Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Evaluation of an Arrival Coordinator Position in a Terminal Metering Enviornment

NASA has developed an integrated arrival-management solution for terminal area precision scheduling (TAPSS). Ahuman-in-the-loop simulation investigated the performance of the components of the TAPSS system. The focus ofthis paper is set on the terminal radar approach control (TRACON) traffic management controller (TMC) and ArrivalRadar Coordinator (ARC) combined position, which played an integral part in coordinating, adjusting, and instantiatingthe arrival schedule computed by the TAPSS system. Analysis of the simulation data highlights the roleof the ARC within the described terminal metering environment, describes his planning strategies, the interactionswith his tools and coordination with controllers, and lends insights to the impact of the ARCs actions to the arrivalproblem. High levels of comfort and confidence were reported when working with the TAPSS system. Challengesposed the sequencing of unscheduled satellite arrival flights during periods of peak demand. To accommodate thoseflights into the arrival stream, the ARC had to identify sequence slots, while minimizing disruptions to the schedule.

terminal metering↗

Latest Strategic Surface Metering System and Progress Status in CLT

This presentation provides description of the field evaluation of surface metering deployed by NASA in Charlotte International Airport (CLT) that began with a more tactical decision timeline and progressively expanded toward more strategic timelines. This will include an update on the latest status of the ongoing research and lessons learned.

surface metering↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

bayesian structural time series↗

Batteries in SAM 2020.2.29: Behind-the-Meter Systems

Provide an overview of behind the meter dispatch methods in the SAM 2020.2.29 software for analysis of residential, commercial, and generic battery systems. Discuss the details of SAM's automatic peak shaving and manual energy arbitrage dispatch options.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources: Preprint

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfill their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

behind-the-meter↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Laser ablation of high-loading Li-ion battery electrodes improves accessible capacity and cycle life for Behind-the-Meter Storage

Adoption of Behind-the-Meter Storage (BTMS) requires design of batteries that enable high safety, long cycle life, and low cost at the system level. Pairing Li 4 Ti 5 O 12 (LTO) with LiMn 2 O 4 (LMO) achieves targets related to safety and cycle life, but these materials' low energy densities contribute to higher cost at the system scale. Increasing electrode loading is a simple approach to improve energy density, but comes with a trade-off in electrode utilization due to long, tortuous Li + diffusion pathways. Here, laser ablation is used to microstructure (pattern) high-loading electrodes to enhance electrode performance through improved Li + diffusion pathways. Four cell types, comprising combinations of standard or patterned anode and cathode, were prepared to evaluate the effects of laser ablation at each electrode. A rate test shows that patterning electrodes enhances active material utilization at ≳1C rates. Patterning the cathode yields the most benefit, as cells with a patterned cathode demonstrate a ~20% higher accessible capacity than those without at 1.4C. Additionally, 1C capacity retention of cells with patterned cathode (91% through 3000 cycles) is significantly improved over cells with only the anode patterned (64%) and non-patterned electrodes (50%). Characterization of post-mortem cells before and after refreshing their electrolyte suggests that 1C capacity retention is improved by mitigation of electrode "dry-out". We hypothesize that the microstructure acts as a reservoir of additional electrolyte, or a path for gas to escape, so that active material remains wetted throughout long-term cycling, and/or the microstructure may reduce localized, gas-forming overpotentials in the high-loading electrode.

25 ENERGY STORAGE↗

Standoff trace explosives vapor detection at meter distances

Vapor detection is a noncontact sampling method, which is a less invasive means of explosives screening than physical swiping. Explosive vapor detection is a challenge due to the low levels of vapors available for detection. This study demonstrates that the parts-per-quadrillion sensitivity of atmospheric flow tube-mass spectrometry (AFT-MS) combined with a high-volume air sampler enables standoff detection of trace explosives vapor at distances of centimeters to meters. Standoff detection of explosives vapor was possible both upstream and downstream of the vapor source relative to room air currents. RDX vapor from a saturated source was detected at up to 2.5 m. Vapors from RDX residue and nitroglycerin residue were detected at distances up to 0.5 m. The sampling can be optimized by accounting for air movement in the room or environment, which could further extend standoff detection distances. In conclusion, using AFT-MS with a high-volume sampler could also be effective for standoff vapor detection of drugs and additional chemical threats and could be useful for security screening applications such as at mail facilities, border crossings, and security checkpoints.

