Nucleation-controlled growth of superior lead-free perovskite Cs 3 Bi 2 I 9 single-crystals for high-performance X-ray detection

The organic-inorganic hybrid lead halide perovskites have emerged as a series of star materials for solar cells, lasers and detectors. However, the issues raised by the toxic lead element and marginal stability due to the volatile organic components have severely limited their potential applications. In this work, we develop a nucleation-controlled solution method to grow large size high-quality Cs 3 Bi 2 I 9 perovskite single crystals (PSCs). Using the technique, we harvest some centimeter-sized single crystals and achieved high device performance. We find that X-ray detectors based on PSCs exhibit high sensitivity of 1652.3 μC Gy air -1 cm -2 and very low detectable dose rate of 130 nGy air s -1 , both desired in medical diagnostics. In addition, its outstanding thermal stability inspires us to develop a high temperature X-ray detector with stable response at up to 100 °C. Furthermore, PSCs exhibit high X-ray imaging capability thanks to its negligible signal drifting and extremely high stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Metal-Free Photocatalysts

Solar fuels show great promise as clean, sustainable energy sources; however, established technologies are still plagued by high price, toxicity concerns, or low efficiencies. There is a critical need for inexpensive, benign materials that can effectively harness the sun’s energy. The overarching objective of this project is to evaluate the compatibility of novel material combinations for use as metal-free, heterojunction photocatalysts. Our central hypothesis is that by tuning the electronic structure of individual components in hybrid composites, via selective chemical modifications and physical stimuli to the interface, we can improve the photocatalytic properties of the overall assembly. We will determine factors that affect energy band gaps and band edge positions in isolated photocatalyst systems as well as explore routes to modulate heterojunction band alignments in composite assemblies. Our results will predict accessible pathways for charge carriers in new composite photocatalysts, facilitating access to more of the solar spectrum via inexpensive, environmentally-friendly material combinations.

14 SOLAR ENERGY↗

Fire tests for airplane interior materials

Large scale, simulated fire tests of aircraft interior materials were carried out in salvaged airliner fuselage. Two "design" fire sources were selected: Jet A fuel ignited in fuselage midsection and trash bag fire. Comparison with six established laboratory fire tests show that some laboratory tests can rank materials according to heat and smoke production, but existing tests do not characterize toxic gas emissions accurately. Report includes test parameters and test details.

Tustin, E. A.↗

A combustion products analyzer for contingency use during thermodegradation events on spacecraft

The Toxicology Laboratory at JSC and Exidyne Instrumentation Technologies (EIT) have developed a prototype Combustion Products Analyzer (CPA) to monitor, in real time, combustion products from a thermodegradation event on board spacecraft. The CPA monitors the four gases that are the most hazardous compounds (based on the toxicity potential and quantity produced) likely to be released during thermodegradation of synthetic materials: hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen cyanide (HCN), and carbon monoxide (CO). The levels of these compounds serve as markers to assist toxicologists in determining when the cabin atmosphere is safe for the crew to breathe following the contingency event. The CPA is a hand-held, battery-operated instrument containing four electrochemical sensors, one for each target gas, and a pump for drawing air across the sensors. The sensors are unique in their small size and zero-g compatibility. The immobilized electrolytes in each sensor permit the instrument to function in space and eliminate the possibility of electrolye leaks. The sample inlet system is equipped with a particulate filter that prevents clogging from airborne particulate matter. The CPA has a large digital display for gas concentrations and warming signals for low flow and low battery conditions. The CPA has flown on 13 missions beginning with STS 41 in Oct. 1990. Current efforts include the development of a microprocessor, an improved carbon monoxide sensor, and a ground-based test program to evaluate the CPA during actual thermodegradation of selected materials.

Wilson, Steve↗

Fundamental Insights into Cathode Stability: Linking Compositional Tuning and Local Coordination in Complex Metal Oxides under Aqueous Transformations

Compositional tuning of complex metal oxides in Li-ion battery materials influences their performance as well as their end-of-life behavior, in particular, the tendency to release toxic metal cations in aqueous solution. We modeled ternary variants of a parent LiCoO 2 delafossite structure by varying the metal identity and relative amounts. This yielded ten model formulations of Li(A 4/6 B 1/6 C 1/6 )O 2 , where the material is enriched with the A metal and doped with B and C, with Ni, Mn, Co, Fe, Al, V, and Ti as constituent metals. To assess their stability in aqueous conditions, metal release energetics were calculated using a combination of Density Functional Theory calculations and thermodynamics. Metal release in ternary oxides is dictated by subtle variations in the coordination environment of the leaving group. To identify governing chemical features across diverse compositions with varying local coordination environments, we leverage random forest regression and descriptor importance analysis. A key result is that metal–oxygen orbital hybridization, quantified using a projected density-of-states-derived descriptor, H d/p , provides a physically grounded measure of interaction strength that governs metal release energetics. This refined perspective goes beyond conventional oxidation state considerations and offers more robust insights for materials science. Finally, we model defect surface-bound O 2 dimer formation as a proxy for reactive oxygen species (ROS) generation. The results show that Ni-rich compositions more readily stabilize spin-polarized O 2 dimers, corroborating experimental reports of an increased ROS-driven biological response. In conclusion, our results establish a compositional and electronic basis for metal release and surface oxygen reactivity that form a rationale for complex metal oxide design principles.

