Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Load Aggregation Methods for Quasi-Static Power Flow Analysis on High PV Penetration Feeders

This paper focuses on developing load aggregation methodologies for analyzing quasi-static power flows on high photovoltaic penetrated distribution feeders so statistics of the transformer loading levels, voltage ramping events, and voltage violation events can be properly quantified. A load profile aggregation algorithm is presented to construct 24-hour, minute-by-minute load profiles at each load node on the test feeder so the aggregation of those load profiles matches the load profile measured at the feeder head. A quasi-static power flow analyses are conducted to obtain minute-by-minute power flow results that can be used to quantify transformer overloads and voltage issues in distribution systems. To demonstrate the effectiveness of the developed methodology, the IEEE-123 test feeder model and residential load profiles collected from the PECAN street project are used in the case studies. Simulation results show that the method is effective in producing the required operation statistics.

Load aggregaton, PV integration, quasi-static powe↗

Mechanical Response of Castlegate Sandstone under Hydrostatic Cyclic Loading

The stress history of rocks in the subsurface affects their mechanical and petrophysical properties. Rocks can often experience repeated cycles of loading and unloading due to fluid pressure fluctuations, which will lead to different mechanical behavior from static conditions. This is of importance for several geophysical and industrial applications, for example, wastewater injection and reservoir storage wells, which generate repeated stress perturbations. Laboratory experiments were conducted with Castlegate sandstone to observe the effects of different cyclic pressure loading conditions on a common reservoir analogue. Each sample was hydrostatically loaded in a triaxial cell to a low effective confining pressure, and either pore pressure or confining pressure was cycled at different rates over the course of a few weeks. Fluid permeability was measured during initial loading and periodically between stress cycles. Samples that undergo cyclic loading experience significantly more inelastic (nonrecoverable) strain compared to samples tested without cyclic hydrostatic loading. Permeability decreases rapidly for all tests during the first few days of testing, but the decrease and variability of permeability after this depend upon the loading conditions of each test. Cycling conditions do affect the mechanical behavior; the elastic moduli decrease with the increasing loading rate and stress cycling. The degree of volumetric strain induced by stress cycles is the major control on permeability change in the sandstones, with less compaction leading to more variation from measurement to measurement. The data indicate that cyclic loading degrades permeability and porosity more than static conditions over a similar period, but the petrophysical properties are dictated more by the hydrostatic loading rate rather than the total length of time stress cycling is imposed.

58 GEOSCIENCES↗

Radioactive Demonstration Of Mineralized Waste Forms Made From Hanford Low Activity Waste (Tank Farm Blend) By Fluidized Bed Steam Reformation (FBSR)

