Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-Elastic Neutrino Interactions in the SAND Detector of DUNE

The System for on-Axis Neutrino Detection (SAND) is one of the three components of the DUNE Near Detector Complex. Its main goals are monitoring of the beam, precision measurements of neutrino cross-sections and short-baseline neutrino physics. The SAND detector is composed of a 0.6 T superconducting magnet, an electromagnetic calorimeter, a liquid argon active target (GRAIN) and a modular low-density target system. The GRAIN subdetector has been designed to allow the reconstruction of neutrino interactions in Argon using only the scintillation light, by implementing an innovative imaging system. In this poster, the performances of SAND are presented focusing on its capability to reconstruct νμ+Ar→μ−+p events using the information provided by the calorimeter, the tracking system and GRAIN.

Ingratta, Gianfranco↗

A study of events with photoelectric emission in the DarkSide-50 liquid argon Time Projection Chamber

Finding unequivocal evidence of dark matter interactions in a particle detector is a major goal of research in physics. Liquid argon time projection chambers offer a path to probe Weakly Interacting Massive Particles scattering cross sections on nuclei down to the so-called neutrino floor, in a mass range from a few GeV to hundreds of TeV. Based on the successful operation of the DarkSide-50 detector at LNGS, a new and more sensitive experiment, DarkSide-20k, has been designed and is now under construction. A thorough understanding of the DarkSide-50 detector response and, therefore, of all types of events observed in the detector, is essential for the optimal design of the new experiment. In this article, we report on a specific set of events, namely, standard two-pulse scintillation–ionization signals with a third small amplitude pulse, occurring within the 440 μ s data acquisition window of standard events. Some of these events are due to the photoionization of the TPC cathode. We compare our results with those published by collaborations using liquid xenon time projection chambers, which observed a similar phenomenon, and, in particular, with a recent paper by the LUX Collaboration (D.S. Akerib et al. Phys.Rev.D 102, 092004 (2020)) From the measured rate of these events, we estimate for the first time the quantum efficiency of the tetraphenyl butadiene deposited on the DarkSide-50 cathode at wavelengths of around 128 nm, in liquid argon. Also, both experiments observe events likely related to the photoionization of impurities in the liquid. The probability of photoelectron emission per unit length turns out to be an order of magnitude lower in DarkSide-50 than in LUX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Overview of Collaborative Research Between UNICAMP in Brazil and Fermilab in Cryogenics

The Long-Baseline Neutrino Facility (LBNF) situated at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, serves as the host for the Deep Underground Neutrino Experiment (DUNE), employing cryostats with nearly 70,000 metric tons of high purity liquid argon (LAr). The integrity of LAr quality is pivotal in determining the electron lifetime within DUNE, directly impacting its signal-to-noise ratio. Specifically, Far Detector 1 (FD-1) in cryostat 1 requires an electron lifetime over 3 ms within its 3.5 m drift, corresponding to less than 100 parts-per-trillion (ppt) Oxygen equivalent contamination. Far Detector 2 (FD-2) in cryostat 2 demands over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen equivalent contamination. Nitrogen (N2) absorption of LAr scintillation light, known as quenching, necessitates N2 contamination in LAr to remain below 1 ppm to minimize photon loss and enhance energy reconstruction. Studies indicate that at 1 ppm N2, approximately 20% of scintillation light is lost, highlighting the importance of minimizing N2 contamination. Brazil State University of Campinas's (UNICAMP) contribution to LBNF focuses on developing argon purification and regeneration for DUNE FD-1 and FD-2. To that effect, they constructed a test facility to perform studies on LAr purification at a smaller scale, the Purification Liquid Argon Cryostat (PuLArC) with approximately 90 liters of LAr. One of the filtration materials was considered and tested Li-FAU molecular sieve. Value engineering on argon purification media was conducted, leading to the identification of Li-FAU zeolite's ability to effectively capture N2 impurities during LAr circulation. Testing at UNICAMP's PuLArC facility demonstrated that 1 kg of Li-FAU is capable of reducing N2 contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours of circulation. In October 2023, testing at the Iceberg cryostat in Fermilab's Noble Liquid Test Facility (NLTF), with approximately 2,625 liters of LAr, confirmed the efficacy of 3 kg of Li-FAU in reducing N2 contamination from ~ 5 ppm of injected N2 down to less than 1 ppm over 96-hour cycles, showcasing its potential for larger-scale LAr cryostats. Further tests are planned to validate Li-FAU's use as a possible alternative to Molecular Sieve 4A in LBNF-DUNE and related liquid argon experiments. This contribution will describe how the research was performed and present the test setups and results in detail. This advancement not only has the potential to enhance DUNE's precision but also to elevate liquid argon experiments globally, showcasing the power of international scientific collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the ICARUS Trigger System at the Booster and NuMI Neutrino Beams †