47 OTHER INSTRUMENTATION↗

Incorporating Diurnal and Meter-Scale Variations of Ambient CO 2 Concentrations in Development of Direct Air Capture Technologies

To be implemented on climate-relevant scales, direct air capture of CO 2 (DAC) will require large capital-intensive facilities and careful attention to cost minimization. In making decisions among potential sites for DAC facilities, all of the factors that will impact process cost and efficiency should be considered. In this paper we focus on a factor that has previously received little attention in the DAC community, namely variations in atmospheric conditions on hourly time scales and length scales of meters. We present data curated from extensive previous studies of biosphere-atmosphere fluxes with observations of CO 2 concentration, temperature, and relative humidity (RH) with hourly resolution from many sites in North America. These include locations where typical diurnal variations in CO 2 concentration during summer months exceeds 150 ppm. These variations are larger than the seasonal variations that exist between averaged CO 2 concentrations in winter and summer, and they are highly correlated with diurnal variations in temperature and RH. Diurnal variations are dependent on the height above ground at which CO 2 concentrations are measured, with smaller variations existing at heights of 10 m or more than at ground level. We illustrate the potential implications of these short-term variations for the operation and optimization of a DAC process with process-level calculations for a specific adsorption-based process using amine-rich adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Seismic Ambient Noise Analyses Reveal Changing Temperature and Water Signals to 10s of Meters Depth in the Critical Zone

The critical zone sustains terrestrial life, but we have few tools to explore it efficiently beyond the first few meters of the subsurface. Using analyses of high-frequency ambient seismic noise from densely spaced seismometers deployed in the forested Shale Hills subcatchment of the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO), we show that temporal changes in seismic velocities at depths from ~1 m to tens of m can be detected. Furthermore, these changes are driven by variations at the land surface. The Moving-Window Cross-Spectral (MWCS) method was employed to measure seismic-velocity changes in coda waves at hourly resolution in 10 different frequency bands. We observed a diurnal signal, a seasonal signal, and a meteorological-event-based signal. These signals were compared to time-series measurements of precipitation, well water levels, soil moisture, soil temperature, air temperature, latent heat flux, and air pressure in the heavily instrumented catchment. Most of the velocity changes can be explained by variations in temperature that result in thermoelastic strains that propagate to depth. But some double minima in seismic velocity time-series observed after large rain events were attributed in part to the effects of water infiltration. These results show that high-frequency ambient noise data may in some locations be used to detect changes in the critical zone from ~1 to ~100 m or greater depth with hourly resolution. But interpretation of such data requires multiple environmental data sets to deconvolve the complex interrelationships among thermoelastic and hydrological effects in the subsurface critical zone.

54 ENVIRONMENTAL SCIENCES↗

Theory of an Automatic Seepage Meter and Ramifications for Applications

A new approach for measuring fluxes across surface water—groundwater interfaces was recently proposed. The Automatic Seepage Meter (ASM) is equipped with a precise water level sensor and digital memory that analyzes water level time series in a vertical tube inserted into a streambed. The ability to infer flux values with high temporal resolution relies on an accurate interpretation of water level dynamics inside the tube. Here, we reduce the three-dimensional hydrodynamic problem that describes the ASM water level in a variety of field conditions to a single ordinary differential equation. This novel general analytical solution for estimating ASM responses is more comprehensive and flexible than previous approaches and is applicable to the entire range of field conditions, including steady or transient stream stages, evaporation, rainfall, and noise. For example, our analysis determines the timing of the nonmonotonic ASM response to a monotonic linear stream stage variation and explains previously used empirical parabolic approximation for estimating fluxes. We present algorithms for simultaneous inference of vertical interface flux and hydraulic conductivity values together with an example code. We quantify how the accuracy of parameter estimation depends on test duration and noise amplitude and propose how our analysis can be used to optimize field test protocols. On this basis, changing the ASM geometry by increasing the radius and decreasing tube insertion depth may enable ASM field test protocols that estimate interface flux and hydraulic conductivity faster while maintaining desired accuracy. Potential applications of joint parameter estimation are suggested.

47 OTHER INSTRUMENTATION↗