Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local oscillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Noise in Josepson effect mixers and the RSJ model

Josephson effect mixers have previously been observed to display 'excess' noise both in experiments with point contacts and in numerical simulations using the resistively shunted junction (RSJ) model. This excess noise causes the mixer noise temperature to be a factor of typically 20-100 times the physical temperature of the device. Previously, this excess was ascribed to conversion from unwanted sidebands of the local oscillator and Josephson frequencies and their harmonics. Our numerical modeling of the RSJ equations has led to a new understanding of the excess noise, which is simply due to the intrinsic Josephson oscillations of the device. In addition, we have extended the modeling to include the previously ignored case of finite device capacitance (i.e. RSJ capacitance parameter beta(sub c) does not equal 0, which is more realistic for lithographically defined Josephson such as shunted tunnel junctions or SNS bridges. For some cases, this yields an improvement of a factor of two in noise temperature from the zero capacitance models. We will discuss the device parameters which optimize the mixer performance for frequencies approaching the characteristic frequency of the device, which is given by the Josephson frequency at the I(sub c)R(sub n) voltage (nu = 2eI(sub c)R(sub n)/h). These modeling results predict good conversion efficiency and a noise temperature within a factor of a few of the physical temperature. Experiments are in progress to determine the accuracy of this modeling using a waveguide mixer at 100 GHz with optimized, resistively shunted Nb tunnel junctions. If the modeling results are valid, they are particularly encouraging for mixers in the submillimeter regime, given the possibility of obtaining non-hysteretic Josephson devices with I(sub c)R(sub n) products in excess of a millivolt, using for instance, high-T(sub c) SNS bridges. We discuss the modifications to the classical RSJ model which are necessary in the quantum regime (h nu greater than kT), and conclude the Josephson mixers may attain noise temperatures less than ten times the quantum limit at high frequencies.

Schoelkopf, R.↗

Resonant tunneling diodes as sources for millimeter and submillimeter wavelengths

High-quality Resonant Tunneling Diodes have been fabricated and tested as sources for millimeter and submillimeter wavelengths. The devices have shown excellent I-V characteristics with peak-to-valley current ratios as high as 6:1 and current densities in the range of 50-150 kA/cm(exp 2) at 300 K. Used as local oscillators, the diodes are capable of state of the art output power delivered by AlGaAs-based tunneling devices. As harmonic multipliers, a frequency of 320 GHz has been achieved by quintupling the fundamental oscillation of a klystron source.

Vanbesien, O.↗

InGaAs/InP heteroepitaxial Schottky barrier diodes for terahertz applications

This paper explores the feasibility of planar, sub-harmonically pumped, anti-parallel InGaAs/InP heteroepitaxial Schottky diodes for terahertz applications. We present calculations of the (I-V) characteristics of such diodes using a numerical model that considers tunneling. We also present noise and conversion loss predictions of diode mixers operated at 500 GHz, and obtained from a multi-port mixer analysis, using the I-V characteristics predicted by our model. Our calculations indicate that InGaAs/InP heteroepitaxial Schottky barrier diodes are expected to have an I-V characteristic with an ideality factor comparable to that of GaAs Schottky diodes. However, the reverse saturation current of InGaAs/InP diodes is expected to be much greater than that of GaAs diodes. These predictions are confirmed by experiment. The mixer analyses predict that sub-harmonically pumped anti-parallel InGaAs/InP diode mixers are expected to offer a 2 dB greater conversion loss and a somewhat higher single sideband noise temperature than their GaAs counterparts. More importantly, the InGaAs/InP devices are predicted to require only one-tenth of the local oscillator power required by similar GaAs diodes.

Bhapkar, Udayan V.↗

All-solid-state radiometers for environmental studies to 700 GHz

We report results with an all-solid-state radiometer for measurements of the ClO molecule at 649 GHz. The project is part of a program to provide low-noise, low-weight, low-power radiometers for space operation, and special effort has been expended on the development of high-efficiency solid-state frequency multipliers and Schottky-barrier mixers with low local oscillator power requirements. The best measured system noise temperature was 1750 K with the mixer and preamplifier cooled to 77 K. The mixer diode was easily pumped into saturation, indicating that the design has excellent prospects of operating at higher frequencies - our present design goal being 1 THz. We comment on the principal design features of such systems and will report on stratospheric measurements performed with this system.

