Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Preliminary Report on Optical Seeing Tests at Mt. Lemmon, March - June 1971

One of the Lick Observatory Polaris telescopes was used to test seeing conditions at Mt. Lemmon. The preliminary results indicate that the seeing is not unlike that at Kitt Peak. Soundings of the air flow patterns across Mt. Lemmon under winter conditions were also made by flying smoke pots on tethered ballons to elevations of 500 feet. There does not appear to be any serious local turbulence.

Coyne, G. V.↗

Far-field radiation of aft turbofan noise

Approximate expressions were developed for the noise radiation from the aft duct. The results of approximate aft radiation equation compare favorably to more exact Wiener-Hopf radiation results. Refraction as well as convective effects in the multiple flow streams is considered. The peak in the radiation pattern, which occurs nearly at engine sideline, is composed of modes with relatively large cut-off ratios. This implies that aft fan radiation will be inherently more difficult to suppress that the fan inlet noise. The theoretical multimodal radiation pattern is compared to experimental data for the first two harmonics of blade passage frequency for three full scale fans at two speeds. The agreement between theory and experiment is quite good.

Rice, E. J.↗

Electrostatic discharging behaviour of Kapton irradiated with electrons

The electrostatic charging and discharging of Kapton when irradiated with monoenergetic electrons of 5 to 30 keV energy were studied. The leakage currents and rates of discharging always increased with the incident electron energy and flux, whereas the surface voltage showed a more complex behavior depending on the thickness of the material: for the thinner films it exhibited a maximum and then fell at higher energies. The surface voltage, the rate of discharging, and the peak current and total charge flow during a discharge were enhanced as the temperature was decreased from 70 C to -180 C, and were accompanied by a decreasing leakage current. Visible light or the presence of an aluminum coating on the irradiated surface caused reductions in the surface voltage and changes in the discharging characteristics. The results are discussed in terms of the leakage currents and the secondary emission of electrons. Photomicrographs taken after irradiation, and photographs of samples during irradiation, show good correlations between the positions of light flashes and of pinholes produced by the discharge arcs.

Verdin, D.↗

The use of laterally vectored thrust to counter thrust asymmetry in a tactical jet aircraft

A nonlinear, six degree-of-freedom flight simulator for a twin engine tactical jet was built on a hybrid computer to investigate lateral vectoring of the remaining thrust component for the case of a single engine failure at low dynamic pressures. Aircraft control was provided by an automatic controller rather than a pilot, and thrust vector control was provided by an open-loop controller that deflected a vane (located on the periphery of each exhaust jet and normally streamlined for noninterference with the flow). Lateral thrust vectoring decreased peak values of lateral control deflections, eliminated the requirement for steady-state lateral aerodynamic control deflections, and decreased the amount of altitude lost for a single engine failure.

Source record↗

Development of software to improve AC power quality on large spacecraft

To insure the reliability of a 20 kHz, AC power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can cause malfunctions in equipment that the power system is supplying, and during extreme distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. HARMFLO, a power flow computer program, which was capable of analyzing harmonic conditions on three phase, balanced, 60 Hz, AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The results are that (1) the harmonic power now has a model of a single phase, voltage controlled, full wave rectifier; and (2) HARMFLO was ported to the SUN workstation platform.

Kraft, L. Alan↗

Performance of a Supersonic Ramp-type Side Inlet with Ram-scoop Throat Bleed and Varying Fuselage Boundary-layer Removal : Mach Number Range 1.5 to 2.0 / Glenn A. Mitchell and Robert C. Campbell

Provided sufficient throat bleed was employed, maximum pressure recoveries of 0.87 to 0.88 at Mach number 2.0 were obtained for a fuselage-mounted 14 degrees ramp inlet regardless of the amount of fuselage boundary layer ingested. The addition of inlet side fairings yielded further increases in pressure recovery to 0.90 to 0.91, decreased critical drag coefficients, and increased critical mass-flow ratios. With throat bleed, peak pressure recoveries and calculated thrust-minus-drag values were comparable at two axial positions of the scoop and were highest with the greatest amount of fuselage boundary layer ingested.

