Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kapton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Effect of initial delamination on Mode 1 and Mode 2 interlaminar fracture toughness and fatigue fracture threshold

Static and fatigue double-cantilever beam (DCB) and end-notch flexure (ENF) tests were conducted to determine the effect of the simulated initial delamination in interlaminar fracture toughness, G(sub c), and fatigue fracture threshold, G(sub th). Unidirectional, 24-ply specimens of S2/SP250 glass/epoxy were tested using Kapton inserts of four different thickness - 13, 25, 75, and 130 microns, at the midplane at one end, or with tension or shear precracks, to simulate an initial delamination. To determine G(sub c), the fatigue fracture threshold below which no delamination growth would occur in less than 1 x 10(exp 6) cycles, fatigue tests were conducted by cyclically loading specimens until delamination growth was detected. Consistent values of model 1 fracture toughness, G(sub Ic), were measured from DCB specimens with inserts of thickness 75 microns or thinner, or with shear precracks. The fatigue DCB tests gave similar values of G(sub Ith) for the 13, 25, and 75 microns specimens. Results for the shear precracked specimens were significantly lower that for specimens without precracks. Results for both the static and fatigue ENF tests showed that measured G(IIc) and G(IIth) values decreased with decreasing insert thickness, so that no limiting thickness could be determined. Results for specimens with inserts of 75 microns or thicker were significantly higher than the results for precracked specimens or specimens with 13 or 25 microns inserts.

Murri, Gretchen Bostaph↗

Low Earth orbital atomic oxygen micrometeoroid, and debris interactions with photovoltaic arrays

Polyimide Kapton solar array blankets can be protected from atomic oxygen in low earth orbit if SiO sub x thin film coatings are applied to their surfaces. The useful lifetime of a blanket protected in this manner strongly depends on the number and size of defects in the protective coatings. Atomic oxygen degradation is dominated by undercutting at defects in protective coatings caused by substrate roughness and processing rather than micrometeoroid or debris impacts. Recent findings from the Long Duration Exposure Facility (LDEF) and ground based studies show that interactions between atomic oxygen and silicones may cause grazing and contamination problems which may lead to solar array degradation.

Banks, Bruce A.↗

Reusable cryogenic foam insulation for advanced aerospace vehicles

Future high-speed aircraft and aerospace vehicles using cryogenic propellants will require an advanced reusable insulation system for the propellant tank structure. This cryogenic insulation system must be lightweight, structurally and thermally efficient, and capable of multiple reuse without cracking or degraded performance. This paper presents recent progress in the development of a reusable cryogenic foam insulation system having a maximum service temperature of 400 F. The system consists of preshaped, precut blocks of rigid polymethacrylimide foam insulation, wrapped with a high-temperature Kapton and aluminum foil vapor barrier which is adhesively bonded to the propellant tank wall.

Mcauliffe, Patrick S.↗

Mechanisms of atomic oxygen induced materials degradation

This paper includes discussions of mechanisms by which atomic oxygen may attack materials being flown in low earth orbit (LEO), suggestions for development of materials intrinsically resistant to the harsh LEO environment, and results of an Arrhenius fit to mass loss of Kapton under exposure to thermal atomic oxygen in a laboratory environment. Oxygen atoms are powerful oxidizing agents which can rapidly degrade many types of polymeric materials. The process details depend upon the specific material, its detailed bonding, the thermodynamic stability of potential products, temperature, and particle dynamics. With regard to spacecraft, many effects associated with atomic oxygen may be explained simply by ordinary thermal oxidation processes and by the fact that the oxygen has a preferred direction of impingement.

Pippin, H. G.↗

Undercutting of defects in thin film protective coatings on polymer surfaces exposed to atomic oxygen

Protection for polymeric surfaces is needed to make them durable in the low earth orbital environment. Thin film coatings of oxides such as SiO2 are viable candidates to provide this protection, but concern has been voiced over the ability of these coatings to protect when defects are present in the coating due to surface anomalies. When a defected coating protecting a polymer substrate is exposed to atomic oxygen, the defect provides a pathway to the underlying polymer allowing oxidation and subsequent undercutting to occur. Defect undercutting was studied for sputter deposited coatings of SiO2 on polyimide Kapton. Preliminary results indicate that undercutting may be limited as long as the coating remains intact with the substrate. Therefore, coatings may not need to be defect free to give protection to the underlying surface.

