Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Tracer-field cross-correlations with k -nearest neighbour distributions

ABSTRACT In astronomy and cosmology significant effort is devoted to characterizing and understanding spatial cross-correlations between points – e.g galaxy positions, high energy neutrino arrival directions, X-ray and AGN sources, and continuous fields – e.g. weak lensing meiand Cosmic Microwave Background maps. Recently, we introduced the k-nearest neighbour (kNN) formalism to better characterize the clustering of discrete (point) data sets. Here, we extend it to the point – field cross-correlations analysis. It combines kNN measurements of the point data set with measurements of the field smoothed at many scales. The resulting statistics are sensitive to all orders in the joint clustering of the points and the field. We demonstrate that this approach, unlike the 2-pt cross-correlation, can measure the statistical dependence of two data sets even when there are no linear (Gaussian) correlations between them. We further demonstrate that this framework is far more effective than the two point function in detecting cross-correlations when the continuous field is contaminated by high levels of noise. For a particularly high level of noise, the cross-correlation between haloes and the underlying matter field in a cosmological simulation, between 10 h−1 Mpc and 30 h−1 Mpc, is detected at >5σ significance using the technique presented here, when the two-point cross-correlation significance is ∼1σ. Finally, we show that kNN cross-correlations of haloes and the matter field can be well modelled on quasi-linear scales using the Hybrid Effective Field Theory (HEFT) framework, with the same set of bias parameters as are used for 2-pt cross-correlations. The substantial improvement in the statistical power of detecting cross-correlations using this method makes it a promising tool for various cosmological applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Standard methods for analysis and interpretation of Lidar data for environmental monitoring

Lidar is similar in principle to microwave radar but uses a pulsed laser as the source and an optical telescope as the receiver. Lidar observations of elastic scattering from aerosols and more recently Raman scattering from molecules have been performed in the atmosphere with favorable results. A description of the Lidar technique is provided. Lidar measurements of remote visibility are discussed together with the measurement of remote visibility and the determination of molecular concentrations.

Melfi, S. H.↗

Preliminary assessment of RFI impacts on TDRSS in the 2- to 2.3 GHz band

A study was conducted of the radio frequency bands and radio frequency interference (RFI) impacts on the TDR satellite. Quick look evaluations were performed on RFI conditions in the 136 to 138 MHz and 400.5 to 401.5 MHz bands. An approximate chronological account of the investigations and the intermediate findings are presented. The preliminary results of RFI evaluations in the nominally 2 to 2.3 GHz band. An analysis of the time interaction of user satellites with microwave radio-relay type communications beams as a source of RFI is included.

Lyttle, J. D.↗

A simulation experiment of photochemical reactions in the mesosphere

An ionospheric simulation experiment has been performed in a large vacuum chamber. The chamber is filled with NO and other gases including N2, O2, CO2, NH3 and H2O in the pressure range of 0.01 torr. A lamp which produces photons at 1236- and 1165-A by means of microwave discharge in krypton is utilized as an ionization source. In addition to 30+ large quantities of the water cluster ions 55+, H3O(+).(H2O)2, 73+, H3O(+).(H2O)3 and 91+, H3O(+).(H2O)4 were observed when nitric oxide and water were present. This closely approximates the condition of the terrestrial D region. After long periods of UV irradiation 74+ and 104+ ions grow in intensity. These ions are tentatively identified as NO(+).N2O and NO(+).NO.N2O. In addition the series 18+, 36+, 54+, and 72+ is detected which can be labeled NH4(+), NH4(+).(H2O), NH4(+).(H2O)2 and NH4(+).(H2O)3. These same species of ions are observed with the introduction of ammonia into the chamber. Presumably both N2O and NH3 are products of the photolysis.

Fugono, N.↗

Determination of molecular spectroscopic parameters and energy-transfer rates by double-resonance spectroscopy

The spectroscopy of small to medium-size polyatomic molecules can be extremely complex, especially in higher-lying overtone and combination vibrational levels. The high density of levels also complicates the understanding of inelastic collision processes, which is required to model energy transfer and collision broadening of spectral lines. Both of these problems can be addressed by double-resonance spectroscopy, i.e., time-resolved pump-probe measurements using microwave, infrared, near-infrared, and visible-wavelength sources. Information on excited-state spectroscopy, transition moments, inelastic energy transfer rates and propensity rules, and pressure-broadening parameters may be obtained from such experiments. Examples are given for several species of importance in planetary atmospheres, including ozone, silane, ethane, and ammonia.