Zimmermann, Ralph↗

Design and construction of a prototype ACTS propagation terminal

The launch schedule for the Advanced Communication Technology Satellite (ACTS) spacecraft did not leave sufficient time for completion of the prototype ACTS Propagation Terminals (APT) prior to initiation of the APT production phase. In fact, the approach used was to construct and test all subassemblies of the terminal with special emphasis on the technically challenging portions. These include the RF front end that uses a state-of-the-art down converter which integrates a low noise amplifier, mixer, post amplifier, filter, and local oscillator port frequency doubler into a single small package. In addition, a new digital receiver that uses the latest DSP technology was developed. Both of these subassemblies were thoroughly tested. The highest risk technology in the APT program was the digital receiver. Several candidate algorithms and DSP chips were investigated early on, primarily under JPL sponsorship. A receiver was constructed based on Texas Instruments chip. The final prototype digital receiver was one based on an Analog Devices chip. The design and test results are documented in a report prepared for this grant. A Primary Design Review (PDR) was conducted 30 May 1991, and a Critical Design Review was held 7 Jul. 1992. Final complete documentation of the APT's will appear in the form of three reports: a hardware description report, a report on the data collection code (ACTS VIEW), and a report on the preprocessing code.

Stutzman, Warren↗

An improved linear ion trap physics package

This article describes an improvement in the architecture of the physics package used in the Linear Ion Trap (LIT)-based frequency standard recently developed at JPL. This new design is based on the observation that ions can be moved along the axis of an LIT by applied dc voltages. The state selection and interrogation region can be separated from the more critical microwave resonance region where the multiplied local oscillator signal is compared with the stable atomic transition. This separation relaxes many of the design constraints of the present units. Improvements include increased frequency stability and a substantial reduction in size, mass, and cost of the final frequency standard.

Prestage, J. D.↗

Low data rate coherent optical link demonstration using frequency stabilized solid state lasers

A low data rate laboratory heterodyne link demonstration operating at 1.06 micron using frequency stabilized Nd:YAG lasers was implemented. The data was modulated onto the optical carrier at 100 kbps using binary pulse position modulation. Phase coherent reception was achieved by closing the receiver phase tracking loop around the piezo-electric and temperature-tuned local oscillator laser. Initial frequency acquisition was accomplished by linearly scanning the LO frequency over the uncertainty range while a combined frequency and phase tracking loop searches for a lock indicator signal. The link performance was experimentally evaluated and compared to the theoretical predictions.

Chen, CHIEN-C.↗

Optically pumped submillimeter laser heterodyne receivers - Astrophysical observations and recent technical developments

NASA's prospective sub-mm-wave astrophysical missions encompass the Small Explorer Submillimeter Wave Astronomy Satellite, scheduled for launch in 1995, the Submillimeter Intermediate Mission, and the Large Deployable Reflector; until these are operational, sub-mm observations will be conducted at mountain sites and aboard aircraft platforms. Attention is presently given to the technical challenges faced by terahertz-range receiver developers, and it is noted that optically pumped sub-mm lasers furnish the only practical local oscillation source for heterodyne receivers in the 600-3000 GHz range. An account is given of ground-based and airborne astrophysical applications of heterodyne receivers.

Chin, Gordon↗

Ground-based microwave remote sensing of water vapor in the mesosphere and stratosphere

A ground-based, portable microwave radiometer that will be used to measure water vapor in the 30-80-km altitude region, and is to operate 24 hr a day, is described. The thermally excited 22.235-GHz rotational-transition line of water vapor is employed. The emission from this region produces a signal with an apparent brightness temperature of the order 0.1 to 0.5 K. A steerable reflector is used to provide optimal viewing angles, depending on the geographic location and season. Periodic tipping curve scans by this reflector permit determination of the amount of tropospheric correction that is applied to the data. All local oscillators in the receiver are crystal-controlled so that narrow-band spectral analysis of the received line shape can be performed.