36 MATERIALS SCIENCE↗

A New Type of Hybrid Copper Iodide as Nontoxic and Ultrastable LED Emissive Layer Material

Perovskite-based light-emitting diodes (PeLEDs) are promising candidates for next-generation solid-state lighting and display technologies. However, all current high-performance PeLEDs contain a toxic element (lead) and suffer from relatively low stability. Herein, we report a new type of lead-free LED using low-cost, eco-friendly, and robust copper(I) iodide hybrid material as the emissive layer (EML). Specifically, they are composed of copper iodide chains and organic ligands through ionic and coordinate bonds. Their remarkable stability and solution processability stem from this unique multifold bonding feature. High-quality thin films of 1D-Cu 4 I 6 (bttmp) 2 were fabricated by a simple, one-step spin-coating process. They exhibit high photoluminescence quantum yield (91%) and long-term air stability (>2000 h). An EQE of 5.02% was achieved for a prototype yellow LED using 1D-Cu 4 I 6 (bttmp) 2 EML. Its half-lifetime of 35.5 h obtained in open air outperforms that of most PeLEDs reported to date. Finally, this work opens a new direction for making LEDs based on ecofriendly and robust hybrid materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Colloidal Synthesis of Single-Layer Quasi-Ruddlesden–Popper Phase Bismuth-Based Two-Dimensional Perovskite Nanosheets with Controllable Optoelectronic Properties

Single- and few-layered two-dimensional (2D) nanomaterials have attracted intense research interest in the last two decades due to their unique electronic and optoelectronic properties leading to various potential applications. Herein, we report the colloidal synthesis of Bi-based 2D perovskite nanosheets (PEG6-NH 3 +) n Cs 3-n Bi 2 X 9 , where X = CI, Br, and I, through careful design of reaction conditions and selection of poly(ethylene glycol) (PEG6) surface passivating ligands. The 2D nanosheets are similar to 5 nm in thickness with micron-sized lateral dimensions and display composition-dependent band gap and work function modulation. Furthermore, small-angle X-ray scattering analysis substantiates that the individual inorganic crystal layer, Cs 3-n Bi 2 X 9 , is separated by the spacer, PEG6 ligand. Additionally, we determined that PEG6-NH 2 is an essential passivating ligand and spacer for the formation of Bi-based 2D nanosheets. Most importantly, controlled crystallization of the colloidal dispersion of nanosheets results in the formation of superlattice microstructures of the quasi-Ruddlesden-Popper phase. These microstructures can be exfoliated to ultrathin nanosheets by overcoming the van der Waals interaction between the organic passivating layers. The controlled synthesis of lead-free 2D perovskite nanosheets presented here can expand their utility to photocatalytic and optoelectronic applications with reduced toxicity.

36 MATERIALS SCIENCE↗

Towards Automated Design of Polymer Precursors for Rational Design of Porous Carbon-Materials [Slides]

Overview: Developed capability enables easy building of realistic polymer structures and a straightforward evaluation of polymer properties using different computational approaches. Topics of relevance to LANL mission: fundamental understanding of gas, vapor, ion, and liquid transport in polymer materials with applications in carbon capture, clean energy, hydrogen production (e.g., fuel cells and electrolyzes); Toxic element removal; Design of polymer binders in explosives. Workforce Development: Project provided a valuable opportunity to for a PI to manage a LANL research effort, expand collaborations (e.g., MPA division), and establish research topic that aligns with the LANL mission; The capability built was highlighted in the proposal "Versatile Polyolefins-Based Ionomer Platform for Next Generation Polymer Electrolyte Membrane and Hydrogen Production" lead by InnoSense LLC in collaboration with MPA-1 and T-1 as a response to DOE's call DE-FOA-0003003: Science Foundations for Energy Earthshots.