The U.S. Department of Energy’s Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford’s tank waste. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in the time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Supplemental Treatment is likely to be required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. The Supplemental Treatment chosen will immobilize that portion of the retrieved LAW that is not sent to the WTP’s LAW Vitrification facility into a solidified waste form. The solidified waste will then be disposed on the Hanford site in the Integrated Disposal Facility (IDF). Fluidized Bed Steam Reforming (FBSR) offers a moderate temperature (700-750°C) continuous method by which LAW can be processed irrespective of whether the waste contain organics, nitrates, sulfates/sulfides, chlorides, fluorides, volatile radionuclides or other aqueous components. The FBSR technology can process these wastes into a crystalline ceramic (mineral) waste form. The mineral waste form that is produced by co-processing waste with kaolin clay in an FBSR process has been shown to be comparable to LAW glass, i.e. leaches Tc-99, Re and Na at <2g/m 2 during ASTM C1285 (Product Consistency) durability testing. Monolithing of the granular FBSR product was investigated to prevent dispersion during transport or burial/storage. Monolithing in an inorganic geopolymer binder, which is amorphous, macro-encapsulates the granules, and the monoliths pass ANSI/ANS 16.1 and ASTM C1308 durability testing with Re achieving a Leach Index (LI) of 9 (the Hanford Integrated Disposal Facility, IDF, criteria for Tc-99) after a few days and Na achieving an LI of >6 (the Hanford IDF criteria for Na) in the first few hours. The granular and monolithic waste forms also pass the EPA Toxicity Characteristic Leaching Procedure (TCLP) for all Resource Conservation and Recovery Act (RCRA) components at the Universal Treatment Standards (UTS). Two identical Benchscale Steam Reformers (BSR) were designed and constructed at SRNL, one to treat non-radioactive simulants and the other to treat actual radioactive wastes. The results from the non-radioactive BSR were used to determine the parameters needed to operate the radioactive BSR in order to confirm the findings of non-radioactive FBSR pilot scale and engineering scale tests and to qualify an FBSR LAW waste form for applications at Hanford. Radioactive testing commenced using SRS LAW from Tank 50 chemically trimmed to look like Hanford’s blended LAW known as the Rassat simulant as this simulant composition had been tested in the non-radioactive BSR, the non-radioactive pilot scale FBSR at the Science Applications International Corporation-Science and Technology Applications Research (SAIC-STAR) facility in Idaho Falls, ID and in the TTT Engineering Scale Technology Demonstration (ESTD) at Hazen Research Inc. (HRI) in Denver, CO. This provided a “tie back” between radioactive BSR testing and non-radioactive BSR, pilot scale, and engineering scale testing. Approximately six hundred grams of non-radioactive and radioactive BSR product were made for extensive testing and comparison to the non-radioactive pilot scale tests performed in 2004 at SAIC-STAR and the engineering scale test performed in 2008 at HRI with the Rassat simulant. The same mineral phases and off-gas species were found in the radioactive and non-radioactive testing. The granular ESTD and BSR products (radioactive and non-radioactive) were analyzed for total constituents and durability tested as a granular waste form. A subset of the granular material was stabilized in a clay based geopolymer matrix at 42% and 65% FBSR loadings and durability tested as a monolith waste form. The 65 wt% FBSR loaded monolith made with clay (radioactive) was more durable than the 67-68 wt% FBSR loaded monoliths made from fly ash (non-radioactive) based on short term PCT testing. Long term, 90 to 107 day, ASTM C1308 testing (similar to ANSI/ANS 16.1 testing) was only performed on two fly ash geopolymer monoliths at 67-68 wt% FBSR loading and three clay geopolymer monoliths at 42 wt% FBSR loading. More clay geopolymers need to be made and tested at longer times at higher FBSR loadings for comparison to the fly ash monoliths. Monoliths made with metakaolin (heat treated) clay are of a more constant composition and are very reactive as the heat treated clay is amorphous and alkali activated. The monoliths made with fly ash are subject to the inherent compositional variation found in fly ash as it is a waste product from burning coal and it contains unreactive components such as mullite. However, both the fly ash and the clay based monoliths perform well in long term ASTM C1308 testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power Quality and Load Capacity Evaluations of an Electric Vehicle for Multi-Robot System Applications

This paper evaluates the capability of a fully electric pickup truck, using the Ford F-150 Lightning as an example, to provide power to the circuit of a multi-robot system. The case study was conducted on a simulated INL Autonomous Pit Exploration System (APES) designed for the inspection of nuclear waste tank pits. Through a series of controlled tests, the vehicle’s power delivery consistency, load-handling capability, and battery performance were assessed under various conditions. First of all, the load test demonstrated that the vehicle provided stable power with low distortion and no unexpected interruptions. Second, during the operational limit test, the 240V system sustained loads up to 7.4 kW before tripping, providing insights into its operational limits. Last but not least, during a simulated full-scale APES operation, the vehicle’s battery depleted by only 6% over an hour, indicating sufficient capacity for extended use while retaining reserve power for transportation needs. This study highlights the potential of electric vehicles as reliable power sources for field operations, contributing to the advancement of sustainable technologies by reducing reliance on traditional fossil fuel generators and promoting the integration of clean energy solutions in remote and challenging environments.

