Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The Inception of OMA in the Development of Modal Testing Technology for Wind Turbines

Wind turbines are immense, flexible structures with aerodynamic forces acting on the rotating blades at harmonics of the turbine rotational frequency, which are comparable to the modal frequencies of the structure. Predicting and experimentally measuring the modal frequencies of wind turbines has been important to their successful design and operation. Performing modal tests on wind turbine structures over 100 meters tall is a substantial challenge, which has inspired innovative developments in modal test technology. For wind turbines, a further complication is that the modal frequencies are dependent on the turbine rotation speed. The history and development of a new technique for acquiring the modal parameters using output-only response data, called the Natural Excitation Technique (NExT), will be reviewed, showing historical tests and techniques. The initial attempts at output-only modal testing began in the late 1980's with the development of NExT in the 1990's. NExT was a predecessor to OMA, developed to overcome these challenges of testing immense structures excited with environmental inputs. We will trace the difficulties and successes of wind turbine modal testing from 1982 to the present. Keywords: OMA, Modal Analysis, NExT, Wind Turbines, Wind Excitation

James, George H., III↗

Testing the James Webb Space Telescope Primary Mirror

JWST in-process optical testing and cryogenic requirement compliance certification, verification andvalidation was probably the most difficult metrology job of our generation in astronomical optics. But, the challenge was met: by hard work of dozens of optical metrologists; development and qualification of multiple custom test setups; and several new inventions, including 4D PhaseCam and Leica Absolute Distance Meter. This paper summarizes the metrology tools, test setups and processes used to characterize the JWST primary mirror.

Stahl, H. Philip↗

Development and testing of the Shenandoah collector

The test and development of the 7-meter Shenandoah parabolic dish collector incorporating an FEK-244 film reflective surface and cavity receiver are described. Four prototypes tested in the midtemperature Solar System Test Facility indicate, with changes incorporated from these development tests, that the improvements should lead to predicted performance levels in the production collectors.

Kinoshita, G. S.↗

Flow visualization in the Langley 0.3-meter Transonic Cryogenic Tunnel and preliminary plans for the National Transonic Facility

Design problems associated with the integration of flow visualization in cryogenic facilities are discussed. The possible effects from the cryogenic environment (i.e., window distortion due to thermal contraction both in the mounts and in the window material itself and turbulence in the flow due to injected LN2) are examined. The flow visualization techniques studied are schlieren, shadowgraph, moire deflectometry, and holographic interferometry. The test beds for this work are a Langley in-house cryogenic test chamber and the 0.3-Meter Transonic Cryogenic Tunnel.

Rhodes, D. B.↗

Ice Particle Impacts on a Moving Wedge

This work presents the results of an experimental study of ice particle impacts on a moving wedge. The experiment was conducted in the Adverse Environment Rotor Test Stand (AERTS) facility located at Penn State University. The wedge was placed at the tip of a rotating blade. Ice particles shot from a pressure gun intercepted the moving wedge and impacted it at a location along its circular path. The upward velocity of the ice particles varied from 7 to 12 meters per second. Wedge velocities were varied from 0 to 120 meters per second. Wedge angles tested were 0, 30, 45, and 60. High speed imaging combined with backlighting captured the impact allowing observation of the effect of velocity and wedge angle on the impact and the post-impact fragment behavior. It was found that the pressure gun and the rotating wedge could be synchronized to consistently obtain ice particle impacts on the target wedge. It was observed that the number of fragments increase with the normal component of the impact velocity. Particle fragments ejected immediately after impact showed velocities higher than the impact velocity. The results followed the major qualitative features observed by other researchers for hailstone impacts, even though the reduced scale size of the particles used in the present experiment as compared to hailstones was 4:1.

Impacts↗

Ice Particle Impacts on a Moving Wedge

This work presents the results of an experimental study of ice particle impacts on a moving wedge. The experiment was conducted in the Adverse Environment Rotor Test Stand (AERTS) facility located at Penn State University. The wedge was placed at the tip of a rotating blade. Ice particles shot from a pressure gun intercepted the moving wedge and impacted it at a location along its circular path. The upward velocity of the ice particles varied from 7 to 12 meters per second. Wedge velocities were varied from 0 to 120 meters per second. Wedge angles tested were 0 deg, 30 deg, 45 deg, and 60 deg. High speed imaging combined with backlighting captured the impact allowing observation of the effect of velocity and wedge angle on the impact and the post-impact fragment behavior. It was found that the pressure gun and the rotating wedge could be synchronized to consistently obtain ice particle impacts on the target wedge. It was observed that the number of fragments increase with the normal component of the impact velocity. Particle fragments ejected immediately after impact showed velocities higher than the impact velocity. The results followed the major qualitative features observed by other researchers for hailstone impacts, even though the reduced scale size of the particles used in the present experiment as compared to hailstones was 4:1.

