Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Weather aging effects on modified asphalt with rubber-polyethylene composites

Weather aging may cause more severe degradation on asphalt than thermal-oxidative aging due to the synergistic effect among oxygen, heat, ultraviolet (UV) radiation, and moisture. This study aimed to investigate weather aging effects and anti-aging mechanisms on asphalt modified with rubber-polyethylene (PE) composites. The modified binder blends and asphalt mixtures were subjected to outdoor weather aging. Dynamic shear rheometer (DSR), Fourier transform infrared spectroscopy (FTIR), Gel permeation chromatography (GPC), and optical microscopy tests were adopted to characterize the rheological properties, aging resistance, polymer degradation, and anti-aging mechanisms of modified binder blends, respectively. Mixture performance tests including Asphalt Pavement Analyzer (APA) and Ideal-CT tests were used to evaluate rutting and cracking resistance of asphalt mixtures. Results showed that weather aging can cause more severe aging to asphalt binders than pressure aging vessel (PAV) due to the severe degradation of PE particles. Rubber-PE composites alloyed with an extruder proved to stabilize PE particles in asphalt and significantly improve the aging resistance of modified binder blends. Furthermore, the enhanced aging resistance is attributed to the dispersion of PE particles and carbon black released by soluble rubbers.

Aging resistance↗

PACT Center: Perovskite PV Accelerator for Commercializing Technologies (Final Technical Report)

The Perovskite PV Accelerator for Commercializing Technologies (PACT) center was established in July 2021 as a national resource to accelerate the commercialization of perovskite photovoltaic (PV) technology in the United States. Since its inception, PACT has been led by Sandia National Laboratories (Sandia) in partnership with the National Laboratory of the Rockies (NLR), formerly known as NREL. From FY20-FY23, Los Alamos National Laboratory (LANL), CFV Labs, Black & Veatch (B&V), and the Electric Power Research Institute (EPRI) were part of the project team. LANL brought expertise in perovskite PV device designs and processing, CFV Labs (now GroundWork Renewables) provided initial indoor and outdoor measurement hardware technology, B&V led the initial effort on perovskite PV bankability, and EPRI worked on reviewing testing standards, identifying commercialization gaps, and helping to run PACT’s Industry Advisory Board, a group including representatives from commercial testing labs, independent engineering firms, insurance companies, state regulators, and electric utilities. To source perovskite PV module samples, PACT contracted with the University of North Carolina (UNC), the University of Toledo, the University of Washington, and SLAC/Stanford University to provide a steady stream of research-grade perovskite mini modules, enabling protocol development in advance of commercial module availability. The project period ran from July 1, 2021, through December 31, 2025, including a No Cost Extension. Starting in FY25, the project was continued as a Core Capability in the Lab Call portfolio and continues at a reduced budget with only Sandia and NLR as funded recipients. Notably, starting in FY25 PACT expanded its scope beyond MHP modules to accept all emerging PV mini module technologies for testing, including organic PV (OPV) and all-thin-film tandems, with the aim of supporting commercialization across the broader emerging PV ecosystem. With this change in scope the program was renamed the PV Accelerator for Commercializing Technologies, dropping perovskite from the name.

14 SOLAR ENERGY↗

Wideband propagation measurement system using spread spectrum signaling and TDRS

In this paper, a wideband propagation measurement system, which consisted of a ground-based transmitter, a mobile receiver, and a data acquisition system, was constructed. This system has been employed in a study of the characteristics of different propagation environments, such as urban, suburban and rural areas, by using a pseudonoise spreading sequence transmitted over NASA's Tracking and Data Relay Satellite System. The hardware and software tests showed that it met overall system requirements and it was very robust during a 3-month-long outdoor data collection experiment.

Jenkins, Jeffrey D.↗

NFE-24-10417: Durability and Life-time Energy Performance Enhancement of Vapor Compression Systems

This project investigated the use of a Centrifugal Particle Separation (CPS) system to improve the durability and operational reliability of outdoor heat exchangers in vapor-compression based heating, ventilation, air conditioning, and refrigeration (HVACR) systems. The developed method introduced a novel dust and fouling mitigation approach by integrating an ambient air pre-cleaner that employs centrifugal forces to remove particulate matter from incoming air before it reaches the heat exchanger. By reducing the accumulation of dust and debris on coil surfaces, the CPS system aims to lower maintenance requirements and extend equipment lifespan. The project specifically involves coupling a centrifugal air pre-cleaner with a single-zone ductless mini-split system and evaluating its effectiveness in maintaining cleaner coil surfaces. Additionally, the study examined the impact of CPS integration on system energy performance. Through controlled experimental testing and performance monitoring, this work seeks to validate CPS-based air pre-cleaning as a practical, efficient solution for mitigating outdoor coil dust accumulation and fouling in both residential and commercial HVACR applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Encapsulation of PV cells using silicone materials

The use of silicone materials as thin conformal coatings for the protection of photovoltaic cells is investigated. Five silicone materials ranging from soft elastomers to high modulus resins were evaluated after exposure to UV radiation, outdoor weathering, thermal cycling at high humidity and temperature cycling from -40 C to 90 C. The effects of these tests were monitored by periodically measuring the output of two-cell circuit strings encapsulated with the various materials, and one exceptional silicone coating for which no significant changes in cell output were noted after 300 days was chosen as the best of the candidates. Because only a thin coating of the substance is needed, material costs 60% lower than those of previous encapsulants are now possible.