Electric vehicle↗

Coupled geomechanics and flow modeling of thermally induced compaction in heavy oil diatomite reservoirs under cyclic steaming

We report shallow, heavy oil diatomite reservoirs produced using cyclic steaming are often associated with significant subsidence. In cases where the pore pressure is not allowed to deplete noticeably, observed subsidence suggests a mechanism other than pressure decline is responsible. We perform coupled flow and geomechanics modeling to determine whether thermally induced compaction of the reservoir rock could play an important role in subsidence. First, we model laboratory-scale tests on diatomite samples subjected to mechanical and thermal loads. During these tests, substantial non-recoverable thermal compaction was measured. Using the modified Cam-clay model as a basis, thermally induced compaction is implemented by reducing the size of the yield surface as a function of temperature. This leads to a satisfactory modeling of the test results. Second, this new approach is used to model a symmetric pattern of wells in a generic heavy oil diatomite field produced using cyclic steaming. Results from simulations that consider or neglect thermally induced diatomite compaction show that thermal effects can potentially induce significant inelastic pore volume reduction and substantial subsidence.

58 GEOSCIENCES↗

Grid Simulator for Testing a Wind Turbine on Offshore Floating Platform

An important aspect of such offshore testing of a wind turbine floating platform is electrical loading of the wind turbine generator. An option of interconnecting the floating wind turbine with the onshore grid via submarine power cable is limited by many factors such as costs and associated environmental aspects (i.e., an expensive and lengthy sea floor study is needed for cable routing, burial,etc). It appears to be a more cost effective solution to implement a standalone grid simulator on a floating platform itself for electrical loading of the test wind turbine. Such a grid simulator must create a stable fault-resilient voltage and frequency bus (a micro grid) for continuous operation of the test wind turbine. In this report, several electrical topologies for an offshore gridsimulator were analyzed and modeled.

17 WIND ENERGY↗

LA-R43S6-L1 Postshot Report [Slides]

The Ranchero LA-R43S6-L1 test (formerly referred to as LA-43S-L1. The R specifically designates it is a Ranchero device and the 6 indicates a 6” high explosive charge diameter in anticipation of using larger diameters in the future.) was conducted on 3/8/17 with good success. The experiment was the first test of a “Swooped” Ranchero flux compression generator (FCG), and the load for the test was an aluminum imploding liner. In addition to the swoop, the stator was anodized to provide an insulating layer instead of one or more layers of polyethylene as had been the case for all earlier Ranchero tests. Using the Firing point TA-39-88 capacitor bank, 3.5 MA was delivered to the FCG for the initial magnetic field, and 36.4 MA were delivered to the load having an initial inductance of 2.5 nH. Implosion speeds over 1.1 cm/us were recorded, which exceeds previous LANL solid liner experimental results. The test was diagnosed with 18 PDV channels, 12 of which recorded liner implosion data, and the other 6 of which tracked the FCG armature during flux compression. These armature expansion data recorded during flux compression are the first of their kind, and it was previously unknown, due to unknown effects of the SF 6 in the flux compression volume, whether or not the expansion could be recorded using the PDV technique. Post shot 2D MHD calculations employed a complete external circuit model, and an improved flux diffusion model not available prior to the test. Results from these simulations show very good agreement with the experimental result. Four PDV channels recorded the liner implosion viewed radially outward from the center of the liner. All four of these probes recorded implosion velocities greater that 1 cm/µs, with the cylindrical center displaced by ~2 mm from actual center. Four PDV channels looked at +10° angles from the CMU wall, and four looked at -10° angles. A glide plane interaction is shown moving toward the center of the liner in MHD calculations, and PDV probes provide confirmation. The high explosive (HE) in the LA-R43S6-L1 test was PBX 9501 which had to be glued together in many pieces, and the test was preceded by a camera test to verify that the PBX 9501 could be assembled with acceptable tolerance in glue joints to prevent severing the armature during expansion. The camera test verified an acceptable armature performance, and results are given in complete detail in a post shot report LA-UR-19-20124, and summarized here. This report provides complete detail of the considerable body of data obtained on the test and in the post shot calculations. It is prepared in Power Point for ease of preparation and future review. Shot documentation available in the LANL on-line library are included as references, and non-referenceable documents will be cited and stored in an LA- R43S6-L1 post shot folder stored on an M-6 shared drive. Fabrication drawings are also maintained in an M-6 shared drive and paper files are available from M-6 personnel. This report will be maintained as a PowerPoint document on the shared drive, as well, since included movies will play and graphs from Excel files retain information in the PowerPoint versions. PDF versions are required for clearance and are not to large to send by e-mail.

