Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Sharp, high numerical aperture (NA), nanoimprinted bare pyramid probe for optical mapping

The ability to correlate optical hyperspectral mapping and high resolution topographic imaging is critically important to gain deep insight into the structure–function relationship of nanomaterial systems. Scanning near-field optical microscopy can achieve this goal, but at the cost of significant effort in probe fabrication and experimental expertise. To overcome these two limitations, we have developed a low-cost and high-throughput nanoimprinting technique to integrate a sharp pyramid structure on the end facet of a single-mode fiber that can be scanned with a simple tuning-fork technique. The nanoimprinted pyramid has two main features: (1) a large taper angle (~70°), which determines the far-field confinement at the tip, resulting in a spatial resolution of 275 nm, an effective numerical aperture of 1.06, and (2) a sharp apex with a radius of curvature of ~20 nm, which enables high resolution topographic imaging. Optical performance is demonstrated through evanescent field distribution mapping of a plasmonic nanogroove sample, followed by hyperspectral photoluminescence mapping of nanocrystals using a fiber-in-fiber-out light coupling mode. Through comparative photoluminescence mapping on 2D monolayers, we also show a threefold improvement in spatial resolution over chemically etched fibers. These results show that the bare nanoimprinted near-field probes provide simple access to spectromicroscopy correlated with high resolution topographic mapping and have the potential to advance reproducible fiber-tip-based scanning near-field microscopy.

47 OTHER INSTRUMENTATION↗

Multiple object spectroscopy - The Medusa spectrograph

An instrument has been built to obtain simultaneous spectra of many objects in the field of view of the Steward 90 inch (2.29 m) telescope. Short lengths of fused silica fiber 300 microns in diameter are used to bring the light from galaxy images at the Cassegrain focus into a line along the spectrograph slit. From a single exposure of the cluster Abell 1904, which has a redshift of 20,000 km/s, the redshifts of 26 individual galaxies were determined, each with a precision of 100 km/s. The present device, while already giving a sixfold reduction in the mean telescope time per galaxy, has significant light losses because it is not ideally matched to the telescope. An instrument being designed for the prime focus will transmit light from each object as efficiently as a conventional spectrograph.

Hill, J. M.↗

Fourier-Transform Infrared Spectrometer

Fourier-transform spectrometer provides approximately hundredfold increase in luminosity at detector plane over that achievable with older instruments of this type. Used to analyze such weak sources as pollutants and other low-concentration substances in atmosphere. Interferometer creates fringe patterns on two distinct arrays of light detectors, which observe different wavelength bands. Objective lens focuses scene on image plane, which contains optical chopper. To make instrument less susceptible to variations in scene under observation, field and detector lenses focus entrance aperture, rather that image, onto detector array.

Schindler, R. A.↗

DISCO - A Wide Field Heliospheric Imager

DISCO (Direct Imaging of the Solar Corona) is a concept for a compact, side-looking heliospheric imager that captures a wide field of view with a single camera and detector. The first optical element of DISCO is a convex reflector that tends to direct stray light away from the lenses and detector. The angular resolution of the system varies over the field of view and is higher at low elongation angeles where it is most needed to resolve the structure of coronal mass ejections and corotating interaction regions.

Rabin, Douglas↗

Ground-Based X-Ray Calibration of the Astro-H/Hitomi Soft X-Ray Telescopes

We present the summary of the on-ground calibration of two soft x-ray telescopes (SXT-I and SXT-S), developed by NASA's Goddard Space Flight Center (GSFC), onboard Astro-H/Hitomi. After the initial x-ray measurements with a diverging beam at the GSFC 100-meter beamline, we performed the full calibration of the x-ray performance, using the 30-meter x-ray beamline facility at the Institute of Space and Astronautical Science of Japan Aerospace Exploration Agency in Japan. We adopted a raster scan method with a narrow x-ray pencil beam with a divergence of approximately 15 arc secs. The on-axis effective area (EA), half-power diameter, and vignetting function were measured at several energies between 1.5 and 17.5 kiloelectronvolts. The detailed results appear in tables and figures in this paper. We measured and evaluated the performance of the SXT-S and the SXT-I with regard to the detector-limited field-of-view and the pixel size of the paired flight detector, i.e., SXS and the SXI, respectively. The primary items measured are the EA, image quality, and stray light for on-axis and off-axis sources. The accurate measurement of these parameters is vital to make the precise response function of the ASTRO-H SXTs. This paper presents the definitive results of the ground-based calibration of the ASTRO-H SXTs.

