At least 361 records · Page 20

Portable Luminescent Sensor Technologies for Economically Critical Metals

Presentation on the development of sensing materials and compact platforms for the photoluminescence-based detection of economically critical metals, including rare earth elements, cobalt, and aluminum. The important of detecting metals that interfere with critical metal processing, such as iron and aluminum, are also discussed. The presented results represent a significant step forward in reducing the economic and time costs associated with the characterization of metals during prospecting and downstream processing.

Crawford, Scott↗

Porous Polymer Structures with Tunable Mechanical Properties Using a Water Emulsion Ink

Recently, the manufacturing of porous polydimethylsiloxane (PDMS) with engineered porosity has gained considerable interest due to its tunable material properties and diverse applications. An innovative approach to control the porosity of PDMS is to use transient liquid phase water to improve its mechanical properties, which has been explored in this work. Adjusting the ratios of deionized water to the PDMS precursor during blending and subsequent curing processes allows for controlled porosity, yielding water emulsion foam with tailored properties. The PDMS-to-water weight ratios were engineered ranging from 100:0 to 10:90, with the 65:35 specimen exhibiting the best mechanical properties with a Young’s Modulus of 1.17 MPa, energy absorption of 0.33 MPa, and compressive strength of 3.50 MPa. This led to a porous sample exhibiting a 31.46% increase in the modulus of elasticity over a bulk PDMS sample. Dowsil SE 1700 was then added, improving the storage capabilities of the precursor. The optimal storage temperature was probed, with -60 °C resulting in great pore stability throughout a three-week duration. The possibility of using these water emulsion foams for paste extrusion additive manufacturing (AM) was also analyzed by implementing a rheological modifier, fumed silica. Fumed silica’s impact on viscosity was examined, revealing that 9 wt% of silica demonstrates optimal rheological behaviors for AM, bearing a viscosity of 10,290 Pa·s while demonstrating shear-thinning and thixotropic behavior. This study suggests that water can be used as pore-formers for PDMS in conjunction with AM to produce engineered materials and structures for aerospace, medical, and defense industries as sensors, microfluidic devices, and lightweight structures.

36 MATERIALS SCIENCE↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D Electrets of Ultrathin MoO 2 with Apparent Piezoelectricity

Since graphene, a variety of 2D materials have been fabricated in a quest for a tantalizing combination of properties and desired physiochemical behavior. 2D materials that are piezoelectric, i.e., that allow for a facile conversion of electrical energy into mechanical and vice versa, offer applications for sensors, actuators, energy harvesting, stretchable and flexible electronics, and energy storage, among others. Unfortunately, materials must satisfy stringent symmetry requirements to be classified as piezoelectric. Here, 2D ultrathin single-crystal molybdenum oxide (MoO 2 ) flakes that exhibit unexpected piezoelectric-like response are fabricated, as MoO 2 is centrosymmetric and should not exhibit intrinsic piezoelectricity. However, it is demonstrated that the apparent piezoelectricity in 2D MoO 2 emerges from an electret-like behavior induced by the trapping and stabilization of charges around defects in the material. Arguably, the material represents the first 2D electret material and suggests a route to artificially engineer piezoelectricity in 2D crystals. Specifically, it is found that the maximum out-of-plane piezoresponse is 0.56 pm V -1 , which is as strong as that observed in conventional 2D piezoelectric materials. The charges are found to be highly stable at room temperature with a trapping energy barrier of ≈2 eV.

36 MATERIALS SCIENCE↗

Irradiation Testing of Sensors - ASI Program Review 2022

This is a powerpoint presentation for the annual Advanced Sensors and Instrumentation (ASI) program webinar. The following is a summary of the presentation. Advanced instrumentation enables testing of nuclear fuels and materials in support of the US advanced nuclear technology industry. A number of promising sensor technologies are in the pipeline. The early part of sensor development can be done outside of the reactor environment, but full technical readiness requires experience gained from in-core performance testing. Customers usually have only one shot to conduct their irradiation experiments. Because of the high costs test sponsors are frequently reluctant to incorporate unproven technologies in reactor experiments. Therefore, it is vital to demonstrate newly-developed sensors in operational conditions, prior to incorporating them into long-term high-value experiments. Successful completion of these activities will create new monitoring capabilities in high-power test reactors (such as ATR) as well as specialty reactors such as TREAT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature locale sensors and related methods