The ICARUS-T600 liquid argon time projection chamber detector takes data at a shallow depth as the far detector of the Short Baseline Neutrino program at Fermilab, searching for sterile neutrinos with the Booster and Main Injector neutrino beams. The ICARUS trigger system exploits the temporal coincidence of the beams with scintillation light signals detected by 360 photo-multiplier tubes in limited TPC regions. The trigger efficiency measurement leverages cosmic rays collected without any scintillation light requirement, with timing from an external cosmic ray tagger system. The efficiency measured with stopping muons roughly saturates at ∼300 MeV, covering most of the expected energy range of charged-current neutrino interactions. For the latest ICARUS physics runs, special “adder” boards performing the analog sum of light signals were introduced as a complementary trigger to possibly recover low-energy neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Light Yield Calibration in MicroBooNE

The MicroBooNE detector is a Liquid Argon Time Projection Chamber (LArTPC) located along the Booster Neutrino Beam (BNB) at Fermilab. Its primary physics goal is to contribute to addressing the elusive short-baseline MiniBooNE low energy excess. MicroBooNE records and utilises both the ionisation charge and scintillation light produced inside the TPC to select and reconstruct neutrino interactions. The scintillation light collected using a plane of PhotoMultiplier Tubes (PMTs) is also used for accurate event timing and cosmic muon rejection with the latter being an important background for detectors, such as MicroBooNE, located on the surface. A good understanding of light modeling and its related systematic uncertainties is crucial to evaluate their impact on physics analyses. The experience acquired from MicroBooNE regarding how the stability of the scintillation light behaves and evolves during the 5 years of the primary physics run will be discussed as well as the calibration method used. This experience will help with understanding the physics of scintillation light in LArTPCs for the future long-running Short-Baseline Neutrino (SBN) and Deep Underground Neutrino Experiment (DUNE) programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Concept for Kilotonne Scale Liquid Argon Time Projection Chambers

We develop a novel Time Projection Chamber (TPC) concept suitable for deployment in kilotonne-scale detectors, with a charge-readout system free from reconstruction ambiguities, and a robust TPC design that reduces high-voltage risks while increasing the coverage of the light-collection system and maximizing the active volume. This novel concept could be used as a far detector module in the Deep Underground Neutrino Experiment (DUNE). For the charge-readout system, we used the charge-collection pixels and associated application-specific integrated circuits currently being developed for the liquid argon (LAr) component of the DUNE Near Detector design, ArgonCube. In addition, we divided the TPC into a number of shorter drift volumes, reducing the total voltage used to drift the ionization electrons, and minimizing the stored energy per TPC. Segmenting the TPC also contains scintillation light, allowing for precise trigger localization and a more expansive light-readout system. Furthermore, the design opens the possibility of replacing or upgrading components. These augmentations could substantially improve the reliability and the sensitivity, particularly for low-energy signals, in comparison to traditional monolithic LArTPCs with projective-wire charge readouts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

FLArE up dark sectors with EM form factors at the LHC forward physics facility

Despite being mostly secluded, dark sector particles may feebly interact with photons via a small mass-dimension 4 millicharge, a mass-dimension 5 magnetic and electric dipole moment, or a mass-dimension 6 anapole moment and charge radius. If sufficiently light, the LHC may produce an intense and collimated beam of these particles in the far forward direction. We study the prospects of searching for such dark sector particles with electromagnetic form factors via their electron scattering signature in the Forward Liquid Argon Experiment (FLArE) at the Forward Physics Facility (FPF). We find that FLArE can provide new probes of sub-GeV dark particles with dipole moments and strong sensitivities for millicharged particles in the 100 MeV to 100 GeV region. This complements other search strategies using scintillation signatures or dark matter direct detection and allows for probing strongly interacting dark matter motivated by the EDGES anomaly. Along with the FORMOSA detector, this leads to a very versatile and leading experimental program in the search for millicharged particles in the FPF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MIP dQ/dx Calibration in DUNE ND-LAr Prototypes with Pixelated Charge Readout

The Deep Underground Neutrino Experiment (DUNE) will be a next-generation long baseline neutrino oscillation experiment that will employ LArTPC technology in a near detector placed at Fermilab and a far detector at the Sanford Underground Research Facility, at a baseline of 1300 km. The DUNE Liquid Argon Near Detector (ND-LAr) design takes into account the high neutrino intensity expected from the beam at the Long-Baseline Neutrino Facility (LBNF): 35 modules, each containing two optically separated time projection chambers, are instrumented with a pixel-based, true 3D charge readout alongside scintillation light traps to disentangle the O(100) interactions expected per 10us beam spill. A robust prototyping program supports ND-LAr’s design: the 2x2 Demonstrator consists of four scaled-down ND-LAr modules exposed to the NuMI beam at Fermilab, and the Full Scale Demonstrator (FSD) is a single ND-LAr module tested with cosmic rays at the University of Bern. We present here an analysis of minimum ionizing particle (MIP) tracks selected from 2x2 beam data and FSD cosmic ray data used to benchmark the pixel-based charge readout simulation and calibration in both detectors, with the ultimate goal of validating the design of DUNE ND-LAr as well as informing future calibration methods. This poster will showcase the dependence of the charge response on track inclination as well as a per-pixel dQ/dX extraction.

Mandujano, Roberto [UC, Irvine]↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