Iizuka, Ryo↗

Super‐Resolution Lifetime Imaging of Single Molecules Near Gold Bowtie Nanoparticles

Interactions between light and matter serve as the basis of many technologies, but the quality of these devices is inherently limited by the optical properties of their constituents. Plasmonic nanoparticles are a highly versatile and tunable platform for the enhancement of such optical properties. However, the near-field nature of these effects has made thorough study and understanding of these mechanisms difficult. In this work, we introduce a fully confocal technique combining photoswitching super-resolution microscopy with fluorescence lifetime imaging microscopy to study single-molecule decay rate enhancement. We demonstrate that the technique combines a spatial resolution better than 20 nm, and a 16 ps temporal resolution. Simultaneously, an autocorrelation measurement is also performed to confirm that the data indeed originates from single molecules. This work provides insight into the various mechanisms of plasmon-enhanced emission, and allows the study of the correlation between emission intensity and lifetime enhancement. This complicated relationship is shown to be dependent upon the relative influence of various radiative and nonradiative decay pathways. Here, we provide a platform for further study of emission mislocalization, the position-dependent prominence of different decay pathways, and the direct super-resolved measurement of the local density of states.

36 MATERIALS SCIENCE↗

Tracking the Momentum Flux of a CME and Quantifying Its Influence on Geomagnetically Induced Currents at Earth

We investigate a coronal mass ejection (CME) propagating toward Earth on 29 March 2011. This event is specifically chosen for its predominately northward directed magnetic field, so that the influence from the momentum flux onto Earth can be isolated. We focus our study on understanding how a small Earth-directed segment propagates. Mass images are created from the white-light cameras onboard STEREO which are also converted into mass height-time maps (mass J-maps). The mass tracks on these J-maps correspond to the sheath region between the CME and its associated shockfront as detected by in situ measurements at L1. A time series of mass measurements from the STEREOCOR-2A instrument is made along the Earth propagation direction. Qualitatively, this mass time series shows a remarkable resemblance to the L1 in situ density series. The in situ measurements are used as inputs into a three-dimensional (3-D) magnetospheric space weather simulation from the Community Coordinated Modeling Center. These simulations display a sudden compression of the magnetosphere from the large momentum flux at the leading edge of the CME, and predictions are made for the time derivative of the magnetic field (dBdt) on the ground. The predicted dBdt values were then compared with the observations from specific equatorially located ground stations and showed notable similarity. This study of the momentum of a CME from the Sun down to its influence on magnetic ground stations on Earth is presented as a preliminary proof of concept, such that future attempts may try to use remote sensing to create density and velocity time series as inputs to magnetospheric simulations.

time series analysis↗

Imaging Photonic Resonances within an All‐Dielectric Metasurface via Photoelectron Emission Microscopy

Dielectric metasurfaces, through volume‐type photonic resonances, enable precise control of light‐matter interactions for applications including imaging, holography, and sensing. The application space of dielectric metasurfaces has extended from infrared to visible wavelengths by incorporating high refractive index materials, such as titanium dioxide (TiO 2 ). Understanding the fundamental and fabrication limits for these applications requires metrology with nanoscale resolution, sensitivity to electromagnetic fields within the meta‐atom volume, and far‐field excitation. In this work, photoelectron emission microscopy (PEEM) is used to image field distributions of photonic resonances in a TiO 2 metasurface excited with far‐field, visible‐wavelength illumination. The local volumetric field variations within the meta‐atoms are analyzed as a function of illumination angle and polarization by comparing photoelectron images to finite‐difference time‐domain simulations. This study determines the inelastic mean free path of very low‐energy (<1 eV) photoelectrons to be 35 ± 10 nm, which is comparable to the meta‐atom height thereby highlighting PEEM sensitivity to resonances within the volume. Additionally, the simulations reveal high sensitivity of PEEM images to an in‐plane component of the illumination k ‐vector. These results demonstrate that photoelectron imaging with subwavelength resolution offers unique advantages for examining light‐matter interactions in volume‐type (as opposed to surface) photonic modes within dielectric nanophotonic structures.

