Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Report on the Assessment of Ion Irradiations on High Entropy Alloys

Idaho National Laboratory (INL) initiated a joint international effort with the Czech Republic to explore the feasibility of manufacturing High Entropy Alloys for high-temperature nuclear applications using Additive Manufacturing. This effort was funded at INL by the United States Department of Energy’s Office of Nuclear Energy under the Advanced Reactor Technologies and Advanced Materials and Manufacturing Technologies (AMMT) Program. The High Entropy Alloys were specifically designed for the corrosive and irradiation environments as experienced in gas fast reactors, molten salt reactors, and fusion power. These alloys were manufactured by multiple processes to determine the impact of manufacturing processes on the performance of the alloys in corrosive and irradiation environments. Preliminary results show that MoNbTiV and MoNbTi alloys exhibit no degradation after multiple corrosion tests. These MoNbTiV and MoNbTi alloys were also evaluated after irradiation experiments were conducted at the Michigan Ion Beam Laboratory at the University of Michigan, which is the focus of this milestone report. For these irradiation experiments, the MoNbTiV and MoNbTi alloys manufactured by arc melting and Electric Field Assisted Sintering (EFAS) were tested at 500 C at a dose of 30 dpa to evaluate the microstructural stability and decomposition.

36 - MATERIALS SCIENCE↗

Flavor, transverse momentum, and azimuthal dependence of charged pion multiplicities in semi-inclusive deep-inelastic scattering with 10.6 GeV electrons

Measurements of semi-inclusive deep-inelastic scattering multiplicities for 𝜋 + and 𝜋 − from proton and deuteron targets are reported on a grid of hadron kinematic variables 𝑧, 𝑃 𝑇 , and 𝜙* for leptonic kinematic variables in the range 0.3<𝑥<0.6 and 3<𝑄 2 <5GeV 2 . Data were acquired in 2018 and 2019 at Jefferson Lab Hall C with a 10.6 GeV electron beam impinging on 10-cm-long liquid hydrogen and deuterium targets. Scattered electrons and charged pions were detected in the High Momentum Spectrometer and Super High Momentum Spectrometer, respectively. The multiplicities were fitted for each bin in (𝑥,𝑄 2 ,𝑧,𝑃𝑡) to extract the 𝜙*—independent 𝑀 0 and the azimuthal modulations ⟨cos⁡(𝜙*)⟩ and ⟨cos⁡(2⁢𝜙*)⟩. The 𝑃𝑡 dependence of the 𝑀 0 results was found to be remarkably consistent for the four cases studied: 𝑒⁢𝑝→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑝→𝑒⁢𝜋 − ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 + ⁢𝑋, 𝑒⁢𝑑→𝑒⁢𝜋 − ⁢𝑋 over the range 0GeV<𝑃 𝑡 <0.4GeV, as were the multiplicities evaluated near 𝜙*=180∘ over the extended range 0GeV<𝑃 𝑡 <0.7GeV. The Gaussian widths of the 𝑃 𝑡 dependence exhibit a quadratic increase with 𝑧. The cos⁡(𝜙*) modulations were found to be consistent with zero for 𝜋 + , in agreement with previous world data, while the 𝜋 − moments were, in many cases, significantly greater than zero. The cos⁡(2⁢𝜙*) modulations were found to be consistent with zero. The higher statistical precision of this dataset of about 20 000 individual multiplicity values, compared with previously published data, should allow improved determinations of quark transverse momentum distributions and higher twist contributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Timing reconstruction utilising multiple detection subsystems at the Short-Baseline Near Detector experiment

The Short-Baseline Near Detector (SBND) is the near detector of the Short-Baseline Neutrino Program, located only 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). SBND employs key detection technologies: a 112-ton Liquid Argon Time Projection Chamber for ionisation electrons, an advanced Photon Detection System (PDS) made up of photomultiplier tubes and X-ARAPUCAs for scintillation light, and a 4π coverage of Cosmic Ray Taggers (CRTs) for cosmic muons. This setup offers an exceptional energy, spatial and timing reconstruction of neutrino interactions. In this poster, we present ongoing timing reconstruction efforts of the PDS and CRTs, as well as combining complementary information across multiple detection subsystems to improve the timing resolution. This results in nanosecond level timing information that can be leveraged as an analysis tool, including the reconstruction of the BNB substructure to accept or reject signals detected in-between neutrino bunches as well as a timing-based discrimination for cosmic rejection.