Dennis, W. E.↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

US terrestrial solar cell calibration and measurement procedures

A workshop was held in the fall of 1976, to evaluate and revise interim terrestrial solar cell calibration and measurement procedures. The revisions made to the interim testing procedures are described. The calibration of reference cells and the design of their holders are covered. Considerations include view angle and optical and thermal matching. Atmospheric factors which affect the calibration and performance of solar cells are discussed. The most critical atmospheric parameter appears to be water vapor. Techniques for matching reference cells to cells or arrays under test are described. Data showing errors in performance under artificial sunlight simulators due to mismatch of reference and test cells are presented. Finally, measurement procedures and data transformations needed to obtain the performance of solar cells and arrays in outdoor natural sunlight are described.

Brandhorst, H. W., Jr.↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Thermal model to quantify the impact of sub-bandgap reflectance on operating temperature of fielded PV modules

Minimizing module heating is an effective way to increase the lifetime energy output of photovoltaic systems. Maximizing the reflection of light that is unusable for energy conversion is one of the most promising ways to reduce the operating temperature of fielded modules. We derive a model based on a steady-state energy balance to quantify the temperature benefit of cell or module optical modifications aimed at improving reflection of light with photon energies below the photovoltaic cell bandgap energy. This more detailed model is then simplified so that, from outdoor measured data, temperature differences arising from reflectance can be isolated from those arising from irradiance, wind speed, and module standard-test-condition efficiency.

14 SOLAR ENERGY↗

Suspended Membrane Evaporators Integrating Environmental and Solar Evaporation for Oily Wastewater Purification

Solar-driven evaporation is promising in oily wastewater treatment, in particular for emulsions, but conventional evaporators suffer from pore blocking by residual oil or contamination by volatile oil compounds in the condensed water. In the current research, we develop a suspended membrane evaporator integrating solar evaporation with oil-in-water emulsion separation. The heating and evaporating interface is separated from the rejecting interface to avoid oil escape and improve heat management. A temperature gradient forms on the membrane surface that can promote evaporation performance by combining both solar and environmental evaporation. Such an evaporator achieves a maximum evaporation rate of 1.645 kg/(m 2 ·h) as well as an apparent evaporation efficiency of 111.9%. Moreover, the superhydrophilic and superoleophobic membrane shows excellent oil repellence and emulsion rejection, which can achieve an oil removal efficiency above 98.8% in oil-in-water emulsion separation, and high evaporation rate recovery in cycling tests. Furthermore, a scaled-up membrane evaporator array produces ~8 kg/(m 2 ·d) of clean water from oily wastewater in outdoor experiments, further demonstrating the strong purification performance of this evaporator in oily wastewater treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

External stress-corrosion cracking of a 1.22-m-diameter type 316 stainless steel air valve

An investigation was conducted to determine the cause of the failure of a massive AISI Type 316 stainless steel valve which controlled combustion air to a jet engine test facility. Several through-the-wall cracks were present near welded joints in the valve skirt. The valve had been in outdoor service for 18 years. Samples were taken in the cracked regions for metallographic and chemical analyses. Insulating material and sources of water mist in the vicinity of the failed valve were analyzed for chlorides. A scanning electron microscope was used to determine whether foreign elements were present in a crack. On the basis of the information generated, the failure was characterized as external stress-corrosion cracking. The cracking resulted from a combination of residual tensile stress from welding and the presence of aqueous chlorides. Recommended countermeasures are included.

Moore, Thomas J.↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Analysis of the measured effects of the principal exhaust effluents from solid rocket motors

The feasibility of conducting environmental chamber tests using a small rocket motor to study the physical processes which occur when the exhaust products from solid motors mix with the ambient atmosphere was investigated. Of particular interest was the interaction between hydrogen chloride, aluminum oxide, and water vapor. Several types of instruments for measuring HCl concentrations were evaluated. Under some conditions it was noted that acid aerosols were formed in the ground cloud. These droplets condensed on Al2O3 nuclei and were associated with the rocket exhaust cooling during the period of plume rise to stabilization. Outdoor firings of the solid rocket motors of a 6.4 percent scaled model of the space shuttle were monitored to study the interaction of the exhaust effluents with vegetation downwind of the test site. Data concerning aluminum oxide particles produced by solid rocket motors were evaluated.

