Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “misalignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Auto calibration of a cone-beam-CT

Purpose: This paper introduces a novel autocalibration method for cone-beam-CTs (CBCT) or flat-panel CTs, assuming a perfect rotation. The method is based on ellipse-fitting. Autocalibration refers to accurate recovery of the geometric alignment of a CBCT device from projection images alone, without any manual measurements. Methods: The authors use test objects containing small arbitrarily positioned radio-opaque markers. No information regarding the relative positions of the markers is used. In practice, the authors use three to eight metal ball bearings (diameter of 1 mm), e.g., positioned roughly in a vertical line such that their projection image curves on the detector preferably form large ellipses over the circular orbit. From this ellipse-to-curve mapping and also from its inversion the authors derive an explicit formula. Nonlinear optimization based on this mapping enables them to determine the six relevant parameters of the system up to the device rotation angle, which is sufficient to define the geometry of a CBCT-machine assuming a perfect rotational movement. These parameters also include out-of-plane rotations. The authors evaluate their method by simulation based on data used in two similar approaches [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004); K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)]. This allows a direct comparison of accuracy. Furthermore, the authors present real-world 3D reconstructions of a dry human spine segment and an electronic device. The reconstructions were computed from projections taken with a commercial dental CBCT device having two different focus-to-detector distances that were both calibrated with their method. The authors compare their reconstruction with a reconstruction computed by the manufacturer of the CBCT device to demonstrate the achievable spatial resolution of their calibration procedure. Results: Compared to the results published in the most closely related work [K. Yang, A. L. C. Kwan, D. F. Miller, and J. M. Boone, 'A geometric calibration method for cone beam CT systems,' Med. Phys. 33(6), 1695-1706 (2006)], the simulation proved the greater accuracy of their method, as well as a lower standard deviation of roughly 1 order of magnitude. When compared to another similar approach [L. Smekal, M. Kachelriess, S. E, and K. Wa, 'Geometric misalignment and calibration in cone-beam tomography,' Med. Phys. 31(12), 3242-3266 (2004)], their results were roughly of the same order of accuracy. Their analysis revealed that the method is capable of sufficiently calibrating out-of-plane angles in cases of larger cone angles when neglecting these angles negatively affects the reconstruction. Fine details in the 3D reconstruction of the spine segment and an electronic device indicate a high geometric calibration accuracy and the capability to produce state-of-the-art reconstructions. Conclusions: The method introduced here makes no requirements on the accuracy of the test object. In contrast to many previous autocalibration methods their approach also includes out-of-plane rotations of the detector. Although assuming a perfect rotation, the method seems to be sufficiently accurate for a commercial CBCT scanner. For devices which require higher dimensional geometry models, the method could be used as a initial calibration procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prostatome: A combined anatomical and disease based MRI atlas of the prostate

Purpose: In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. Statistical imaging atlases allow for the integration of information across multiple scales and imaging modalities into a single canonical representation, in turn enabling a fused anatomical-disease representation which may facilitate the characterization of disease appearance relative to anatomic structures. While statistical atlases have been extensively developed and studied for the brain, approaches that have attempted to combine pathology and imaging data for study of prostate pathology are not extant. This works seeks to address this gap. Methods: The AnCoR framework optimizes a scoring function composed of two surface (prostate and central gland) misalignment measures and one intensity-based similarity term. This ensures the correct mapping of anatomic regions into the atlas, even when regional MRI intensities are inconsistent or highly variable between subjects. The framework allows for creation of an anatomic imaging and a disease atlas, while enabling their fusion into the anatomic imaging-disease atlas. The atlas presented here was constructed using 83 subjects with biopsy confirmed cancer who had pre-operative MRI (collected at two institutions) followed by radical prostatectomy. The imaging atlas results from mapping thein vivo MRI into the canonical space, while the anatomic regions serve as domain constraints. Elastic co-registration MRI and corresponding ex vivo histology provides “ground truth” mapping of cancer extent on in vivo imaging for 23 subjects. Results: AnCoR was evaluated relative to alternative construction strategies that use either MRI intensities or the prostate surface alone for registration. The AnCoR framework yielded a central gland Dice similarity coefficient (DSC) of 90%, and prostate DSC of 88%, while the misalignment of the urethra and verumontanum was found to be 3.45 mm, and 4.73 mm, respectively, which were measured to be significantly smaller compared to the alternative strategies. As might have been anticipated from our limited cohort of biopsy confirmed cancers, the disease atlas showed that most of the tumor extent was limited to the peripheral zone. Moreover, central gland tumors were typically larger in size, possibly because they are only discernible at a much later stage. Conclusions: The authors presented the AnCoR framework to explicitly model anatomic constraints for the construction of a fused anatomic imaging-disease atlas. The framework was applied to constructing a preliminary version of an anatomic-disease atlas of the prostate, the prostatome. The prostatome could facilitate the quantitative characterization of gland morphology and imaging features of prostate cancer. These techniques, may be applied on a large sample size data set to create a fully developed prostatome that could serve as a spatial prior for targeted biopsies by urologists. Additionally, the AnCoR framework could allow for incorporation of complementary imaging and molecular data, thereby enabling their careful correlation for population based radio-omics studies.