Steinfeld, J. I.↗

A Measurement of the Millimeter Emission and the Sunyaev-Zel'dovich Effect Associated with Low-Frequency Radio Sources

We present a statistical analysis of the millimeter-wavelength properties of 1.4 GHz-selected sources and a detection of the Sunyaev-Zel'dovich effect associated with the halos that host them. We stack data at 148, 218 and 277 GHz from the Atacama Cosmology Telescope at the positions of a large sample of radio AGN selected at 1.4 GHz. The thermal Sunyaev-Zel'dovich (SZ) effect associated with the halos that host the AGN is detected at the 5 sigma level through its spectral signature, representing a statistical detection of the SZ effect in some of the lowest mass halos (average M(sub 200) approximately equals 10(sup 13) solar mass h(sub 70)(exp −1) ) studied to date. The relation between the SZ effect and mass (based on weak lensing measurements of radio galaxies) is consistent with that measured by Planck for local bright galaxies. In the context of galaxy evolution models, this study confirms that galaxies with radio AGN also typically support hot gaseous halos. Adding Herschel observations allows us to show that the SZ signal is not significantly contaminated by dust emission. Finally, we analyze the contribution of radio sources to the angular power spectrum of the cosmic microwave background.

radio continuum↗

VLA observations of impulsive solar flares at 4.9 GHz

A series of snapshot synthesis maps constructed as a function of time provided a complete mapping of source structure in one dimension and absolute location in two dimensions of five impulsive solar microwave bursts observed during July 15-18, 1978. It was found that all five flares were dominated by a single 12-18 arcsec source located between the H-alpha kernels, near the magnetic neutral line. Spectral data from Sagamore Hill (1.4-35 GHz) show that the spectral turnover at low frequencies results from the absorption by the ambient active region; these results, together with the observed magnetic configuration, suggest a model which could explain the evolution in source structure at 4.9 GHz in terms of magnetic reconnection which starts below the optical depth of the ambient active region equal to 1.

Marsh, K. A.↗

The microwave and far-infrared spectra of the SiH radical

Consideration of Si's cosmic abundance leads to the expectation that the related molecule SiH may be detected in extraterrestrial sources. A tabulation is presented of frequencies, wavelengths, and line strengths for SiH molecule transitions at microwave and far-IR wavelengths, on the basis of an analysis of its laser magnetic resonance spectrum. It is hoped that the frequencies presented will be useful to both laboratory spectroscopists and astrophysicists.

Brown, J. M.↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Assessment of Retrieved GMI Emissivity Over Land, Snow, and Sea Ice in the GEOS System

Directly assimilating microwave radiances over land, snow and sea ice remains a significant challenge for data assimilation systems. These data assimilation systems are critical to the success of global numerical weather prediction systems including the Global Earth Observing System-Atmospheric Data Assimilation System (GEOS-ADAS). Extending more surface sensitive microwave channels over land, snow and ice could provide a needed source of data for Numerical Weather Prediction particularly in the Planetary Boundary Layer (PBL). Unfortunately, the accuracy of emissivity models currently available within the GEOS-ADAS along with other data assimilation systems are insufficient to simulate and assimilate radiances. Recently, Munchak et al. (2020) published a 5-year climatological database for retrieved microwave emissivity from the GPM Microwave Imager (GMI) aboard the Global Precipitation Mission (GPM). In this work the database is utilized by modifying the GEOS-ADAS to use this emissivity database in place of the default emissivity value available in the Community Radiative Transfer Model (CRTM), which is the fast radiative transfer model used by the GEOS-ADAS. As a first step, the GEOS-ADAS is run in a so-called “stand-alone” mode to simulate radiances from GMI using the default CRTM emissivity, and replacing the default CRTM emissivity models with values from Munchak et al, 2020. The simulated observations using Munchak et al., 2020 agree more closely with observations from GMI. These results are presented along with a discussion of the implication for GMI observations within the GEOS-ADAS.