Croskey, Charles L.↗

Experimental verification of the photodiode theory of SIS mixers

The authors describe the characterization and interpretation of the performance of SIS receivers within the framework of the photodiode theory of mixing. The quantum efficiency plays a dominant role in the theory, and a simple method of accurately measuring this parameter is presented. It is demonstrated that the quantum efficiency measurements can be conveniently made on a standard radio astronomy receiver and combined with the usual hot and cold load characterization to improve the understanding of the receiver's performance. The measurements verify that the photodiode theory of mixing accurately describes the receiver noise even at local-oscillator power levels well above the linear response range. The results for receivers operating at 100 and 240 GHz verify the utility of this approach. These methods should also prove useful in evaluating submillimeter receivers.

Woody, David P.↗

A 100Mbps coherent optical link demonstration using frequency stabilized solid state lasers

The design, implementation, and performance evaluation of a 100Mbps binary phase shift keying (BPSK) coherent optical link using frequency stabilized solid state lasers is described. In this demonstration, the transmitted data is binary phase modulated at 100Mbps using an external resonant cavity phase modulator. At the receiving end, the signal is detected using a balanced heterodyne detector. An auxiliary frequency tracking loop (FTL) is used to help the initial frequency acquisition before handing over to the carrier phase tracking loop. The FTL is implemented using a delay line discriminator, and the detected frequency error is fed back to the local oscillator laser to close the tracking loop. Phase coherent reception is achieved by synchronizing the carrier phase using a Costas tracking loop. The demonstration showed that a high data rate phase coherent optical link can be implemented using frequency stabilized solid state lasers.

Chen, CHIEN-C.↗

A 200 GHz tripler using a single barrier varactor

The GaAs Schottky varactor diode is the nonlinear device most commonly used for submillimeter wave harmonic generation. Output power adequate to serve as a local oscillator source for SIS tunnel junctions has been demonstrated with whisker-contacted GaAs Schottky varactor multipliers in waveguide mounts up to about 800 GHz. In this paper, we present results for a tripler to 200 GHz using a new multiplier device, the single barrier varactor (SBV). This new varactor has potential advantages such as stronger nonlinearities or special symmetry, which make it attractive for submillimeter wave frequency multiplication. The performance of a tripler using a SBV over a output frequency range from 186 to 207 GHz has been measured in a crossed waveguide mount. The theoretical performance of the device has been calculated using large signal analysis. A comparison of theoretical and measured results and a discussion of various losses in the mount and the varactor have also been presented.

Choudhury, Debabani↗

Generating Submillimeter-Wave Frequencies From Laser Pulses

Semiconductor photoconductive switches generate electrical pulses containing submillimeter-wavelength carrier signals (frequency between 300 and 3,000 GHz) and harmonics thereof when illuminated with short-rise-time pulses from lasers. Device of this type used as local oscilator in heterodyne submillimeter-wave receiver. Electrical output of device coupled via transmission line, waveguide, or antenna to mixer circuitry of receiver. Phase delays between optically activated semiconductor switches determine output carrier frequencies. N electrical pulses generated by each laser pulse. Thus, fundamental output frequency is N times laser-pulse-repetition rate.

Spencer, Michael G.↗

Accuracy metrics for judging time scale algorithms

Time scales have been constructed in different ways to meet the many demands placed upon them for time accuracy, frequency accuracy, long-term stability, and robustness. Usually, no single time scale is optimum for all purposes. In the context of the impending availability of high-accuracy intermittently-operated cesium fountains, we reconsider the question of evaluating the accuracy of time scales which use an algorithm to span interruptions of the primary standard. We consider a broad class of calibration algorithms that can be evaluated and compared quantitatively for their accuracy in the presence of frequency drift and a full noise model (a mixture of white PM, flicker PM, white FM, flicker FM, and random walk FM noise). We present the analytic techniques for computing the standard uncertainty for the full noise model and this class of calibration algorithms. The simplest algorithm is evaluated to find the average-frequency uncertainty arising from the noise of the cesium fountain's local oscillator and from the noise of a hydrogen maser transfer-standard. This algorithm and known noise sources are shown to permit interlaboratory frequency transfer with a standard uncertainty of less than 10(exp -15) for periods of 30-100 days.

