Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

ARES I: WASP-76 b, A Tale of Two HST Spectra

We analyze the transmission and emission spectra of the ultra-hot Jupiter WASP-76 b, observed with the G141 grism of the Hubble Space Telescope’s (HST) Wide Field Camera 3 (WFC3). We reduce and fit the raw data for each observation using the open-source software Iraclis before performing a fully Bayesian retrieval using the publicly available analysis suite TauREx 3. Previous studies of the WFC3 transmission spectra of WASP-76 b found hints of titanium oxide (TiO) and vanadium oxide (VO) or non-gray clouds. Accounting for a fainter stellar companion to WASP-76, we reanalyze this data and show that removing the effects of this background star changes the slope of the spectrum, resulting in these visible absorbers no longer being detected, eliminating the need for a non-gray cloud model to adequately fit the data but maintaining the strong water feature previously seen. However, our analysis of the emission spectrum suggests the presence of TiO and an atmospheric thermal inversion, along with a significant amount of water. Given the brightness of the host star and the size of the atmospheric features, WASP-76 b is an excellent target for further characterization with HST, or with future facilities, to better understand the nature of its atmosphere, to confirm the presence of TiO and to search for other optical absorbers.

79 ASTRONOMY AND ASTROPHYSICS↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K

This work presents a concept and implementation of a calibrated streaked spectral pyrometer (SSP) temperature diagnostic used in dynamically driven shock experiments on a two-stage gas gun. This system relies upon measuring the total system response using a tunable monochromator, a NIST-traceable calibrated power meter, and a SSP. The diagnostic performance is validated against previously measured temperatures of shock driven z-cut quartz at 99 GPa and 93 GPa. The results are found to agree with the literature to within 5% and are discussed in this manuscript. The experimental setup utilizes measurements from multiple SSP systems per sample, providing several independent measurements and substantially increasing confidence in the extrapolated shock driven sample temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Measurement of Laser-Irradiated Metals Using Hyperspectral Imaging

Accurate noncontact surface-temperature measurements during laser-based materials processing remain challenging due to the difficulty of establishing reliable emissivity values as a function of temperature and wavelength. Direct measurement of emissivity is difficult, as the emissivity may be changing constantly in the laser-material interaction region, where the temperature gradients are extreme and surface displacement can complicate the measurement. Here, we present a hyperspectral imaging method using a multiwavelength camera to capture the spectral radiance in eight different bands and fit the wavelength-dependent radiance to Planck’s law. Time-resolved temperature measurements during microsecond pulsed-laser irradiation of a metal plate made of the titanium alloy Ti -6 Al -4 V provide temperature information about the irradiated surface with an estimated accuracy of ± 10 % . The extracted wavelength-dependent emissivity slope compares well with reported results for macroscale titanium melts obtained using IR spectroscopy, which measure temperature without any built-in assumptions about the emissivity. The results are directly applicable to temperature monitoring during welding, additive manufacturing, and semiconductor growth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of explosive-induced fracture in polymethyl methacrylate (PMMA)

The fracture response of geologic materials is of interest for applications, including geothermal energy harnessing and containment of underground explosions. To better understand the explosively induced fracture response of geomaterials, polymethyl methacrylate (PMMA) was used as a transparent rock surrogate to allow imaging of internal shock propagation and fracture growth processes. Experiments were conducted using high-speed shadowgraphy and photon Doppler velocimetry (PDV), which were compared to numerical simulations. Experiments measured fractures produced in 304.8mm × 304.8mm × 304.8mm PMMA cubes with two simultaneously initiated detonators. The cubes were subjected to varying amounts and directions of externally applied uniaxial stresses, including no stress, 2 MPa stress, and 20 MPa stress. The fracture radius as a function of time was extracted from the high-speed videos. Post-test images of the PMMA cubes aided in the determination of three-dimensional effects not directly imaged by the cameras. The surface velocity history and the shock response captured in PDV and the high-speed videos were compared to the simulated explosive-induced shock response. The simulation results indicate that the shock drives the fracture for the first 20 μs corresponding to a fracture radius of approximately 15 mm in the experiments. The gas-driven fracture extent was estimated analytically using an equilibrium stress distribution calculated after the shock wave propagation through the sample. Reduction in the gas pressure due to the leakage of the explosive products through the crack as a function of time was accounted for. In conclusion, the estimated fracture lengths were in agreement with the experimentally observed fracture lengths.

