltaic concentrator technology resulting in low cost, long-life photovoltaic arrays at a price of less than $0.50 per peak watt by 1986 was developed. Concentrator concepts are identified which have the highest potential for low-cost long life by supporting concept development and evaluation, improving solar array manufacturing technology and by increasing solar array production capacity and quantity.

Schueler, D. G.↗

Effect of Three Modifications on Performance of Auxiliary-Stage Supercharger for V-1710-93 Engine

Three modifications of the auxiliary-stage supercharger for the V-1710-93 engine were designed and tested as part of an investigation to improve the power output and the altitude performance of the engine. A 12-vane diffuser was substituted for the standard 11-vane diffuser, and a vaneless discharge passage and a modified scroll were designed to increase the flow capacity of the supercharger and thereby to increase the performance at the high volume flows required by the engine. With the 12-vane diffuser installed and the carburetor replaced by an adapter, the equivalent volume flow at the peak efficiency point was increased 25 percent at the lowest speed investigated and 9.5 percent at the highest speed. When the carburetor was used, any increase in equivalent volume flow was masked by choking in the carburetor. A small decrease in the peak adiabatic efficiency resulted from using the 12-vane diffuser. At the high volume flows where the supercharger is required to operate, the performance was improved by the 12-vane diffuser. With the vaneless discharge passage, the surge-free range of the supercharger was increased 35 percent at the lowest tip speed investigated by increasing the maximum air flow. The maximum air flow at high tip speeds was again limited by choking in the carburetor, which masked the effect of the vaneless discharge passage on the maximum air flow. At the high volume flows near the operating point of the supercharger, the performance with the vaneless discharge passage was better than that with the standard 11-vane diffuser. At the low volume flows when the standard 11-vane diffuser gave better performance. The modified scroll gave performance characteristics that were practically the same as those of the standard scroll except at high tip speeds, where the peak performance was improved.

Downing, Richard M.↗

Modified Laser Flash Method for Thermal Properties Measurements and the Influence of Heat Convection

The study examined the effect of natural convection in applying the modified laser flash method to measure thermal properties of semiconductor melts. Common laser flash method uses a laser pulse to heat one side of a thin circular sample and measures the temperature response of the other side. Thermal diffusivity can be calculations based on a heat conduction analysis. For semiconductor melt, the sample is contained in a specially designed quartz cell with optical windows on both sides. When laser heats the vertical melt surface, the resulting natural convection can introduce errors in calculation based on heat conduction model alone. The effect of natural convection was studied by CFD simulations with experimental verification by temperature measurement. The CFD results indicated that natural convection would decrease the time needed for the rear side to reach its peak temperature, and also decrease the peak temperature slightly in our experimental configuration. Using the experimental data, the calculation using only heat conduction model resulted in a thermal diffusivity value is about 7.7% lower than that from the model with natural convection. Specific heat capacity was about the same, and the difference is within 1.6%, regardless of heat transfer models.

Lin, Bochuan↗

Evaluation of New Actuators in a Buffet Loads Environment

Ongoing research in buffet loads alleviation has provided an application for recently developed piezoelectric actuators capable of higher force output than previously existing actuators could provide and that can be embedded within the vehicle s structure. These new actuators, having interdigitated electrodes, promise increased performance over previous piezoelectric actuators that were tested on the fin of an F/A-18 aircraft. Two new actuators being considered by the United States Air Force to reduce buffet loads on high performance aircraft were embedded into the fins of an F/A-18 wind-tunnel model and tested in the Transonic Dynamics Tunnel at the NASA Langley Research Center. The purpose of this test program, called ENABLE (Evaluation of New Actuators in a Buffet Loads Environment), was to examine the performance of the new actuators in alleviating fin buffeting, leading to a systems -level study of a fin buffet loads alleviation system architecture being considered by the USAF, Boeing, and NASA for implementation on high performance aircraft. During this windtunnel test, the two actuators performed superbly in alleviating fin buffeting. Peak values of the power spectral density functions for tip acceleration were reduced by as much as 85%. RMS values of tip acceleration were reduced by as much as 40% while using less than 50% of the actuators capacity. Details of the wind-tunnel model and results of the wind-tunnel test are provided herein.