60 APPLIED LIFE SCIENCES↗

SU-E-J-221: Advantages of a New Surface Imaging Calibration Method for SRS Treatments

Purpose: The present calibration method used for the AlignRT surface imaging system relies on the placement of a calibration plate at the linac isocenter using isocenter surrogates (crosshairs, room lasers, etc.). This work investigated the potential advantages of a new calibration method that shifts the AlignRT isocenter to be coincident with the linac MV beam isocenter. Methods: To quantify the potential uncertainties associated with the present calibration method for SRS treatments, the calibration plate was intentionally shifted away from isocenter +/−3mm in the longitudinal and lateral directions and +/−1mm in the longitudinal, lateral, and vertical directions. A head phantom was placed in a mock SRS treatment position and monitored with the AlignRT system. The AlignRT-indicated offsets were recorded at 270, 315, 0, 45, and 90° couch angles for each intentional calibration misalignment. The new isocenter calibration was applied after each misalignment, and the measurements were repeated and compared to the previous results. Results: With intentional longitudinal and lateral shifts of +/−3mm and +/−1mm in the calibration plate, the average indicated offsets at couch rotations of +/−90° were 4.3mm and 1.6mm, respectively. This was in agreement with the theoretical offset of sqrt(2)*(intentional shift of the calibration plate). Since vertical shifts were along the rotation axis of the couch, these shifts had little effect on the offsets with changing couch angle. When the new calibration was applied, the indicated offsets were all within 0.5mm for all couch angles. These offsets were in agreement with the known magnitude of couch walkout. Conclusion: The potential pitfalls of the present calibration method have been established, and the advantages of the new calibration method have been demonstrated. This new calibration method effectively removes the potential miscalibration artifacts of the present calibration method, giving the AlignRT user more confidence in the system's indicated shifts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing nonrigid registration techniques for motion corrected MR prostate diffusion imaging

Purpose: T{sub 2}-weighted magnetic resonance imaging (MRI) is commonly used for anatomical visualization in the pelvis area, such as the prostate, with high soft-tissue contrast. MRI can also provide functional information such as diffusion-weighted imaging (DWI) which depicts the molecular diffusion processes in biological tissues. The combination of anatomical and functional imaging techniques is widely used in oncology, e.g., for prostate cancer diagnosis and staging. However, acquisition-specific distortions as well as physiological motion lead to misalignments between T{sub 2} and DWI and consequently to a reduced diagnostic value. Image registration algorithms are commonly employed to correct for such misalignment. Methods: The authors compare the performance of five state-of-the-art nonrigid image registration techniques for accurate image fusion of DWI with T{sub 2}. Results: Image data of 20 prostate patients with cancerous lesions or cysts were acquired. All registration algorithms were validated using intensity-based as well as landmark-based techniques. Conclusions: The authors’ results show that the “fast elastic image registration” provides most accurate results with a target registration error of 1.07 ± 0.41 mm at minimum execution times of 11 ± 1 s.

60 APPLIED LIFE SCIENCES↗

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (−15.50 ± 5.59)% to (−2.12 ± 1.05)% and (−7.28 ± 2.30)% to (−0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.