15 GEOTHERMAL ENERGY↗

Mass calibration of DES Year-3 clusters via SPT-3G CMB cluster lensing

We measure the stacked lensing signal in the direction of galaxy clusters in the DarkEnergy Survey Year 3 (DES Y3) redMaPPer sample, using cosmic microwave background (CMB)temperature data from SPT-3G, the third-generation CMB camera on the South PoleTelescope (SPT). Here, we estimate the lensing signal using temperature maps constructed fromthe initial 2 years of data from the SPT-3G 'Main' survey, covering 1500 deg$^{2}$ of the Southernsky. We then use this lensing signal as a proxy for the mean cluster mass of the DES sample. Thethermal Sunyaev-Zel'dovich (tSZ) signal, which can contaminate the lensing signal if notaddressed, is isolated and removed from the data before obtaining the mass measurement. In thiswork, we employ three versions of the redMaPPer catalogue: a Flux-Limited sample containing 8865clusters, a Volume-Limited sample with 5391 clusters, and a Volume&Redshift-Limited sample with4450 clusters. For the three samples, we detect the CMB lensing signal at a significance of12.4σ, 10.5σ and 10.2σ and find the mean cluster masses to be M$_{200m}$ = 1.66±0.13 [stat.]± 0.03 [sys.], 1.97±0.18 [stat.]± 0.05 [sys.],and 2.11±0.20 [stat.]± 0.05 [sys.]×10$^{14}$ M$_{⊙}$, respectively. Thisis a factor of ∼ 2 improvement relative to the precision of measurements with previousgenerations of SPT surveys and the most constraining cluster mass measurements using CMB clusterlensing to date. Overall, we find no significant tensions between our results and masses given byredMaPPer mass-richness scaling relations of previous works, which were calibrated using CMBcluster lensing, optical weak lensing, and velocity dispersion measurements from variouscombinations of DES, SDSS and Planck data. We then divide our sample into 3 redshift and 3richness bins, finding no significant discrepancies with optical weak-lensing calibrated masses inthese bins. We forecast a 5.7% constraint on the mean cluster mass of the DES Y3 sample withthe complete SPT-3G surveys when using both temperature and polarization data and including anadditional ∼ 1400 deg$^{2}$ of observations from the 'Extended' SPT-3G survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Lithium Codoping in Enhancing the Scintillation Yield of Aluminate Garnets

The aim of this work is to clarify the scintillation-yield enhancement in Lu YAG : Pr scintillators obtained by Li codoping via integrated study of the valence state of activators, the preferential site occupancy of Li codopants, and defect structures from experimental and theoretical insights. Here, with Li codoping, the light yield and energy resolution of 10 × 10 × 10 mm 3 Lu YAG : Pr samples are improved from 156000 to 248000 photons/MeV, and 5.3 to 4.3% at 662 keV,respectively.The optical absorption spectra indicate that Li codoping does not induce conversion of stable Pr 3 + to Pr 4 + in Lu YAG : Pr single crystals. Based on the formation energies of substitutional and interstitial Li sites using density-functional-theory (DFT) calculations and the 7 Li nuclear magnetic resonance results, it is shown that the Li ions prefer to dominantly occupy the fourfold coordinated interstitial sites and fourfold coordinated Al sites. The systematic analysis of thermoluminescence glow curves, positron annihilation lifetime spectroscopies, and defect formation energies derived from DFT calculations reveals that the concentration of isolated Lu and Al vacancies as dominant acceptor defects is reduced by Li codoping, whilst the shallow Li i interstitial defects and the deep V O oxygen vacancies are introduced simultaneously. We propose that the lowering of hole trapping at defects resulting from Li codoping contributes to the scintillation-yield enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

O 2 based resonantly ionized photoemission thermometry analysis of supersonic flows

Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.

42 ENGINEERING↗

47 Tuc in Rubin Data Preview 1. Exploring Early LSST Data and Science Potential

We present analyses of the early data from Rubin Observatory’s Data Preview 1 (DP1) for the field of the globular cluster 47 Tuc. The DP1 data set for 47 Tuc includes four nights of observations from the Rubin Commissioning Camera (LSSTComCam), covering multiple bands (ugriy). We address challenges of crowding in the inner region of the cluster and toward the SMC in DP1, and demonstrate improved star–galaxy separation by fitting fifth-degree polynomials to the stellar loci in color–color diagrams and applying multidimensional sigma clipping. We compile a catalog of 3576 probable 47 Tuc member stars selected via a combination of isochrone, Gaia proper-motion, and color–color space matched filtering. We explore the sources of photometric scatter in the 47 Tuc color–color sequence, evaluating contributions from various potential sources, including differential extinction within the cluster. Finally, of the 72 well-characterized variables in the field, we recover three known variable stars, including two RR Lyrae and one eclipsing binary, in the coadd-based object catalog, and identify 62 in the difference image-based object catalog. Although the DP1 lightcurves have sparse temporal sampling, they appear to follow the patterns of densely sampled literature lightcurves well. Despite some data limitations for crowded-field stellar analysis, DP1 demonstrates the promising scientific potential for future LSST data releases.