Moses, Robert W.↗

Daily Supine LBNP Treadmill Exercise Maintains Upright Exercise Capacity During 14 Days of Bed Rest

Exposure to microgravity or bed rest reduces upright exercise capacity. Exercise modes, durations, and intensities which will effectively and efficiently counteract such deconditioning are presently unresolved. We that daily supine treadmill interval training with lower body negative pressure (LBNP) would prevent reduction in upright exercise capacity during 14 days of 6 deg. head-down bed rest (BR). Eight healthy male subjects underwent two 14 day BR protocols separated by 3 months. In a crossover design, subjects either remained at strict BR or performed 40 min of daily exercise consisting of supine walking and running at intensities varying from 40-80% of pre-BR upright peak oxygen uptake (VO2). LBNP during supine exercise was used to provide 1.0 to 1.2 times body weight of footward force. An incremental upright treadmill test to measure submaximal and peak exercise responses was given pre- and post-BR. In the non-exercise condition, peak VO2 and time to exhaustion were reduced 16 +/- 4% and 10 +/- 1% (p less than 0.05), respectively, from pre-BR. With LBNP exercise these variables were not significantly different (NS) from pre-BR. During submaximal treadmill speeds after BR, heart rate was higher (11 +/- 11 bpm, p less than 0.05) and respiratory exchange ratio was elevated (p less than 0.05) in the no exercise condition. Both were maintained at pre-BR levels in the LBNP exercise condition (NS from pre-BR). Since this supine treadmill interval training with addition of LBNP maintained upright exercise responses and capacity during BR, this countermeasure may also be effective during space flight.

Ertl, Andy C.↗

Extreme confinement of hydrogen gas within fullerenelike nanoporous carbon

Nanoporous carbons and carbon nanostructures can store hydrogen at cryogenic temperatures but lack the volumetric and gravimetric capacity to be industrially significant. Recent inelastic neutron scattering experiments suggest a highly dense phase of hydrogen at temperatures well above the melting point of solid hydrogen. However, it remains unclear how pore geometry and intermolecular interactions enable these dense phases to exist, with dispersion (van der Waals) or electrostatic/induction suggested to be the key effects in slit and curved pores but their relative contributions have yet to be quantified. In this paper, we perform benchmark electronic structure calculations allowing the interactions between planar and curved aromatic molecules with hydrogen to be accurately determined. Dispersion was found to dominate over electrostatic and inductive effects with some many-body charge transfer (Dobson type-A) effects needed to capture the most highly curved structures. Density functional methods that include type-A many-body effects were found to accurately describe the intermolecular interactions at a fraction of the cost of coupled-cluster simulations and these approaches were used to calculate the energies inside large carbon bowl and slit pores. The interaction energies inside the bowl pores were found to depend on the orientation of the hydrogen molecule. This rotational barrier, modeled as a quantum hindered rotor, could reproduce the peak splitting observed in inelastic neutron scattering experiments, with weak splitting arising from bowl-like fullerene pores and strong splitting from highly confining nanotubelike pores. Increasing the fraction of such curved pores in nanoporous carbons may therefore offer a pathway to enhance their hydrogen-storage capacity. Moreover, the preferential adsorption of ortho hydrogen on nanotubelike pores could enable the storage of high-density hydrogen without the need to remove heat produced during the ortho-para hydrogen conversion.

