Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Stabilized Hyperfoam Modeling of the General Plastics EF4003 (3 PCF) Flexible Foam

Constitutive model parameterizations for the General Plastics EF4003 low density 3 pound per cubic foot are needed for design and qualification purposes in normal and abnormal mechanical simulations. The material is expected to be deformed in two ways: first during preloading, and second under impact conditions of the system (transient dynamic). All analyses are to be performed at room temperature. The goal is to provide the analysis community a robust constitutive model parameterization to represent the compression behavior of the EF4003 foam from small deformations up to massive compressive deformations when the foam is densifying. It is worth noting the EF4003 exhibits anisotropy in its stress-strain behavior between the rise and transverse directions (See figure 2.8c-d) as well as plateau behavior that is very likely to cause material stability issues, due to the buckling transition, (and has historically done so) when using Sandia’s current workhorse models for flexible foams, Hyperfoam and Flex Foam. A Stability-informed Hyperfoam parameterization procedure is developed and executed to calibrate a hyperfoam model for the EF4003 room temperature, transversely loaded data. A rise orientation parameterization was not attempted due to localization in the experiments.

36 MATERIALS SCIENCE↗

Interpretable Net Load Forecasting Using Smooth Multiperiodic Features

We consider the problem of forecasting net load over a horizon such as one day, using a trailing window of past net load values as well as date and time. We focus on three variations on this problem: point forecasts, marginal quantile forecasts, and generating conditional samples of the future value. We propose a method that relies on linear regression using some custom engineered time-based features to capture multiple periodicities, such as daily, weekly, and seasonal, and their interactions. Our proposed models are readily interpretable, and rely on efficient and reliable convex optimization [1] to fit. We illustrate our method on four years worth of hourly net load data, comparing predictions made with various subsets of the features.

Ogut, Mehmet G↗

TEAMER – Enhanced Flow Measurement for Aquantis Tidal Turbine Test

The AQ10 is a floating, two-bladed, passive yawing tidal turbine developed by Aquantis that has a 10-meterrotor diameter, 160 kW rating, and employs reliable off-the-shelf powertrain and power conversion hardware. Aquantis is planning on-water turbine power performance and loads (blade loading and thrust)testing, where the turbine will be pushed through still water up to 4 knots and placed in a ‘station keeping’ tow in a tidal race up to its rated speed. On-water testing will be conducted using vessels and floating platforms on the sea surface to improve ease of testing and reduce disturbance to the environment. In this TEAMER project, Pacific Northwest National Laboratory (PNNL) will conduct water velocity and turbulence measurements in front of the turbine during on-water testing using acoustic Doppler instrumentation. By measuring both the tidal current flowing past the turbine and the resulting electrical power output, test results will provide a power curve (power vs flow speed) for the turbine up to rated power. Measurements of turbulence and velocity shear in front of the rotor will also provide information to assess the structural response of the rotor blades. With this analysis, Aquantis can use the performance and loads data to validate Tidal Bladed and OpenFAST simulations of the measured operating conditions. Measuring the power performance of a prototype turbine is a valuable step to improving device development and conducting a complete power performance assessment to IEC/TS 62600-200 standards in the future.

16 TIDAL AND WAVE POWER↗

Benchmarking DAOS Filesystem on Aurora

We benchmark the DAOS filesystem on Argonne's Aurora supercomputer (127 nodes, 4,064 targets) using fio, IOR, mdtest, and IO500 to characterize I/O and metadata performance across the DFS API and DFuse+POSIX. Single-client fio shows POSIX bandwidth saturating at 1–2 MiB I/O sizes, with write-heavy workloads outperforming reads. Multi-node IOR shows DFS bandwidth scaling well up to ~32 tasks/node, with write latency growing faster than read latency. An 8-node IO500 evaluation shows DFS achieving ~5x higher bandwidth and ~190x higher IOPS than POSIX. Results indicate DAOS is well-suited to read-heavy workloads like AI training data loading, given appropriately sized transfers and concurrency.

