Systems and methods for randomized, packet-based power management of conditionally-controlled loads and bi-directional distributed energy storage systems

The present disclosure provides a distributed and anonymous approach to demand response of an electricity system. The approach conceptualizes energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Steam Dryer Segmentation and Packaging at Grand Gulf Nuclear Station - 13577

Entergy recently performed an Extended Power Up-rate (EPU) on their Grand Gulf Nuclear Station, near Port Gibson, Mississippi. To support the EPU, a new Steam Dryer Assembly was installed during the last refueling outage. Due to limited access into the containment, the large Replacement Steam Dryer (RSD) had to be brought into the containment in pieces and then final assembly was completed on the refueling floor before installation into the reactor. Likewise, the highly contaminated Original Steam Dryer (OSD) had to be segmented into manageable sections, loaded into specially designed shielded containers, and rigged out of containment where they will be safely stored until final disposal is accomplished at an acceptable waste repository. Westinghouse Nuclear Services was contracted by Entergy to segment, package and remove the OSD from containment. This work was performed on critical path during the most recent refueling outage. The segmentation was performed underwater to minimize radiation exposure to the workers. Special hydraulic saws were developed for the cutting operations based on Westinghouse designs previously used in Sweden to segment ABB Reactor Internals. The mechanical cutting method was selected because of its proven reliability and the minimal cutting debris that is generated by the process. Maintaining stability of the large OSD sections during cutting was accomplished using a custom built support stand that was installed into the Moisture Separator Pool after the Moisture Separator was installed back in the reactor vessel. The OSD was then moved from the Steam Dryer Pool to the Moisture Separator Pool for segmentation. This scenario resolved the logistical challenge of having two steam dryers and a moisture separator in containment simultaneously. A water filtration/vacuum unit was supplied to maintain water clarity during the cutting and handling operations and to collect the cutting chips. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗

Spinning Reserve from Hotel Air Conditioning Load - SHORT VERSION

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic load balancing of matrix-vector multiplications on roadrunner compute nodes

Hybrid architectures that combine general purpose processors with accelerators are being adopted in several large-scale systems such as the petaflop Roadrunner supercomputer at Los Alamos. In this system, dual-core Opteron host processors are tightly coupled with PowerXCell 8i processors within each compute node. In this kind of hybrid architecture, an accelerated mode of operation is typically used to offload performance hotspots in the computation to the accelerators. In this paper we explore the suitability of a variant of this acceleration mode in which the performance hotspots are actually shared between the host and the accelerators. To achieve this we have designed a new load balancing algorithm, which is optimized for the Roadrunner compute nodes, to dynamically distribute computation and associated data between the host and the accelerators at runtime. Results are presented using this approach for sparse and dense matrix-vector multiplications that show load-balancing can improve performance by up to 24% over solely using the accelerators.

97 MATHEMATICS AND COMPUTING↗

Parasitic load control system for exhaust temperature control

A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.

42 ENGINEERING↗

LDEXPT, an intelligent database system for the Composite Load Spectra project

The Composite Load Spectra project develops probabilistic models to simulate the probabilistic loads for selected components of a generic space propulsion system. Tremendous information such as engine load variables and their distributions is needed by the simulation program. An intelligent data base system was constructed and integrated with the probabilistic load simulation program to manage and maintain the knowledge base of the Composite Load Spectra project. The intelligent data base system takes care of the data retrieval and storage functions and has expert knowledge on engine load models and associated engine variables. The integration of the intelligent data base into the load simulation program achieves a smooth coupling between the numeric processing (load simulation calculation) and the symbolic processing (intelligent load information management).

Ho, H.↗

Total Thermal Management of Battery Electric Vehicles (BEVs)

The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

Chowdhury, Sourav↗

Description of the SSF PMAD DC testbed control system data acquisition function

The NASA LeRC in Cleveland, Ohio has completed the development and integration of a Power Management and Distribution (PMAD) DC Testbed. This testbed is a reduced scale representation of the end to end, sources to loads, Space Station Freedom Electrical Power System (SSF EPS). This unique facility is being used to demonstrate DC power generation and distribution, power management and control, and system operation techniques considered to be prime candidates for the Space Station Freedom. A key capability of the testbed is its ability to be configured to address system level issues in support of critical SSF program design milestones. Electrical power system control and operation issues like source control, source regulation, system fault protection, end-to-end system stability, health monitoring, resource allocation, and resource management are being evaluated in the testbed. The SSF EPS control functional allocation between on-board computers and ground based systems is evolving. Initially, ground based systems will perform the bulk of power system control and operation. The EPS control system is required to continuously monitor and determine the current state of the power system. The DC Testbed Control System consists of standard controllers arranged in a hierarchical and distributed architecture. These controllers provide all the monitoring and control functions for the DC Testbed Electrical Power System. Higher level controllers include the Power Management Controller, Load Management Controller, Operator Interface System, and a network of computer systems that perform some of the SSF Ground based Control Center Operation. The lower level controllers include Main Bus Switch Controllers and Photovoltaic Controllers. Power system status information is periodically provided to the higher level controllers to perform system control and operation. The data acquisition function of the control system is distributed among the various levels of the hierarchy. Data requirements are dictated by the control system algorithms being implemented at each level. A functional description of the various levels of the testbed control system architecture, the data acquisition function, and the status of its implementationis presented.