Rutledge, Sharon K.↗

Atomic oxygen resistant protective coatings for the Hubble Space Telescope solar array in low earth orbit

The Hubble Space Telescope back-up solar array (BSFR-ATOX) was designed with atomic oxygen resistant materials to replace the original high efficiency cell (HEC) array. Pending qualification of the BSFR-ATOX array, protective coatings for application to the existing HEC array were evaluated. Three polysiloxane-type coating materials, SWS V-10, DC-100, and CV-1144 were evaluated with respect to atomic oxygen resistance, outgassing, contamination potential, stability under UV irradiation, electron-proton irradiation, thermal cycling, and long-term storage after application. Atomic oxygen testing included characterization of the atomic oxygen plasma using comparison of Kapton reaction to existing flight data, residual gas analysis, and temperature measurements. Results from these tests show DC-100 as a greater contamination concern if used in the vicinity of sensitive optical surfaces, i.e., solar cell cover glasses. The SWS V-10 and CV-1144 coatings met all acceptance criteria.

Burns, H. D.↗

Materials degradation in low earth orbit (LEO); Proceedings of the Symposium, 119th Annual Meeting of the Minerals, Metals, and Materials Society, Anaheim, CA, Feb. 17-22, 1990

The current understanding of the effect of space environment on materials and the development of protective coatings is examined in reviews and reports. Consideration is given to hyperthermal atomic oxygen reactions, the effect of atomic oxygen on altered and coated Kapton surfaces for spacecraft applications in LEO, silicon dioxide space coatings studied ellipsometrically, atomic oxygen effects on spacecraft materials, atomic oxygen beam source for erosion simulation, and atomic oxygen effects on refractory materials. Particular attention is given to ellipsometric analysis of materials degradation in space, studies of the interaction of 8 km/s oxygen atoms with selected materials, characterization and calibration of the EOIM-III flight mass spectrometer in a high velocity oxygen atom beam, the reaction efficiency of thermal energy oxygen atoms with polymeric materials, and effects of simulated space environments on the properties of selected materials.

Srinivasan, V.↗

Atomic oxygen beam source for erosion simulation

A device for production of low-energy (5-10 eV) neutral atomic beams for surface modification studies, which recreates the flux of atomic oxygen in LEO, is described. The beam is produced by acceleration of plasma ions onto a negatively biased plate of high-Z metal; the ions are neutralized and reflected by the surface, retaining a large fraction of their incident kinetic energy, forming a beam of atoms. The device is based on a magnetically confined (3-4 kG) coaxial plasma source and the atom energy can be varied by adjusting the bias voltage. The source provides a neutral flux of roughly 5 x 10 to the 16th/sq cm/s at a distance of 10 cm and a fluence of roughly 10 to the 21st/sq cm in five hours. The source has been characterized with plasma diagnostics and by measuring the energy of an atomic argon beam using a mass spectrometer. Samples of carbon film, carbon-based paint, Kapton, Mylar, and Teflon exposed to atomic O beams show erosion quite similar to those observed in orbit on the Space Shuttle.

Cuthbertson, J. W.↗

The reaction efficiency of thermal energy oxygen atoms with polymeric materials

The reaction efficiency of several polymeric materials with thermal-energy (0.04 eV translational energy), ground-state (O3P) oxygen atoms was determined by exposing the materials to a room temperature gas containing a known concentration of atomic oxygen. The reaction efficiency measurements were conducted in two flowing afterglow systems of different configuration. Atomic oxygen concentration measurements, flow, transport and surface dose analysis is presented in this paper. The measured reaction efficiencies of Kapton, Mylar, polyethylene, D4-polyethylene and Tedlar are .001 to .0001 those determined with high-energy ground-state oxygen atoms in low earth orbit or in a high-velocity atom beam. D4-polyethylene exhibits a large kinetic isotope effect with atomic oxygen at thermal but not hyperthermal atom energies.