George, Rebecca [College of William and Mary, Will↗

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Addressing GPU memory limitations for Graph Neural Networks in High-Energy Physics applications

Introduction Reconstructing low-level particle tracks in neutrino physics can address some of the most fundamental questions about the universe. However, processing petabytes of raw data using deep learning techniques poses a challenging problem in the field of High Energy Physics (HEP). In the Exa.TrkX Project, an illustrative HEP application, preprocessed simulation data is fed into a state-of-art Graph Neural Network (GNN) model, accelerated by GPUs. However, limited GPU memory often leads to Out-of-Memory (OOM) exceptions during training, due to the large size of models and datasets. This problem is exacerbated when deploying models on High-Performance Computing (HPC) systems designed for large-scale applications. Methods We observe a high workload imbalance issue during GNN model training caused by the irregular sizes of input graph samples in HEP datasets, contributing to OOM exceptions. We aim to scale GNNs on HPC systems, by prioritizing workload balance in graph inputs while maintaining model accuracy. Our paper introduces diverse balancing strategies aimed at decreasing the maximum GPU memory footprint and avoiding the OOM exception, across various datasets. Results Our experiments showcase memory reduction of up to 32.14% compared to the baseline. We also demonstrate the proposed strategies can avoid OOM in application. Additionally, we create a distributed multi-GPU implementation using these samplers to demonstrate the scalability of these techniques on the HEP dataset. Discussion By assessing the performance of these strategies as data loading samplers across multiple datasets, we can gauge their effectiveness in both single-GPU and distributed environments. Our experiments, conducted on datasets of varying sizes and across multiple GPUs, broaden the applicability of our work to various GNN applications that handle input datasets with irregular graph sizes.

Lee, Claire Songhyun↗

Modeling HIV-1 Within-Host Dynamics After Passive Infusion of the Broadly Neutralizing Antibody VRC01

VRC01 is a broadly neutralizing antibody that targets the CD4 binding site of HIV-1 gp120. Passive administration of VRC01 in humans has assessed the safety and the effect on plasma viremia of this monoclonal antibody (mAb) in a phase 1 clinical trial. After VRC01 infusion, the plasma viral load in most of the participants was reduced but had particular dynamics not observed during antiretroviral therapy. In this paper, we introduce different mathematical models to explain the observed dynamics and fit them to the plasma viral load data. Based on the fitting results we argue that a model containing reversible Ab binding to virions and clearance of virus-VRC01 complexes by a two-step process that includes (1) saturable capture followed by (2) internalization/degradation by phagocytes, best explains the data. This model predicts that VRC01 may enhance the clearance of Ab-virus complexes, explaining the initial viral decay observed immediately after antibody infusion in some participants. Because Ab-virus complexes are assumed to be unable to infect cells, i.e., contain neutralized virus, the model predicts a longer-term viral decay consistent with that observed in the VRC01 treated participants. By assuming a homogeneous viral population sensitive to VRC01, the model provides good fits to all of the participant data. However, the fits are improved by assuming that there were two populations of virus, one more susceptible to antibody-mediated neutralization than the other.

60 APPLIED LIFE SCIENCES↗

Testing Protocol Development for the Fracture Toughness of Parts Built with Big Area Additive Manufacturing

The mechanical testing of additively manufactured parts has largely relied on the existing standards developed for traditional manufacturing. While this approach leverages the investment made in current standards development, it inaccurately assumes that the mechanical response of additive manufacturing (AM) parts is identical to that of parts manufactured through traditional processes. When considering thermoplastic, material extrusion AM, the differences in response can be attributed to an AM part’s inherent inhomogeneity caused by porosity, interlayer zones, and surface texture. Additionally, the interlayer bonding of parts printed with large-scale AM is difficult to adequately assess, as much testing is performed such that stress is distributed across many layer interfaces; therefore, the lack of AM-specific standards to assess interlayer bonding is a significant research gap. To quantify interlayer bonding via fracture toughness, double cantilever beam (DCB) testing has been used for some AM materials, and DCB has been generally used for a variety of materials including metal, wood, and laminates. Mode I DCB testing was performed on thermoplastic matrix composites printed with Big Area Additive Manufacturing (BAAM). Of particular interest was the notch shape and deflection speed during testing. The results examine the differences when using two notch types and three deflection speeds. The testing method introduced by the following paper differentiates itself from the ones described in the standards used by modernizing the methodology. This was conducted with the introduction of Digital Image Correlation (DIC) to gather displacement and load data simultaneously without human intervention.