Temperature locale sensors include an enclosure defining a sealed volume with a phase-change material therein at a known pressure. The phase-change material is formulated to exhibit a gas-to-solid phase change, without condensing to a liquid phase, at the known pressure and a targeted temperature, i.e., the material's “deposition temperature.” The phase-change material—while at least partially in gaseous form, either initially or after sublimation—is exposed to an environment with temperatures varying by location, including a maximum temperature above the phase-change material's deposition temperature and other temperatures at or below the deposition temperature. The gaseous phase-change material, in a location at the deposition temperature, solidifies from its gaseous phase to form solid grain deposits on a surface within the enclosure of the sensor. The solid deposits precisely identify the location of the specific, targeted deposition temperature.

Skifton, Richard S.↗

The 65 Elevated Risk Container Status Relative Humidity Measurements RFID RH/T Sensors in Containers [Slides]

In March of 2023, a memo was issued, drafted by the Container Management, Safety, and Engineering Team, identifying 65 elevated risk legacy containers for priority disposition at TA-55. These 65 were identified separately from the “typical” prioritization decision-making method used at TA-55 to disposition legacy items. This new technique gave important feedback and revealed improvement opportunities for the selection process of legacy containers for disposition. The DOE complex and TA-55 have a long history of nuclear operations and therefore the disposition of these legacy materials is vital.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-ray quantification of oxygen groups on diamond surfaces for quantum applications

Abstract Identifying the surface chemistry of diamond materials is increasingly important for device applications, especially quantum sensors. Oxygen-related termination species are widely used because they are naturally abundant, chemically stable, and compatible with stable nitrogen vacancy centres near the diamond surface. Diamond surfaces host a mixture of oxygen-related species, and the precise chemistry and relative coverage of different species can lead to dramatically different electronic properties, with direct consequences for near-surface quantum sensors. However, it is challenging to unambiguously identify the different groups or quantify the relative surface coverage. Here we show that a combination of x-ray absorption and photoelectron spectroscopies can be used to quantitatively identify the coverage of carbonyl functional groups on the { 100 } diamond surface. Using this method we reveal an unexpectedly high fraction of carbonyl groups ( > 9%) on a wide range of sample surfaces. Furthermore, through a combination of ab initio calculations and spectroscopic studies of engineered surfaces, we reveal unexpected complexities in the x-ray spectroscopy of oxygen terminated diamond surfaces. Of particular note, we find the binding energies of carbonyl-related groups on diamond differs significantly from other organic systems, likely resulting in previous misestimation of carbonyl fractions on diamond surfaces.

36 MATERIALS SCIENCE↗

Fiber-Based Distributed Hydrogen Measurement at High Temperatures

In this work, we discuss the implementation of evanescent field optical fiber sensors for distributed gas sensing of H2, focusing on results using a Ni / Gd-doped CeO2 nanocomposite sensing material for detection of low levels of H2 (0-4%) at 700 °C. This approach utilizes sensors prepared using a low-cost, wet chemical deposition process, in conjunction with a custom-built interrogator system leveraging optical time domain reflectometry (OTDR). Using a specially designed dual-gas flow reactor system, the sensor is tested by establishing a controlled equilibrium gradient of gas concentration. Initial results are shown using silica fiber, but provides a pathway for utilization with high temperature stable single crystal optical fiber for operation at higher temperatures and higher levels of H2 relevant for solid oxide fuel cell (SOFC) operating conditions.