Mitchell, Glenn A↗

An implementation of a chemical and thermal nonequilibrium flow solver on unstructured meshes and application to blunt bodies

This paper presents a nonequilibrium flow solver, implementation of the algorithm on unstructured meshes, and application to hypersonic flow past blunt bodies. Air is modeled as a mixture of five chemical species, namely O2, N2, O, NO, and N, having two temperatures namely translational and vibrational. The solution algorithm is a cell centered, point implicit upwind scheme that employs Roe's flux difference splitting technique. Implementation of this algorithm on unstructured meshes is described. The computer code is applied to solve Mach 15 flow with and without a Type IV shock interference on a cylindrical body of 2.5mm radius representing a cowl lip. Adaptively generated meshes are employed, and the meshes are refined several times until the solution exhibits detailed flow features and surface pressure and heat flux distributions. Effects of a catalytic wall on surface heat flux distribution are studied. For the Mach 15 Type IV shock interference flow, present results showed a peak heat flux of 544 MW/m2 for a fully catalytic wall and 431 MW/m(exp 2) for a noncatalytic wall. Some of the results are compared with available computational data.

Prabhu, Ramadas K.↗

Atmospheric Pressure Effects on Cryogenic Storage Tank Boil-Off

The Cryogenics Test Laboratory (CTL) at the Kennedy Space Center (KSC) routinely utilizes cryostat test hardware to evaluate comparative and absolute thermal conductivities of a wide array of insulation systems. The test method is based on measurement of the flow rate of gas evolved due to evaporative boil-off of a cryogenic liquid. The gas flow rate typically stabilizes after a period of a couple of hours to a couple of days, depending upon the test setup. The stable flow rate value is then used to calculate the thermal conductivity for the insulation system being tested. The latest set of identical cryostats, 1,000-L spherical tanks, exhibited different behavior. On a macro level, the flow rate did stabilize after a couple of days; however the stable flow rate was oscillatory with peak to peak amplitude of up to 25 percent of the nominal value. The period of the oscillation was consistently 12 hours. The source of the oscillation has been traced to variations in atmospheric pressure due to atmospheric tides similar to oceanic tides. This paper will present analysis of this phenomenon, including a calculation that explains why other cryostats are not affected by it.

Sass, J. P.↗

Aeroacoustics of Three-Stream Jets

Results from acoustic measurements of noise radiated from a heated, three-stream, co-annular exhaust system operated at subsonic conditions are presented. The experiments were conducted for a range of core, bypass, and tertiary stream temperatures and pressures. The nozzle system had a fan-to-core area ratio of 2.92 and a tertiary-to-core area ratio of 0.96. The impact of introducing a third stream on the radiated noise for third-stream velocities below that of the bypass stream was to reduce high frequency noise levels at broadside and peak jet-noise angles. Mid-frequency noise radiation at aft observation angles was impacted by the conditions of the third stream. The core velocity had the greatest impact on peak noise levels and the bypass-to-core mass flow ratio had a slight impact on levels in the peak jet-noise direction. The third-stream jet conditions had no impact on peak noise levels. Introduction of a third jet stream in the presence of a simulated forward-flight stream limits the impact of the third stream on radiated noise. For equivalent ideal thrust conditions, two-stream and three-stream jets can produce similar acoustic spectra although high-frequency noise levels tend to be lower for the three-stream jet.

Henderson, Brenda↗

Aeroacoustics of Three-Stream Jets

Results from acoustic measurements of noise radiated from a heated, three-stream, co-annular exhaust system operated at subsonic conditions are presented. The experiments were conducted for a range of core, bypass, and tertiary stream temperatures and pressures. The nozzle system had a fan-to-core area ratio of 2.92 and a tertiary-to-core area ratio of 0.96. The impact of introducing a third stream on the radiated noise for third-stream velocities below that of the bypass stream was to reduce high frequency noise levels at broadside and peak jet-noise angles. Mid-frequency noise radiation at aft observation angles was impacted by the conditions of the third stream. The core velocity had the greatest impact on peak noise levels and the bypass-to-core mass flow ratio had a slight impact on levels in the peak jet-noise direction. The third-stream jet conditions had no impact on peak noise levels. Introduction of a third jet stream in the presence of a simulated forward-flight stream limits the impact of the third stream on radiated noise. For equivalent ideal thrust conditions, two-stream and three-stream jets can produce similar acoustic spectra although high-frequency noise levels tend to be lower for the three-stream jet.