Baez, Anastacio N.↗

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling andfuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and abattery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC loadestimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Two-Level Model Predictive Control-Based Approach for Building Energy Management including Photovoltaics, Energy Storage, Solar Forecasting and Building Loads

This paper uses a two-level model predictive control-based approach for the coordinated control and energy management of an integrated system that includes photovoltaic (PV) generation, energy storage, and building loads. Novel features of the proposed local controller include (1) the ability to simultaneously manage building loads and energy storage to achieve different operational objectives such as energy efficiency, economic cost efficiency, demand response and grid optimization through the design of specific power trajectory tracking performance functionals, (2) an energy trim function that minimizes the impact of solar forecasting errors on system performance, and (3) the design of a state of charge controller that uses day-ahead forecast of solar power and building loads to intialize energy storage at the start of each day. The local controller is tested in simulation using an exemplary system with PV generation, energy storage and dispatchable building loads. Two sample days with different PV forecasts and multiple case scenarios are considered, and the performance of the algorithm in managing the real and reactive net building load trajectories and the ramp rate of PV injections into the utility network are evaluated. The simulations are based on actual forecasted and measured PV data, and the results show that the local controller meets the tracking requirements for real and reactive power within the operating constraints of the building.

14 SOLAR ENERGY↗

Multiplexer/Demultiplexer Loading Tool (MDMLT)

The purpose of the MDMLT is to improve the reliability and speed of loading multiplexers/demultiplexers (MDMs) in the Software Development and Integration Laboratory (SDIL) by automating the configuration management (CM) of the loads in the MDMs, automating the loading procedure, and providing the capability to load multiple or all MDMs concurrently. This loading may be accomplished in parallel, or single MDMs (remote). The MDMLT is a Web-based tool that is capable of loading the entire International Space Station (ISS) MDM configuration in parallel. It is able to load Flight Equivalent Units (FEUs), enhanced, standard, and prototype MDMs as well as both EEPROM (Electrically Erasable Programmable Read-Only Memory) and SSMMU (Solid State Mass Memory Unit) (MASS Memory). This software has extensive configuration management to track loading history, and the performance improvement means of loading the entire ISS MDM configuration of 49 MDMs in approximately 30 minutes, as opposed to 36 hours, which is what it took previously utilizing the flight method of S-Band uplink. The laptop version recently added to the MDMLT suite allows remote lab loading with the CM of information entered into a common database when it is reconnected to the network. This allows the program to reconfigure the test rigs quickly between shifts, allowing the lab to support a variety of onboard configurations during a single day, based on upcoming or current missions. The MDMLT Computer Software Configuration Item (CSCI) supports a Web-based command and control interface to the user. An interface to the SDIL File Transfer Protocol (FTP) server is supported to import Integrated Flight Loads (IFLs) and Internal Product Release Notes (IPRNs) into the database. An interface to the Monitor and Control System (MCS) is supported to control the power state, and to enable or disable the debug port of the MDMs to be loaded. Two direct interfaces to the MDM are supported: a serial interface (debug port) to receive MDM memory dump data and the calculated checksum, and the Small Computer System Interface (SCSI) to transfer load files to MDMs with hard disks. File transfer from the MDM Loading Tool to EEPROM within the MDM is performed via the MILSTD- 1553 bus, making use of the Real- Time Input/Output Processors (RTIOP) when using the rig-based MDMLT, and via a bus box when using the laptop MDMLT. The bus box is a cost-effective alternative to PC-1553 cards for the laptop. It is noted that this system can be modified and adapted to any avionic laboratory for spacecraft computer loading, ship avionics, or aircraft avionics where multiple configurations and strong configuration management of software/firmware loads are required.

Brewer, Lenox Allen↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

Hu, Rongxing↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Hierarchical Architecture for Transactive Wholesale-Retail Market Integration

Transactive control strategies for managing real-time energy consumption have been under study for a number of years. This work investigates a hierarchical control framework for such a system. This framework consist of two control layers to aggregate and reflect the flexibility of demand assets in the wholesale markets. Computation at each layer and communication across layers is designed to be minimal. The minimization of data exchange is done through demand curve approximation. To manage these two approximations, two intermediate layer dispatch strategies are compared: price-priority and quantity-priority. The price-priority dispatch results in significant differences between the wholesale cleared load and the actual retail load while the quantity-priority dispatch manages load much better at the cost of introducing uncertainty into the business cases of the intermediate layers.

Marinovici, Laurentiu D.↗