Wuenschell, Jeffrey↗

Renewal: Coherent control of spin states in organic electronics – discovery and investigation of complex room-temperature magnetic quantum excitations

In the course of four funding cycles of this project, its research focused on the exploration and understanding of spin-dependent electronic processes in organic semiconductors. It aimed to investigate the potential of harnessing the spin degree of freedom in organic materials for various applications such as spin electronics, quantum information, sensors, and as well as quantum coherent spin phenomena of charge carrier states in organic semiconductors, with the aim to develop room-temperature-based quantum applications. Specifically, the project aimed to: Apply new diagnostic tools, i.e. spin spectroscopy techniques, for paramagnetic charge carrier states in organic semiconductors, based on coherent control with pulsed electron spin resonance to understand spin relaxation and spin mixing mechanisms in organic semiconductor materials and devices such as OLEDs. Explore the nature of charge carrier spin-coupling and pathways for its manipulation to control the physical behaviors of these materials. This involves investigating spin interactions through materials structure, composition, morphological dependencies, isotopic effects, and externally applied electric and magnetic fields, with the goal to manipulate electrical and optical material properties by adjusting spin-orbit, spin-dipolar, spin-exchange, as well as spin-hyperfine interactions to open up this materials class for new applications. Study spin-dependent charge carrier transport and recombination and how these observables are governed by spin-propagation, especially coherent spin propagation as well as collective spin-effects such as the spin-Dicke effect and resonant multi-photon magnetic dipole transitions. The project utilized pulsed electrically detected magnetic resonance (pEDMR) and pulsed optically detected magnetic resonance (pODMR) techniques over a wide frequency range. These techniques enabled the observation and quantification of various spin-spin coupling types, including spin-exchange, spin-dipolar, hyperfine, and spin-orbit interactions. The project will leverage low- to mid-frequency pEDMR/pODMR facilities and collaboration with the National High Magnetic Field Laboratory.

36 MATERIALS SCIENCE↗

Synthesizing intermetallic thermoelectric materials using metal flux growth method

With zero energy poverty by 2050 goals, exploring innovative energy technologies is essential. Thermoelectric materials (TEMs) have the potential to harness waste heat and convert it to electricity (e.g., for spacecraft power, sensors, and cryogenic cooling). Two limitations of thermoelectric compounds are their low efficiency and limited pool of materials. Optimizing the efficiency of TEMs is challenging due to the interdependent relationship between electrical and thermal conductivity. A deeper understanding of electronic properties and lattice thermal conductivity is necessary to “understand, predict and ultimately control” the thermoelectric properties of TEMs. Understanding the influence of light-atom-doping and intrinsic defects on the electronic properties of the f-element containing TEMs are important questions that need to be answered to design and synthesize TEMs with optimal parameters. The purpose of this work is to understand how doping f-element based TEMs with light elements, such as carbon and boron, would impact the crystal structure, bond lengths, band gaps, and thermoelectric characteristics. High-quality f¬-element containing intermetallic single crystals are grown in metal flux media. In molten metal flux growth method, one or more low-melting metals such as aluminum, gallium, tin, and bismuth are used in excess as the reaction medium. As these are solution-state reactions, we can use lower temperatures than solid-state reactions and isolate the kinetic products instead of the thermodynamically stable compound. Then these are characterized using X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy, magnetization, electrical and thermal conductivities, and thermoelectric power.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties). To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Advanced Manufactured Strain Sensors for Extreme Environments

Experimentation at irradiation test facilities are essential for reducing the innovation time of developmental fuels, fuel cladding, and structural materials employed in next-generation nuclear reactors. However, due to the harsh conditions generated in such reactors and limited instrumentation space, the evaluation of a material’s mechanical properties is often limited to characterization after the materials have been removed from reactor conditions, or post-irradiation examination. These experiments are costly, time-consuming, and fail to capture the critical time-evolving phenomena that occur during the irradiation experiments. Advanced manufactured digital image correlation patterns and strain sensor devices serve as two promising technologies that can be deployed in the confined and challenging orientations of these irradiation experiments while also providing key insight on salient materials phenomena (i.e., mechanical properties).To guide the development of the printed strain sensors prior to their deployment in critical experiments, the adhesion strength between the substrate and printed film interface is measured via tensile testing and a non-contact laser-induced spallation technique. The establishment of these process control steps helped guide the successful fabrication and testing of direct-write strain sensing devices discussed in this work. The fabrication process controls are necessary for enabling the sustained operation of these strain sensing device through experimentation and minimize the potential for premature failure.

36 - MATERIALS SCIENCE↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