Corallo, Annalea [INFN, Ferrara]↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transmission Electron Microscopy based Characterization of a U-20Pu-10Zr Fuel Irradiated in Experimental Breeder Reactor-II

U-Pu-Zr metallic fuels are important fuel candidate for future advanced and/or test reactors. To better understand fuel performance and guide future fuel development, a U-20Pu-10Zr (in weight) metallic fuel irradiated in the Experimental Breeder Reactor was revisited using advanced electron microscopies. This fuel was irradiated to a burnup of 7.6 % at a peak cladding temperature of 521 °C. In this research, several transmission electron microscopy samples were extracted from different but representative radial locations of the fuel cross section using focused ion beam technique. Phase identification and chemical analysis with sub-micron spatial resolution was carried out using scanning transmission electron microscopy. Multiple phenomena that are critical to fuel performance, such as Zr phase and its distribution in a different matrix, were revealed in an unpreceded and highly detailed manner. An improved understanding of fuel reconstruction in U-Pu-Zr metallic fuel under reactor irradiation is provided.

36 MATERIALS SCIENCE↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Femtosecond multimodal imaging with a laser-driven X-ray source

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

43 PARTICLE ACCELERATORS↗

High-n Rydberg transition spectroscopy for heavy impurity transport studies in W7-X (invited)

Here, we present a novel spectroscopy approach to investigate impurity transport by analyzing line-radiation following high-n Rydberg transitions. While high-n Rydberg states of impurity ions are unlikely to be populated via impact excitation, they can be accessed by charge exchange (CX) reactions along the neutral beams in high-temperature plasmas. Hence, localized radiation of highly ionized impurities, free of passive contributions, can be observed at multiple wavelengths in the visible range. For the analysis and modeling of the observed Rydberg transitions, a technique for calculating effective emission coefficients is presented that can well reproduce the energy dependence seen in datasets available on the OPEN-ADAS database. By using the rate coefficients and comparing modeling results with the new high-n Rydberg CX measurements, impurity transport coefficients are determined with well-documented 2σ confidence intervals for the first time. This demonstrates that high-n Rydberg spectroscopy provides important constraints on the determination of impurity transport coefficients. By additionally considering Bolometer measurements, which provide constraints on the overall impurity emissivity and, therefore, impurity densities, error bars can be reduced even further.

Instruments & Instrumentation↗

Using AI to predict calibration constants for the central drift chamber in GlueX at Jefferson Lab

The AI for Experimental Controls project team at Jefferson Lab has developed an AI system to control and calibrate a large drift chamber system in near-real time. The AI system will monitor environmental and experimental variables to recommend voltage settings that maintain consistent dE/dx gain and optimal resolution throughout the experiment. At present, calibrations are performed after data have been recorded and require a considerable amount of time and attention from experts. The calibrations currently require multiple iterations and depend on accurate tracking information. Our approach uses environmental data, such as atmospheric pressure and gas temperature, and beam conditions, such as the flux of incident particles, as inputs to a Gaussian Process Regression (GPR) model. For the data taken during the GlueX 2020 run period, the GPR is able to predict the existing gain correction factors to within 3.5%. This talk will briefly describe the development, testing, and future plans for this system at Jefferson Lab.

Jeske, Torri↗

Upper Limit for the 248 Cm( 50 Ti, x n) 298− x Og Reaction Cross Section

After the synthesis of element 113, nihonium (Nh) via the 209 Bi( 70 Zn,n) 278 Nh cold fusion reaction using the RIKEN heavy-ion Linear ACcelerator (RILAC) and the GAs-filled Recoil Ion Separator (GARIS), the search for the heaviest isotopes of oganesson was initiated with GARIS-II by means of the 248 Cm( 50 Ti,xn) 298−x Og fusion evaporation reaction. The optimal bombarding energy for the 50 Ti + 248 Cm reaction was determined from the quasielastic barrier distribution extracted from the excitation function of quasielastic backscattering. Here, this method optimizes the compound nucleus formation. The search for Og was conducted for 39 days on the basis of the experimentally derived 50 Ti beam energy of 227.9(5) MeV at the middle of 248 Cm target. A precise analysis of the dataset based on multiple event search strategies revealed no decay chains with a total dose on 248 Cm target of 4.93 × 10 18 50 Ti projectiles, reaching a sensitivity of 0.27 pb and a 1σ upper cross section limit of 0.50 pb.