60 APPLIED LIFE SCIENCES↗

The Nature of the Nonsingularity of Inner Interfaces in Hydroxyapatite Ceramics

The morphology of inner interfaces in hydroxyapatite (HA) based calcium phosphate ceramics has been studied by transmission electron microscopy. Grain boundaries in the ceramics have been shown to have a vicinal character, which is related to the mechanism of secondary recrystallization in the material: layer growth of grains via sequential motion of elementary steps on planes corresponding to the {11̄00} HA prism faces, which grow through transitions of atoms from adjacent grains that are in contact through their planes with large Miller indices. The recrystallization process may be accompanied by a “collision” of vicinal growth surfaces of grains with relatively large misalignment angles and the formation of grain boundaries nanofaceted by prism planes of adjacent grains. The recrystallization process in such a case should be expected to continue in the grain with a smaller nonsingularity of the growth front. Grain boundaries may allow for a match between planes differing in Miller indices, nd{sub h1k1l1} ≈ md{sub h2k2l2}, and the formation of grain-boundary Pumphrey dislocations, which compensate for the size mismatch between interplanar spacings and/or misalignment of the planes. The observed characteristic grain match configurations are typical of both ceramics produced by sintering HA powders and HA films produced by ion sputtering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elastic Bayesian Model Calibration

Functional data are ubiquitous in scientific modeling. For instance, quantities of interest are modeled as functions of time, space, energy, density, etc. Uncertainty quantification methods for computer models with functional response have resulted in tools for emulation, sensitivity analysis, and calibration that are widely used. However, many of these tools do not perform well when the computer model’s parameters control both the amplitude variation of the functional output and its alignment (or phase variation). This paper introduces a framework for Bayesian model calibration when the model responses are misaligned functional data. The approach generates two types of data out of the misaligned functional responses: (1) aligned functions so that the amplitude variation is isolated and (2) warping functions that isolate the phase variation. These two types of data are created for the computer simulation data (both of which may be emulated) and the experimental data. The calibration approach uses both types so that it seeks to match both the amplitude and phase of the experimental data. The framework is careful to respect constraints that arise, especially when modeling phase variation, and is framed in a way that it can be done with readily available calibration software. In conclusion, we demonstrate the techniques on two simulated data examples and on two dynamic material science problems: a strength model calibration using flyer plate experiments and an equation of state model calibration using experiments performed on the Sandia National Laboratories’ Z-machine.

97 MATHEMATICS AND COMPUTING↗

Gear-SCouP

Gear-SCouP is an analytical model for the rating analysis of articulated spline coupling designs. Articulated splines are commonly used in the planetary stage of wind turbine gearboxes as the means of transmitting the driving torque while also improving load sharing. Direct measurement of spline loads and performance is extremely challenging because of limited accessibility and spline design standards are limited. For a given torque and shaft misalignment, Gear-SCouP quickly yields physical insights into relationships between the spline design parameters and resulting loads, bending, contact, and shear stresses, and safety factors considering various heat treatment methods. Results of this analytical model are compared well against several computational approaches under moderate misalignment. The computational time of Gear-SCouP is significantly less than other FE-based tools.

Guo, Yi↗

On the Influence of Swell Propagation Angle on Surface Drag

Abstract A combination of turbulence-resolving large-eddy simulations and observations are used to examine the influence of swell amplitude and swell propagation angle on surface drag. Based on the analysis a new surface roughness parameterization with nonequilibrium wave effects is proposed. The surface roughness accounts for swell amplitude and wavelength and its relative motion with respect to the mean wind direction. The proposed parameterization is tested in uncoupled three-dimensional Weather and Research Forecasting (WRF) simulations at grid sizes near 1 km where we explore potential implications of our modifications for two-way coupled atmosphere–wave models. Wind–wave misalignment likely explains the large scatter in observed nondimensional surface roughness under swell-dominated conditions. Andreas et al.’s relationship between friction velocity and the 10-m wind speed under predicts the increased drag produced by misaligned winds and waves. Incorporating wave-state (speed and direction) influences in parameterizations improves predictive skill. In a broad sense, these results suggest that one needs information on winds and wave state to upscale buoy measurements.