36 MATERIALS SCIENCE↗

Critical Design Elements for an On-Site Mercury Concentration and Holding Facility - 20175

Administrative changes and funding issues have delayed the Department of Energy (DOE) from establishing and commissioning a National Repository for mercury as required under the Mercury Export Ban Act (MEBA) of 2008. In the interim, a few hazardous waste Treatment, Storage, and Disposal Facilities (TSDFs) have been authorized to accept mercury classified as a hazardous waste as under Subtitle C of the Resource Conservation and Recovery Act (RCRA). Waste generators are charged (either by weight or by volume) for the waste they manifest to these TSDFs. In many cases, mercury and mercury compounds have chemically sorbed to (or physically lodged into) the interstitial spaces of a substrate material. This almost always causes the amount of waste generated to be unnecessarily large, due to the extra volume (or weight) of the accompanying, non-mercury materials. Depending on a multitude of factors, it could be financially beneficial for waste generators to take greater control of their mercury affairs by separating these substrate materials from the mercury and mercury compounds that have become associated with them. Building and operating an on-site mercury Concentration and Holding Facility (CHF) could help relieve a waste generator's overall cost burden. The purpose of such CHFs is not to treat or dispose of mercury, but to recover and concentrate mercury from bulky mercury-laden materials to the extent that the host substrate to which the mercury may have previously been sorbed could pass a Toxicity Characteristic Leaching Procedure (TCLP) test and either be disposed of at a conventional landfill, or be disposed of at a hazardous waste landfill, but absent additional restrictions specifically for mercury. A CHF represents a way for waste generators to save money by separating mercury from common host materials, concentrating it, and then safely storing it until transportation to an authorized TSDF takes place This paper focuses on the critical design elements waste generators should consider when designing and operating a mercury CHF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PHASE CHANGE MATERIAL FOR THERMAL ENERGY STORAGE IN BUILDINGS BASED ON SODIUM SULFATE DECAHYDRATE AND DISODIUM HYDROGEN PHOSPHATE DODECAHYDRATE

The worldwide increasing energy demand and 2050 net zero carbon target urge the globe to solve the energy challenge. Thermal Energy Storage (TES) has received significant attention in recent years as TES can be integrated into heating, ventilation, and air-conditioning systems where the energy would be stored during low-demand times and dispatched during high-demand times, resulting in controlling the peak load and improving energy savings. Material development is an integral part of TES. Salt hydrates are appealing due to cost-effectiveness, low- to no toxicity, and their high melting enthalpy, where energy is stored as latent heat. However, most salt hydrates are prone to incongruent melting (i.e., phase separation upon melting), which results in poor stability and large supercooling. In this study, we produced a highly stable novel energy storage material at a composition of 32 wt% sodium sulfate decahydrate, 52 wt% sodium phosphate dibasic dodecahydrate, 12 wt% milled expanded graphite, and 4 wt% borax. The material has a melting temperature of 28°C and an energy storage capacity of 167 kJ/kg with a supercooling of less than 3°C. The system showed no loss in energy storage performance after 150 cycles. The findings suggest that the novel energy storage material developed in this might be utilized in building heating and cooling applications.

Turnaoglu, Tugba↗

Sensing land pollution.

Land pollution is described in numerous ways by various societies. Pollutants of land are material by-products of human activity and range from environmentally ineffective to positively toxic. The pollution of land by man is centuries old and correlates directly with economy, technology and population. In order to remotely sense land pollution, standards or thresholds must be established. Examples of the potential for sensing land pollution and quality are presented. The technological capabilities for remotely sensed land quality is far advanced over the judgment on how to use the sensed data. Until authoritative and directive decisions on land pollution policy are made, sensing of pollutants will be a random, local and academic affair.

Bowden, L. W.↗

Fire test methodology for aerospace materials. 1: Thermal and smoke toxicological assessments of graphite/bismaleimide and graphite/epoxy systems

Both materials possess a high degree of thermal stability, with total heat release values being essentially identical under piloted ignition conditions over a range of 5 to 10 W/sq cm incident heat flux. The graphite/epoxy material had a tendency to auto-ignite at a lower heat flux (about 7 W/sq cm) and produced about 23 percent higher peak heat release rates, approximately 42 percent more carbon monoxide and considerably more smoke than the graphite/bismaleimide under conditions of piloted ignition. Toxicological potencies of smoke produced from the two composites were equivalent for 30 minute exposures. Potencies were also comparable to many common materials, such as wood. There was no evidence for the formation of an "unusual toxicant" nor for any short term post-exposure toxicological effects.

Kanakia, M. D.↗

Stereoscopic Vision System For Robotic Vehicle

Distances estimated from images by cross-correlation. Two-camera stereoscopic vision system with onboard processing of image data developed for use in guiding robotic vehicle semiautonomously. Combination of semiautonomous guidance and teleoperation useful in remote and/or hazardous operations, including clean-up of toxic wastes, exploration of dangerous terrain on Earth and other planets, and delivery of materials in factories where unexpected hazards or obstacles can arise.