42 ENGINEERING↗

On-Track Measurement of Road Load Changes in Two Close-Following Vehicles: Methods and Results

As emerging automated vehicle technology is making advances in safety and reliability, engineers are also exploring improvements in energy efficiency with this new paradigm. Powertrain efficiency receives due attention, but also impactful is finding ways to reduce driving losses in coordinated-driving scenarios. Efforts focused on simulation to quantify road load improvements require a sufficient amount of background validation work to support them. This study uses a practical approach to directly quantify road load changes by testing the coordinated driving of two vehicles on a test track at various speeds (64, 88, 113 km/h) and vehicle time gaps (0.3 to 1.3 s). Axle torque sensors were used to directly measure the load required to maintain steady-state speeds while following a lead vehicle at various gap distances. Through trial and error, test methods were developed that appear to provide satisfactory results, considering the challenges of track testing under real-world conditions (wind, weather, temperature changes, etc.). We found that total road load was reduced by about 10-12% at an optimum gap time of 0.25 to 0.4 s. Challenges that were encountered included less repeatability of load measurements at short gap distances and powertrain mode switching (from a hybrid vehicle) that rendered the 88-km/h results less useful. This study will provide the framework for further investigations on coordinated-driving road load using track testing methods.

Duoba, Michael↗

Comparing State-Space Multivariable Controls to Multi-SISO Controls for Load Reduction of Drivetrain-Coupled Modes on Wind Turbines Through Field-Testing

In this paper we present results from an ongoing controller comparison study at the National Renewable Energy Laboratory's (NREL's) National Wind Technology Center (NWTC). The intention of the study is to demonstrate the advantage of using modern multivariable methods for designing control systems for wind turbines versus conventional approaches. We will demonstrate the advantages through field-test results from experimental turbines located at the NWTC. At least two controllers are being developed side-by-side to meet an incrementally increasing number of turbine load-reduction objectives. The first, a multiple single-input, single-output (m-SISO) approach, uses separately developed decoupled and classicially tuned controllers, which is, to the best of our knowledge, common practice in the wind industry. The remaining controllers are developed using state-space multiple-input and multiple-output (MIMO) techniques to explicity account for coupling between loops and to optimize given known frequency structures of the turbine and disturbance. In this first publication from the study, we present the structure of the ongoing controller comparison experiment, the design process for the two controllers compared in this phase, and initial comparison results obtained in field-testing.

17 WIND ENERGY↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Verification Problems for Parameterized Load Curves in DYNA3D

Two verification problems are presented which test a set of newly implemented load curve features in the explicit finite element program DYNA3D. Each test consists of a single element, with the velocity of each node specified via a different load curve type. The first test covers initialization and run-time execution of these new features, while the second test covers redefinition of load curves upon restart. The proposed problems may be easily extended to test additional load curve features.

42 ENGINEERING↗

Execution of Targeted Experiments to Inform BISON for ATF Materials: An Advanced Approach to Tube Burst Testing

This report describes a new, advanced experimental approach for testing tube specimens loaded by internal pressure. The approach allows conventional tube burst testing to be performed and employs digital image recording and analysis for conducting noncontact optic strain measurements. Section 1 provides a brief introduction and motivation for the project. Section 2 describes the selected approach and provides technical details regarding the modified experimental tube burst system: a commercial infrared furnace redesigned to support this work by adding two 50-mm- diameter optic ports to make the specimen visible during the burst tests, and a digital camera used to record specimen images, lens, and optic filters. Section 3 briefly analyzes a typical burst test and the digital image correlation dataset, recorded during the experiment, and discusses the experiment outcome including local strains along the tube specimen. Additionally, section 3 focuses on the issues influencing the in situ strain measurement accuracy and final results and suggests changes in the experimental scheme to improve data quality and reliability. The conclusion summarizes the work performed to date and discusses possible future activity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical testing of hydrided fuel cladding