Henderson, Brenda S.↗

Hazard Assessment from Storm Tides and Rainfall on a Tidal River Estuary

Here, we report on methods and results for a model-based flood hazard assessment we have conducted for the Hudson River from New York City to Troy/Albany at the head of tide. Our recent work showed that neglecting freshwater flows leads to underestimation of peak water levels at up-river sites and neglecting stratification (typical with two-dimensional modeling) leads to underestimation all along the Hudson. As a result, we use a three-dimensional hydrodynamic model and merge streamflows and storm tides from tropical and extratropical cyclones (TCs, ETCs), as well as wet extratropical cyclone (WETC) floods (e.g. freshets, rain-on-snow events). We validate the modeled flood levels and quantify error with comparisons to 76 historical events. A Bayesian statistical method is developed for tropical cyclone streamflows using historical data and consisting in the evaluation of (1) the peak discharge and its pdf as a function of TC characteristics, and (2) the temporal trend of the hydrograph as a function of temporal evolution of the cyclone track, its intensity and the response characteristics of the specific basin. A k-nearest-neighbors method is employed to determine the hydrograph shape. Out of sample validation tests demonstrate the effectiveness of the method. Thus, the combined effects of storm surge and runoff produced by tropical cyclones hitting the New York area can be included in flood hazard assessment. Results for the upper Hudson (Albany) suggest a dominance of WETCs, for the lower Hudson (at New York Harbor) a case where ETCs are dominant for shorter return periods and TCs are more important for longer return periods (over 150 years), and for the middle-Hudson (Poughkeepsie) a mix of all three flood events types is important. However, a possible low-bias for TC flood levels is inferred from a lower importance in the assessment results, versus historical event top-20 lists, and this will be further evaluated as these preliminary methods and results are finalized. Future funded work will quantify the influences of sea level rise and flood adaptation plans (e.g. surge barriers). It would also be valuable to examine how streamflows from tropical cyclones and wet cool-season storms will change, as this factor will dominate at upriver locations.

Hazard assessment↗

BORE II

Bore II, co-developed by Berkeley Lab researchers Frank Hale, Chin-Fu Tsang, and Christine Doughty, provides vital information for solving water quality and supply problems and for improving remediation of contaminated sites. Termed "hydrophysical logging," this technology is based on the concept of measuring repeated depth profiles of fluid electric conductivity in a borehole that is pumping. As fluid enters the wellbore, its distinct electric conductivity causes peaks in the conductivity log that grow and migrate upward with time. Analysis of the evolution of the peaks enables characterization of groundwater flow distribution more quickly, more cost effectively, and with higher resolution than ever before. Combining the unique interpretation software Bore II with advanced downhole instrumentation (the hydrophysical logging tool), the method quantifies inflow and outflow locations, their associated flow rates, and the basic water quality parameters of the associated formation waters (e.g., pH, oxidation-reduction potential, temperature). In addition, when applied in conjunction with downhole fluid sampling, Bore II makes possible a complete assessment of contaminant concentration within groundwater.

Source record↗

Reentry heating analysis of space shuttle with comparison of flight data

Surface heating rates and surface temperatures for a space shuttle reentry profile were calculated for two wing cross sections and one fuselage cross section. Heating rates and temperatures at 12 locations on the wing and 6 locations on the fuselage are presented. The heating on the lower wing was most severe, with peak temperatures reaching values of 1240 C for turbulent flow and 900 C for laminar flow. For the fuselage, the most severe heating occured on the lower glove surface where peak temperatures of 910 C and 700 C were calculated for turbulent flow and laminar flow, respectively. Aluminum structural temperatures were calculated using a finite difference thermal analyzer computer program, and the predicted temperatures are compared to measured flight data. Skin temperatures measured on the lower surface of the wing and bay 1 of the upper surface of the wing agreed best with temperatures calculated assuming laminar flow. The measured temperatures at bays two and four on the upper surface of the wing were in quite good agreement with the temperatures calculated assuming separated flow. The measured temperatures on the lower forward spar cap of bay four were in good agreement with values predicted assuming laminar flow.