Roughness↗

Seeing through flows in Langley's 0.3-meter Transonic Cryogenic Tunnel

Viewing problems associated with the measurement of model deformation in cryogenic wind tunnels are discussed. Tests were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel to assess viewing capabilities thru the flow field. The effects of condensation and turbulent boundary layers are discussed and a modelling procedure for image degradation is described.

Snow, W. L.↗

A Practical Methodology for Quantifying Random and Systematic Components of Unexplained Variance in a Wind Tunnel

This paper documents a check standard wind tunnel test conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3M TCT) that was designed and analyzed using the Modern Design of Experiments (MDOE). The test designed to partition the unexplained variance of typical wind tunnel data samples into two constituent components, one attributable to ordinary random error, and one attributable to systematic error induced by covariate effects. Covariate effects in wind tunnel testing are discussed, with examples. The impact of systematic (non-random) unexplained variance on the statistical independence of sequential measurements is reviewed. The corresponding correlation among experimental errors is discussed, as is the impact of such correlation on experimental results generally. The specific experiment documented herein was organized as a formal test for the presence of unexplained variance in representative samples of wind tunnel data, in order to quantify the frequency with which such systematic error was detected, and its magnitude relative to ordinary random error. Levels of systematic and random error reported here are representative of those quantified in other facilities, as cited in the references.

Deloach, Richard↗

Aerodynamic measurements and thermal tests of a strain-gage balance in a cryogenic wind tunnel

An internal strain-gage balance designed and constructed in Europe for use in cryogenic wind tunnels has been tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel. Part of the evaluation was made at equilibrium balance temperatures and it consisted of comparing the data taken at a tunnel stagnation temperature of 300 K with the data taken at 200 K and 110 K while maintaining either the Reynolds number or the stagnation pressure. A sharp-leading-edge delta-wing model was used to provide the aerodynamic loading for these tests. Results obtained with the balance during the force tests were found to be accurate and repeatable both with and without the use of a convection shield on the balance. An additional part of this investigation involved obtaining data on the transient temperature response of the balance during both normal and rapid changes in the tunnel stagnation temperature. The variation of the temperature with time was measured at three locations on the balance near the physical locations of the strain gages. The use of a convection shield significantly increased the time required for the balance to stabilize at a new temperature during the temperature response tests.

Boyden, Richmond P.↗

Fabrication and Testing of a Large Active Primary Reflector

This paper discusses the fabrication considerations and proposed testing concepts for a twelve meter, graphite-epoxy space truss that is being developed to provide structural support for the primary mirror system of the SpacE Laser ENErgy Beam Transmission Optical System.

primary mirror↗

M&V Tool Testing Portal v1

Software is an online self-service portal for testing M&V methods/tools using buildings' interval meter data. After registering as a user in the portal, that user can download test data files, run those test data files through their own M&V software, and then upload software modeling results to the online portal as a csv file. After the user has uploaded their modeling results the portal will develop statistical accuracy metrics for that M&V tool. The online portal will summarize test results for some or all of the submitted tests. This online portal has been developed by LBNL, and we have been collaborating with the Efficiency Valuation Organization (EVO) with the objective of EVO managing the portal as an ongoing service. Portal is currently posted at http://mvportal.evo-world.org/

Cholia, Shreyas↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

The Mojave Subsurface Bio-Geochemistry Explorer (MOSBE)

The MOSBE Team has developed a terrestrial field campaign to explore two subsurface biological habitats under the Mojave Desert. This field campaign will not only help us understand terrestrial desert biology, but also will develop methodologies and strategies for potential future Mars missions that would seek to explore the Martian subsurface. We have proposed to the ASTEP program to integrate a suite of field demonstrated instruments with a 20 m subsurface drill as a coherent unit, the Mojave Subsurface Bio-geochemistry Explorer. The ATK Space Modular Planetary Drill System (MPDS) requires no drilling fluid, which allows aseptic sampling, can penetrate lithic ground up to 20 meters of depth, and utilizes less than 100 Watts throughout the entire depth. The drill has been developed and demonstrated in field testing to a depth of 10 meters in Arizona, December 2002. In addition to caching a continuous core throughout the drilling depth, it also generates and caches cuttings and fines that are strata-graphically correlated with the core. As a core segment is brought to the surface, it will be analyzed for texture and structure by a color microscopic imager and for relevant chemistry and mineralogy with a UV fluorescence/Raman spectrometer. Organic and soluble ionic species will be identified through two instruments -- a microcapillary electrophoresis, and an ion trap mass spectrometer that have been developed under PIDDP, ASTID and MIDP funding.