During light water reactor operations, hydrogen is generated from the oxidation of zirconium alloy materials. This hydrogen can be absorbed into the cladding and form zirconium hydrides. At high temperatures and hoop stresses, these normally circumferential oriented hydrides in high burnup used nuclear fuel (HB-UNF) may reorient in the radial direction and affect the mechanical properties of the cladding. Understanding these changes in mechanical properties will aid in analyzing how UNF will perform during storage and transportation. Systems, presented in the article, have been designed to introduce hydrides into cladding specimens, to reorient cladding hydrides, and to test and measure the mechanical properties of these specimens. The hydriding systems consist of a tube furnace capable of pre-hydriding cladding specimens and reorienting cladding hydrides and surface conditioning equipment. Mechanical testing (i.e., tensile, compression, and burst testing) will be performed on both pre-hydrided cladding and cladding with reoriented hydrides, and the results will be compared with those of as-manufactured cladding. Tensile and compression testing will be performed using a 5 kilo-pound load frame; burst testing will be performed on a purpose-built test system. Strain is measured with a digital image correlation (DIC) system. DIC is a real time optical measurement technique that utilizes high-definition imagery to measure object deformation. It is planned that tensile, compression, and burst testing of cladding with reoriented hydrides will begin this year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interaction of Water with Carbon Fiber Reinforced Polymer Laminates under Dynamic Loading Conditions

With the aim of simulating the real conditions during the navigation, in this framework, impact tests were performed by loading CFRP laminates immersed in the water from the front side. The specimens, made by vinyl ester matrix because of the lower moisture absorption compared to the other epoxy systems, are in the presence of the water to accurately simulate the incidental impact on the hull of the vessel, immersed or partially immersed, during the navigation. It can be caused by the ice in the Arctic Ocean, by a projectile due to a terroristic attack or by debris from an explosion. The results are compared with the ones obtained by loading the laminates in pure traditional impact tests in the air. The influence of the clamping device has been tested too. The exciting results obtained on carbon fiber laminates in the air (pure traditional impact tests), water-backed (with water on the back side) and waterfront (water only on the front side) conditions at room temperature are here reported and compared. They highlighted the critical role played by the complex fluid–structure interaction.

36 MATERIALS SCIENCE↗

SU-F-J-37: Commissioning a Six Degree of Freedom Couch

Purpose: The proper operation of a six degree of freedom couch (6DOFC) to position a patient for treatment requires that a number systems on the treatment unit work together correctly. Commissioning a 6DOFC requires not only the commissioning of each separate system but also commissioning the interactions between the systems. Methods: To commission a 6DOFC, we tested the resolvers that readout the linear and angular positions; the orthogonality of the axes of the laser positioning system, the imaging system, the gantry and the couch as well as their relationship to each other. An automated Winston-Lutz test was used verify the coincidence of the origins of the laser system, imaging system and treatment unit. The IsoCal phantom was used to verify the consistency of axes orientations between systems. The operation of the couch and imaging system was verified under simulated load conditions and an end to end test was performed to verify correct operation of the system. Results: The tests on the couch resolvers, orthogonality and coincidence of the axes of each system were successfully completed and showed excellent agreement. The automated Winston-Lutz test showed that the maximum displacement of the center of the radiation field with respect to the isocenter was <0.6 mm (radius) at isocenter. The analysis of the IsoCal phantom showed that the maximum variation of the radiation field with respect to known locations in the phantom was ∼0.9 mm for all the BBs in the phantom. Load tests showed maximum errors of 1 mm. Conclusion: We tested all system associated with the 6DOFC and found the uncertainty due to imaging was <.9mm and the uncertainty due to loading ∼1 mm, resulting in a total error of ∼1.4 mm.

60 APPLIED LIFE SCIENCES↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