electron inelastic mean free path↗

Image Deconvolution and Point-spread Function Reconstruction with STARRED: A Wavelet-based Two-channel Method Optimized for Light-curve Extraction

We present starred, a point-spread function (PSF) reconstruction, two-channel deconvolution, and light-curve extraction method designed for high-precision photometric measurements in imaging time series. An improved resolution of the data is targeted rather than an infinite one, thereby minimizing deconvolution artifacts. In addition, starred performs a joint deconvolution of all available data, accounting for epoch-to-epoch variations of the PSF and decomposing the resulting deconvolved image into a point source and an extended source channel. The output is a high-signal-to-noise-ratio, high-resolution frame combining all data and the photometry of all point sources in the field of view as a function of time. Of note, starred also provides exquisite PSF models for each data frame. We showcase three applications of starred in the context of the imminent LSST survey and of JWST imaging: (i) the extraction of supernovae light curves and the scene representation of their host galaxy; (ii) the extraction of lensed quasar light curves for time-delay cosmography; and (iii) the measurement of the spectral energy distribution of globular clusters in the "Sparkler," a galaxy at redshift z = 1.378 strongly lensed by the galaxy cluster SMACS J0723.3-7327. starred is implemented in jax, leveraging automatic differentiation and graphics processing unit acceleration. This enables the rapid processing of large time-domain data sets, positioning the method as a powerful tool for extracting light curves from the multitude of lensed or unlensed variable and transient objects in the Rubin-LSST data, even when blended with intervening objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid simulations of hyperspectral near-field images of three-dimensional heterogeneous surfaces – part II

The modeling of the near-field interaction in the scattering-type scanning near-field optical microscope (s-SNOM) is rapidly advancing, although an accurate yet versatile modeling framework that can be easily adapted to various complex situations is still lacking. In this work, we propose a time-efficient numerical scheme in the quasi-electrostatic limit to capture the tip-sample interaction in the near field. This method considers an extended tip geometry, which is a significant advantage compared to the previously reported method based on the point-dipole approximation. Using this formalism, we investigate, among others, nontrivial questions such as uniaxial and biaxial anisotropy in the near-field interaction, the relationship between various experimental parameters (e.g. tip radius, tapping amplitude, etc.), and the tip-dependent spatial resolution. The demonstrated method further sheds light on the understanding of the contrast mechanism in s-SNOM imaging and spectroscopy, while also representing a valuable platform for future quantitative analysis of the experimental observations.

Chen, Xinzhong (ORCID:0000000261033848)↗

Particle Imaging Velocimetry Used in a Transonic Compressor Facility

Particle Imaging Velocimetry (PIV) is an optical technique whereby a pulsed laser sheet is used to illuminate particles entrained in a fluid across an extended planar cross section of a flow field. Electronic recording of the particle positions at two closely timed laser pulses permits the computation of the flow velocity. PIV captures the instantaneous flow field, permitting the study of unsteady flow phenomena. Mean flow statistics can be computed by acquiring several hundred images and averaging the results. The first-ever successful application of PIV to acquire measurements in a high-speed rotating turbomachinery blade row was completed in NASA Lewis Research Center's W-8 Single Stage Axial Compressor Facility. Measurements were acquired in a 20-in.-diameter transonic compressor rotor operating at 17,188 rpm. A custom-designed light-sheet generating probe was used to insert the high-energy, pulsed light-sheet illumination required for recording the unblurred images of particles entrained in the fluid. Measurements of the shock wave formed within the rotor blade passage and of unsteady structures within the blade wakes were acquired. These measurements provide insight into unsteady spatial structures in the flow field which cannot be measured with the more conventional laser anemometry technique. The PIV technique provides both instantaneous and average velocity data in a transonic compressor in an order of magnitude less time than required for other conventional optical diagnostic techniques.