Choi, Yumi [NSF National Optical-Infrared Astronom↗

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. Here, this paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

High energy density physics↗

Combined thermographic phosphor and digital image correlation (TP + DIC) for simultaneous temperature and strain measurements

We report thermographic phosphors (TP) are combined with stereo digital image correlation (DIC) in a novel diagnostic, TP + DIC, to measure full-field surface strains and temperatures simultaneously. The TP + DIC method is presented, including corrections for nonlinear CMOS camera detectors and generation of pixel-wise calibration curves to relate the known temperature to the ratio of pixel intensities between two distinct wavelength bands. Additionally, DIC is employed not only for strain measurements but also for accurate image registration between the two cameras for the two-colour ratio method approach of phosphoric thermography. TP + DIC is applied to characterize the thermo-mechanical response of 304L stainless steel dog bones during tensile testing at different strain rates. The dog bones are patterned for DIC with Mg 3 F 2 GeO 4 :Mn (MFG) via aerosol deposition through a shadow mask. Temperatures up to 425°K (150°C) and strains up to 1.0 mm/mm are measured in the localized necking region, with conservative noise levels of 10°K and 0.01 mm/mm or less. Finally, TP + DIC is compared to the more established method of combining infrared (IR) thermography with DIC (IR + DIC), with results agreeing favourably. Three topics of continued research are identified, including cracking of the aerosol-deposited phosphor DIC features, incomplete illumination for pixels on the border of the phosphor features, and phosphor emission evolution as a function of applied substrate strain. This work demonstrates the combination of phosphor thermography and DIC and lays the foundation for further development of TP + DIC for testing in combined thermo-mechancial environments.

304L stainless steel↗

Lightcurves, Rotation Periods, and Colors for Vera C. Rubin Observatory’s First Asteroid Discoveries

We present lightcurves, rotation periods, and colors for the first asteroid discoveries made with the NSF-DOE Vera C. Rubin Observatory. These are the first science results derived from the 2103 asteroid discoveries released as part of the Rubin First Look (RFL) media event on 2025 June 23, in which the first LSST Camera commissioning images were released. The ∼340,000 observations in which the discoveries were made span nine nights between 2025 April 21 and May 5. With a limiting single-epoch 5σ depth of ∼23–25 mag and dense temporal sampling under an irregular, commissioning-driven cadence, the RFL observations provide an ideal test bed for determination of rotation periods, including sensitivity to rapid rotation. We model lightcurves and derive rotation periods and colors for the ∼2000 objects. We find 75 main-belt asteroids (MBAs) and one near-Earth object (NEO) with reliable rotation periods spanning 0.031–21.3 hr and a photometric precision in the range of 0.05–0.15 mag. We find 19 superfast rotators with periods shorter than the 2.2 hr spin barrier. Rubin-discovered MBA 2025 MN 45 is the fastest-rotating d > 0.5 km known asteroid with a rotation period of 1.9 minutes; along with NEO 2025 MJ 71 (1.9 minutes) and Rubin-discovered MBAs 2025 MK 41 (3.8 minutes), 2025 MV 71 (13 minutes), and 2025 MG 56 (16 minutes), these five super- to ultrafast rotators join a couple of NEOs as the fastest-spinning subkilometer asteroids known. As this study demonstrates, even in early commissioning, Rubin is successfully probing a previously sparsely sampled region of the subkilometer size−spin rate regime for MBAs.

Greenstreet, Sarah [NSF National Optical-Infrared ↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle balance of deuterium during deuterium shattered pellet injection shutdown in DIII-D

A particle balance analysis was conducted during a deuterium (D 2 ) shattered pellet injection-induced plasma shutdown on the DIII-D tokamak to determine why less than 20% of the pellet material is assimilated into the core plasma by the mid-current quench (CQ). Initially, most of the D 2 is injected as frozen shards and ionized upon entering the vessel. During the thermal quench, ionized particles move to the divertors and subsequently to the center post (CP) walls, where they rapidly recycle and partially accumulate as neutrals without assimilating into the core plasma. In contrast, the particle flux to the outer midplane walls is negligible, despite being accompanied by hot plasma with electron temperatures exceeding 100 eV. During mid-CQ, volume recombination effects, although not large enough to impact overall particle balance, were significant enough to require accounting for accurate interpretation of fast-framing camera D-alpha signals and the estimation of the CP wall particle flux. In addition, toroidal asymmetries, observed in measurements of toroidal electron density perturbations and the phase of magnetohydrodynamic modes, are present throughout the shutdown and can account for a discrepancy in the assimilation rate for up to 50% of the observed D 2 particle inventory. These sources and sinks of particles and fluxes were identified using absolutely calibrated D-alpha brightness and Langmuir probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