Gong, L.↗

Kinetic modeling of O(+) upflows resulting from E x B convection heating in the high-latitude F region ionosphere

We report here the results of modeling work aimed at understanding the development of ionospheric O(+) field-aligned upflows that develop in response to high-latitude E x B drift induced frictional heating. The model used is a collisional semikinetic model which includes ion-neutral resonant charge exchange and polarization collisions as well as Coulomb self-collisions. It also includes the process of chemical removal of O(+) as well as all of the macroscopic forces: ambipolar electric, gravity, magnetic mirror, and centripetal. Model results show the development of several types of non-Maxwellian velocity distributions including toroids at low altitude, distributions with large heat flow in the perpendicular component at intermediate altitudes, and distributions with a separate upflowing population or upward superthermal tail at high altitudes. Whenever the convection electric field increases from a small value (less than 25 mV/m) to a large value (100-200 mV/m) in 6 min or less large upflows develop with parallel drift speeds which peak (below 1000 km) at values between 500 m/s and 2 km/s, parallel fluxes which peak between 6.0 x 10(exp 8) and 3.2 x 10(exp 9)/sq cm/s, and parallel per particle heat flows which peak between 8.0 x 10(exp -9) and 8.0 x 10(exp -8) ergs cm/s. The higher values in these ranges occur for a cooler neutral atmosphere, with a larger convection electric field that is turned on quickly. The model produces field-aligned O(+) flow speeds that are larger than those produced by a 20-moment generalized transport model but smaller then those produced by an isotropic hydrodynamic model for comparable values of the convection turn on times. The model results compare favorably with some topside satellite and radar data.

Wilson, G. R.↗

AFR-100 safety analyses

The Advanced Fast Reactor-100 (AFR-100) is Argonne National Laboratory's 250 MWth metal-fueled modular sodium-cooled pool-type fast reactor concept. [1] A series of accident sequences that focused on the AFR-100's ability to provide protection against reactor damage during low probability accident sequences resulting from multiple equipment failures were examined. Protected and Unprotected Loss of Flow (PLOF and ULOF) and Unprotected Transient Over-Power (UTOP) accidents were simulated using the SAS4A/SASSYS-1 safety analysis code. The large heat capacity of the sodium in the pool-type reactor allows the AFR-100 to absorb large amounts of energy during a PLOF with relatively small temperature increases throughout the system. During a ULOF with a 25-second flow halving time, coolant and cladding temperatures peak around 720 deg. C within the first minute before reactivity feedback effects decrease power to match the flow. Core radial expansion and fuel Doppler provide the necessary feedback during the UTOP to bring the system back to critical before system temperatures exceed allowable limits. Simulation results indicate that adequate ULOF safety margins exist for the AFR-100 design with flow halving times of twenty-five seconds. Significant safety margins are maintained for PLOF accidents as well as UTOP accidents if a rod stop is used. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of turbulent correlations in supersonic flows with longitudinal surface curvature

The effect of longitudinal surface curvature on the turbulent correlations of a supersonic turbulent boundary layer was studied experimentally in an axisymmetric channel. Upstream of the interaction, the nominal freestream Mach number was 3.78, the Reynolds number based on boundary layer momentum thickness was 5778, and the boundary layer thickness was 0.9 cm. For the flow with the longitudinal surface curvature, the overall turning angle was approximately 10.2 degrees, and maximum delta-j/kappa approximately 0.09. The shear stresses, measured by a hot wire anemometry, reached the peak values quite rapidly for the flow with surface curvature as compared to the corresponding flow without surface curvature.

Chou, J. H.↗

Experimental evaluation of a translating nozzle sidewall radial turbine

An experimental performance evaluation was made of two movable sidewall variable area radial turbines. The turbine designs were representative of the gas generator turbine of a variable flow capacity rotorcraft engine. The first turbine was an uncooled design while the second turbine had a cooled nozzle but an uncooled rotor. The cooled nozzle turbine was evaluated both with and without coolant flow. The test results showed that the movable nozzle wall is a viable and efficient means to effectively control the flow capacity of a radial turbine. Peak efficiencies of the second turbine with and without nozzle coolant were 86.5 and 88 percent respectively. These values are comparable to pivoting vane variable geometry turbines; however, the decrease in efficiency as the flow was varied from the design value was much less for the movable wall turbine. Several design improvements which should increase the turbine efficiency one or two more points are identified. These design improvements include reduced leakage losses and relocation of the vane coolant ejection holes to reduce mainstream disturbance.

Roelke, Richard J.↗