Douglas, R. J.↗

Hydrogen masers and cesium fountains at NRC

The NRC masers H-3 and H-4 have been operating since June 1993 with cavity servo control. These low-flux active H masers are showing stabilities of about 10(exp -15) from 1 hour to several days. Stability results are presented, and the current and planned uses of the masers are discussed. A cesium fountain primary frequency standard project has been started at NRC. Trapping and launching experiments with the goal of 7 m/s launches are beginning. We discuss our plans for a local oscillator and servo that exploit the pulsed aspect of cesium fountain standards, and meet the challenge of 10(exp -14) tau(exp -1/2) stability without requiring masers. At best, we expect to run this frequency standard initially for periods of hours each working day rather than continuously for years, and so frequency transfer to outside laboratories has been carefully considered. We conclude that masers (or other even better secondary clocks) are required to exploit this potential accuracy of the cesium fountain. We present and discuss our conclusion that it is feasible to transfer frequency in this way with a transfer-induced uncertainty of less than 10(exp -15), even in the presence of maser frequency drift and random walk noise.

Boulanger, J.-S.↗

Laser/lidar analysis and testing

Section 1 of this report details development of a model of the output pulse frequency spectrum of a pulsed transversely excited (TE) CO2 laser. In order to limit the computation time required, the model was designed around a generic laser pulse shape model. The use of such a procedure allows many possible laser configurations to be examined. The output pulse shape is combined with the calculated frequency chirp to produce the electric field of the output pulse which is then computationally mixed with a local oscillator field to produce the heterodyne beat signal that would fall on a detector. The power spectral density of this heterodyne signal is then calculated. Section 2 reports on a visit to the LAWS laser contractors to measure the performance of the laser breadboards. The intention was to acquire data using a digital oscilloscope so that it could be analyzed. Section 3 reports on a model developed to assess the power requirements of a 5J LAWS instrument on a Spot MKII platform in a polar orbit. The performance was assessed for three different latitude dependent sampling strategies.

Spiers, Gary D.↗

A 1- to 10-GHz downconverter for high-resolution microwave survey

A downconverter was designed, built, and tested for the High Resolution Microwave Survey project. The input frequency range is 1 to 10 GHz with instantaneous bandwidth of 350 MHz and dynamic range of 125 dB/Hz. Requirements were derived for the local oscillators and special design techniques were implemented to achieve the high degree of spectral purity required.

Mcwatters, D.↗

BIB mixers

We have determined that the multi-pin 'microprocessor style' packages in which current Blocked Impurity Band (BIB) devices are mounted will not meet our IF bandwidth spec of greater than 2 GHz for a practical mixer. Hence we have started to repackage the Ga:Ge BIB devices in new microwave compatible packages. The smaller size of the microwave package mount necessitates cutting the BIB array down to include only the 3 smallest detectors: 0.2, 0.4, and 0.6 mm sq. A FIR beam incident at f/1.5 can be focussed on the smallest element for wavelengths shorter than 100 microns. A more typical (easier) beam convergence of f/3 will require 0.4 mm elements at 100 microns and 0.6 mm elements at 170 microns wavelength. Since the device capacitance (parasitic loss) scales with detector size, there is a tradeoff of speed of response and optical convenience. Our existing optics produce only the slower convergence beam, so we need to redesign the optical layout and are looking at long focal length all-reflective microscope objectives. BIB detectors and the edge-coupled microbolometers have restricted IF bandwidths, an order of magnitude less than what is possible with the Schottky-diode mixers we currently use for astronomical observations. Consequently the frequencies of the FIR laser lines must be close to the astronomical line of interest to be an effective Local Oscillator (LO). We have therefore begun a coordinated effort to discover and measure new FIR laser transition lines in close frequency coincidence with important astrophysical lines. Most of this effort involves pumping isotopic variants of known good laser molecules with laser lines from isotopic variants of CO2. We have been most successful in detecting new FIR lines in deuterated ammonia. One line in particular is very close to the frequency of HD rotational line at 2675 GHz.

Source record↗