Matthies, Larry H.↗

Evolution of Hardware and Philosophy of Emergency Response Actions on the International Space Station and Future Spacecrafts

Human spaceflight is dangerous for numerous reasons. This ranges from the dynamic environment of launching on a rocket, flying in space among the thousands and thousands pieces of space debris, to the hazards of re-entry & landing, as well as being surrounded by vehicle systems containing hazardous materials or gasses. In-flight emergencies fall into four categories: Rapid Depressurization, Fire, Toxic Spill, and Medical emergency. This paper will address the first three, which fall under the responsibility of the Environmental Control and Life Support (ECLS) Systems flight control and engineering teams. It will review the evolution of the International Space Station’s emergency response philosophy, procedures, training, and equipment changes over the years. The International Space Station (ISS) emergency equipment has evolved over the last two decades of operations in many ways, but in some it has remained the same. The core actions the flight crew takes to ensure team safety, personal safety, vehicle safety, and equipment safety has not changed. However, the equipment and capabilities provided to them have. From early days of minimal capability when the ISS consisted of a few modules, to today’s 30,000 ft^3 vehicle with over a dozen isolatable segments. From use of positive pressure O2 masks, to the development of respirators. From a lack of procedures for a deadly ammonia leak scenario to a memorized response utilizing numerous atmosphere measurement systems. This paper will review all these various areas that fall under the umbrella of “on-board emergencies”. In addition, the comparison to the planned emergency operations on the Orion vehicle will be reviewed. The Orion vehicle differs from the ISS in that it has no isolatable volume, being approximately 2% the size of ISS, as well as not having a quick return to earth capability.

Barry Tobias↗

Evolution of Hardware and Philosophy of Emergency Response Actions on the International Space Station and Future Spacecrafts

Human spaceflight is dangerous for numerous reasons. This ranges from the dynamic environment of launching on a rocket, flying in space among the thousands and thousands pieces of space debris, to the hazards of re-entry & landing, as well as being surrounded by vehicle systems containing hazardous materials or gasses. In-flight emergencies fall into four categories: Rapid Depressurization, Fire, Toxic Spill, and Medical emergency. This paper will address the first three, which fall under the responsibility of the Environmental Control and Life Support (ECLS) Systems flight control and engineering teams. It will review the evolution of the International Space Station’s emergency response philosophy, procedures, training, and equipment changes over the years. The ISS emergency equipment has evolved over the last two decades of operations in many ways, but in some it has remained the same. The core actions the flight crew takes to ensure team safety, personal safety, vehicle safety, and equipment safety has not changed. However, the equipment and capabilities provided to them have. From early days of minimal capability when the ISS consisted of a few modules, to today’s 30,000 ft^3 vehicle with over a dozen isolatable segments. From use of Russian gas masks to positive pressure O2 masks, to the development of respirators. From a lack of procedures for a deadly ammonia leak scenario to a memorized response utilizing numerous atmosphere measurement systems. This paper will review all these various areas that fall under the umbrella of “on-board emergencies”. In addition, the comparison to the planned emergency operations on the Orion vehicle will be reviewed. The Orion vehicle differs from the ISS in that it has no isolatable volume, being approximately 2% the size of ISS, as well as not having a quick return to earth capability.

Emergency↗

Methods and apparatus for gnotobiotic plant growth

The disclosure relates to a plant growth apparatus and related system to grow and maintain plants under controlled biotic conditions, for example to grow axenic (microbe-free) plants, gnotobiotic (defined microbiota) plants, and holoxenic (complex, or undefined microbiota) plants. This system allows aseptic bottom irrigation with water, soluble nutrients, chemicals, and/or microbiota. Plants can be inverted for dipping and/or vacuum infiltration. The system also allows for passive (gravity) drainage, thereby allowing for gas exchange and preventing root anoxia. A variety of plant growth substrates can be used within the plant growth apparatus as a plant growth medium. The plant growth apparatus, containing the growth substrate medium, can be completely flushed via the drainage port to remove potential toxic byproducts of the sterilization processes. The entire system is suitably constructed using autoclavable material.

59 BASIC BIOLOGICAL SCIENCES↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Toxicity of pyrolysis gases from polytetrafluoroethylene

A sample of polytetrafluoroethylene was evaluated for toxicity of pyrolysis gases, using various test conditions of the toxicity screening test method developed at the University of San Francisco. Time to death appears to be affected by the material of which the pyrolysis tube is made, with Monel tending to give longer times to death than quartz. When quartz tubes are used, time to death seems to be related to carbon monoxide concentration. When Monel tubes are used, carbon monoxide does not appear to be the principal toxicant.

Hilado, C. J.↗