Koontz, S. L.↗

The mechanical properties of polyimide films after exposure to high pH

Wiring failures linked to insulation damage have drawn much attention in the aerospace industry and concerns have developed regarding the stability and safety of polyimide insulated electrical wire. Several polyimides were selected for evaluation for resistance to degradation by various aqueous alkaline solutions. The polyimides under evaluation include commercially available films such as Kapton (tk), Apical (tk), LaRC(tk)-TPI, and Upilex(tk)R and S, as well as a number of experimental films prepared by NASA Langley. Thermally imidized films were studied for their retention of mechanical properties after exposure to high pH solutions under stressed conditions.

Croall, Catharine I.↗

Measured space environmental effects to LDEF during retrieval

On the STS-32 shuttle mission, a space flight experiment provided an understanding of the effects of the space environment on the Long Duration Exposure Facility (LDEF) from rendezvous with the shuttle until removal from the payload bay at the Orbiter Processing Facility (OPF) at KSC. The Interim Operational Contamination Monitor (IOCM) is an attached shuttle payload that has been used on two earlier flights (STS 51C and STS 28) to quantify the contamination deposited during the course of the mission. The IOCM can characterize by direct measurement, the deposition of molecular and particulate contamination during any phase of flight. In addition to these principal measurements, the IOCM actively measures the thermophysical properties of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g. thermal cycling, atomic oxygen, and micrometeoroids and/or orbital debris, etc. One of the more salient results from the STS-32 flight suggests that the LDEF emitted a large number of particulates after berthing into the shuttle. The mission atomic oxygen fluence was also calculated. Although the fluence was low by normal standards, the Kapton passive samples exhibited the onset of erosion. Orbital debris and micrometeoroid impacts also occurred during the retrieval mission. The average perforation diameter was approximately 12.5 microns. The largest perforation diameter was measured at 65 microns.

Maag, Carl R.↗

Interactions of atomic oxygen with material surfaces in low Earth orbit: Preliminary results from experiment A0114

The atomic oxygen experiment consisted of two trays (one-sixth of a Long Duration Exposure Facility (LDEF) tray each) of 64 one inch diameter solid samples. It was intended that the effects of atomic oxygen and solar ultraviolet irradiation on the surface properties of each material could be distinguished from each other and from the effects of aging. Sixteen of the samples were placed on a thermally isolated plate of highly polished aluminum, while the main plate was coated with the thermal control coating S13-GLO. Though the experiment was entirely passive, it was hoped that the effects of thermal activation might be observed, if present. The plates were expected to stabilize at temperatures differing by 20-30 C. The samples included thin films of metals Os, Ir, Pt, Ni, Mo, and Al coated onto silica optical flats, metal carbides (WC, SiC), solid carbons of various types, eight polymers, and some other coatings of various types. Analysis is essentially complete using stylus profilometry with high sensitivity Talystep and lower sensitivity Talysurf machines. Though the integrated fluence of O atoms on the LDEF was 30 times that of previous missions, etch depths of the polymers such as the polyimide Kapton show excellent agreement with extrapolations from previous flight data. However, some new effects were observed. We demonstrated on a previous experiment on STS-8 that profilometry of this kind can show steps of 50 A (for example those due to oxide film growth on metals) and this is now the preferred method for estimating etch depth (or mass loss) of erodible substances.

Gregory, John C.↗

Preliminary results for LDEF/HEPP thermal control samples

Specimens of Kapton coated with black paint, white paint, and thin film oxides were flown at three locations aboard the Long Duration Exposure Facility (LDEF) to evaluate their resistance to atomic oxygen erosion. Post flight emittance and solar absorptance measurements are compared with pre-flight values.

Kauder, Lonny↗

Atomic oxygen interactions with FEP Teflon and silicones on LDEF

The Long Duration Exposure Facility (LDEF) spacecraft has enabled the measurement of the effects of fixed orientation exposure of high fluence atomic oxygen on fluorinated ethylene propylene (FEP Teflon) and silicones. The atomic oxygen erosion yield for the FEP Teflon was found to be 3.64 x 10(exp -25) cm(exp 3)/atom. This erosion yield is significantly higher than that measured from previous low fluence orbital data. The FEP Teflon erosion yield was found to have the same dependence on oxygen arrival angle as Kapton and Mylar. Atomic oxygen interaction with silicon polymers results in the crazing of silicon. Released silicone contaminants were found to darken upon further atomic oxygen exposure.