54 ENVIRONMENTAL SCIENCES↗

Temporal prepulse contrast degradation in high-intensity CPA lasers from anisotropy of amplifier gain media

Here, we present a study of the temporal pre-pulse contrast degradation of high focused intensity pulses produced in CPA laser systems due to imperfections in amplifier design, alignment of amplifier components, and crystal inhomogeneity. Using an extended cross-polarized imaging technique, we demonstrate the presence of multiple crystal domains inside Ti:sapphire slabs with ≈10 cm diameter. Furthermore, the results of our numerical calculations show that crystalline c-axis orientation inhomogeneity caused by these crystal domains can lead to generation of pre-pulses with relative contrast >10 -10 within several picoseconds before the main pulse. In a multiple-slab amplifier head configuration sometimes used in high repetition rate systems, the misalignment of the amplifier slabs crystalline c-axes with respect to each other can lead to the generation of pre-pulses with relative contrast as high as 10 -6 , depending on the magnitude of misalignment.

47 OTHER INSTRUMENTATION↗

Optical depth measurements by shadow-band radiometers and their uncertainties

Shadow-band radiometers in general, and especially the Multi-Filter Rotating Shadow-band Radiometer (MFRSR), are widely used for atmospheric optical depth measurements. The major programs running MFRSR networks in the U.S. include DOE Atmospheric Radiation Measurement (ARM) Program, USDA UV-B Monitoring and Research Program, NOAA Surface Radiation (SURFRAD) Network, and NASA Solar Irradiance Research Network (SIRN). In this paper we discuss a number of technical issues specific for shadow-band radiometers and their impact on the optical depth measurements. These problems include instrument tilt and misalignment, as well as some data processing artifacts. Techniques for data evaluation and automatic detection of some of these problems are described.

47 OTHER INSTRUMENTATION↗

On-Shot Focal-Spot Characterization Technique Using Phase Retrieval

We present an on-shot focal-spot characterization technique based on a phase-retrieval scheme that retrieves near-field phase from multiplane focal-spot measurements in an experimental target chamber. The technique is easy to implement inside a target chamber and is demonstrated in a multiterawatt laser system. It is also found that phase retrieval can quantitatively detect residual angular dispersion coming from the pulse compressor misalignment.

Bahk, S -W↗

Interferometric null test of a deep parabolic reflector generating a Hertzian dipole field

We report on interferometric characterization of a deep parabolic mirror with a depth of more than five times its focal length. The interferometer is of Fizeau type; its core consists of the mirror itself, a spherical null element, and a reference flat. Because of the extreme solid angle produced by the paraboloid, the alignment of the setup appears to be very critical and needs auxiliary systems for control. Aberrations caused by misalignments are removed via fitting of suitable functionals provided by means of ray tracing simulations. It turns out that the usual misalignment approximations fail under these extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of micron-scale manufacturing flaws on the tensile response of centimeter sized two-photon polymerization microlattices

Two-photon polymerization (TPP) is a unique fabrication technique that enables sub-micron scale resolution. Herein, we report on uniaxial tensile tests on millimeter-sized TPP log-pile structures that were fabricated using a recently developed interdigitated stitching strategy. As expected, the Young’s modulus increased with laser intensity, however elastic modulus, ultimate strength and strain-at-failure varied widely, even for nominally identical samples. Post-mortem analysis revealed a series of print defects resulting from various sources including misalignments, resin shrinkage, laser beam shadowing, and local depletion of the oxygen inhibitor. While some of the defects can be eliminated, such as misalignments due to insufficient precision of the mechanical stage, others are more intrinsic to TPP and thus more difficult to address.