robotic subsurface drilling↗

M & V Shootout: Setting the Stage For Testing the Performance of New Energy Baseline

Trustworthy savings calculations are critical to convincing investors in energy efficiency projects of the benefit and cost-effectiveness of such investments and their ability to replace or defer supply-side capital investments. However, today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of efficiency projects. They also require time-consuming data acquisition and often do not deliver results until years after the program period has ended. A spectrum of savings calculation approaches are used, with some relying more heavily on measured data and others relying more heavily on estimated or modeled data, or stipulated information. The rising availability of “smart” meters, combined with new analytical approaches to quantifying savings, has opened the door to conducting M&V more quickly and at lower cost, with comparable or improved accuracy. Energy management and information systems (EMIS) technologies, not only enable significant site energy savings, but are also beginning to offer M&V capabilities. This paper expands recent analyses of public-domain, whole-building M&V methods, focusing on more novel baseline modeling approaches that leverage interval meter data. We detail a testing procedure and metrics to assess the performance of these new approaches using a large test dataset. We also provide conclusions regarding the accuracy, cost, and time trade-offs between more traditional M&V and these emerging streamlined methods. Finally, we discuss the potential evolution of M&V to better support the energy efficiency industry through low-cost approaches, and the long-term agenda for validation of building energy analytics.

Touzani, Samir↗

Adaptive microwave reflector

As an interim step in going to the 100-meter reflector that was evaluated, a 5-meter reflector is proposed to test the electrostatic concept under space conditions. Some of the issues which require the space environment for evaluation are the following questions: Can deployment of a box ring structure with a thin film reflector attached be manually deployed? In the absence of humidity, can a 0.3-mil aluminized Kapton film reflector be formed by the electrostatic process suitable for antenna applications? Can the photogrammetric process be used to evaluate the reflector surface with pictures taken from the payload handling station? Can the space charging effect be evaluated with the 5-meter reflector attached to the Shuttle? Does the outgassing of moisture from 0.3-mil Kapton film affect its reflector capability? A box ring truss support structure and an automatic sequence deployment system are discussed.

Goslee, J. W.↗

Flight tests of Viking parachute system in three Mach number regimes. 2: Parachute test results

Tests of the Viking 16.15-meter nominal-diameter disk-gap-band parachute were conducted at Mach number and dynamic pressure conditions which bracketed the range postulated for the Viking '75 mission to Mars. Parachutes were deployed at supersonic, transonic, and subsonic speeds behind a simulated Viking entry capsule. All parachutes successfully deployed, inflated, and exhibited sufficient drag and stability for mission requirements. Basic parachute data including loads, drag coefficients, pull-off angles, and canopy area ratios are presented. Trajectory reconstruction and onboard camera data methods were combined to yield continuous histories of both parachute and test-vehicle angular motions which are presented for the period from parachute deployment through steady inflation.

Bendura, R. J.↗

Some experience with Barnwell-Sewall type correction to two-dimensional airfoil data

A series of airfoils were tested in the Langley 0.3-Meter Transonic Cryogenic Tunnel (TCT) at Reynolds numbers from 2 to 50 million. The 0.3-m TCT is equipped with Barnwell slots designed to minimize blockage due to the tunnel flow and ceiling. This design suggests that sidewall corrections for blockage is needed, and that a lifting airfoil produces a change in angle of attack. Sidewall correction methods were developed for subsonic and subsonic-transonic flow. Comparisons of theory with experimental data obtained in the 0.3-m TCT for two airfoils, the British NPL 9510 and the German R-4 are presented. The NPL 9510 was tested as part of the NASA/United Kingdom Joint Aeronautical Program and R-4 was tested as part f the DFVLR/NASA Advanced Airfoil Research Program. For the NPL 9510 airfoil, only those test points that one would anticipate being difficult to predict theoretically are presented.

Jenkins, R. V.↗

Drag characteristics of a disk-gap-band parachute with a nominal diameter of 1.65 meters at Mach numbers from 2.0 to 3.0

Supersonic wind-tunnel tests were conducted with disk-gap-band parachute models having a nominal diameter of 1.65 meters and geometric porosities of 10.0, 12.5, and 15.0 percent. Canopy inflation characteristics, angles of attack, and drag performance are presented for deployment behind forebody base extensions which were free to oscillate in pitch and yaw. The effect of increasing suspension-line length on canopy motions and drag performance is included, and the drag performance of a model with 12.5 percent geometric porosity is compared with results from flight tests of a parachute with a nominal diameter of 12.19 meters.

Mayhue, R. J.↗