Bruce A. Banks↗

Development of a resettable, flexible aperture cover

A flexible aperture cover and latch were developed for the Thermal Ion Detection Experiment (TIDE). The latch utilized a high-output paraffin (HOP) linear motor to supply the force to operate the latch. The initial approach for the cover was to use a heat-treated, coiled strip of 0.05 mm (.002-inch)-thick beryllium-copper as the cover. Development test results showed that one end of the cover developed a trajectory during release that threatened to impact against adjacent instruments. An alternative design utilizing constant force springs and a flexible, metallized Kapton cover was then tested. Results from development tests, microgravity tests, and lessons learned during the development of the aperture cover are discussed.

Christiansen, Scott↗

An overview of the first results on the solar array materials passive LDEF experiment (sample), A0171

Power degradation in the solar cells was consistent with the exposure environment and appears to be produced principally by the radiation and atomic oxygen environments. Atomic oxygen erosion was generally as expected; atomic oxygen effects dominated for the most part in materials that were both atomic oxygen and ultraviolet vulnerable. Silicone coatings appear to protect Kapton, and adhesive systems contained under photon opaque materials were surprisingly environmentally resistant. A high density of small micro-meteroid/space debris impacts were observed on mirrors, protective coatings, paints, and composites. New synergistic effects of the space environment were noted in the interaction of atomic oxygen and copious amounts of contamination and in the induced luminescence of many materials.

Ann F Whitaker↗

LDEF SP-HVDE (Space Plasma-High Voltage Drainage Experiment) post-flight results: Leakage current and discharge

TRW designed and fabricated two identical SP-HVDE trays which were flown in the NASA LDEF (Long Duration Exposure Facility) for 5.75 years in the LEO (low earth orbit) environment. One tray was placed near the leading edge and one near the trailing edge, and investigations were performed to compare the environmental interactions on the dielectric samples of the two trays. Each tray consisted of six assemblies with Kapton dielectric samples of varying thicknesses (i.e., 2 mils, 3 mil, and 5 mils) biased under +/- 300 V, +/- 500 V, and +/- 1000 V. The original objective was successfully achieved by measuring the first in-flight average leakage current through the samples. Less than 5 percent of the post-flight coulometers behaved anomalously. The data should be valuable to the design and evaluation of spacecraft with high voltage systems. M/D (micrometeoroid and debris) impacts over the dielectric samples were examined using a SEM (Scanning Electron Microscope) and an EDS (Energy Dispersive x-ray Spectrometer). These impact sites were sprayed by silver which were most likely caused either by the impact or a 'local ESD' (electrostatic discharge).

Yaung, J. Y.↗

Measurements of the radiation dose to LDEF by means of passive dosimetry

A very simple experiment was fielded on LDEF to measure the energetic radiation dose by means of passive dosimetry. It consisted of two identical packets of 16 LiF thermoluminescent dosimeters (TLD) arranged in planar arrays. One array was placed on the leading edge of the spacecraft, the other on the trailing edge. These arrays were installed in opaque packets of 1 mil Al foil and Kapton tape mounted behind an Al plate of 30 mils thickness. The nominal energy thresholds were 14 MeV for protons and 650 keV for electrons. In addition to the flight arrays, two control arrays were prepared which were kept with the flight arrays as long as possible during experimental integration and then stored in the lab. The flight and control arrays were read out alternating in groups of four; it was found that the control dose was negligible. The flight and control detectors were exposed to a 55 MeV proton beam in order to provide a recalibration of the detectors. It was found that the post-flight and pre-flight calibrations were in good agreement. A comparison of results with the prediction shows that the measured dose was a factor of 4 to 5 low. It is possible that there was in-flight annealing of the TLDs as a result of the long mission and perhaps temperature excursions of the sensors. The East-West effect was larger than expected. The ratio of 1.65 is approximately what was expected for the protons alone. Electrons should reduce the dose ratio since electrons add equally to the leading and trailing edge dose. A possible explanation is that the electron dose was negligible compared to the proton dose.

Blake, J. B.↗