36 MATERIALS SCIENCE↗

Highly cascaded first-order sapphire optical fiber Bragg gratings fabricated by a femtosecond laser

This Letter reports an innovative technique for fabricating large-scale, highly cascaded first-order sapphire optical fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method. For the first time, to the best of our knowledge, this study successfully demonstrates a distributed array of 10 FBGs within highly multimode sapphire crystal fiber, made possible by employing a high-power laser technique to generate larger reflectors with a Gaussian intensity profile. These first-order FBGs offer advantages such as enhanced reflectivity, shorter fabrication time, and simplified spectral characteristics, making them easier to interpret compared with high-order FBGs. The FBGs’ resilience and effectiveness are analyzed by subjecting them to temperature tests, proving their capacity for accurate temperature monitoring up to 1500°C—a testament to their suitability for harsh environments. This novel approach broadens the scope for sensing and communication applications in sapphire fibers, particularly under challenging conditions. The novelty of our work lies in successfully overcoming the limitations of previous designs by integrating a cascade of 10 FBGs in sapphire fibers, thereby enhancing multiplexing capabilities, minimizing overlapping of FBG peaks, and ensuring reliable temperature monitoring in industries and applications with thermal gradients.

47 OTHER INSTRUMENTATION↗

Photo-oxidation of semicrystalline polymers: Effect of stress triaxiality on ductility

The effect of stress triaxiality on the strain-to-fracture of as-received and photo-oxidized polyamide-6 (PA-6) was investigated using mechanical testing, synchrotron X-ray tomography, and finite element analyses. Mechanical tests were conducted on cylindrical and round notched specimens, where different notch radii were used to vary the stress triaxiality. The specimens were aged by exposure to ultra-violet (UV) radiation at 60∘, causing photo-oxidation. As-received and so-aged specimens were loaded to failure (complete loss of load carrying capacity). For both unaged and aged specimens, a higher triaxiality led to a lower strain-to-fracture. To elucidate the micromechanical damage that mediates fracture in both conditions, specimens with an intermediate notch sharpness were loaded to the peak load, unloaded, and scanned ex situ using synchrotron X-ray tomography. Damage in the unaged bar was found to occur by cavitation and was concentrated at the center of the specimen, where the triaxiality is highest. In the UV-aged bar, a network of inter-connected chemical cracks were found on the notch surface, where the triaxiality is lowest. Finite element analyses were deployed to approximate the local triaxiality at damaged regions in the unaged and UV-aged specimens using a constitutive relation for semicrystalline polymers. From these analyses, the relationship between local triaxiality and strain-to-fracture was quantified for both unaged and photo-oxidized PA-6. Both unaged and photo-oxidized PA-6 showed similar decreases in ductility with triaxiality, hinting at common ductile fracture processes.

36 MATERIALS SCIENCE↗

A Durable, Inexpensive and Scalable Redox Flow Battery Based on Iron Sulfate and Anthraquinone Disulfonic Acid

A new redox flow battery system based on iron sulfate and anthraquinone disulfonic acid (AQDS) is shown here to have excellent electrical performance, capacity retention, and chemical durability. While these redox couples, iron(II)/iron(III) and AQDS are well known individually, their combination in a redox flow battery is shown here for the first time to provide unique benefits for large-scale energy storage. Based on iron sulfate, a waste product of the steel industry, the active materials cost for this battery is anticipated to be $66/kWh. Cycling studies of over 500 cycles in the symmetric cell configuration show a negligibly low capacity fade rate of 7.6 × 10 −5 % per cycle. This symmetric cell also shows a notably high average coulombic efficiency of 99.63%. Using a graphite felt electrode modified with multi-walled carbon nanotubes (MWCNTs), we could achieve a peak power density of 194 mW cm −2 . The major voltage losses are ascribed to the ohmic resistance of the electrode and electrolyte. Despite the lower cell voltage of the system relative to the vanadium flow battery, the iron–AQDS flow battery system presents a good prospect for simultaneously meeting the demanding requirements of cost, durability and scalability for large-scale sustainable energy storage.