GPM↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Intuitive study on the effect of support morphology over Cs-Ru/CeO 2 catalyst for microwave-initiated ammonia synthesis

Microwave-initiated ammonia synthesis is a potential candidate to the current Haber-Bosch process that can operate from stranded renewable energy source. Our previous studies indicated Cs-Ru/CeO 2 is a promising catalyst for microwave-assisted ammonia synthesis and the morphology of CeO 2 significantly affects the catalytic performance. In this paper, CeO 2 support with distinct morphologies nanorod, nanoparticle, and microstructure, is studied comprehensively at ambient pressure and low temperature under microwave irradiation. Moreover, CeO 2 nanorods of various sizes were synthesized at different timing (24, 36, and 48 h). Nanorods synthesized at 36 h exhibited superior activity associated to high dispersion and small Ru particle size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvements in Speed and Functionality of a 670-GHz Imaging Radar

Significant improvements have been made in the instrument originally described in a prior NASA Tech Briefs article: Improved Speed and Functionality of a 580-GHz Imaging Radar (NPO-45156), Vol. 34, No. 7 (July 2010), p. 51. First, the wideband YIG oscillator has been replaced with a JPL-designed and built phase-locked, low-noise chirp source. Second, further refinements to the data acquisition and signal processing software have been performed by moving critical code sections to C code, and compiling those sections to Windows DLLs, which are then invoked from the main LabVIEW executive. This system is an active, single-pixel scanned imager operating at 670 GHz. The actual chirp signals for the RF and LO chains were generated by a pair of MITEQ 2.5 3.3 GHz chirp sources. Agilent benchtop synthesizers operating at fixed frequencies around 13 GHz were then used to up-convert the chirp sources to 15.5 16.3 GHz. The resulting signals were then multiplied 36 times by a combination of off-the-shelf millimeter- wave components, and JPL-built 200- GHz doublers and 300- and 600-GHz triplers. The power required to drive the submillimeter-wave multipliers was provided by JPL-built W-band amplifiers. The receive and transmit signal paths were combined using a thin, high-resistivity silicon wafer as a beam splitter. While the results at present are encouraging, the system still lacks sufficient speed to be usable for practical applications in a contraband detection. Ideally, an image acquisition speed of ten seconds, or a factor of 30 improvement, is desired. However, the system improvements to date have resulted in a factor of five increase in signal acquisition speed, as well as enhanced signal processing algorithms, permitting clearer imaging of contraband objects hidden underneath clothing. In particular, advances in three distinct areas have enabled these performance enhancements: base source phase noise reduction, chirp rate, and signal processing. Additionally, a second pixel was added, automatically reducing the imaging time by a factor of two. Although adding a second pixel to the system doubles the amount of submillimeter components required, some savings in microwave hardware can be realized by using a common low-noise source.

Dengler, Robert J.↗

Beamline Spectroscopy of Integrated Circuits With Hard X-Ray Transition Edge Sensors at the Advanced Photon Source

At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave-Driven Multifunctional Capability of Membrane Structures

A large, ultra lightweight space structure, such as solar sails and Gossamer spacecrafts, requires a distributed power source to alleviate wire networks, unlike the localized on-board power infrastructures typically found in most small spacecrafts. The concept of microwave-driven multifunctional capability for membrane structures is envisioned as the best option to alleviate the complexity associated with hard-wired control circuitry and on-board power infrastructures. A rectenna array based on a patch configuration for high voltage output was developed to drive membrane actuators, sensors, probes, or other devices. Networked patch rectenna array receives and converts microwave power into a DC power for an array of smart actuators. To use microwave power effectively, the concept of a power allocation and distribution (PAD) circuit is adopted for networking a rectenna/actuator patch array. The use of patch rectennas adds a significant amount of rigidity to membrane flexibility and they are relatively heavy. A dipole rectenna array (DRA) appears to be ideal for thin-film membrane structures, since DRA is flexible and light. Preliminary design and fabrication of PAD circuitry that consists of a few nodal elements were made for laboratory testing. The networked actuators were tested to correlate the network coupling effect, power allocation and distribution, and response time.

Choi, Sang H.↗

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION↗

Multi-wave band SMM-VLA observations of an M2 flare and an associated coronal mass ejection

Results are presented of observations of an M2 flare and an associated coronal mass ejection CME by instruments on the SMM as well as by the VLA and other ground-based observatories on September 30, 1988. The multiwave band data show a gradual slowly changing event which lasted several hours. The microwave burst emission was found to originate in compact moderately circularly polarized sources located near the sites of bright H-alpha and soft X-ray emission. These data are combined with estimates of an electron temperature of 1.5 x 10 to the 7th K and an emission measure of about 2.0 x 10 to the 49th/cu cm obtained from Ca XIX and Fe XXV spectra to show that the microwave emission can be attributed to thermal gyrosynchrotron radiation in regions where the magnetic field strength is 425-650 G. The CME acceleration at low altitudes is measured on the basis of ground- and space-based coronagraphs.

Willson, Robert F.↗