Wernet, Mark P.↗

Flux Cube Reconstruction from Slitless Spectroscopy

Slitless spectroscopy enables efficient, large-area surveys without target preselection, yet it faces challenges from source blending, higher noise, and lost spatial–spectral information. We present an advanced, nonparametric, data-driven algorithm that leverages multiple dispersion angles to reconstruct three-dimensional flux distributions, providing low-resolution integral field unit capabilities from slitless data. By treating each pixel as an independent element, our method naturally handles source confusion without requiring prior assumptions regarding redshifts, templates, or model libraries. We validate the algorithm using simulated Roman Space Telescope wide-field slitless spectroscopy images that are equivalent to what is expected from the High-Latitude Time-Domain Survey. First, we demonstrate that a host-galaxy model reconstructed from multiple dispersion angles can be used to accurately subtract host light from a transient, recovering a Type Ia supernova spectrum with minimal bias. Second, we showcase a high-fidelity flux-cube reconstruction of a complex galaxy, successfully measuring the redshift and recovering continuum, emission, and absorption features. This approach highlights the potential of multi-dispersion-angle slitless data to provide spatially resolved spectral information in a nonparametric way, which is traditionally accessible only with integral field spectroscopy, opening a new window into large, unbiased, and spatially resolved studies of galaxy evolution.

Griggio, M. [Space Telescope Science Institute, Ba↗

A review of quantum imaging methods and enabling technologies

The field of quantum imaging has recently seen an explosion of new methods and techniques. At the heart of most quantum imaging approaches are three enabling technologies: the source of the quantum light, the detectors that turn sensing into imaging, and the method by which the quantum nature of light is leveraged to improve the desired measurement. This review addresses the dominant and emerging technologies in each of these components as well as details concerning the implementations of various quantum imaging methods.

36 MATERIALS SCIENCE↗

Spin Squeezing by Rydberg Dressing in an Array of Atomic Ensembles

Here, we report on the creation of an array of spin-squeezed ensembles of cesium atoms via Rydberg dressing, a technique that offers optical control over local interactions between neutral atoms. We optimize the coherence of the interactions by a stroboscopic dressing sequence that suppresses super-Poissonian loss. We thereby prepare squeezed states of N = 200 atoms with a metrological squeezing parameter ξ 2 = 0.77⁢(9) quantifying the reduction in phase variance below the standard quantum limit. We realize metrological gain across three spatially separated ensembles in parallel, with the strength of squeezing controlled by the local intensity of the dressing light. Our method can be applied to enhance the precision of tests of fundamental physics based on arrays of atomic clocks and to enable quantum-enhanced imaging of electromagnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

Response time to colored stimuli in the full visual field

Peripheral visual response time was measured in seven dark adapted subjects to the onset of small (45' arc diam), brief (50 msec), colored (blue, yellow, green, red) and white stimuli imaged at 72 locations within their binocular field of view. The blue, yellow, and green stimuli were matched for brightness at about 2.6 sub log 10 units above their absolute light threshold, and they appeared at an unexpected time and location. These data were obtained to provide response time and no-response data for use in various design disciplines involving instrument panel layout. The results indicated that the retina possesses relatively concentric regions within each of which mean response time can be expected to be of approximately the same duration. These regions are centered near the fovea and extend farther horizontally than vertically. Mean foveal response time was fastest for yellow and slowest for blue. Three and one-half percent of the total 56,410 trials presented resulted in no-responses. Regardless of stimulus color, the lowest percentage of no-responses occurred within 30 deg arc from the fovea and the highest within 40 deg to 80 deg arc below the fovea.

Haines, R. F.↗

Concentration Measurements in a Cold Flow Model Annular Combustor Using Laser Induced Fluorescence

A nonintrusive concentration measurement method is developed for determining the concentration distribution in a complex flow field. The measurement method consists of marking a liquid flow with a water soluble fluorescent dye. The dye is excited by a two dimensional sheet of laser light. The fluorescent intensity is shown to be proportional to the relative concentration level. The fluorescent field is recorded on a video cassette recorder through a video camera. The recorded images are analyzed with image processing hardware and software to obtain intensity levels. Mean and root mean square (rms) values are calculated from these intensity levels. The method is tested on a single round turbulent jet because previous concentration measurements have been made on this configuration by other investigators. The previous results were used to comparison to qualify the current method. These comparisons showed that this method provides satisfactory results. 'Me concentration measurement system was used to measure the concentrations in the complex flow field of a model gas turbine annular combustor. The model annular combustor consists of opposing primary jets and an annular jet which discharges perpendicular to the primary jets. The mixing between the different jet flows can be visualized from the calculated mean and rms profiles. Concentration field visualization images obtained from the processing provide further qualitative information about the flow field.

Morgan, Douglas C.↗