Yang, Bo↗

The growth of the UniTree mass storage system at the NASA Center for Computational Sciences: Some lessons learned

In October 1992, the NASA Center for Computational Sciences made its Convex-based UniTree system generally available to users. The ensuing months saw growth in every area. Within 26 months, data under UniTree control grew from nil to over 12 terabytes, nearly all of it stored on robotically mounted tape. HiPPI/UltraNet was added to enhance connectivity, and later HiPPI/TCP was added as well. Disks and robotic tape silos were added to those already under UniTree's control, and 18-track tapes were upgraded to 36-track. The primary data source for UniTree, the facility's Cray Y-MP/4-128, first doubled its processing power and then was replaced altogether by a C98/6-256 with nearly two-and-a-half times the Y-MP's combined peak gigaflops. The Convex/UniTree software was upgraded from version 1.5 to 1.7.5, and then to 1.7.6. Finally, the server itself, a Convex C3240, was upgraded to a C3830 with a second I/O bay, doubling the C3240's memory and capacity for I/O. This paper describes insights gained and reinforced with the burgeoning demands on the UniTree storage system and the significant increases in performance gained from the many upgrades.

Tarshish, Adina↗

A new ductile, tougher resin for impregnation of superconducting magnets

A major remaining challenge for Nb 3 Sn high field magnets is their training due to random temperature variations in the coils. The main objective of our research is to reduce or eliminate it by finding novel impregnation materials in replacement of the epoxies currently used. An organic olefin-based thermosetting dicyclopentadiene resin, C 10 H 12 , commercially available in Japan as TELENE® by RIMTEC, was used to impregnate a short Nb 3 Sn undulator coil developed by ANL and FNAL. This magnet reached short sample limit after only two quenches, compared with ∼100 when CTD-101K® was used. Ductility, i.e. the ability to accept large strains, and toughness were identified as key properties to achieve these results. In addition, we have been investigating whether mixing TELENE with high heat capacity ceramic powders such as Gd 2 O 3 , Gd 2 O 2 S, and HoCu 2 , increases the specific heat (C p ) of impregnated Nb3Sn superconducting magnets. The viscosity, heat capacity, thermal conductivity, and other physical properties of TELENE with high-C p powder fillers were measured in this study as a function of temperature and magnetic field. The TELENE-87 wt%Gd 2 O 2 S had a peak in C p between 4.3 K and 5.3 K at fields between 0 and 8 T. We have also investigated the effect on the mechanical properties of pure and mixed TELENE under 10 MGy of gamma ray irradiation at the Takasaki Advanced Radiation Research Institute in Takasaki, Japan. TELENE-87 wt%Gd 2 O 2 S exhibited exceptional radiation resistance. Impregnating an undulator coil with TELENE mixed with Gd 2 O 2 S powder will verify whether the coils' thermal stability further improves, or whether its low diffusivity will require engineering the material with high-thermal conductivity components. Short magnet training will lead to better magnet reliability, lower magnet margins, lower risk and substantial saving in accelerators' commissioning costs. Part of this study is supported by the U.S.-Japan Science and Technology Cooperation Program in high energy physics operated by MEXT in Japan and DOE in the U.S.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

The Jet Propulsion Laboratory low-cost solar array project, 1974-1986

The overall objective of the photovoltaic program is to ensure that photovoltaic conversion systems play a significant role in the nation's energy supply by stimulating an industry capable of providing approximately 50 GWe of installed electricity generating capacity by the year 2000. In order to achieve this overall objective, several time-phased program goals have been defined. Near-term goals are to achieve photovoltaic flat-plate module or concentrator array prices of $2 per peak watt (1975 dollars) at an annual production rate of 20 peak megawatts in 1982. At this price level, energy costs should range from 100 to 200 mills/kwh. Mid-term goals are to achieve photovoltaic flat-plate module or concentrator array prices of $0.50 per peak watt (in 1975 dollars), and an annual production rate of 500 peak megawatts in 1986. Studies project that photovoltaic systems will begin to compete for both distributed and larger load-center utility-type applications and thereby open up significant markets for large-scale photovoltaic systems. Far term goals are to achieve the photovoltaic flat-plate module or concentrator array price goal of $0.10 to $0.30 per peak watt in 1990 (in 1975 dollars), and an annual production rate of 10 to 20 peak gigawatts in 2000. At this price range, energy cost should be in the range of 40 to 60 mills. kwh and be cost effective for utility applications. Achievement of these goals can make photovoltaic systems economically competitive with other energy sources for dispersed on-site applications as well as for central power generation.

Maycock, P. D.↗