Dawbarn, R.↗

UV‐induced degradation of high‐efficiency silicon PV modules with different cell architectures

Abstract Degradation from ultraviolet (UV) radiation has become prevalent in the front of solar cells due to the introduction of UV‐transmitting encapsulants in photovoltaic (PV) module construction. Here, we examine UV‐induced degradation (UVID) in various commercial, unencapsulated crystalline silicon cell technologies, including bifacial silicon heterojunction (HJ), interdigitated back contact (IBC), passivated emitter and rear contact (PERC), and passivated emitter rear totally diffused (PERT) solar cells. We performed UV exposure tests using UVA‐340 fluorescent lamps at 1.24 W·m −2 (at 340 nm) and 45°C through 4.02 MJ·m −2 (2000 h). Our results showed that modern cell architectures are more vulnerable to UVID, leading to a significant power decrease (−3.6% on average; −11.8% maximum) compared with the conventional aluminum back surface field (Al‐BSF) cells (<−1% on average). The power degradation is largely caused by the decrease in short‐circuit current and open‐circuit voltage. A greater power decrease is observed in bifacial cells with rear‐side exposure compared with those with front‐side exposure, indicating that the rear side is more susceptible to UV damage. Secondary ion mass spectroscopy (SIMS) confirmed an increase in hydrogen concentration near the Si/passivation interface in HJ and IBC cells after UV exposure; the excess of hydrogen could result in hydrogen‐induced degradation and subsequently cause higher recombination losses. Additionally, surface oxidation and hot‐carrier damage were identified in PERT cells. Using a spectral‐based analysis, we obtained an acceleration factor of 5× between unpackaged cells (containing a silicon nitride antireflective coating on the front) in the UV test and an encapsulated module (with the front glass and encapsulant blocking 90% of the UV at 294 nm and 353 nm, respectively) in outdoor conditions. From the analytical calculations, we show that a UV‐blocking encapsulant can reduce UV transmission in the module by an additional factor of ~50.

14 SOLAR ENERGY↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey of long-term durability of fiberglass reinforced plastic structures

Included are fluid containment vessels, marine structures, and aircraft components with up to 19 years of service. Correlations were obtained for the variation of static fatigue strength, cyclic fatigue strength, and residual burst strength for pressure vessels. In addition, data are presented for the effects of moisture on strength retention. Data variations were analyzed, and relationships and implications for testing are discussed. Change in strength properties for complete structures was examined for indications of the effects of environmental conditions such as moisture and outdoor exposure (ultraviolet radiation, weathering) on long term durability.

Lieblein, S.↗

Shaker Table Test Plan

Currently, spent nuclear fuel (SNF) is stored in onsite independent spent fuel storage facilities (ISFSIs), which is a dry storage facility, at 55 nuclear power plant sites. The majority of SNF in dry storage is in welded metal canisters (2,917 canisters at the end of 2019). The canisters are loaded for storage in storage overpacks (vertical casks or horizontal storage modules) and placed on outdoor concrete pads. Because the SNF will be stored at ISFSIs for an extended period of time, there is growing concern with regards to the behavior of the SNF within these dry storage systems during earthquakes. To address these concerns, the SFWST program is considering conducting an earthquake shaker table test. The goal of this test is to determine the strains and accelerations on fuel assembly hardware and cladding during earthquakes of different magnitudes to better quantify the potential damage an earthquake could inflict on spent nuclear fuel rods. The seismic integrity of the storage system has been addressed in the past by the US Nuclear Regulatory Commission and is not the focus of this potential test. Instead the DOE would benefit from knowing the condition of the fuel cladding from storage, transportation, to disposal so that it can ascertain repository performance for the fuel and packaging in its final state. A seismic event is part of the possible loading events that the fuel could experience in its lifetime. This report proposes several earthquake shaker table tests with different degrees of complexity. Alternative 1 was defined in the FY20 work scope. Alternatives 2 and 3 were recently developed to take advantage of the NUHOMS 32PTH dry storage canister that may be available in FY21 for this test at a minimum cost to the project. The selection of the alternative(s) will depend on the available budget and the SFWST program priorities for the near future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photovoltaic Inverter Failure Mechanism Estimation Using Unsupervised Machine Learning and Reliability Assessment

This article introduces a data-driven approach to assessing failure mechanisms and reliability degradation in outdoor photovoltaic (PV) string inverters. The manufacturer's stated PV inverter lifetime can vary due to the impact of operating site conditions. To address limitations in degradation estimation through accelerated testing, condition monitoring, or degradation modeling, we propose a machine learning (ML) oriented approach. Utilizing data from a 1.4 MW PV power plant operational since 2016, with 46 string PV inverters tied to the grid, we employ the unsupervised one-class support vector machine ML technique to analyze inverter and sensor data, capable of classifying humidity cycling and temperature fluctuations as dominant failure mechanisms. Utilizing the anomaly alert relationship and alert details specific to the inverter, the level of PV inverter output is considered as its availability or available reliability. Subsequently, a continuous Markov model is applied to six-month alert data, revealing an average stated reliability of 20% after 20 years of continuous operation. These results support recommendations for time-bound preventive measures to enhance PV inverter reliability under diverse outdoor conditions. Furthermore, the approach provides a nondestructive, top–down, and generalized method for analyzing any commercial PV inverter exposed to outdoor conditions, contingent on the availability of relevant data.

14 SOLAR ENERGY↗