Gall, Benoît Jean-Paul [University of Strasbourg (↗

Neutrino Dipole Moments and Radiative Signatures from Partial Compositeness

We investigate composite neutrino models where heavy neutrinos emerge as bound states from a near-conformal strongly coupled sector. Standard Model neutrinos mix with these composite singlets via an inverse seesaw mechanism, where the anomalous scaling dimensions of the composite-sector operators naturally suppress light neutrino masses to sub-eV scales. Matching the conformal dynamics onto low-energy theory yields enhanced electromagnetic transition dipole operators with couplings $d_{μN} \sim 10^{-6}$-$10^{-8}\,\mathrm{GeV}^{-1}$, parametrically larger than the loop-level predictions of minimal Dirac or Majorana models. We carry out a dedicated event-level simulation of the production-and-decay chain $νX \to \mathcal{U} X \to νγX$ and compute the resulting event rates at MiniBooNE and MINERvA within the model, accounting for the composite production cross section and decay kinematics in detail. We further present predictions for the photon energy, angular, and multiplicity distributions. For the benchmark scenarios accessible at these experiments the radiative signal is predominantly single-photon; the composite structure additionally permits fragmentation of the up-scattered state into multiple heavy neutrinos, each decaying as $N\toνγ$, with multi-photon final states emerging for lighter compositeness scales or higher beam energies as a qualitatively new probe of the composite dynamics.

Assi, Benoît [Cincinnati U.; Fermilab] (ORCID:0000↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Resistive Wall Simulations for the DARHT Multi-Pulse Test Line

The multi-pulse test line (MPTL) presently under T development at the Dual Axis Radiography Hydrodynamic Test (DARHT) facility may have several meters of drifting beam transport without external magnetic focusing field. The absence of external magnetic focusing is the worst case for growth of the resistive-wall instability. This instability is usually considered to be strictly a long-pulse (low-frequency) problem, but has been theoretically shown to couple the multiple pulses in a long pulse train, such as are expected to be the subject of experimentation on the MPTL. In this note, we explore the resistive wall instability in the MPTL parameter range using our LAMDA beam dynamics code. (LAMDA stands for Linear Accelerator Model for DARHT)

43 PARTICLE ACCELERATORS↗

FULL RANGE TUNE SCAN STUDIES USING GRAPHICS PROCESSING UNITS WITH CUDA IN EIC BEAM-BEAM SIMULATIONS

The hadron beam in the Electron-Ion Collider (EIC) suffers high order betatron and synchro-betatron resonances. In this paper, we present a weak-strong full range (0.0 ~ 0.5) fractional tune scan with a step size as small as 0.001. Multiple Graphics Processing Units (GPUs) are used to speed up the simulation. A code parallelized with MPI and CUDA is implemented. The good tune region from weak-strong scan is further checked by the self-consistent strong-strong simulation. This study provides beam dynamics guidance in choosing proper working points for the future EIC.

43 PARTICLE ACCELERATORS↗

Failure analysis of field-failed bypass diodes

Defective bypass diodes are often found as the largest factor leading to power loss in solar modules. Here, we report on failure mechanisms by investigating shunted bypass diodes from a rooftop installation, using a combination of multiple characterizations including current–voltage analysis, thermal-runaway testing, X-ray computed tomography, lock-in thermography, focused ion-beam cross-section imaging, chemical decapsulation, optical microscopy, and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Differing from static discharge typically associated with lightning strikes on modules, we found diode failure by the mechanism of thermal damage under continuous, long-term overstress in forward bias. Our conclusion is based on evidence of energy dissipated—the small to medium extent of melt-through on the Schottky diode face. The diode failure shows distortions or roughening of the Schottky diode metal-semiconductor interface with the die attach, and some failures are accompanied by die-attach solder melting. We propose that nonuniform irradiance on the modules caused diode shunting due to extended periods of heat dissipation in the modules, because modules in this string were placed in two different orientations. In contrast, a second parallel module string of the same module type on the same rooftop with a unique plane of array did not show any diode failures. The thermal damage failure of melt-through was caused by the long-term current generated by overstressing of diodes that may have had crystalline and impurity defects.

14 SOLAR ENERGY↗