Polymer Science↗

Modified Multhopp lifting surface loading program

Computer program determines the longitudinal subsonic aerodynamic characteristics of composite wings. The program uses the basic theoretical method of Multhopp in predicting the loading data.

Lamar, J. E.↗

Electric contact phenomena in ultra clean and specifically contaminated systems.

Contact resistance has been used to characterize the processes of physical contact in metallic systems with ultra clean surfaces. The contact resistance versus load curves of iron and two cobalt alloys were used to demonstrate the existence of surface work hardening and interfacial creep during contact as well as the fracture characteristics of an interfacial junction as the load is removed. The presence of an adsorbed film of hydrogen or hydrogen ions on iron completely changes the contact process. A comparison of the contact resistance versus load data for ultra pure iron, an iron-cobalt alloy and a cobalt molybdenum-chromium was used to illustrate the effect of substrate mechanical properties on static adhesion and the ability to convert these data for the estimation of the dynamic coefficient of friction under the particular experimental conditions.

Keller, D. V., Jr.↗

Electric contact phenomena in ultra clean and specifically contaminated systems.

Contact resistance has been used to characterize the processes of physical contact in metallic systems with ultraclean surfaces. The contact resistance versus load curves of iron and two cobalt alloys were used to demonstrate the existence of surface work hardening and interfacial creep during contact as well as the fracture characteristics of an interfacial junction as the load is removed. The presence of an adsorbed film of hydrogen or hydrogen ions on iron completely changes the contact process. A comparison of the contact resistance versus load data for ultrapure iron, and iron-cobalt alloy, and a cobalt molybdenum-chromium was used to illustrate the effect of substrate mechanical properties on static adhesion and the ability to convert these data for the estimation of the dynamic coefficient of friction under the particular experimental conditions.

Keller, D. V., Jr.↗

Pressure loads and aerodynamic force information for the -89A space shuttle orbiter configuration, volume 2

Experimental aerodynamic investigations were conducted in a low speed wind tunnel on an 0.0405 scale representation of the 89A light weight Space Shuttle Orbiter to obtain pressure loads data in the presence of the ground for orbiter structural strength analysis. The model and the facility are described, and data reduction is outlined. Tables are included for data set/run number collation, data set/component collation, model component description, and pressure tap locations by series number. Tabulated force and pressure source data are presented.

Mennell, R. C.↗

Results of tests in the MSFC 14 x 14 inch trisonic wind tunnel on a .004 scale model of the Rockwell International Space Shuttle Vehicle 3, (integrated configuration)

Experimental aerodynamic investigations were conducted during mid-July, 1973 on a .004 scale model of the Rockwell International integrated configuration Space Shuttle Vehicle 3. The purpose of the tests was three fold: (1) to determine the static stability characteristics of the integrated vehicle, utilizing the Vehicle 3 orbiter configuration; (2) to determine the effect of interstage structure and tank external fuel lines on the integrated vehicle aerodynamic characteristics; (3) to determine the effects of the aft interstage structure on orbiter aerodynamic loads. Data were recorded on the integrated vehicle (test no. 579) at angles of attack and sideslip ranging from -10 deg to 10 deg over a Mach number schedule from 0.6 to 4.96. Data were obtained on the orbiter alone in the presence of the external tank with SRB attached (test no. 580) at angles of attack from -10 deg to 10 deg over a Mach number range from .6 to 1.96. Plotted data are presented in the body axis system.

Allen, E. C.↗

Results of investigation on an 0.015 scale configuration 140A/B space shuttle vehicle orbiter reaction control system plume-impingement model 36-0 in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel (0A83)

The results of aerodynamic pressure and wingroot bending-moment testing conducted on a 0.015-scale Configuration 140A/B space shuttle vehicle orbiter reaction control system plume-impingement model are documented. The model was investigated at nominal Mach numbers of 5.3, 7.3, and 10.3, at unit Reynolds numbers of 4,200,000 ft, 7,300,000 ft, and 1,700,000 ft. Model attitude was varied in angle of attack from 18 deg to 38 deg at angles of sideslip from -2 deg to +2 deg. The test program was conducted to establish and reaffirm incremental orbiter pressure-profile and structural-loads data due to operation of the aftbody reaction control system pitch-down engines.

Nicholas, M. E.↗