36 MATERIALS SCIENCE↗

Regal Beloit Final Technical Report

The original project proposal submitted from NovaTorque Inc (NovaTorque) in 2016 was to improve the existing motor with 95% efficiency by reducing the losses by 21% to achieve 96%. A few months after the proposal was submitted, NovaTorque lost funding and went out of business. The assets of NovaTorque were then acquired by Regal Beloit Corporation (“Regal Beloit” or “Regal”). When the NovaTorque proposal was selected, the project was transferred to Regal Beloit. Once we had production samples from the new Regal production line, they were tested at the Regal Beloit test lab in Wausau, WI. The original NovaTorque motor had an efficiency of 95%, but when the technology was transferred to Regal Beloit, there were multiple manufacturing improvements made, even though the basic electromagnetic design did not change. The test results in Wausau showed that the motors made at the Regal Beloit plant had an efficiency of 96%. Since the goal of the project was to reduce the losses by 21%, a new efficiency target of 96.8% became the project objective. In the first budget period, motors were tested to get the baseline performance. We then used FEA modeling with ANSYS Maxwell to model the existing motor to get correlation between the FEA simulations and the actual test results. Once the model was validated, we evaluated some changes that could be made to the stator to reduce the losses and improve efficiency without changing the rotor or stator housing, keeping the modifications easy to implement. The changes were primarily in the area of making the stator axially shorter and adding Soft Magnetic Composite (SMC) tooth tips. In the second budget period, we proceeded to design and build the new stator that was identified above and identified additional improvements in the process that included a stator machining modification and the use of rectangular wire. When we actually built the motor, the choice of rectangular wire turned out to be a problem. The wire was made by squishing round wire to get the rectangular shape, which caused work hardening, making the wire too stiff to make the desired coils. We shifted to annealed square wire which was better, but we still could not maintain the proper coil envelope. The result was that we had reduced cross section area for stator laminations. We also had to have a radial offset resulting in a radial misalignment between the stator and rotor because of the oversized coils. After the motor was completed, it was shipped to Texas A&M University for testing. With the loss of flux from these issues, the measured motor efficiency was only 96.3%. The primary focus of this motor was to make sure our FEA simulation model predicted the measured losses and overall efficiency, this we moved on to the FEA simulation. The FEA simulations of the motor “as built” with misalignments had good correlation with the test results, so the next step was to use that model to optimize the design of the motor for a final build. This time we considered changes to the stator and rotor and also minor changes to the housing diameter. In the third budget period, we did the detailed design and construction of the final prototypes. The final prototypes had a slight increase in the stator diameter to fit in a standard Regal Beloit housing. We shortened the stator and use more layers of wire in the coils. We also increased the cone angle of the rotor and stator from the original 110 degrees to 130 degrees to get some additional efficiency and optimized the stator cross section. The predicted efficiency from the FEA simulations was 96.9%. When completed, the motors were tested. We were a little short of reaching our target efficiency goal of 96.8%. We were only able to get to 96.7% efficiency. While it may be possible with additional iterations in designs and future builds to gain that additional 0.1%, we believe that we are close to the best we can achieve from a practical viewpoint, and additional iterations would be more work than the potential gains would be worth. No other motor in this class can even reach the 96% that we started with.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Focusing Optics for Axion Detection: Simulating Sensing Enhancements of Photons in InfraBREAD

The Broadband Reflector Experiment for Axion Detection (BREAD) will search for axions, a promising particle candidate for dark matter, in the high mass range of [$10^{-3}$,1]eV. BREAD acts like a telescope for dark matter, using a parabolic reflector to direct axion-induced photons onto a precise focal spot. InfraBREAD is the experimental version designed to detect photons resulting from axions with infrared frequency using a 1mm × 1mm Superconducting Nanowire Singe Photon Detector (SNSPD). However, at this frequency scale two problems arise: 1) the focal spot becomes smeared across an area larger than the size of the SNSPD detector; 2) any millimeter-scale misalignment shifts in the SNSPD can greatly diminish photon signal. This study performed simulations of novel optical configurations of lenses and reflectors placed around the SNSPD to achieve a greater efficiency than the SNSPD alone through both of these effects. One optical setup was identified called the “Parabolo id to Winston Cone (PTW) Configuration,” which exploits the optics of parabolic reflectors to focus incoming photons from the larger area of the smeared focal spot onto the smaller 1mm 2 area of the detector. The PTW configuration demonstrated overall improvements in efficiency by around 10% through misalignment shifts, with a maximal improvement of 55% in one region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